1
|
Hayes M, Hettiarachchi K, Lang S, Wang J, Greshock TJ. Ultra-fast microscale purification of chiral racemates and achiral pharmaceuticals with analytical supercritical fluid chromatography. J Chromatogr A 2022; 1665:462829. [DOI: 10.1016/j.chroma.2022.462829] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 01/04/2022] [Accepted: 01/12/2022] [Indexed: 11/16/2022]
|
2
|
A perspective on enantioselective chromatography by comparing ultra-high performance supercritical fluid chromatography and normal-phase liquid chromatography through the use of a Pirkle-type stationary phase. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2021.116511] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
3
|
Khater S, Ferguson P, Grand-Guillaume-Perrenoud A. Method development approaches for small-molecule analytes. SEP SCI TECHNOL 2022. [DOI: 10.1016/b978-0-323-88487-7.00005-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
|
4
|
Chen L, Dean B, Liang X. A technical overview of supercritical fluid chromatography-mass spectrometry (SFC-MS) and its recent applications in pharmaceutical research and development. DRUG DISCOVERY TODAY. TECHNOLOGIES 2021; 40:69-75. [PMID: 34916026 DOI: 10.1016/j.ddtec.2021.10.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2021] [Revised: 09/28/2021] [Accepted: 10/05/2021] [Indexed: 06/14/2023]
Abstract
In this paper, we review the growing development and applications of supercritical fluid chromatography-mass spectrometry (SFC-MS) for the analysis of small molecular analytes and biomarkers in drug discovery. As an alternative chromatographic technique, SFC instrumentation and methodology have dramatically advanced over the last decade. Mass spectrometry (MS) provides the powerful detection capability as it couples with SFC. A growing number of SFC-MS/MS applications were reported over the last decade and the application areas of SFC-MS/MS is rapidly expanding. The first part of this review is devoted to the different aspects of SFC-MS development and recent technological advancements. In the second part of this review, we highlight the recent application areas in pharmaceutical research and development.
Collapse
Affiliation(s)
- Liuxi Chen
- Drug Metabolism & Pharmacokinetics, 1 DNA way, Genentech Inc., South San Francisco, CA, USA.
| | - Brian Dean
- Drug Metabolism & Pharmacokinetics, 1 DNA way, Genentech Inc., South San Francisco, CA, USA
| | - Xiaorong Liang
- Drug Metabolism & Pharmacokinetics, 1 DNA way, Genentech Inc., South San Francisco, CA, USA
| |
Collapse
|
5
|
Automated chiral method screening - Evaluation of generated chromatographic data sets to further optimize screening efficiency. J Chromatogr A 2021; 1644:462094. [PMID: 33823386 DOI: 10.1016/j.chroma.2021.462094] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 03/17/2021] [Accepted: 03/19/2021] [Indexed: 10/21/2022]
Abstract
We set up an automated screening process to routinely test 10 chiral supercritical fluid chromatography (SFC) methods - five columns combined with two co-solvents - as part of a chiral separation lab workflow. Proprietary software tools enabled automated method screening of racemates, parallel evaluation of the resulting chromatograms for enantiomer separation and report generation. This process is largely automated and resulted in an efficient and reliable lab process with a minimum requirement for human intervention. Screenings were conducted on a test set of 756 racemates that were selected with focus on structural variation and on 2667 proprietary samples from lab routines. Statistical analysis revealed that up to 92% of the tested racemic mixtures could be successfully separated with at least one of the tested conditions of the screening. Process efficiency was further increased by identification of optimal method screening sequence, re-definition of the optimal column set and project-specific adaptations considering reduced structural variation of the analytes. This study illustrates the usefulness of consistent chromatographic data sets to accelerate and facilitate the identification of chiral methods to separate enantiomers by automated processing and statistical analysis.
Collapse
|
6
|
Chiral chromatography method screening strategies: Past, present and future. J Chromatogr A 2021; 1638:461878. [PMID: 33477025 DOI: 10.1016/j.chroma.2021.461878] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2020] [Revised: 12/31/2020] [Accepted: 01/02/2021] [Indexed: 11/23/2022]
Abstract
Method screening is an integral part of chromatographic method development for the separation of racemates. Due to the highly complex retention mechanism of a chiral stationary-phase, it is often difficult, if not impossible, to device predefined method-development steps that can be successfully applied to a wide group of molecules. The standard approach is to evaluate or screen a series of stationary and mobile-phase combinations to increase the chances of detecting a suitable separation condition. Such a process is often the rate-limiting step for high-throughput analyses and purification workflows. To address the problem, several solutions and strategies have been proposed over the years for reduction of net method-screening time. Some of the strategies have been adopted in practice while others remained confined in the literature. The main objective of this review is to revisit, critically discuss and compile the solutions published over the last two decades. We expect that making the diverse set of solutions available in a single document will help assessing the adequacy of existing screening protocols in laboratories conducting chiral separation.
