Ali I, Boumoua N, Sekkoum K, Belboukhari N, Ghfar A, Ouladsmane M, AlJumah BA. A comparison of chiral resolution of antifungal agents on different polysaccharide chiral columns under various mobile phase modes: Application in the biological samples.
J Chromatogr B Analyt Technol Biomed Life Sci 2021;
1175:122738. [PMID:
33992975 DOI:
10.1016/j.jchromb.2021.122738]
[Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 04/20/2021] [Accepted: 04/24/2021] [Indexed: 10/21/2022]
Abstract
The current article describes the chiral separation of tioconazole, miconazole, isoconazole, sertaconazole and terconazole, with Lux i-Cellulose 5 and Lux i-Amylose-1 chiral columns under organic polar, normal and reversed mobile phases modes. The mobile phase flow rate was 1 mL/min with 230 nm detection at 25 ± 1 °C temperature. The polar organic mobile phases offered certain advantages for separation such as short analysis time, order of elution, high plate numbers and favorable signal to noise ratio. The values of k, α and Rs were ranged from 0.6 to 7.87, 1.10 to 1.62 and 0.37 to 5.72 in polar organic, 0.15 to 43.86, 1.02 to 2.01 and 0.36 to 8.03 in normal, and 0.34 to 15.99, 1.03 to 1.40 and 0.59 to 4.18 in reversed phases modes, respectively. The reported methods were applied in urine samples and the results were satisfactory. The reported methods were applied to the analysis of urine samples.
Collapse