1
|
Pereira F, López R, Rodríguez-Cordero A, Robles L, Suárez D, Aller A. New models involving quantum chemical parameters for assessing the chromatographic retention process. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
2
|
den Uijl MJ, Schoenmakers PJ, Schulte GK, Stoll DR, van Bommel MR, Pirok BWJ. Measuring and using scanning-gradient data for use in method optimization for liquid chromatography. J Chromatogr A 2020; 1636:461780. [PMID: 33360860 DOI: 10.1016/j.chroma.2020.461780] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 11/23/2020] [Accepted: 11/29/2020] [Indexed: 12/27/2022]
Abstract
The use of scanning gradients can significantly reduce method-development time in reversed-phase liquid chromatography. However, there is no consensus on how they can best be used. In the present work we set out to systematically investigate various factors and to formulate guidelines. Scanning gradients are used to establish retention models for individual analytes. Different retention models were compared by computing the Akaike information criterion and the prediction accuracy. The measurement uncertainty was found to influence the optimum choice of model. The use of a third parameter to account for non-linear relationships was consistently found not to be statistically significant. The duration (slope) of the scanning gradients was not found to influence the accuracy of prediction. The prediction error may be reduced by repeating scanning experiments or - preferably - by reducing the measurement uncertainty. It is commonly assumed that the gradient-slope factor, i.e. the ratio between slopes of the fastest and the slowest scanning gradients, should be at least three. However, in the present work we found this factor less important than the proximity of the slope of the predicted gradient to that of the scanning gradients. Also, interpolation to a slope between that of the fastest and the slowest scanning gradient is preferable to extrapolation. For comprehensive two-dimensional liquid chromatography (LC × LC) our results suggest that data obtained from fast second-dimension gradients cannot be used to predict retention in much slower first-dimension gradients.
Collapse
Affiliation(s)
- Mimi J den Uijl
- University of Amsterdam, van 't Hoff Institute for Molecular Sciences, Analytical-Chemistry Group, Science Park 904, 1098 XH Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), The Netherlands.
| | - Peter J Schoenmakers
- University of Amsterdam, van 't Hoff Institute for Molecular Sciences, Analytical-Chemistry Group, Science Park 904, 1098 XH Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), The Netherlands
| | - Grace K Schulte
- Department of Chemistry, Gustavus Adolphus College, Saint Peter, Minnesota 56082, USA
| | - Dwight R Stoll
- Department of Chemistry, Gustavus Adolphus College, Saint Peter, Minnesota 56082, USA
| | - Maarten R van Bommel
- University of Amsterdam, van 't Hoff Institute for Molecular Sciences, Analytical-Chemistry Group, Science Park 904, 1098 XH Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), The Netherlands; University of Amsterdam, Amsterdam School for Heritage, Memory and Material Culture, Conservation and Restoration of Cultural Heritage, Johannes Vermeerplein 1, 1071 DV Amsterdam, the Netherlands
| | - Bob W J Pirok
- University of Amsterdam, van 't Hoff Institute for Molecular Sciences, Analytical-Chemistry Group, Science Park 904, 1098 XH Amsterdam, the Netherlands; Centre for Analytical Sciences Amsterdam (CASA), The Netherlands; Department of Chemistry, Gustavus Adolphus College, Saint Peter, Minnesota 56082, USA
| |
Collapse
|
3
|
den Uijl MJ, Schoenmakers PJ, Pirok BWJ, van Bommel MR. Recent applications of retention modelling in liquid chromatography. J Sep Sci 2020; 44:88-114. [PMID: 33058527 PMCID: PMC7821232 DOI: 10.1002/jssc.202000905] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 10/02/2020] [Accepted: 10/12/2020] [Indexed: 11/18/2022]
Abstract
Recent applications of retention modelling in liquid chromatography (2015–2020) are comprehensively reviewed. The fundamentals of the field, which date back much longer, are summarized. Retention modeling is used in retention‐mechanism studies, for determining physical parameters, such as lipophilicity, and for various more‐practical purposes, including method development and optimization, method transfer, and stationary‐phase characterization and comparison. The review focusses on the effects of mobile‐phase composition on retention, but other variables and novel models to describe their effects are also considered. The five most‐common models are addressed in detail, i.e. the log‐linear (linear‐solvent‐strength) model, the quadratic model, the log–log (adsorption) model, the mixed‐mode model, and the Neue–Kuss model. Isocratic and gradient‐elution methods are considered for determining model parameters and the evaluation and validation of fitted models is discussed. Strategies in which retention models are applied for developing and optimizing one‐ and two‐dimensional liquid chromatographic separations are discussed. The review culminates in some overall conclusions and several concrete recommendations.
