1
|
Douma C, Bowser MT. Assessing Surface Adsorption in Cyclic Olefin Copolymer Microfluidic Devices Using Two-Dimensional Nano Liquid Chromatography-Micro Free Flow Electrophoresis Separations. Anal Chem 2023; 95:18379-18387. [PMID: 38060457 PMCID: PMC10733905 DOI: 10.1021/acs.analchem.3c03014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 10/11/2023] [Accepted: 10/18/2023] [Indexed: 12/20/2023]
Abstract
Surface interactions are a concern in microscale separations, where analyte adsorption can decrease the speed, sensitivity, and resolution otherwise achieved by miniaturization. Here, we functionally characterize the surface adsorption of hot-embossed cyclic olefin copolymer (COC) micro free-flow electrophoresis (μFFE) devices using two-dimensional nLC × μFFE separations, which introduce a 3- to 5 s plug of analyte into the device and measure temporal broadening that arises from surface interactions. COC is an attractive material for microfluidic devices, but little is known about its potential for surface adsorption in applications with continuous fluid flow and temporal measurements. Adsorption was minimal for three small molecule dyes: positively charged rhodamine 123, negatively charged fluorescein, and neutral rhodamine 110. Temporal peak widths for the three dyes ranged from 3 to 7 s and did not change significantly with increasing transit distance. Moderate adsorption was observed for Chromeo P503-labeled myoglobin and cytochrome c with temporal peak widths around 20 s. Overall, the COC surface adsorption was low compared to traditional glass devices, where peak widths are on the order of minutes. Improvements in durability, long-term performance, and ease of fabrication, combined with low overall adsorption, make the COC μFFE devices a practical choice for applications involving time-resolved continuous detection.
Collapse
Affiliation(s)
- Cecilia
C. Douma
- Department of Chemistry, University
of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - Michael T. Bowser
- Department of Chemistry, University
of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
2
|
Microfluidic free-flow electrophoresis: a promising tool for protein purification and analysis in proteomics. J IND ENG CHEM 2022. [DOI: 10.1016/j.jiec.2022.02.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
3
|
Thormann W, Mosher RA. Dynamic computer simulations of electrophoresis: 2010-2020. Electrophoresis 2021; 43:10-36. [PMID: 34287996 PMCID: PMC9292373 DOI: 10.1002/elps.202100191] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 07/12/2021] [Accepted: 07/15/2021] [Indexed: 02/05/2023]
Abstract
The transport of components in liquid media under the influence of an applied electric field can be described with the continuity equation. It represents a nonlinear conservation law that is based upon the balance laws of continuous transport processes and can be solved in time and space numerically. This procedure is referred to as dynamic computer simulation. Since its inception four decades ago, the state of dynamic computer simulation software and its use has progressed significantly. Dynamic models are the most versatile tools to explore the fundamentals of electrokinetic separations and provide insights into the behavior of buffer systems and sample components of all electrophoretic separation methods, including moving boundary electrophoresis, CZE, CGE, ITP, IEF, EKC, ACE, and CEC. This article is a continuation of previous reviews (Electrophoresis 2009, 30, S16–S26 and Electrophoresis 2010, 31, 726–754) and summarizes the progress and achievements made during the 2010 to 2020 time period in which some of the existing dynamic simulators were extended and new simulation packages were developed. This review presents the basics and extensions of the three most used one‐dimensional simulators, provides a survey of new one‐dimensional simulators, outlines an overview of multi‐dimensional models, and mentions models that were briefly reported in the literature. A comprehensive discussion of simulation applications and achievements of the 2010 to 2020 time period is also included.
