1
|
Li P, Wu DR, Yip SH, Sun D, Pawluczyk J, Smith A, Kempson J, Mathur A. Large-scale purification of a deprotected macrocyclic peptide by supercritical fluid chromatography (SFC) integrated with liquid chromatography in discovery chemistry. J Chromatogr A 2024; 1730:465112. [PMID: 38972253 DOI: 10.1016/j.chroma.2024.465112] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2024] [Revised: 06/18/2024] [Accepted: 06/20/2024] [Indexed: 07/09/2024]
Abstract
A macrocyclic peptide A was successfully purified in large quantities (∼30 g) in >95 % purity by an integrated two-step orthogonal purification process combining supercritical fluid chromatography (SFC) with medium-pressure reverse-phase liquid chromatography (MP-RPLC). MP-RPLC was used to fractionate the crude peptide A, remove unwanted trifluoroacetic acid (TFA) originating from the peptide A cleavage off the resin, and convert the peptide A into ammonium acetate salt form, prior to the final purification by SFC. A co-solvent of methanol/acetonitrile containing ammonium acetate and water in CO2 was developed on a Waters BEH 2-Ethylpyridine column. The developed SFC method was readily scaled up onto a 5 cm diameter column to process multi-gram quantities of the MP-RPLC fraction to reach > 95 % purity with a throughput/productivity of 0.96 g/h. The incorporation of SFC with MP-RPLC has been demonstrated to have a broader application in other large-scale polypeptide purifications.
Collapse
Affiliation(s)
- Peng Li
- Department of Discovery Synthesis, Research and Development, Bristol-Myers Squibb, Route 206 & Province Line Rd, Princeton, NJ 08543-4000, USA
| | - Dauh-Rurng Wu
- Department of Discovery Synthesis, Research and Development, Bristol-Myers Squibb, Route 206 & Province Line Rd, Princeton, NJ 08543-4000, USA
| | - Shiuhang Henry Yip
- Department of Discovery Synthesis, Research and Development, Bristol-Myers Squibb, Route 206 & Province Line Rd, Princeton, NJ 08543-4000, USA.
| | - Dawn Sun
- Department of Discovery Synthesis, Research and Development, Bristol-Myers Squibb, Route 206 & Province Line Rd, Princeton, NJ 08543-4000, USA
| | - Joseph Pawluczyk
- Department of Discovery Synthesis, Research and Development, Bristol-Myers Squibb, Route 206 & Province Line Rd, Princeton, NJ 08543-4000, USA
| | - Aaron Smith
- Spectrix, Route 206 & Province Line Rd, Princeton, NJ 08543-4000, USA
| | - James Kempson
- Department of Discovery Synthesis, Research and Development, Bristol-Myers Squibb, Route 206 & Province Line Rd, Princeton, NJ 08543-4000, USA
| | - Arvind Mathur
- Department of Discovery Synthesis, Research and Development, Bristol-Myers Squibb, Route 206 & Province Line Rd, Princeton, NJ 08543-4000, USA
| |
Collapse
|
2
|
West C. Supercritical fluid chromatography is not (only) normal-phase chromatography. J Chromatogr A 2024; 1713:464546. [PMID: 38041976 DOI: 10.1016/j.chroma.2023.464546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 11/26/2023] [Accepted: 11/27/2023] [Indexed: 12/04/2023]
Abstract
Supercritical fluid chromatography (SFC), now using carbon dioxide as a major component of the mobile phase, has been known for over 60 years but still some misunderstandings remain about its capabilities. Amongst them, SFC is often described as a normal-phase chromatographic technique, based on different considerations: polarity of the stationary phase, elution order of the analytes, relative non-polarity of the mobile phase, non-linear retention behaviour, or adsorption retention mechanisms. All of these assumptions are true to a certain extent, and in certain circumstances. But also, all of these assumptions are wrong in different circumstances. In this paper, the criteria to categorize SFC as a normal-phase chromatographic method will be examined individually, considering all knowledge acquired from the early years of its development. Finally, it will appear that the "normal-phase" glass lens is greatly reducing the true extent of SFC's possibilities.
