1
|
Kataoka H. In-tube solid-phase microextraction: Current trends and future perspectives. J Chromatogr A 2020; 1636:461787. [PMID: 33359971 DOI: 10.1016/j.chroma.2020.461787] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 12/02/2020] [Accepted: 12/04/2020] [Indexed: 01/01/2023]
Abstract
In-tube solid-phase microextraction (IT-SPME) was developed about 24 years ago as an effective sample preparation technique using an open tubular capillary column as an extraction device. IT-SPME is useful for micro-concentration, automated sample cleanup, and rapid online analysis, and can be used to determine the analytes in complex matrices simple sample processing methods such as direct sample injection or filtration. IT-SPME is usually performed in combination with high-performance liquid chromatography using an online column switching technology, in which the entire process from sample preparation to separation to data analysis is automated using the autosampler. Furthermore, IT-SPME minimizes the use of harmful organic solvents and is simple and labor-saving, making it a sustainable and environmentally friendly green analytical technique. Various operating systems and new sorbent materials have been developed to improve its extraction efficiency by, for example, enhancing its sorption capacity and selectivity. In addition, IT-SPME methods have been widely applied in environmental analysis, food analysis and bioanalysis. This review describes the present state of IT-SPME technology and summarizes its current trends and future perspectives, including method development and strategies to improve extraction efficiency.
Collapse
Affiliation(s)
- Hiroyuki Kataoka
- School of Pharmacy, Shujitsu University, Nishigawara, Okayama 703-8516, Japan.
| |
Collapse
|
2
|
Innovations in Extractive Phases for In-Tube Solid-Phase Microextraction Coupled to Miniaturized Liquid Chromatography: A Critical Review. Molecules 2020; 25:molecules25102460. [PMID: 32466305 PMCID: PMC7287690 DOI: 10.3390/molecules25102460] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 05/19/2020] [Accepted: 05/22/2020] [Indexed: 02/06/2023] Open
Abstract
Over the past years, a great effort has been devoted to the development of new sorbents that can be used to pack or to coat extractive capillaries for in-tube solid-phase microextraction (IT-SPME). Many of those efforts have been focused on the preparation of capillaries for miniaturized liquid chromatography (LC) due to the reduced availability of capillary columns with appropriate dimensions for this kind of system. Moreover, many of the extractive capillaries that have been used for IT-SPME so far are segments of open columns from the gas chromatography (GC) field, but the phase nature and dimensions are very limited. In particular, polar compounds barely interact with stationary GC phases. Capillary GC columns may also be unsuitable when highly selective extractions are needed. In this work, we provide an overview of the extractive capillaries that have been specifically developed for capillary LC (capLC) and nano LC (nanoLC) to enhance the overall performance of the IT-SPME, the chromatographic separation, and the detection. Different monolithic polymers, such as silica C18 and C8 polymers, molecularly imprinted polymers (MIPs), polymers functionalized with antibodies, and polymers reinforced with different types of carbon nanotubes, metal, and metal oxide nanoparticles (including magnetic nanoparticles), and restricted access materials (RAMs) will be presented and critically discussed.
Collapse
|
3
|
Rodríguez-Ramos R, Socas-Rodríguez B, Santana-Mayor Á, Rodríguez-Delgado MÁ. Nanomaterials as alternative dispersants for the multiresidue analysis of phthalates in soil samples using matrix solid phase dispersion prior to ultra-high performance liquid chromatography tandem mass spectrometry. CHEMOSPHERE 2019; 236:124377. [PMID: 31548171 DOI: 10.1016/j.chemosphere.2019.124377] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 06/04/2019] [Accepted: 07/14/2019] [Indexed: 06/10/2023]
Abstract
In this study, the application of different nanomaterials as dispersants in matrix solid phase dispersion has been evaluated for the extraction of fifteen phthalates from different environmental samples prior to their separation and quantification by ultra-high performance liquid chromatography coupled to triple quadrupole mass spectrometry. Within the evaluated nanomaterials, including graphene oxide, multi-walled carbon nanotubes and iron 1,3,5-benzenetricarboxylate metal-organic framework, the last one showed the best results in terms of extraction capacity and sample clean-up. The effects of the different parameters affecting the sample pretreatment efficiency were exhaustively evaluated. The whole methodology was validated for agricultural soil and sand, using dibutyl phthalate-3,4,5,6-d4 as surrogate. Recovery values ranged from 70 to 120% for both matrices with RSD values lower than 20% and the limits of quantification of the method achieved were in the range 0.14-2.7 μg/kg dry weight. Finally, the analysis of soil samples from different locations of Tenerife (Canary Islands, Spain) was carried out finding the presence of BBP, DIBP and DBP in the range 5-52 μg/kg dry weight in agricultural soils, and DIPP, DNOP and DINP in the range 2-101 μg/kg dry weight in sand samples.