Collapse
|
7
|
Rendering A Chiral Screening Step In Supercritical Fluid Chromatography Mass-Spectrometry Compatible. J Chromatogr A 2020; 1624:461201. [DOI: 10.1016/j.chroma.2020.461201] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Revised: 04/28/2020] [Accepted: 05/04/2020] [Indexed: 12/31/2022]
|
8
|
Jakubec P, Douša M, Nováková L. Supercritical fluid chromatography in chiral separations: Evaluation of equivalency of polysaccharide stationary phases. J Sep Sci 2020; 43:2675-2689. [DOI: 10.1002/jssc.202000085] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2020] [Revised: 03/21/2020] [Accepted: 03/25/2020] [Indexed: 12/24/2022]
Affiliation(s)
- Pavel Jakubec
- Department of Analytical ChemistryFaculty of Pharmacy in Hradec KrálovéCharles University Hradec Králové Czech Republic
| | - Michal Douša
- Akademika Heyrovského 1203Zentiva k.s. Praha 10 Czech Republic
| | - Lucie Nováková
- Department of Analytical ChemistryFaculty of Pharmacy in Hradec KrálovéCharles University Hradec Králové Czech Republic
| |
Collapse
|
9
|
Wu D, Pan F, Tan W, Gao L, Tao Y, Kong Y. Recent progress of enantioseparation under scale production (2014–2019). J Sep Sci 2019; 43:337-347. [DOI: 10.1002/jssc.201900682] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2019] [Revised: 10/11/2019] [Accepted: 10/28/2019] [Indexed: 12/11/2022]
Affiliation(s)
- Datong Wu
- Jiangsu Key Laboratory of Advanced Materials and TechnologySchool of Petrochemical EngineeringChangzhou University Changzhou P. R. China
| | - Fei Pan
- Jiangsu Key Laboratory of Advanced Materials and TechnologySchool of Petrochemical EngineeringChangzhou University Changzhou P. R. China
| | - Wensheng Tan
- Changzhou Key Laboratory of Large Plastic Parts Intelligence ManufacturingChangzhou College of Information Technology Changzhou P. R. China
| | - Li Gao
- Jiangsu Key Laboratory of Advanced Materials and TechnologySchool of Petrochemical EngineeringChangzhou University Changzhou P. R. China
| | - Yongxin Tao
- Jiangsu Key Laboratory of Advanced Materials and TechnologySchool of Petrochemical EngineeringChangzhou University Changzhou P. R. China
| | - Yong Kong
- Jiangsu Key Laboratory of Advanced Materials and TechnologySchool of Petrochemical EngineeringChangzhou University Changzhou P. R. China
| |
Collapse
|
10
|
Evaluation of polysaccharide-based chiral stationary phases in modern SFC-MS/MS for enantioselective bioanalysis. Bioanalysis 2019; 11:251-266. [PMID: 30672314 DOI: 10.4155/bio-2018-0168] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
Aim: The applicability of polysaccharide-based chiral stationary phases in modern supercritical fluid chromatography (SFC)-MS/MS for chiral bioanalysis was evaluated. Materials & methods: Ten popular polysaccharide-based chiral stationary phases (CSPs) were tested using a set of 23 drugs against three cosolvents. The effect of temperature and backpressure on separation was examined. Results: The recommended order of CSPs for screening was determined. Methanol with 0.1% NH4OH is proven to be the first choice of cosolvent. Temperature of 40°C and backpressure of 10 or 15 MPa are recommended starting conditions. Phospholipid elution profiles on the polysaccharide-based CSPs were reported for the first time under SFC conditions. Conclusion: A simplified screening protocol with straightforward method optimization approaches was generated for SFC chiral assay development in a reasonable time frame with a high success rate.
