1
|
Won GY, Park A, Yoo Y, Park YI, Lee JH, Kim IC, Cho YH, Park H. Improving the Separation Properties of Polybenzimidazole Membranes by Adding Acetonitrile for Organic Solvent Nanofiltration. MEMBRANES 2023; 13:104. [PMID: 36676911 PMCID: PMC9864663 DOI: 10.3390/membranes13010104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 01/06/2023] [Accepted: 01/10/2023] [Indexed: 06/17/2023]
Abstract
In research on membranes, the addition of co-solvents to the polymer dope solution is a common method for tuning the morphology and separation performance. For organic solvent nanofiltration (OSN) applications, we synthesized polybenzimidazole (PBI) membranes with high separation properties and stability by adding acetonitrile (MeCN) to the dope solution, followed by crosslinking with dibromo-p-xylene. Accordingly, changes in the membrane structure and separation properties were investigated when MeCN was added. PBI/MeCN membranes with a dense and thick active layer and narrow finger-like macrovoids exhibited superior rejection properties in the ethanol solution compared with the pristine PBI membrane. After crosslinking, they displayed superior rejection properties (96.56% rejection of 366-g/mol polypropylene glycol). In addition, the membranes demonstrated stable permeances for various organic solvents, including acetone, methanol, ethanol, toluene, and isopropyl alcohol. Furthermore, to evaluate the feasibility of the modified PBI OSN membranes, ecamsule, a chemical product in the fine chemical industry, was recovered. Correspondingly, the efficient recovery of ecamsule from a toluene/methanol solution using the OSN process with PBI/MeCN membranes demonstrated their applicability in many fine chemical industries.
Collapse
Affiliation(s)
- Ga Yeon Won
- Green Carbon Research Center, Chemical Process Division, Korea Research Institute of Chemical Technology, Daejeon 34114, Republic of Korea
- Department of Chemical and Biological Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Ahrumi Park
- Green Carbon Research Center, Chemical Process Division, Korea Research Institute of Chemical Technology, Daejeon 34114, Republic of Korea
| | - Youngmin Yoo
- Green Carbon Research Center, Chemical Process Division, Korea Research Institute of Chemical Technology, Daejeon 34114, Republic of Korea
| | - You-In Park
- Green Carbon Research Center, Chemical Process Division, Korea Research Institute of Chemical Technology, Daejeon 34114, Republic of Korea
| | - Jung-Hyun Lee
- Department of Chemical and Biological Engineering, Korea University, Seoul 02841, Republic of Korea
| | - In-Chul Kim
- Green Carbon Research Center, Chemical Process Division, Korea Research Institute of Chemical Technology, Daejeon 34114, Republic of Korea
| | - Young Hoon Cho
- Green Carbon Research Center, Chemical Process Division, Korea Research Institute of Chemical Technology, Daejeon 34114, Republic of Korea
- Department of Advanced Materials and Chemical Engineering, University of Science and Technology, Daejeon 34113, Republic of Korea
| | - Hosik Park
- Green Carbon Research Center, Chemical Process Division, Korea Research Institute of Chemical Technology, Daejeon 34114, Republic of Korea
- Department of Advanced Materials and Chemical Engineering, University of Science and Technology, Daejeon 34113, Republic of Korea
| |
Collapse
|
2
|
|
3
|
Solubility Models for the Recovery of Rosmarinic Acid from Orthosiphon Aristatus Extract Using Solid Phase Extraction. CHEMENGINEERING 2019. [DOI: 10.3390/chemengineering3030064] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Hildebrand and Hansen solubility parameters, and log P value are widely used to determine the solubility of polymers in solvents. The models were used to explain the recovery of phytochemical, rosmarinic acid from Orthosiphon aristatus extract in C18 solid phase extraction (SPE) using the eluent consisting of ethyl acetate and chloroform in the decreasing polarity of solvent system. The experimental recovery of rosmarinic acid appeared to be well explained by the Hansen solubility model. The small difference in the Hansen solubility parameters, particularly for dispersion and hydrogen bonding forces, results in a higher polar solvent system for high rosmarinic acid recovery. The results found that the Hansen solubility model fitted well to the recovery of rosmarinic acid from crude extract with high coefficient of determination (R2 > 0.8), low standard error (4.4%), and p < 0.05. Hildebrand solubility is likely to be the second fit model, whereas log P has poor R2 < 0.7 and higher standard error (7.3%). The Hansen solubility model describes the interaction of solute–solvent in three dimensions (dispersion, polar, and hydrogen bonding forces) which can accurately explain the recovery of rosmarinic acid. Therefore, Hansen solubility can be used to predict the recovery of rosmarinic acid from O. aristatus extract using SPE.
