1
|
Supercritical fluid chromatography coupled to high-resolution tandem mass spectrometry: an innovative one-run method for the comprehensive assessment of chocolate quality and authenticity. Anal Bioanal Chem 2022; 414:6825-6840. [PMID: 35970969 DOI: 10.1007/s00216-022-04246-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 07/06/2022] [Accepted: 07/21/2022] [Indexed: 11/01/2022]
Abstract
To assess chocolate quality and authenticity comprehensively, a combination of various analytical procedures is involved, thereby making the process time-consuming and costly. Thus, we investigated the potential of ultra-high performance supercritical fluid chromatography coupled to quadrupole-time of flight mass spectrometry (UHPSFC-QTOF-MS) as an alternative to "classic" methods. By combining hexane and aqueous extracts from sequential extraction, a single 8-min analytical run enabled us (i) to determine cocoa butter equivalents (CBEs) and milk fat content based on the detection of selected triacylglycerols, (ii) to calculate dry non-fat cocoa solids based on determined theobromine and caffeine content, and (iii) to profile contained sugars. To obtain the most comprehensive information about sample composition, the MS method comprised a full MS scan for non-target screening and several time-scheduled targeted MS/MS functions ("parallel reaction monitoring") optimized according to the possible concentration ranges of the analytes. For 40 different chocolate samples, our results and those obtained by using standard methods (LC-UV for non-fat cocoa solids, and GC-FID for CBEs) were in good agreement. Compared to the conventional approach for chocolate quality and authenticity control, the presented SFC-MS method is a fast, cost-effective, and efficient alternative, and only samples suspicious for the presence of CBE should be referred to the standard GC-FID method for exact CBE quantification. In the study, also some challenges offered by SFC-MS have been addressed.
Collapse
|
2
|
Khater S, Ferguson P, Grand-Guillaume-Perrenoud A. Method development approaches for small-molecule analytes. SEP SCI TECHNOL 2022. [DOI: 10.1016/b978-0-323-88487-7.00005-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
|
4
|
Jambo H, Dispas A, Hubert C, Lecomte F, Ziemons É, Hubert P. Generic SFC-MS methodology for the quality control of vitamin D 3 oily formulations. J Pharm Biomed Anal 2021; 209:114492. [PMID: 34864591 DOI: 10.1016/j.jpba.2021.114492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 11/19/2021] [Accepted: 11/20/2021] [Indexed: 11/18/2022]
Abstract
Vitamin D3 is a key micronutrient whose intakes are inadequate for most populations worldwide. Supplementation with medicines or food supplements is commonly prescribed to correct this imbalance and the quality of these products must be ensured. In this context, a generic methodology for the assay of vitamin D3 in oily formulations is proposed using supercritical fluid chromatography coupled to mass spectrometry (SFC-MS). It is in line with green analytical chemistry principles and combines the use of i) a fast and robust analytical method (4.0 min analysis time) ii) an easy sample preparation compatible with high throughput analysis ("dilute-and-shoot" approach) and iii) a relevant control strategy. Seventeen products from multiple manufacturers and encompassing a large content range were evaluated in this study. They were classified in four groups to streamline their processing considering the use of a matrix-matched calibration procedure. Matrix effect was thoroughly studied and was found to be low (99-106%), stable intra/inter-series and comparable between the different groups and types of matrices. The implemented control strategy was based on a three-level system suitability tests (SST). Level 1 SST: resolution of the critical pair that was above 1.5 for all analysis series. Level 2 SST: evaluation of the adequacy of the calibration for a QC sample in terms of recovery that was between 97% and 104% with a variability between 1% and 2%. Level 3 SST: method trueness that was between 95% and 102%. Sample analysis highlighted differences in types of products and dosage forms. This is the first study to propose a complete strategy for the quality control of vitamin D3 oily formulations and should prove useful in QC laboratories.