Collapse
|
11
|
Ciogli A, Ismail OH, Mazzoccanti G, Villani C, Gasparrini F. Enantioselective ultra high performance liquid and supercritical fluid chromatography: The race to the shortest chromatogram. J Sep Sci 2018; 41:1307-1318. [PMID: 29319915 DOI: 10.1002/jssc.201701406] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2017] [Revised: 12/23/2017] [Accepted: 12/25/2017] [Indexed: 11/11/2022]
Abstract
The ever-increasing need for enantiomerically pure chiral compounds has greatly expanded the number of enantioselective separation methods available for the precise and accurate measurements of the enantiomeric purity. The introduction of chiral stationary phases for liquid chromatography in the last decades has revolutionized the routine methods to determine enantiomeric purity of chiral drugs, agrochemicals, fragrances, and in general of organic and organometallic compounds. In recent years, additional efforts have been placed on faster, enantioselective analytical methods capable to fulfill the high throughput requirements of modern screening procedures. Efforts in this field, capitalizing on improved chromatographic particle technology and dedicated instrumentation, have led to highly efficient separations that are routinely completed on the seconds time scale. An overview of the recent achievements in the field of ultra-high-resolution chromatography on column packed with chiral stationary phases, both based on sub-2 μm fully porous and sub-3 μm superficially porous particles, will be given, with an emphasis on very recent studies on ultrafast chiral separations.
Collapse
Affiliation(s)
- Alessia Ciogli
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| | - Omar H Ismail
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| | - Giulia Mazzoccanti
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| | - Claudio Villani
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| | - Francesco Gasparrini
- Dipartimento di Chimica e Tecnologie del Farmaco, "Sapienza" Università di Roma, Rome, Italy
| |
Collapse
|
12
|
Mao XJ, Li J, Liu D, Qiao T, Ma L, Sun X, Xu L, Shi ZG. Flow-through silica: A potential matrix for fast chromatographic enantioseparation with high enantioselectivity. Talanta 2018; 178:583-587. [DOI: 10.1016/j.talanta.2017.09.093] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2017] [Revised: 09/18/2017] [Accepted: 09/30/2017] [Indexed: 11/15/2022]
|
13
|
Calcaterra A, D’Acquarica I. The market of chiral drugs: Chiral switches versus de novo enantiomerically pure compounds. J Pharm Biomed Anal 2018; 147:323-340. [DOI: 10.1016/j.jpba.2017.07.008] [Citation(s) in RCA: 195] [Impact Index Per Article: 27.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2017] [Revised: 07/06/2017] [Accepted: 07/08/2017] [Indexed: 10/19/2022]
|
14
|
Berger TA. Preliminary kinetic evaluation of an immobilized polysaccharide sub-2μm column using a low dispersion supercritical fluid chromatograph. J Chromatogr A 2017; 1510:82-88. [PMID: 28652002 DOI: 10.1016/j.chroma.2017.06.021] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Revised: 06/03/2017] [Accepted: 06/09/2017] [Indexed: 11/25/2022]
Abstract
The performance of a 3×50mm, 1.6μm dp column with an immobilized polysaccharide stationary phase (ChiralPak IA-U) was evaluated for efficiency, and pressure drop, with respect to flow rate and modifier concentration using supercritical fluid chromatography (SFC). This appears to be the first such report using such a column in SFC. A unique low dispersion (ultra-high performance) SFC was used for the evaluation. The minimum reduced plate height of 2.78, indicates that the maximum efficiency was similar to or better than coated polysaccharide columns. Selectivity was different from ChiralPak AD, with the same chiral selector, as reported by many others. At high flows and high methanol concentrations, pump pressures sometimes approached 600bar. With 5% methanol, pressure vs. flow rate was non-linear suggesting turbulent flow in the connector tubing. The optimum flow rate (Fopt) at 40% methanol was ≈0.8mL/min, where the column efficiency was highest. At 5% methanol, Fopt increased to ≈1.6mL/min, but efficiency degraded noticeably. The differences in Fopt suggests that the solute diffusion coefficients are a strong function of modifier concentration. Several sub-1min separations, including a 7.5s separation, are presented.