Collapse
Affiliation(s)
- Wolfgang Thormann
- Institute for Infectious Diseases, University of Bern, Bern, Switzerland
| | | |
Collapse
|
4
|
Dong S, Jiang Z, Liu Z, Chen L, Zhang Q, Tian Y, Sohail A, Khan MI, Xiao H, Liu X, Wang Y, Li H, Wu H, Liu W, Cao C. Purification of low-abundance lysozyme in egg white via free-flow electrophoresis with gel-filtration chromatography. Electrophoresis 2020; 41:1529-1538. [PMID: 32529672 DOI: 10.1002/elps.201900479] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2019] [Revised: 05/29/2020] [Accepted: 05/31/2020] [Indexed: 11/07/2022]
Abstract
As an effective separation tool, free-flow electrophoresis has not been used for purification of low-abundance protein in complex sample matrix. Herein, lysozyme in complex egg white matrix was chosen as the model protein for demonstrating the purification of low-content peptide via an FFE coupled with gel fitration chromatography (GFC). The crude lysozyme in egg while was first separated via free-flow zone electrophoresis (FFZE). After that, the fractions with lysozyme activity were condensed via lyophilization. Thereafter, the condensed fractions were further purified via a GFC of Sephadex G50. In all of the experiments, a special poly(acrylamide- co-acrylic acid) (P(AM-co-AA)) gel electrophoresis and a mass spectrometry were used for identification of lysozyme. The conditions of FFZE were optimized as follows: 130 μL/min sample flow rate, 4.9 mL/min background buffer of 20 mM pH 5.5 Tris-Acetic acid, 350 V, and 14 °C as well as 2 mg/mL protein content of crude sample. It was found that the purified lysozyme had the purity of 80% and high activity as compared with its crude sample with only 1.4% content and undetectable activity. The recoveries in the first and second separative steps were 65% and 82%, respectively, and the total recovery was about 53.3%. The reasons of low recovery might be induced by diffusion of lysozyme out off P(AM-co-AA) gel and co-removing of high-abundance egg ovalbumin. All these results indicated FFE could be used as alternative tool for purification of target solute with low abundance.
Collapse
Affiliation(s)
- Shuang Dong
- Department of Instrument Science and Engineering, School of Electronic Information & Electrical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China.,State Key Laboratory of Microbial Metabolism, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Ziqin Jiang
- College of Biological Sciences, China Agricultural University, Beijing, P. R. China.,State Key Laboratory of Agro-biotechnology, China Agricultural University, Beijing, P. R. China
| | - Zhen Liu
- Department of Instrument Science and Engineering, School of Electronic Information & Electrical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China.,State Key Laboratory of Microbial Metabolism, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Ling Chen
- Department of Instrument Science and Engineering, School of Electronic Information & Electrical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Qiang Zhang
- Department of Instrument Science and Engineering, School of Electronic Information & Electrical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Youli Tian
- Department of Instrument Science and Engineering, School of Electronic Information & Electrical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Amir Sohail
- Department of Instrument Science and Engineering, School of Electronic Information & Electrical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Muhammad Idrees Khan
- Department of Instrument Science and Engineering, School of Electronic Information & Electrical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Hua Xiao
- State Key Laboratory of Microbial Metabolism, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Xiaoping Liu
- Department of Instrument Science and Engineering, School of Electronic Information & Electrical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Yuxing Wang
- School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Honggen Li
- School of Physics and Astronomy, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Hanyu Wu
- College of Biological Sciences, China Agricultural University, Beijing, P. R. China.,State Key Laboratory of Agro-biotechnology, China Agricultural University, Beijing, P. R. China
| | - Weiwen Liu
- Department of Instrument Science and Engineering, School of Electronic Information & Electrical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China
| | - Chengxi Cao
- Department of Instrument Science and Engineering, School of Electronic Information & Electrical Engineering, Shanghai Jiao Tong University, Shanghai, P. R. China.,State Key Laboratory of Microbial Metabolism, Shanghai Jiao Tong University, Shanghai, P. R. China
| |
Collapse
|
5
|
Stastna M. Continuous flow electrophoretic separation - Recent developments and applications to biological sample analysis. Electrophoresis 2019; 41:36-55. [PMID: 31650578 DOI: 10.1002/elps.201900288] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Revised: 10/08/2019] [Accepted: 10/10/2019] [Indexed: 01/23/2023]
Abstract
Continuous flow electrophoretic separation with continuous sample loading provides the advantage of processing volumes of any sizes, as well as the benefit of a real-time monitoring and optimization of the separation process. In addition, the spatial separation of the sample enables collecting multiple separated components simultaneously and in a continuous manner. The separation is usually performed in mild buffers without organic solvents and detergents (sample biological activity is retained) and it is carried out without usage of a solid support in the separation space preventing the interaction of the sample with it (high sample recovery). The method is used for the separation of proteins/peptides in proteomic applications, and its great applicability is to the separation of the cells, cellular organelles, vesicles, membrane fragments, and DNA. This review focuses on the electrophoretic separation performed in a continuous flow and it describes various electrophoretic modes and instrumental setups. Recent developments in methodology and instrumentation, the integration with other techniques, and the application to the biological sample analysis are discussed as well.