Collapse
Affiliation(s)
- Ruth Rodríguez-Ramos
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias, Universidad de La Laguna (ULL). Avda. Astrofísico Fco. Sánchez, s/n, 38206, San Cristóbal de La Laguna, España
| | - Bárbara Socas-Rodríguez
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias, Universidad de La Laguna (ULL). Avda. Astrofísico Fco. Sánchez, s/n, 38206, San Cristóbal de La Laguna, España.
| | - Álvaro Santana-Mayor
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias, Universidad de La Laguna (ULL). Avda. Astrofísico Fco. Sánchez, s/n, 38206, San Cristóbal de La Laguna, España
| | - Miguel Ángel Rodríguez-Delgado
- Departamento de Química, Unidad Departamental de Química Analítica, Facultad de Ciencias, Universidad de La Laguna (ULL). Avda. Astrofísico Fco. Sánchez, s/n, 38206, San Cristóbal de La Laguna, España.
| |
Collapse
|
4
|
Fernández-Amado M, Prieto-Blanco M, López-Mahía P, Muniategui-Lorenzo S, Prada-Rodríguez D. Ion-pair in-tube solid phase microextraction for the simultaneous determination of phthalates and their degradation products in atmospheric particulate matter. J Chromatogr A 2017; 1520:35-47. [DOI: 10.1016/j.chroma.2017.09.010] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2017] [Revised: 08/23/2017] [Accepted: 09/03/2017] [Indexed: 12/31/2022]
|
5
|
Fernández-Amado M, Prieto-Blanco MC, López-Mahía P, Muniategui-Lorenzo S, Prada-Rodríguez D. A comparative study of extractant and chromatographic phases for the rapid and sensitive determination of six phthalates in rainwater samples. CHEMOSPHERE 2017; 175:52-65. [PMID: 28211335 DOI: 10.1016/j.chemosphere.2017.02.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2016] [Revised: 01/20/2017] [Accepted: 02/01/2017] [Indexed: 06/06/2023]
Abstract
Six phthalic acid esters were determined in rainwater samples, from which a very low sample volume was collected. This method combines on-line in-tube solid-phase microextraction coupled to high-performance liquid chromatography with a diode-array detector. In order to obtain a short analysis time and to reduce the consumption of organic solvents, two chromatographic phases (C18 monolithic and cyanopropyl silica) are compared. Although three critical pairs are found, faster separation, good resolution and lower pressures are achieved using C18 monolithic column. In order to achieve a simple and sensitive method, two commercial capillaries (a porous polymer with divinylbenzene-4-vinylpyridine and a liquid-phase capillary with 95% poly(dimethylsiloxane)-5% poly(diphenylsiloxane)) are tested for the extraction process. Due to great differences of hydrophobicity among the six phthalates, the selection of a modifier is necessary for a good extraction. The best conditions are achieved using 5 mL of sample containing 40% methanol in a 70 cm-long porous polymer capillary. The procedural blanks are controlled and taken into account in the calculation of the detection limits. Except for dimethylphthalate, the method detection limits are in the range from 0.2 to 0.9 ng mL-1 and the inter-day precision is between 5.3% and 12.5%. The recoveries were within the range of 71%-101%. Rainwater samples are analyzed in order to examine the dilution effect and washout of phthalates in the atmosphere. Dibutyl phthalate is the predominant phthalate found and di-(2-ethylhexyl) phthalate is detected in all analyzed samples.
Collapse
Affiliation(s)
- M Fernández-Amado
- Universidade da Coruña, Grupo QANAP, Instituto Universitario de Medio Ambiente (IUMA), Centro de Investigacións Científicas Avanzadas (CICA), Departamento de Química Analítica, Facultade de Ciencias, Zapateira, 15071 A Coruña, Spain
| | - M C Prieto-Blanco
- Universidade da Coruña, Grupo QANAP, Instituto Universitario de Medio Ambiente (IUMA), Centro de Investigacións Científicas Avanzadas (CICA), Departamento de Química Analítica, Facultade de Ciencias, Zapateira, 15071 A Coruña, Spain.