Collapse
Affiliation(s)
- Caroline West
- Institute of Organic and Analytical Chemistry, University of Orleans, CNRS UMR7311, rue de Chartres - BP 6759, Orléans 45067, France.
| |
Collapse
|
3
|
Yue L, Miller L, Reilly J. Analytical and preparative chiral supercritical fluid chromatography resolutions using crown ether-derived column. Chirality 2024; 36:e23621. [PMID: 37737018 DOI: 10.1002/chir.23621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Revised: 09/04/2023] [Accepted: 09/07/2023] [Indexed: 09/23/2023]
Abstract
In this study, crown ether-derived column Crownpak® CR-I (+) was evaluated under SFC conditions using 12 primary amines, and the chromatographic results were compared against eight immobilized polysaccharide-based columns. Crownpak® CR-I (+) achieved a significantly higher success rate. It was found that the addition of 5% water to the modifier dramatically improved the peak shape for chiral separation of primary amines on Crownpak® CR-I (+). The first reported preparative SFC separations on Crownpak® CR-I (+) are shown, offering a new approach for the preparative resolution of primary amines. The case studies demonstrate that Crownpak® CR-I (+) is a very useful column in the chiral separation of challenging compounds that contain a primary amine group in the pharmaceutical industry.
Collapse
Affiliation(s)
- Lei Yue
- Novartis Institutes for BioMedical Research, Cambridge, Massachusetts, USA
| | | | - John Reilly
- Novartis Institutes for BioMedical Research, Basel, Switzerland
| |
Collapse
|
4
|
Molineau J, Hideux M, Hennig P, Bertin S, Mauge F, Lesellier E, West C. Effect of dilution solvent and injection volume on the analysis of basic hydrophilic therapeutic polypeptide salts with pressurized carbon dioxide mobile phases. J Chromatogr B Analyt Technol Biomed Life Sci 2022; 1213:123519. [DOI: 10.1016/j.jchromb.2022.123519] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 10/29/2022] [Accepted: 11/01/2022] [Indexed: 11/07/2022]
|
5
|
Fornstedt T, Enmark M, Samuelsson J. Method transfer in SFC from a fundamental perspective. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116551] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
6
|
Effect of water addition to super/sub-critical fluid mobile-phases for achiral and chiral separations. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116464] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
7
|
Burlet-Parendel M, Faure K. Opportunities and challenges of liquid chromatography coupled to supercritical fluid chromatography. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116422] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
8
|
Glenne E, Leśko M, Samuelsson J, Fornstedt T. Impact of Methanol Adsorption on the Robustness of Analytical Supercritical Fluid Chromatography in Transfer from SFC to UHPSFC. Anal Chem 2020; 92:15429-15436. [PMID: 33170667 PMCID: PMC7711781 DOI: 10.1021/acs.analchem.0c03106] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Abstract
![]()
In supercritical fluid chromatography
(SFC), the retention of a
solute depends on the temperature, density, pressure, and cosolvent
fraction. Here, we investigate how the adsorption of the cosolvent
MeOH changes with pressure and temperature and how this affects the
retention of several solutes. The lower the pressure, the stronger
the MeOH adsorption to the stationary phase; in addition, at low pressure,
perturbing the pressure results in significant changes in the amounts
of MeOH adsorbed to the stationary phase. The robustness of the solute
retention was lowest when operating the systems at low pressures,
high temperatures, and low cosolvent fractions in the eluent. Here,
we found a clear relationship between the sensitivity of MeOH adsorption
to the stationary phase and the robustness of the separation system.