Collapse
Affiliation(s)
- Miroslava Stastna
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Brno, Czech Republic
| |
Collapse
|
6
|
Wang S, Zhang L, Sun H, Chu Z, Chen H, Zhao Y, Zhang W. Carrier ampholyte-free free-flow isoelectric focusing for separation of protein. Electrophoresis 2019; 40:2610-2617. [PMID: 30977523 DOI: 10.1002/elps.201900148] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2019] [Accepted: 04/06/2019] [Indexed: 01/20/2023]
Abstract
Free-flow isoelectric focusing (FFIEF) has the merits of mild separation conditions, high recovery and resolution, but suffers from the issues of ampholytes interference and high cost due to expensive carrier ampholytes. In this paper, a home-made carrier ampholyte-free FFIEF system was constructed via orientated migration of H+ and OH- provided by electrode solutions. When applying an electric field, a linear pH gradient from pH 4 to 9 (R2 = 0.994) was automatically formed by the electromigration of protons and hydroxyl ions in the separation chamber. The carrier ampholyte-free FFIEF system not only avoids interference of ampholyte to detection but also guarantees high separation resolution by establishing stable pH gradient. The separation selectivity was conveniently adjusted by controlling operating voltage and optimizing the composition, concentration and flow rate of the carrier buffer. The constructed system was applied to separation of proteins in egg white, followed by MADLI-TOF-MS identification. Three major proteins, ovomucoid, ovalbumin and ovotransferrin, were successfully separated according to their pI values with 15 mmol/L Tris-acetic acid (pH = 6.5) as carrier buffer at a flow rate of 12.9 mL/min.
Collapse
Affiliation(s)
- Shuai Wang
- Shanghai Key Laboratory of Functional Materials Chemistry, East China University of Science and Technology, Shanghai, P. R. China
| | - Lingyi Zhang
- Shanghai Key Laboratory of Functional Materials Chemistry, East China University of Science and Technology, Shanghai, P. R. China
| | - Haofan Sun
- Shanghai Key Laboratory of Functional Materials Chemistry, East China University of Science and Technology, Shanghai, P. R. China
| | - Zhanying Chu
- Shanghai Key Laboratory of Functional Materials Chemistry, East China University of Science and Technology, Shanghai, P. R. China
| | - Haihong Chen
- Shanghai Key Laboratory of Functional Materials Chemistry, East China University of Science and Technology, Shanghai, P. R. China
| | - Yameng Zhao
- Shanghai Key Laboratory of Functional Materials Chemistry, East China University of Science and Technology, Shanghai, P. R. China
| | - Weibing Zhang
- Shanghai Key Laboratory of Functional Materials Chemistry, East China University of Science and Technology, Shanghai, P. R. China
| |
Collapse
|
7
|
Šalplachta J, Horká M, Šlais K. Capillary electrophoresis with preparative isoelectric focusing preconcentration for sensitive determination of amphotericin B in human blood serum. Anal Chim Acta 2019; 1053:162-168. [DOI: 10.1016/j.aca.2018.12.010] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2018] [Revised: 11/06/2018] [Accepted: 12/09/2018] [Indexed: 12/15/2022]
|
8
|
Srinivas PR. Introduction to Protein Electrophoresis. Methods Mol Biol 2019; 1855:23-29. [PMID: 30426403 DOI: 10.1007/978-1-4939-8793-1_2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
This chapter briefly discusses the developments in electrophoresis of proteins from Tiselius' moving-boundary electrophoresis to the modern-day two-dimensional polyacrylamide gel electrophoresis. It also touches upon the staining methods used to visualize total proteins post electrophoresis.