| | - P López-Mahía
- Universidade da Coruña, Grupo QANAP, Instituto Universitario de Medio Ambiente (IUMA), Centro de Investigacións Científicas Avanzadas (CICA), Departamento de Química Analítica, Facultade de Ciencias, Zapateira, 15071 A Coruña, Spain
| | - S Muniategui-Lorenzo
- Universidade da Coruña, Grupo QANAP, Instituto Universitario de Medio Ambiente (IUMA), Centro de Investigacións Científicas Avanzadas (CICA), Departamento de Química Analítica, Facultade de Ciencias, Zapateira, 15071 A Coruña, Spain
| | - D Prada-Rodríguez
- Universidade da Coruña, Grupo QANAP, Instituto Universitario de Medio Ambiente (IUMA), Centro de Investigacións Científicas Avanzadas (CICA), Departamento de Química Analítica, Facultade de Ciencias, Zapateira, 15071 A Coruña, Spain
| |
Collapse
|
6
|
Serra-Mora P, Moliner-Martínez Y, Molins-Legua C, Herráez-Hernández R, Verdú-Andrés J, Campíns-Falcó P. Trends in Online Intube Solid Phase Microextraction. COMPREHENSIVE ANALYTICAL CHEMISTRY 2017. [DOI: 10.1016/bs.coac.2017.01.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
7
|
Fernández-González V, Moscoso-Pérez C, Muniategui-Lorenzo S, López-Mahía P, Prada-Rodríguez D. Reliable, rapid and simple method for the analysis of phthalates in sediments by ultrasonic solvent extraction followed by head space-solid phase microextraction gas chromatography mass spectrometry determination. Talanta 2017; 162:648-653. [DOI: 10.1016/j.talanta.2016.10.068] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2016] [Revised: 10/14/2016] [Accepted: 10/17/2016] [Indexed: 11/16/2022]
|
8
|
Recent Advances in the Combination of Assisted Extraction Techniques. COMPREHENSIVE ANALYTICAL CHEMISTRY 2017. [DOI: 10.1016/bs.coac.2016.12.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
9
|
Determination of amphetamines in hair by integrating sample disruption, clean-up and solid phase derivatization. J Chromatogr A 2016; 1447:47-56. [DOI: 10.1016/j.chroma.2016.04.036] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Revised: 04/14/2016] [Accepted: 04/14/2016] [Indexed: 11/19/2022]
|
10
|
Fernández-Amado M, Prieto-Blanco M, López-Mahía P, Muniategui-Lorenzo S, Prada-Rodríguez D. Strengths and weaknesses of in-tube solid-phase microextraction: A scoping review. Anal Chim Acta 2016; 906:41-57. [DOI: 10.1016/j.aca.2015.12.007] [Citation(s) in RCA: 85] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2015] [Revised: 11/30/2015] [Accepted: 12/11/2015] [Indexed: 12/01/2022]
|
11
|
Moliner-Martinez Y, Herráez-Hernández R, Verdú-Andrés J, Molins-Legua C, Campíns-Falcó P. Recent advances of in-tube solid-phase microextraction. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2015.02.020] [Citation(s) in RCA: 105] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
12
|
Net S, Delmont A, Sempéré R, Paluselli A, Ouddane B. Reliable quantification of phthalates in environmental matrices (air, water, sludge, sediment and soil): a review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2015; 515-516:162-180. [PMID: 25723871 DOI: 10.1016/j.scitotenv.2015.02.013] [Citation(s) in RCA: 150] [Impact Index Per Article: 16.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/13/2014] [Revised: 02/04/2015] [Accepted: 02/04/2015] [Indexed: 06/04/2023]
Abstract
Because of their widespread application, phthalates or phthalic acid esters (PAEs) are ubiquitous in the environment. Their presence has attracted considerable attention due to their potential impacts on ecosystem functioning and on public health, so their quantification has become a necessity. Various extraction procedures as well as gas/liquid chromatography and mass spectrometry detection techniques are found as suitable for reliable detection of such compounds. However, PAEs are ubiquitous in the laboratory environment including ambient air, reagents, sampling equipment, and various analytical devices, that induces difficult analysis of real samples with a low PAE background. Therefore, accurate PAE analysis in environmental matrices is a challenging task. This paper reviews the extensive literature data on the techniques for PAE quantification in natural media. Sampling, sample extraction/pretreatment and detection for quantifying PAEs in different environmental matrices (air, water, sludge, sediment and soil) have been reviewed and compared. The concept of "green analytical chemistry" for PAE determination is also discussed. Moreover useful information about the material preparation and the procedures of quality control and quality assurance are presented to overcome the problem of sample contamination and these encountered due to matrix effects in order to avoid overestimating PAE concentrations in the environment.
Collapse
Affiliation(s)
- Sopheak Net
- Université Lille 1, Laboratoire LASIR-UMR 8516 CNRS, Equipe Physico-chimie de l'Environnement, Cité Scientifique 59655 Villeneuve d'Ascq, France.
| | - Anne Delmont
- Aix-Marseille University, Mediterranean Institute of Oceanography (M I O), UM 110, 13288, Marseille, Cedex 9, Université de Toulon, 83957, CNRS/IRD, France
| | - Richard Sempéré
- Aix-Marseille University, Mediterranean Institute of Oceanography (M I O), UM 110, 13288, Marseille, Cedex 9, Université de Toulon, 83957, CNRS/IRD, France
| | - Andrea Paluselli
- Aix-Marseille University, Mediterranean Institute of Oceanography (M I O), UM 110, 13288, Marseille, Cedex 9, Université de Toulon, 83957, CNRS/IRD, France
| | - Baghdad Ouddane
- Université Lille 1, Laboratoire LASIR-UMR 8516 CNRS, Equipe Physico-chimie de l'Environnement, Cité Scientifique 59655 Villeneuve d'Ascq, France
| |
Collapse
|