1
|
Gong X, Chen W, Zhang K, Li T, Song Q. Serially coupled column liquid chromatography: An alternative separation tool. J Chromatogr A 2023; 1706:464278. [PMID: 37572536 DOI: 10.1016/j.chroma.2023.464278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 07/20/2023] [Accepted: 08/02/2023] [Indexed: 08/14/2023]
Abstract
Despite the rapid development of liquid chromatography (LC) in recent decades, it remains a challenge to achieve the desired chromatographic separation of complex matrices using a single column. Multi-column LC techniques, particularly serially coupled column LC (SCC-LC), have emerged as a promising solution to overcome this challenge. While more attention has been focused on heart-cutting or comprehensive two-dimensional LC, reviews specifically focusing on SCC-LC, which offers advantages in terms of precision and facile instrumentation, are scarce. Here, our concerns are devoted to the progress summary regarding the instrumentation and applications of SCC-LC. Emphasis is placed on column selection aiming to enlarge peak capacity, selectivity, or both through the optimization of combination types (e.g. RPLC-RPLC, -RPLC-HILIC, and achiral-chiral LC), connection devices (e.g. zero dead volume connector, tubing, and T-type connector), elution program (i.e. isocratic or gradient) and detectors (e.g. mass spectrometer, ultraviolet detector, and fluorescence detector). The application of SCC-LC in pharmaceutical, biological, environmental, and food fields is also reviewed, and future perspectives and potential directions for SCC-LC are discussed. We envision that the review can give meaningful information to analytical scientists when facing heavy chromatographic separation tasks for complicated matrices.
Collapse
Affiliation(s)
- Xingcheng Gong
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China
| | - Wei Chen
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China
| | - Ke Zhang
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China
| | - Ting Li
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China
| | - Qingqing Song
- School of Chinese Materia Medica, Beijing University of Chinese Medicine, Beijing 102488, China.
| |
Collapse
|
2
|
Are Two Liquid Chromatography Columns in Tandem Better Than One?: Answers from the Hydrophobic Subtraction Model. J Chromatogr A 2022; 1668:462890. [DOI: 10.1016/j.chroma.2022.462890] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 02/03/2022] [Accepted: 02/08/2022] [Indexed: 11/19/2022]
|
3
|
Turnpenny P, Dickie A, Malec J, McClements J. Retention-directed and selectivity controlled chromatographic resolution: Rapid post-hoc analysis of DMPK samples to achieve high-throughput LC-MS separation. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1164:122514. [PMID: 33477099 DOI: 10.1016/j.jchromb.2020.122514] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 11/14/2020] [Accepted: 12/18/2020] [Indexed: 11/19/2022]
Abstract
High quality chromatographic separation underpins robustness in LC-MS, frequently the analytical method of choice for pharmaceutical drug discovery work. The potential improvements in chromatographic selectivity afforded by serial column coupling (SCC), provide a useful means to enhance the resolution of complex samples. In this work, we present a revised high-throughput form of SCC, in which just two individual mixed phase columns were coupled together and combined with a gradient-optimised, retention-directed ultra-high pressure method to achieve rapid separations, with no further method optimisation necessary. The overall performance was evaluated from an open access DMPK analytical working environment perspective; where in anticipation of bioanalytical or metabolite identification chromatography challenges, or with the knowledge that stronger resolution was required for in-vitro sample analysis, the methodology could be immediately implemented by the analyst. Retention-directed selection of a shallow SCC gradient method was successful in separating peaks throughout the chromatographic window, resulting in a runtime still congruent to high-throughput analyses (3.5 min). In-vitro assay sample interferences were resolved 44-72% of the time, and the overall resolving power for isomeric separations significantly improved against single column comparisons (1.7-fold mean RS improvement). Over a sustained period of time in our laboratory, SCC methods have been used for metabolite identification and bioanalytical samples, where both convenience and effectiveness in solving analytical challenges has been consistently demonstrated. Examples that highlight SCC chromatography, and a guided discussion of the main high-throughput considerations, are included. The technique offers wide applicability, and we would recommend it as a toolbox consideration to the laboratory analyst.