Collapse
Affiliation(s)
- Pothur R Srinivas
- National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD, USA.
| |
Collapse
|
9
|
Islinger M, Wildgruber R, Völkl A. Preparative free-flow electrophoresis, a versatile technology complementing gradient centrifugation in the isolation of highly purified cell organelles. Electrophoresis 2018; 39:2288-2299. [DOI: 10.1002/elps.201800187] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2018] [Accepted: 05/01/2018] [Indexed: 12/13/2022]
Affiliation(s)
- Markus Islinger
- Institute for Neuroanatomy, Centre for Biomedicine and Medical Technology Mannheim, Medical Faculty Mannheim; University of Heidelberg; Heidelberg Germany
| | | | - Alfred Völkl
- Department of Medical Cell Biology; Institute of Anatomy; University of Heidelberg; Heidelberg Germany
| |
Collapse
|
10
|
Abstract
Micro free-flow electrophoresis (μFFE) is a continuous separation technique in which analytes are streamed through a perpendicularly applied electric field in a planar separation channel. Analyte streams are deflected laterally based on their electrophoretic mobilities as they flow through the separation channel. A number of μFFE separation modes have been demonstrated, including free zone (FZ), micellar electrokinetic chromatography (MEKC), isoelectric focusing (IEF) and isotachophoresis (ITP). Approximately 60 articles have been published since the first μFFE device was fabricated in 1994. We anticipate that recent advances in device design, detection, and fabrication, will allow μFFE to be applied to a much wider range of applications. Applications particularly well suited for μFFE analysis include continuous, real time monitoring and microscale purifications.
Collapse
Affiliation(s)
- Alexander C Johnson
- Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, MN 55455, USA.
| | | |
Collapse
|
11
|
Xia ZJ, Liu Z, Kong FZ, Fan LY, Xiao H, Cao CX. Comparison of antimicrobial peptide purification via free-flow electrophoresis and gel filtration chromatography. Electrophoresis 2017; 38:3147-3154. [DOI: 10.1002/elps.201700187] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2017] [Revised: 08/01/2017] [Accepted: 08/02/2017] [Indexed: 01/30/2023]
Affiliation(s)
- Zhi-Jun Xia
- Laboratory of Analytical Biochemistry and Bioseparation; State Key Laboratory of Microbial Metabolism; School of Life Science and Biotechnology; Shanghai Jiao Tong University; Shanghai P. R. China
| | - Zhen Liu
- Laboratory of Analytical Biochemistry and Bioseparation; State Key Laboratory of Microbial Metabolism; School of Life Science and Biotechnology; Shanghai Jiao Tong University; Shanghai P. R. China
| | - Fan-Zhi Kong
- Laboratory of Analytical Biochemistry and Bioseparation; State Key Laboratory of Microbial Metabolism; School of Life Science and Biotechnology; Shanghai Jiao Tong University; Shanghai P. R. China
| | - Liu-Yin Fan
- Laboratory of Analytical Biochemistry and Bioseparation; State Key Laboratory of Microbial Metabolism; School of Life Science and Biotechnology; Shanghai Jiao Tong University; Shanghai P. R. China
| | - Hua Xiao
- Laboratory of Analytical Biochemistry and Bioseparation; State Key Laboratory of Microbial Metabolism; School of Life Science and Biotechnology; Shanghai Jiao Tong University; Shanghai P. R. China
| | - Cheng-Xi Cao
- Laboratory of Analytical Biochemistry and Bioseparation; State Key Laboratory of Microbial Metabolism; School of Life Science and Biotechnology; Shanghai Jiao Tong University; Shanghai P. R. China
| |
Collapse
|
12
|