Collapse
Affiliation(s)
- Mimi J den Uijl
- Analytical Chemistry Group, van 't Hoff Institute for Molecular Sciences, University of Amsterdam, Amsterdam, The Netherlands.,Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, The Netherlands
| | - Peter J Schoenmakers
- Analytical Chemistry Group, van 't Hoff Institute for Molecular Sciences, University of Amsterdam, Amsterdam, The Netherlands.,Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, The Netherlands
| | - Bob W J Pirok
- Analytical Chemistry Group, van 't Hoff Institute for Molecular Sciences, University of Amsterdam, Amsterdam, The Netherlands.,Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, The Netherlands
| | - Maarten R van Bommel
- Analytical Chemistry Group, van 't Hoff Institute for Molecular Sciences, University of Amsterdam, Amsterdam, The Netherlands.,Centre for Analytical Sciences Amsterdam (CASA), Amsterdam, The Netherlands.,University of Amsterdam, Faculty of Humanities, Conservation and Restoration of Cultural Heritage, Amsterdam, The Netherlands
| |
Collapse
|
4
|
Simultaneous optimization of pH and binary organic composition by grid form modeling of the retention behavior in reversed-phase ultra high-performance liquid chromatography. J Pharm Biomed Anal 2017; 146:251-260. [DOI: 10.1016/j.jpba.2017.08.047] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2017] [Revised: 08/26/2017] [Accepted: 08/29/2017] [Indexed: 11/20/2022]
|
5
|
Sykora D, Vozka J, Tesarova E. Chromatographic methods enabling the characterization of stationary phases and retention prediction in high-performance liquid chromatography and supercritical fluid chromatography. J Sep Sci 2015; 39:115-31. [DOI: 10.1002/jssc.201501023] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2015] [Revised: 10/08/2015] [Accepted: 10/08/2015] [Indexed: 11/11/2022]
Affiliation(s)
- David Sykora
- Department of Analytical Chemistry; University of Chemistry and Technology; Prague Czech Republic
| | - Jiri Vozka
- Department of Analytical Chemistry; University of Chemistry and Technology; Prague Czech Republic
- Department of Physical and Macromolecular Chemistry, Faculty of Science; Charles University in Prague; Prague Czech Republic
| | - Eva Tesarova
- Department of Physical and Macromolecular Chemistry, Faculty of Science; Charles University in Prague; Prague Czech Republic
| |
Collapse
|
6
|
Wiczling P, Kubik Ł, Kaliszan R. Maximum A Posteriori Bayesian Estimation of Chromatographic Parameters by Limited Number of Experiments. Anal Chem 2015; 87:7241-9. [DOI: 10.1021/acs.analchem.5b01195] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Paweł Wiczling
- Department of Biopharmaceutics
and Pharmacodynamics, Medical University of Gdańsk, Gen.
J. Hallera 107, 80-416 Gdańsk, Poland
| | - Łukasz Kubik
- Department of Biopharmaceutics
and Pharmacodynamics, Medical University of Gdańsk, Gen.
J. Hallera 107, 80-416 Gdańsk, Poland
| | - Roman Kaliszan
- Department of Biopharmaceutics
and Pharmacodynamics, Medical University of Gdańsk, Gen.
J. Hallera 107, 80-416 Gdańsk, Poland
| |
Collapse
|