Collapse
Affiliation(s)
- Terry A Berger
- SFC Solutions Inc., 9435 Downing St., Englewood, FL 34224, USA.
| |
Collapse
|
15
|
Ali I, Suhail M, Asnin L. Chiral separation of quinolones by liquid chromatography and capillary electrophoresis. J Sep Sci 2017; 40:2863-2882. [PMID: 28510993 DOI: 10.1002/jssc.201700200] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2017] [Revised: 05/02/2017] [Accepted: 05/02/2017] [Indexed: 12/29/2022]
Abstract
The quinolones are derivatives of oxoquinolines and mostly known for their antibacterial and antiviral activities. Many quinolones are chiral compounds having asymmetric centers and important due to their enantioselective biological activities. In order to study the biological activities of quinolone enantiomers, to control the manufacturing of homochiral drugs and to prepare necessary quantities of pure enantiomers for preclinical or clinical trials, respective chiral separation methods are urgently needed. In this context, the present review discusses chromatographic and electrophoretic methods for the enantioseparation of chiral quinolones and provides some useful information on their physical and pharmaceutical properties. The drawbacks of currently used techniques are revealed and ways to overcome them are outlined. Moreover, recommendations for an optimal choice of a separation protocol are given.
Collapse
Affiliation(s)
- Imran Ali
- Department of Chemistry, Jamia Millia Islamia (Central University), New Delhi, India
| | - Mohd Suhail
- Department of Chemistry, Jamia Millia Islamia (Central University), New Delhi, India
| | - Leonid Asnin
- Perm National Research Polytechnic University, Perm, Russia
| |
Collapse
|
16
|
Evertsson E, Rönnberg J, Stålring J, Thunberg L. A hierarchical screening approach to enantiomeric separation. Chirality 2017; 29:202-212. [DOI: 10.1002/chir.22694] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2016] [Revised: 12/21/2016] [Accepted: 12/23/2016] [Indexed: 11/07/2022]
Affiliation(s)
- Emma Evertsson
- Medicinal Chemistry RIA; AstraZeneca R&D; Gothenburg Sweden
| | | | | | - Linda Thunberg
- Medicinal Chemistry RIA; AstraZeneca R&D; Gothenburg Sweden
| |
Collapse
|
17
|
Quinine bonded to superficially porous particles for high-efficiency and ultrafast liquid and supercritical fluid chromatography. Anal Chim Acta 2017; 963:164-174. [DOI: 10.1016/j.aca.2017.02.005] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Revised: 02/02/2017] [Accepted: 02/10/2017] [Indexed: 11/20/2022]
|
18
|
Nováková L, Douša M. General screening and optimization strategy for fast chiral separations in modern supercritical fluid chromatography. Anal Chim Acta 2017; 950:199-210. [DOI: 10.1016/j.aca.2016.11.002] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Revised: 10/22/2016] [Accepted: 11/02/2016] [Indexed: 10/20/2022]
|
19
|
Berger TA. Characterizing pressure issues due to turbulent flow in tubing, in ultra-fast chiral supercritical fluid chromatography at up to 580bar. J Chromatogr A 2016; 1475:86-94. [DOI: 10.1016/j.chroma.2016.10.073] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Revised: 10/27/2016] [Accepted: 10/28/2016] [Indexed: 11/29/2022]
|
20
|
Patel DC, Wahab MF, Armstrong DW, Breitbach ZS. Advances in high-throughput and high-efficiency chiral liquid chromatographic separations. J Chromatogr A 2016; 1467:2-18. [DOI: 10.1016/j.chroma.2016.07.040] [Citation(s) in RCA: 119] [Impact Index Per Article: 13.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2016] [Revised: 07/13/2016] [Accepted: 07/15/2016] [Indexed: 01/08/2023]
|
21
|
Berger TA. Kinetic performance of a 50mm long 1.8μm chiral column in supercritical fluid chromatography. J Chromatogr A 2016; 1459:136-144. [PMID: 27423775 DOI: 10.1016/j.chroma.2016.07.012] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2016] [Revised: 07/04/2016] [Accepted: 07/05/2016] [Indexed: 11/25/2022]
Abstract
Reduced plate heights (hr) of <2 were observed for the first time during the chiral separation of enantiomers, on sub-2μm particles with supercritical fluid chromatography (SFC). The enantiomers of trans-stilbene oxide, were separated on a 4.6×50mm, 1.8μm R,R-Whelk-O1 column, with hr as low as 1.93. The plumbing of a commercial SFC instrument was modified to create a low dispersion version. Without the modification performance was considerably worse. vanDeemter like plots of reduced plate height vs. flow rate, for trans-stilbene oxide, indicate that the optimum flow varied with% modifier. On a 4.6×250mm, 5μm R,R- Whelk-O1 column, the optimum flow was >4mL/min for 5% methanol in CO2, decreasing to <2mL/min for 40% methanol (more than a factor of 2). For a 4.6×50mm column packed with 1.8μm particles the optimum appeared to be near, or >5mL/min with 2.5%, 5%, and 10% methanol, decreasing to between 3 and 3.5mL/min at 40% methanol. This is the first time such shifts have been characterized. Since the solutes were the same in all cases, the differences are likely due to changes in solute diffusion coefficients caused by changes in modifier concentration, and pressure. Pump pressure requirements sometimes exceeded 500bar. It is shown that a 5mL/min flow rate is inadequate for use with 1.8μm particles in a 4.6mm ID column format. Instead, it is suggested to decrease the ID of the column to 3mm, where the optimum flow rates are on the order of 2mL/min with decreased tubing variance. Nevertheless, a number of sub-1min chromatograms are presented.