He YC, Kong FZ, Fan LY, Wu JY, Liu XP, Li J, Sun Y, Zhang Q, Yang Y, Wu XJ, Xiao H, Cao CX. Preparation of intact mitochondria using free-flow isoelectric focusing with post-pH gradient sample injection for morphological, functional and proteomics studies. Anal Chim Acta 2017; 982:200-208. [DOI: 10.1016/j.aca.2017.06.007] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2016] [Revised: 06/10/2017] [Accepted: 06/13/2017] [Indexed: 12/31/2022]
|
13
|
Kong F, Zhang M, Chen J, Fan L, Xiao H, Liu S, Cao C. Continuous protein concentration via free-flow moving reaction boundary electrophoresis. J Chromatogr A 2017; 1508:169-175. [DOI: 10.1016/j.chroma.2017.06.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2017] [Revised: 05/31/2017] [Accepted: 06/02/2017] [Indexed: 10/19/2022]
|
14
|
Dawod M, Arvin NE, Kennedy RT. Recent advances in protein analysis by capillary and microchip electrophoresis. Analyst 2017; 142:1847-1866. [PMID: 28470231 PMCID: PMC5516626 DOI: 10.1039/c7an00198c] [Citation(s) in RCA: 91] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
This review article describes the significant recent advances in the analysis of proteins by capillary and microchip electrophoresis during the period from mid-2014 to early 2017. This review highlights the progressions, new methodologies, innovative instrumental modifications, and challenges for efficient protein analysis in human specimens, animal tissues, and plant samples. The protein analysis fields covered in this review include analysis of native, reduced, and denatured proteins in addition to Western blotting, protein therapeutics and proteomics.
Collapse
Affiliation(s)
- Mohamed Dawod
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, Michigan 48109, USA.
| | | | | |
Collapse
|
15
|
Johnson AC, Bowser MT. High-Speed, Comprehensive, Two Dimensional Separations of Peptides and Small Molecule Biological Amines Using Capillary Electrophoresis Coupled with Micro Free Flow Electrophoresis. Anal Chem 2017; 89:1665-1673. [PMID: 27989118 DOI: 10.1021/acs.analchem.6b03768] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Two-dimensional (2D) separations are able to generate significantly higher peak capacities than their one-dimensional counterparts. Unfortunately, current hyphenated 2D separations are limited by the speed of the second dimension separation and the consequent loss of peak capacity due to under sampling of peaks as they elute from the first dimension separation. Continuous micro free flow electrophoresis (μFFE) separations eliminate under sampling as a limitation when incorporated as the second dimension of a 2D separation. In the current manuscript we describe the first coupling of capillary electrophoresis (CE) with μFFE to perform 2D CE × μFFE separations. The CE separation capillary was directly inserted into the μFFE separation channel using an edge on interface. Analyte peaks streamed directly into the μFFE separation channel as they migrated off the CE capillary. No complicated injection, valving, or voltage changes were necessary to couple the two separation modes. 2D CE × μFFE generated an ideal peak capacity of 2 592 in a 9 min separation of fluorescently labeled peptides (7.6 min separation window, 342 peaks/min). Data points were recorded every 250-500 ms (>8 data points/peak), effectively eliminating under sampling as a source of band broadening. CE × μFFE generated an ideal peak capacity of 1885 in a 2.7 min separation of fluorescently labeled small molecule bioamines (1.8 min separation window, 1053 peaks/min). Peaks in the 2D CE × μFFE separation of peptides covered 30% of the available separation space, resulting in a corrected peak capacity of 778 (102 peaks/min). The fractional coverage of the 2D CE × μFFE separation of small molecule bioamines was 20%, resulting in a corrected peak capacity of 377 (209 peaks/min).