Collapse
Affiliation(s)
- Paul Turnpenny
- Evotec, Department of Drug Metabolism & Pharmacokinetics, Abingdon, Oxon, UK
| | - Anthony Dickie
- Evotec, Department of Drug Metabolism & Pharmacokinetics, Abingdon, Oxon, UK.
| | - Jed Malec
- Evotec, Department of Drug Metabolism & Pharmacokinetics, Abingdon, Oxon, UK
| | - Jordan McClements
- Evotec, Department of Drug Metabolism & Pharmacokinetics, Abingdon, Oxon, UK
| |
Collapse
|
4
|
Codesido S, Guillarme D, Fekete S. Algorithms to optimize multi-column chromatographic separations of proteins. J Chromatogr A 2020; 1637:461838. [PMID: 33422794 DOI: 10.1016/j.chroma.2020.461838] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 12/17/2020] [Accepted: 12/19/2020] [Indexed: 10/22/2022]
Abstract
The goal of this work was to provide a technical solution for the automated optimization of multi-column systems for protein separation and fractionation. Both algorithm and a software that can be downloaded are provided. In this algorithm, the length and order of the individual column segments can be considered. Various solutions are provided by the algorithm, including i) to obtain uniform peak distribution, ii) to park the different species at the inlet of the individual column segments, and iii) to elute all species as a single peak. Two representative examples are presented, showing the possibility to obtain uniform selectivity between monoclonal antibody (mAb) sub-units, and the on-column fractioning of intact mAbs.
Collapse
Affiliation(s)
- Santiago Codesido
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, 1211, Geneva 4, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, 1211, Geneva 4, Switzerland
| | - Davy Guillarme
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, 1211, Geneva 4, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, 1211, Geneva 4, Switzerland
| | - Szabolcs Fekete
- Institute of Pharmaceutical Sciences of Western Switzerland (ISPSO), University of Geneva, CMU-Rue Michel Servet 1, 1211, Geneva 4, Switzerland; School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, 1211, Geneva 4, Switzerland.
| |
Collapse
|
5
|
Huygens B, Efthymiadis K, Nowé A, Desmet G. Application of evolutionary algorithms to optimise one- and two-dimensional gradient chromatographic separations. J Chromatogr A 2020; 1628:461435. [PMID: 32822975 DOI: 10.1016/j.chroma.2020.461435] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 07/09/2020] [Accepted: 07/27/2020] [Indexed: 11/30/2022]
Abstract
We report on the performance of three classes of evolutionary algorithms (genetic algorithms (GA), evolution strategies (ES) and covariance matrix adaptation evolution strategy (CMA-ES)) as a means to enhance searches in the method development spaces of 1D- and 2D-chromatography. After optimisation of the design parameters of the different algorithms, they were benchmarked against the performance of a plain grid search. It was found that all three classes significantly outperform the plain grid search, especially in terms of the number of search runs needed to achieve a given separation quality. As soon as more than 100 search runs are needed, the ES algorithm clearly outperforms the GA and CMA-ES algorithms, with the latter performing very well for short searches (<50 search runs) but being susceptible to convergence to local optima for longer searches. It was also found that the performance of the ES and GA algorithms, as well as the grid search, follow a hyperbolic law in the large search run number limit, such that the convergence rate parameter of this hyperbolic function can be used to quantify the difference in required number of search runs for these algorithms. In agreement with one's physical expectations, it was also found that the general advantage of the GA and ES algorithms over the grid search, as well as their mutual performance differences, grow with increasing difficulty of the separation problem.
Collapse
Affiliation(s)
- Bram Huygens
- Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, 1050 Brussels, Belgium
| | - Kyriakos Efthymiadis
- Vrije Universiteit Brussel, Artificial Intelligence Lab, Pleinlaan 2, 1050 Brussels, Belgium
| | - Ann Nowé
- Vrije Universiteit Brussel, Artificial Intelligence Lab, Pleinlaan 2, 1050 Brussels, Belgium
| | - Gert Desmet
- Vrije Universiteit Brussel, Department of Chemical Engineering, Pleinlaan 2, 1050 Brussels, Belgium.