Finally, we show that going from classical SFC to ultrahigh-performance
SFC (UHPSFC), that is, separations conducted with much smaller packing
diameters, results in retention factors that are more sensitive to
fluctuations in the flow rate than with traditional SFC. The calculated
density profiles indicate only a slight density drop over the traditional
SFC column (3%, visualized as lighter → darker blue in the
TOC), whereas the drop for the UHPSFC one was considerably larger
(20%, visualized as dark red → light green in the TOC). The
corresponding temperature drops were calculated to be 0.8 and 6.5
°C for the SFC and UHPSFC systems, respectively. These increased
density and temperature drops are the underlying reasons for the decreased
robustness of UHPSFC.
Collapse
Affiliation(s)
- Emelie Glenne
- Department of Engineering and Chemical Sciences, Karlstad University, SE-651 88 Karlstad, Sweden
| | - Marek Leśko
- Department of Engineering and Chemical Sciences, Karlstad University, SE-651 88 Karlstad, Sweden
| | - Jörgen Samuelsson
- Department of Engineering and Chemical Sciences, Karlstad University, SE-651 88 Karlstad, Sweden
| | - Torgny Fornstedt
- Department of Engineering and Chemical Sciences, Karlstad University, SE-651 88 Karlstad, Sweden
| |
Collapse
|
9
|
Enhancing supercritical fluid chromatographic efficiency: Predicting effects of small aqueous additives. Anal Chim Acta 2020; 1120:75-84. [DOI: 10.1016/j.aca.2020.04.065] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 04/21/2020] [Accepted: 04/26/2020] [Indexed: 11/19/2022]
|
10
|
Glenne E, Samuelsson J, Leek H, Forssén P, Klarqvist M, Fornstedt T. Systematic investigations of peak distortions due to additives in supercritical fluid chromatography. J Chromatogr A 2020; 1621:461048. [DOI: 10.1016/j.chroma.2020.461048] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2020] [Revised: 03/12/2020] [Accepted: 03/14/2020] [Indexed: 11/28/2022]
|
11
|
Unravelling the effects of mobile phase additives in supercritical fluid chromatography—Part II: Adsorption on the stationary phase. J Chromatogr A 2019; 1593:135-146. [DOI: 10.1016/j.chroma.2019.02.002] [Citation(s) in RCA: 42] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Revised: 01/29/2019] [Accepted: 02/01/2019] [Indexed: 01/02/2023]
|
12
|
Current trends in supercritical fluid chromatography. Anal Bioanal Chem 2018; 410:6441-6457. [DOI: 10.1007/s00216-018-1267-4] [Citation(s) in RCA: 90] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Revised: 06/18/2018] [Accepted: 07/12/2018] [Indexed: 12/16/2022]
|
13
|
Investigation of robustness for supercritical fluid chromatography separation of peptides: Isocratic vs gradient mode. J Chromatogr A 2018; 1568:177-187. [PMID: 30072233 DOI: 10.1016/j.chroma.2018.07.029] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2018] [Revised: 07/01/2018] [Accepted: 07/05/2018] [Indexed: 11/22/2022]
Abstract
We investigated and compared the robustness of supercritical fluid chromatography (SFC) separations of the peptide gramicidin, using either isocratic or gradient elution. This was done using design of experiments in a design space of co-solvent fraction, water mass fraction in co-solvent, pressure, and temperature. The density of the eluent (CO2-MeOH-H2O) was experimentally determined using a Coriolis mass flow meter to calculate the volumetric flow rate required by the design. For both retention models, the most important factor was the total co-solvent fraction and water mass fraction in co-solvent. Comparing the elution modes, we found that gradient elution was more than three times more robust than isocratic elution. We also observed a relationship between the sensitivity to changes and the gradient steepness and used this to draw general conclusions beyond the studied experimental system. To test the robustness in a practical context, both the isocratic and gradient separations were transferred to another laboratory. The gradient elution was highly reproducible between laboratories, whereas the isocratic system was not. Using measurements of the actual operational conditions (not the set system conditions), the isocratic deviation was quantitatively explained using the retention model. The findings indicate the benefits of using gradient elution in SFC as well as the importance of measuring the actual operational conditions to be able to explain observed differences between laboratories when conducting method transfer.