Collapse
Affiliation(s)
- Terry A Berger
- SFC Solutions, Inc., 9435 Downing St, Englewood, FL 34224, USA.
| |
Collapse
|
22
|
Analytical advances in pharmaceutical impurity profiling. Eur J Pharm Sci 2016; 87:118-35. [DOI: 10.1016/j.ejps.2015.12.007] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2015] [Revised: 11/14/2015] [Accepted: 12/05/2015] [Indexed: 01/11/2023]
|
23
|
From analytical methods to large scale chiral supercritical fluid chromatography using chlorinated chiral stationary phases. J Chromatogr A 2016; 1432:122-31. [DOI: 10.1016/j.chroma.2015.12.072] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2015] [Revised: 12/22/2015] [Accepted: 12/26/2015] [Indexed: 11/24/2022]
|
24
|
Lemasson E, Bertin S, West C. Use and practice of achiral and chiral supercritical fluid chromatography in pharmaceutical analysis and purification. J Sep Sci 2016; 39:212-33. [DOI: 10.1002/jssc.201501062] [Citation(s) in RCA: 83] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2015] [Revised: 10/21/2015] [Accepted: 10/21/2015] [Indexed: 11/09/2022]
Affiliation(s)
- Elise Lemasson
- Institut de Chimie Organique et Analytique (ICOA); Univ Orleans, CNRS; Orléans cedex France
| | | | - Caroline West
- Institut de Chimie Organique et Analytique (ICOA); Univ Orleans, CNRS; Orléans cedex France
| |
Collapse
|
25
|
Rossi D, Marra A, Rui M, Brambilla S, Juza M, Collina S. “Fit-for-purpose” development of analytical and (semi)preparative enantioselective high performance liquid and supercritical fluid chromatography for the access to a novel σ 1 receptor agonist. J Pharm Biomed Anal 2016; 118:363-369. [DOI: 10.1016/j.jpba.2015.10.047] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2015] [Revised: 10/30/2015] [Accepted: 10/31/2015] [Indexed: 10/22/2022]
|
26
|
Supercritical fluid chromatography in pharmaceutical analysis. J Pharm Biomed Anal 2015; 113:56-71. [DOI: 10.1016/j.jpba.2015.03.007] [Citation(s) in RCA: 164] [Impact Index Per Article: 16.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2015] [Revised: 03/03/2015] [Accepted: 03/05/2015] [Indexed: 12/21/2022]
|
27
|
Patel DC, Breitbach ZS, Wahab MF, Barhate CL, Armstrong DW. Gone in seconds: praxis, performance, and peculiarities of ultrafast chiral liquid chromatography with superficially porous particles. Anal Chem 2015; 87:9137-48. [PMID: 25945416 DOI: 10.1021/acs.analchem.5b00715] [Citation(s) in RCA: 130] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
A variety of brush-type chiral stationary phases (CSPs) were developed using superficially porous particles (SPPs). Given their high efficiencies and relatively low back pressures, columns containing these particles were particularly advantageous for ultrafast "chiral" separations in the 4-40 s range. Further, they were used in all mobile phase modes and with high flow rates and pressures to separate over 60 pairs of enantiomers. When operating under these conditions, both instrumentation and column packing must be modified or optimized so as not to limit separation performance and quality. Further, frictional heating results in axial thermal gradients of up to 16 °C and radial temperature gradients up to 8 °C, which can produce interesting secondary effects in enantiomeric separations. It is shown that the kinetic behavior of various CSPs can differ from one another as much as they differ from the well-studied C18 reversed phase media. Three additional interesting aspects of this work are (a) the first kinetic evidence of two different chiral recognition mechanisms, (b) a demonstration of increased efficiencies at higher flow rates for specific separations, and
Collapse
Affiliation(s)
- Darshan C Patel