Collapse
|
4
|
Influence of Solvent Selection in the Electrospraying
Process of Polycaprolactone. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9030402] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Electrosprayed polycaprolactone (PCL) microparticles are widely used in medical tissueengineering, drug control release delivery, and food packaging due to their prominent structuresand properties. In electrospraying, the selection of a suitable solvent system as the carrier of PCL isfundamental and a prerequisite for the stabilization of electrospraying, and the control ofmorphology and structure of electrosprayed particles. The latter is not only critical for diversifyingthe characteristics of electrosprayed particles and achieving improvement in their properties, butalso promotes the efficiency of the process and deepens the applications of electrosprayed particlesin various fields. In order to make it systematic and more accessible, this review mainly concludesthe effects of different solution properties on the operating parameters in electrospraying on theformation of Taylor cone and the final structure as well as the morphology. Meanwhile,correlations between operating parameters and electrospraying stages are summarized as well.Finally, this review provides detailed guidance on the selection of a suitable solvent systemregarding the desired morphology, structure, and applications of PCL particles.
Collapse
|
5
|
Relić D, Héberger K, Sakan S, Škrbić B, Popović A, Đorđević D. Ranking and similarity of conventional, microwave and ultrasound element sequential extraction methods. CHEMOSPHERE 2018; 198:103-110. [PMID: 29421718 DOI: 10.1016/j.chemosphere.2017.12.200] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2017] [Revised: 12/29/2017] [Accepted: 12/31/2017] [Indexed: 06/08/2023]
Abstract
This study aims to compare three extraction techniques of four sequential element extraction steps from soil and sediment samples that were taken from the location of the Pančevo petrochemical industry (Serbia). Elements were extracted using three different techniques: conventional, microwave and ultrasound extraction. A novel procedure - sum of the ranking differences (SRD) - was able to rank the techniques and elements, to see whether this method is a suitable tool to reveal the similarities and dissimilarities in element extraction techniques, provided that a proper ranking reference is available. The concentrations of the following elements Al, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Si, Sn, Sr, V and Zn were determined through ICP OES. The different efficiencies and recovery values of element concentrations using each of the three extraction techniques were examined by the CRM BCR-701. By using SRD, we obtained a better separation between the different extraction techniques and steps when we rank their differences among the samples while lower separation was obtained according to analysed elements. Appling this method for ordering the elements could be useful for three purposes: (i) to find possible associations among the elements; (ii) to find possible elements that have outlier concentrations or (iii) detect differences in geochemical origin or behaviour of elements. Cross-validation of the SRD values in combination with cluster and principal component analysis revealed the same groups of extraction steps and techniques.
Collapse
Affiliation(s)
- Dubravka Relić
- University of Belgrade, Faculty of Chemistry, Studentski trg 12-16, Belgrade, 11158, Serbia.
| | - Károly Héberger
- Plasma Chemistry Research Group, Research Centre for Natural Sciences, Hungarian Academy of Sciences, H-1117 Budapest, Magyar tudósok krt. 2, Hungary
| | - Sanja Sakan
- Centre of Excellence in Environmental Chemistry and Engineering, ICTM, University of Belgrade, Njegoševa 12, Belgrade, 11158, Serbia
| | - Biljana Škrbić
- University of Novi Sad, Faculty of Technology, Bulevar cara Lazara 1, 21000, Novi Sad, Serbia
| | - Aleksandar Popović
- University of Belgrade, Faculty of Chemistry, Studentski trg 12-16, Belgrade, 11158, Serbia
| | - Dragana Đorđević
- Centre of Excellence in Environmental Chemistry and Engineering, ICTM, University of Belgrade, Njegoševa 12, Belgrade, 11158, Serbia.
| |
Collapse
|
6
|
Kanie Y, Taniuchi M, Kanie O. Evaluation of reversed-phase nano liquid chromatography conditions by using reversed-phase thin layer chromatography based on Hansen solubility parameters for the analysis of amphiphilic glycosylsphingolipid transformations. J Chromatogr A 2018; 1534:123-129. [PMID: 29290400 DOI: 10.1016/j.chroma.2017.12.058] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2017] [Revised: 12/20/2017] [Accepted: 12/21/2017] [Indexed: 11/30/2022]
Abstract
Pulse chase analysis is often used in investigating dynamics of cellular substances. Fluorescently labeled lactosyl sphingosine molecule is useful in chasing its transformation, however the analysis of such metabolites in attomole level is of extreme difficult due to the presence of large amount of endogenous amphiphilic molecules such as glycosphingolipids, sphingomyerin, and glycerophospholipids. Nano LC suites for analyzing the attomole scale metabolites, therefore removal of endogenous substances prior to nano LC and finding appropriate nano LC conditions are necessary. Thus, we focused on the solubility of fluorescent BODIPY-labeled lactosylsphingosine (Lac-Sph-BODIPY) to identify suitable solvents to remove endogenous compounds. In this study, we evaluated solvents by using C18 thin layer chromatography (RP TLC). The mobility (Rf) of Lac-Sph-BODIPY against several solvent mixtures on RP TLC were plotted against polarity and hydrogen bonding capability followed by Hansen solubility parameters (HSPs). The optimum solvent mixture with Rf = 0.3 ± 0.1 was chosen for elimination of endogenous phospholipids on a ZrO2-SiO2 cartridge column and subsequent separation by nano LC. Efficient removal of endogenous phospholipids was demonstrated, and good resolution in nano LC analysis of Lac-Sph-BODIPY extracted from Chinese hamster ovary (CHO)-K1 cells was achieved. It was also shown that the amount of exogenously added compound was important in the investigation of metabolites using cultured cells.