Collapse
|
14
|
Kim HS, Choi G, Lee AY. Ultra-performance convergence chromatography method for the determination of four chromones and quality control ofSaposhnikovia divaricata(Turcz.) Schischk. J Sep Sci 2018; 41:1682-1690. [DOI: 10.1002/jssc.201701281] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2017] [Revised: 12/12/2017] [Accepted: 12/13/2017] [Indexed: 12/11/2022]
Affiliation(s)
- Hyo Seon Kim
- K-Herb Research Center; Korea Institute of Oriental Medicine; Daejeon Republic of Korea
| | - Goya Choi
- K-Herb Research Center; Korea Institute of Oriental Medicine; Daejeon Republic of Korea
| | - A. Yeong Lee
- K-Herb Research Center; Korea Institute of Oriental Medicine; Daejeon Republic of Korea
| |
Collapse
|
15
|
Desfontaine V, Tarafder A, Hill J, Fairchild J, Grand-Guillaume Perrenoud A, Veuthey JL, Guillarme D. A systematic investigation of sample diluents in modern supercritical fluid chromatography. J Chromatogr A 2017; 1511:122-131. [PMID: 28689578 DOI: 10.1016/j.chroma.2017.06.075] [Citation(s) in RCA: 59] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Revised: 06/30/2017] [Accepted: 06/30/2017] [Indexed: 12/26/2022]
Abstract
This paper focuses on the possibility to inject large volumes (up to 10μL) in ultra-high performance supercritical fluid chromatography (UHPSFC) under generic gradient conditions. Several injection and method parameters have been individually evaluated (i.e. analyte concentration, injection volume, initial percentage of co-solvent in the gradient, nature of the weak needle wash solvent, nature of the sample diluent, nature of the column and of the analyte). The most critical parameters were further investigated using in a multivariate approach. The overall results suggested that several aprotic solvents including methyl tert-butyl ether (MTBE), dichloromethane, acetonitrile or cyclopentyl methyl ether (CPME) were well adapted for the injection of large volume in UHPSFC, while MeOH was generally the worst alternative. However, the nature of the stationary phase also had a strong impact and some of these diluents did not perform equally on each column. This was due to the existence of a competition in the adsorption of the analyte and the diluent on the stationary phase. This observation introduced the idea that the sample diluent should not only be chosen according to the analyte but also to the column chemistry to limit the interactions between the diluent and the ligands. Other important characteristics of the "ideal" SFC sample diluent were finally highlighted. Aprotic solvents with low viscosity are preferable to avoid strong solvent effects and viscous fingering, respectively. In the end, the authors suggest that the choice of the sample diluent should be part of the method development, as a function of the analyte and the selected stationary phase.
Collapse
Affiliation(s)
- Vincent Desfontaine
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | | | - Jason Hill
- Waters Corporation, 34 Maple Street, Milford 01757, USA
| | | | | | - Jean-Luc Veuthey
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland.
| |
Collapse
|
16
|
Systematic investigations of peak deformations due to co-solvent adsorption in preparative supercritical fluid chromatography. J Chromatogr A 2017; 1496:141-149. [DOI: 10.1016/j.chroma.2017.03.053] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2016] [Revised: 03/17/2017] [Accepted: 03/20/2017] [Indexed: 11/24/2022]
|
17
|
Rajendran A. Local equilibrium theory analysis of chromatographic peak shapes in the presence of adsorbing modifiers. J Chromatogr A 2017; 1485:52-61. [DOI: 10.1016/j.chroma.2017.01.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2016] [Revised: 12/19/2016] [Accepted: 01/03/2017] [Indexed: 10/20/2022]
|
18
|
A case of Z/E-isomers elution order inversion caused by cosolvent percentage change in supercritical fluid chromatography. J Chromatogr A 2017; 1479:177-184. [DOI: 10.1016/j.chroma.2016.11.037] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2016] [Revised: 11/11/2016] [Accepted: 11/20/2016] [Indexed: 11/19/2022]
|