- Department of Chemistry and Biochemistry, University of Texas at Arlington , Arlington, Texas 76019, United States
| | - Zachary S Breitbach
- Department of Chemistry and Biochemistry, University of Texas at Arlington , Arlington, Texas 76019, United States
| | - M Farooq Wahab
- Department of Chemistry and Biochemistry, University of Texas at Arlington , Arlington, Texas 76019, United States
| | - Chandan L Barhate
- Department of Chemistry and Biochemistry, University of Texas at Arlington , Arlington, Texas 76019, United States
| | - Daniel W Armstrong
- Department of Chemistry and Biochemistry, University of Texas at Arlington , Arlington, Texas 76019, United States.,AZYP LLC , 700 Planetarium Place, Arlington, Texas 76019, United States
| |
Collapse
|
28
|
Sciascera L, Ismail O, Ciogli A, Kotoni D, Cavazzini A, Botta L, Szczerba T, Kocergin J, Villani C, Gasparrini F. Expanding the potential of chiral chromatography for high-throughput screening of large compound libraries by means of sub–2μm Whelk-O 1 stationary phase in supercritical fluid conditions. J Chromatogr A 2015; 1383:160-8. [DOI: 10.1016/j.chroma.2015.01.042] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2014] [Revised: 01/13/2015] [Accepted: 01/14/2015] [Indexed: 10/24/2022]
|
29
|
Development and validation of a supercritical fluid chromatography method for the direct determination of enantiomeric purity of provitamin B5 in cosmetic formulations with mass spectrometric detection. J Pharm Biomed Anal 2015; 102:321-5. [DOI: 10.1016/j.jpba.2014.09.036] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2014] [Revised: 09/26/2014] [Accepted: 09/29/2014] [Indexed: 11/18/2022]
|
30
|
Wang CC, Hartmann-Fischbach P, Krueger TR, Lester A, Simonson A, Wells TL, Wolk MO, Hidlay NJ. Fast and Sensitive Chiral Analysis of Amphetamines and Cathinones in Equine Urine and Plasma Using Liquid Chromatography Tandem Mass Spectrometry. ACTA ACUST UNITED AC 2015. [DOI: 10.4236/ajac.2015.613094] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
31
|
Grand-Guillaume Perrenoud A, Veuthey JL, Guillarme D. The use of columns packed with sub-2 µm particles in supercritical fluid chromatography. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2014.06.023] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
32
|
|
33
|
|
34
|
Insights into chiral recognition mechanism in supercritical fluid chromatography III. Non-halogenated polysaccharide stationary phases. J Chromatogr A 2014; 1363:278-93. [DOI: 10.1016/j.chroma.2014.06.084] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2014] [Revised: 06/18/2014] [Accepted: 06/24/2014] [Indexed: 11/19/2022]
|
35
|
Enantioseparation of chiral pharmaceuticals in biomedical and environmental analyses by liquid chromatography: An overview. J Chromatogr B Analyt Technol Biomed Life Sci 2014; 968:8-21. [DOI: 10.1016/j.jchromb.2014.02.049] [Citation(s) in RCA: 80] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2013] [Revised: 02/23/2014] [Accepted: 02/28/2014] [Indexed: 11/23/2022]
|
36
|
Perrenoud AGG, Farrell WP, Aurigemma CM, Aurigemma NC, Fekete S, Guillarme D. Evaluation of stationary phases packed with superficially porous particles for the analysis of pharmaceutical compounds using supercritical fluid chromatography. J Chromatogr A 2014; 1360:275-87. [DOI: 10.1016/j.chroma.2014.07.078] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2014] [Revised: 07/23/2014] [Accepted: 07/24/2014] [Indexed: 11/27/2022]
|
37
|
Supercritical fluid chromatography as a tool for enantioselective separation; A review. Anal Chim Acta 2014; 821:1-33. [DOI: 10.1016/j.aca.2014.02.036] [Citation(s) in RCA: 126] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2013] [Revised: 01/31/2014] [Accepted: 02/22/2014] [Indexed: 12/14/2022]
|