| |
Collapse
|
6
|
Enhancement in the computation of gradient retention times in liquid chromatography using root-finding methods. J Chromatogr A 2019; 1600:137-147. [DOI: 10.1016/j.chroma.2019.04.030] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Revised: 04/10/2019] [Accepted: 04/11/2019] [Indexed: 12/12/2022]
|
7
|
Navarro-Huerta JA, Gisbert-Alonso A, Torres-Lapasió JR, García-Alvarez-Coque MC. Benefits of solvent concentration pulses in retention time modelling of liquid chromatography. J Chromatogr A 2019; 1597:76-88. [PMID: 30902430 DOI: 10.1016/j.chroma.2019.03.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2019] [Revised: 03/07/2019] [Accepted: 03/10/2019] [Indexed: 01/15/2023]
Abstract
The advantages and disadvantages of the use of isocratic experimental designs including transient increments of organic solvent (i.e., pulses) in the mobile phase(s) of lowest elution strength are explored with modelling purposes. For retained solutes, this type of mixed design offers similar or better predictive capability than gradient designs, shorter measurement time than pure isocratic designs, and retention model parameters that agree with those derived from pure isocratic experiments, with similar uncertainties. The predicted retention times are comparable to those offered by models adjusted from pure isocratic designs, and the solvent waste is appreciably lower. Under a practical standpoint, mixed designs including pulse(s) can be easily constructed by replacing the slowest isocratic runs with runs containing a pulse of short duration at an intermediate time. This allows the elution of the fastest solutes with appreciable retention in the initial sector of the elution program, previous to the pulse, and the elution of the slow solutes after the pulse, also in acceptable times. The fitting of the retention data obtained with pulses is simpler compared to gradient elution, and involves solving the integral equation of gradient elution, simplified by the presence of isocratic sectors. Experiments involving pulses reveal the existence of discrepancies in the predictions for solutes eluting in the nearby of the pulse, offered by the fundamental equation of gradient elution when this is solved using numerical integration. The correction of such discrepancies implies the inclusion of intra-column delays, in the arrival of changes in the concentration of organic modifier in the gradient to the instantaneous position of the solute, along the whole migration.
Collapse
Affiliation(s)
- J A Navarro-Huerta
- Department of Analytical Chemistry, Faculty of Chemistry, Universitat de València, c/ Dr. Moliner 50, 46100, Burjassot, Spain
| | - A Gisbert-Alonso
- Department of Analytical Chemistry, Faculty of Chemistry, Universitat de València, c/ Dr. Moliner 50, 46100, Burjassot, Spain
| | - J R Torres-Lapasió
- Department of Analytical Chemistry, Faculty of Chemistry, Universitat de València, c/ Dr. Moliner 50, 46100, Burjassot, Spain.
| | - M C García-Alvarez-Coque
- Department of Analytical Chemistry, Faculty of Chemistry, Universitat de València, c/ Dr. Moliner 50, 46100, Burjassot, Spain
| |
Collapse
|
8
|
Alvarez-Segura T, Torres-Lapasió JR, García-Alvarez-Coque MC. Updating chromatographic predictions by accounting ageing for single and tandem columns. J Sep Sci 2018; 41:2719-2730. [DOI: 10.1002/jssc.201800264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2018] [Revised: 04/18/2018] [Accepted: 04/26/2018] [Indexed: 11/11/2022]
|
9
|
Gradient design for liquid chromatography using multi-scale optimization. J Chromatogr A 2018; 1534:32-42. [DOI: 10.1016/j.chroma.2017.12.040] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Revised: 12/12/2017] [Accepted: 12/15/2017] [Indexed: 11/23/2022]
|
10
|
Alvarez-Segura T, Camacho-Molinero C, Torres-Lapasió JR, García-Alvarez-Coque MC. Analysis of amino acids using serially coupled columns. J Sep Sci 2017; 40:2741-2751. [PMID: 28520236 DOI: 10.1002/jssc.201700334] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2017] [Revised: 05/05/2017] [Accepted: 05/08/2017] [Indexed: 11/10/2022]
Abstract
Single conventional columns in reversed-phase liquid chromatography are insufficient for analysing the isoindoles of primary amino acids due to their limited functionality. An interesting possibility for increasing the separation power is the combination of several columns of different nature, where the length is modified by coupling small segments. This approach may require a considerable investment to have multiple lengths for each stationary phase. However, the combination of only two columns of fixed length can be enough to resolve satisfactorily relatively complex mixtures, provided that an optimised gradient program is applied. In this work, a mixture of 19 primary amino acid isoindoles found in proteins was analysed. Four stationary phases were assayed: C18, pentafluorophenyl-C18, C4 and cyano. The mixture of isoindoles was successfully resolved in practical times using a pentafluorophenyl-C18 column coupled to a C4 column, in spite of the extremely poor performance obtained when each column is used isolatedly, independently of the length. The extreme diversity in the polarities of the isoindoles and the need of extrapolating the retention behaviour in certain regions of the solvent content domain makes the modelling of the retention behaviour of the isoindoles particularly difficult. Nevertheless, the predicted optimal separations were very satisfactory.
Collapse
|
11
|
Stationary phase modulation in liquid chromatography through the serial coupling of columns: A review. Anal Chim Acta 2016; 923:1-23. [DOI: 10.1016/j.aca.2016.03.040] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2015] [Revised: 03/17/2016] [Accepted: 03/21/2016] [Indexed: 01/22/2023]
|