Collapse
Affiliation(s)
- Alexander C Johnson
- University of Minnesota , Department of Chemistry, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| | - Michael T Bowser
- University of Minnesota , Department of Chemistry, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
16
|
Kong FZ, Yang Y, He YC, Zhang Q, Li GQ, Fan LY, Xiao H, Li S, Cao CX. Design of suitable carrier buffer for free-flow zone electrophoresis by charge-to-mass ratio and band broadening analysis. Electrophoresis 2016; 37:2393-400. [DOI: 10.1002/elps.201600040] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2016] [Revised: 06/05/2016] [Accepted: 06/14/2016] [Indexed: 11/12/2022]
Affiliation(s)
- Fan-zhi Kong
- Laboratory of Analytical Biochemistry and Bio-separation, State Key Laboratory of Microbial Metabolism, School of Life Science and Biotechnology; Shanghai Jiao Tong University; Shanghai P. R. China
| | - Ying Yang
- Laboratory of Analytical Biochemistry and Bio-separation, State Key Laboratory of Microbial Metabolism, School of Life Science and Biotechnology; Shanghai Jiao Tong University; Shanghai P. R. China
- School of Bioscience and Bioengineering; South China University of Technology; Guangzhou P. R. China
| | - Yu-chen He
- Laboratory of Analytical Biochemistry and Bio-separation, State Key Laboratory of Microbial Metabolism, School of Life Science and Biotechnology; Shanghai Jiao Tong University; Shanghai P. R. China
| | - Qiang Zhang
- Laboratory of Analytical Biochemistry and Bio-separation, State Key Laboratory of Microbial Metabolism, School of Life Science and Biotechnology; Shanghai Jiao Tong University; Shanghai P. R. China
| | - Guo-qing Li
- Laboratory of Analytical Biochemistry and Bio-separation, State Key Laboratory of Microbial Metabolism, School of Life Science and Biotechnology; Shanghai Jiao Tong University; Shanghai P. R. China
| | - Liu-yin Fan
- Laboratory of Analytical Biochemistry and Bio-separation, State Key Laboratory of Microbial Metabolism, School of Life Science and Biotechnology; Shanghai Jiao Tong University; Shanghai P. R. China
| | - Hua Xiao
- Laboratory of Analytical Biochemistry and Bio-separation, State Key Laboratory of Microbial Metabolism, School of Life Science and Biotechnology; Shanghai Jiao Tong University; Shanghai P. R. China
| | - Shan Li
- School of Bioscience and Bioengineering; South China University of Technology; Guangzhou P. R. China
| | - Cheng-xi Cao
- Laboratory of Analytical Biochemistry and Bio-separation, State Key Laboratory of Microbial Metabolism, School of Life Science and Biotechnology; Shanghai Jiao Tong University; Shanghai P. R. China
| |
Collapse
|
17
|
Hao F, Li J, Zhai R, Jiao F, Zhang Y, Qian X. A novel microscale preparative gel electrophoresis system. Analyst 2016; 141:4953-60. [DOI: 10.1039/c6an00780e] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
A novel microscale preparative gel electrophoresis system is designed and manufactured for protein separation and preparation.
Collapse
Affiliation(s)
- Feiran Hao
- State Key Laboratory of Proteomics
- National Center for Protein Science
- Beijing Institute of Radiation Medicine
- Beijing 102206
- China
| | - Jiabin Li
- State Key Laboratory of Proteomics
- National Center for Protein Science
- Beijing Institute of Radiation Medicine
- Beijing 102206
- China
| | - Rui Zhai
- State Key Laboratory of Proteomics
- National Center for Protein Science
- Beijing Institute of Radiation Medicine
- Beijing 102206
- China
| | - Fenglong Jiao
- State Key Laboratory of Proteomics
- National Center for Protein Science
- Beijing Institute of Radiation Medicine
- Beijing 102206
- China
| | - Yangjun Zhang
- State Key Laboratory of Proteomics
- National Center for Protein Science
- Beijing Institute of Radiation Medicine
- Beijing 102206
- China
| | - Xiaohong Qian
- State Key Laboratory of Proteomics
- National Center for Protein Science
- Beijing Institute of Radiation Medicine
- Beijing 102206
- China
| |
Collapse
|