Collapse
Affiliation(s)
- Yoshimi Kanie
- Department of Applied Biochemistry, Tokai University, 4-1-1 Kitakaname, Hiratsuka, 259-1292 Kanagawa, Japan
| | - Mizuki Taniuchi
- Department of Applied Biochemistry, Tokai University, 4-1-1 Kitakaname, Hiratsuka, 259-1292 Kanagawa, Japan
| | - Osamu Kanie
- Department of Applied Biochemistry, Tokai University, 4-1-1 Kitakaname, Hiratsuka, 259-1292 Kanagawa, Japan.
| |
Collapse
|
7
|
Bielicka-Daszkiewicz K. Extraction techniques based on solid state and connected with liquid chromatography. J LIQ CHROMATOGR R T 2016. [DOI: 10.1080/10826076.2016.1163501] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
8
|
Bielicka-Daszkiewicz K. Different methods to select the best extraction system for solid-phase extraction. J Sep Sci 2015; 38:439-44. [DOI: 10.1002/jssc.201401083] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2014] [Revised: 11/12/2014] [Accepted: 11/12/2014] [Indexed: 11/06/2022]
Affiliation(s)
- Katarzyna Bielicka-Daszkiewicz
- Institute of Technology and Chemical Engineering; Poznań University of Technology ul. Berdychowo 4; 60-965 Poznań Poland
| |
Collapse
|
9
|
Solubility parameter used to predict the effectiveness of monolithic in-needle extraction (MINE) device for the direct analysis of liquid samples. Anal Chim Acta 2013; 805:54-9. [DOI: 10.1016/j.aca.2013.10.049] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2013] [Revised: 10/29/2013] [Accepted: 10/29/2013] [Indexed: 11/18/2022]
|
10
|
Škrbić B, Héberger K, Đurišić-Mladenović N. Comparison of multianalyte proficiency test results by sum of ranking differences, principal component analysis, and hierarchical cluster analysis. Anal Bioanal Chem 2013; 405:8363-75. [DOI: 10.1007/s00216-013-7206-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2013] [Revised: 05/02/2013] [Accepted: 07/02/2013] [Indexed: 10/26/2022]
|
11
|
|
12
|
Comparison of comet assay parameters for estimation of genotoxicity by sum of ranking differences. Anal Bioanal Chem 2013; 405:4879-85. [DOI: 10.1007/s00216-013-6909-y] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2012] [Revised: 02/01/2013] [Accepted: 03/08/2013] [Indexed: 11/30/2022]
|
13
|
Bielicka-Daszkiewicz K, Voelkel A, Rusińska-Roszak D, Zarzycki PK. Estimation of the breakthrough volume of selected steroids for C-18 solid-phase extraction sorbent using retention data from micro-thin layer chromatography. J Sep Sci 2013; 36:1104-11. [DOI: 10.1002/jssc.201200917] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2012] [Revised: 12/18/2012] [Accepted: 12/19/2012] [Indexed: 11/06/2022]
Affiliation(s)
| | - Adam Voelkel
- Institute of Technology and Chemical Engineering; Poznań University of Technology; Poznań Poland
| | - Danuta Rusińska-Roszak
- Institute of Technology and Chemical Engineering; Poznań University of Technology; Poznań Poland
| | - Paweł K. Zarzycki
- Section of Toxicology and Bioanalysis; Koszalin University of Technology; Koszalin Poland
| |
Collapse
|
14
|
Sudharshan Reddy A, Reddi Rani P, Subramanyam Reddy K. Lewis acid-base properties of cellulose acetate phthalate-polycaprolactonediol blend by inverse gas chromatography. POLYM ENG SCI 2013. [DOI: 10.1002/pen.23421] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
15
|
Ramanaiah S, Reddy AS, Reddy KS. Hansen solubility parameters of cellulose acetate butyrate–poly(caprolactone) diol blend by inverse gas chromatography. Polym Bull (Berl) 2012. [DOI: 10.1007/s00289-012-0855-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
16
|
Héberger K, Škrbić B. Ranking and similarity for quantitative structure–retention relationship models in predicting Lee retention indices of polycyclic aromatic hydrocarbons. Anal Chim Acta 2012; 716:92-100. [DOI: 10.1016/j.aca.2011.11.061] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2011] [Revised: 11/23/2011] [Accepted: 11/28/2011] [Indexed: 10/14/2022]
|