Collapse
Affiliation(s)
- Hugues Jambo
- University of Liège (ULiège), CIRM, Laboratory of Pharmaceutical Analytical Chemistry, Liège, Belgium.
| | - Amandine Dispas
- University of Liège (ULiège), CIRM, Laboratory of Pharmaceutical Analytical Chemistry, Liège, Belgium; University of Liège (ULiège), CIRM, Laboratory for the Analysis of Medicines, Liège, Belgium
| | - Cédric Hubert
- University of Liège (ULiège), CIRM, Laboratory of Pharmaceutical Analytical Chemistry, Liège, Belgium
| | - Frédéric Lecomte
- University of Liège (ULiège), CIRM, Department of Pharmaceutical Sciences, Liège, Belgium
| | - Éric Ziemons
- University of Liège (ULiège), CIRM, Laboratory of Pharmaceutical Analytical Chemistry, Liège, Belgium
| | - Philippe Hubert
- University of Liège (ULiège), CIRM, Laboratory of Pharmaceutical Analytical Chemistry, Liège, Belgium
| |
Collapse
|
5
|
Feng L, Wu L, Guo Y, Hamada N, Hashi Y, Li X, Cao L. Determination of vitamin D3 in daily oily supplements by a two-dimensional supercritical fluid chromatography-liquid chromatography-mass spectrometry system. J Chromatogr A 2020; 1629:461510. [DOI: 10.1016/j.chroma.2020.461510] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2020] [Revised: 08/07/2020] [Accepted: 08/24/2020] [Indexed: 01/08/2023]
|
7
|
Hamada N, Guo Y, Ji F, Zhang L, Yamaki S, Li H, Li Y, Hashi Y, Lin JM. Determination of vitamin D in oily drops using a column-switching system with an on-line clean-up by supercritical fluid chromatography. Talanta 2018; 190:9-14. [DOI: 10.1016/j.talanta.2018.07.063] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2018] [Revised: 07/17/2018] [Accepted: 07/19/2018] [Indexed: 12/19/2022]
|
8
|
Jambo H, Dispas A, Avohou HT, André S, Hubert C, Lebrun P, Ziemons É, Hubert P. Implementation of a generic SFC-MS method for the quality control of potentially counterfeited medicinal cannabis with synthetic cannabinoids. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1092:332-342. [DOI: 10.1016/j.jchromb.2018.05.049] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2018] [Revised: 05/25/2018] [Accepted: 05/29/2018] [Indexed: 11/29/2022]
|
9
|
Oberson JM, Campos-Giménez E, Rivière J, Martin F. Application of supercritical fluid chromatography coupled to mass spectrometry to the determination of fat-soluble vitamins in selected food products. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1086:118-129. [DOI: 10.1016/j.jchromb.2018.04.017] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Revised: 04/06/2018] [Accepted: 04/07/2018] [Indexed: 11/30/2022]
|
10
|
Desfontaine V, Losacco GL, Gagnebin Y, Pezzatti J, Farrell WP, González-Ruiz V, Rudaz S, Veuthey JL, Guillarme D. Applicability of supercritical fluid chromatography - mass spectrometry to metabolomics. I - Optimization of separation conditions for the simultaneous analysis of hydrophilic and lipophilic substances. J Chromatogr A 2018; 1562:96-107. [PMID: 29861304 DOI: 10.1016/j.chroma.2018.05.055] [Citation(s) in RCA: 65] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Revised: 05/20/2018] [Accepted: 05/26/2018] [Indexed: 12/13/2022]
Abstract
The aim of this study was to evaluate the suitability of SFC-MS for the analysis of a wide range of compounds including lipophilic and highly hydrophilic substances (log P values comprised between -6 and 11), for its potential application toward human metabolomics. For this purpose, a generic unified chromatography gradient from 2 to 100% organic modifier in CO2 was systematically applied. In terms of chemistry, the best stationary phases for this application were found to be the Agilent Poroshell HILIC (bare silica) and Macherey-Nagel Nucleoshell HILIC (silica bonded with a zwitterionic ligand). To avoid system overpressure at very high organic modifier proportion, columns of 100 × 3 mm I.D. packed with sub-3 μm superficially porous particles were selected. In terms of organic modifier, a mixture of 95% MeOH and 5% water was selected, with 50 mM ammonium formate and 1 mM ammonium fluoride, to afford good solubility of analytes in the mobile phase, limited retention for the most hydrophilic metabolites and suitable peak shapes of ionizable species. A sample diluent containing 50%ACN/50% water was employed as injection solvent. These conditions were applied to a representative set of metabolites belonging to nucleosides, nucleotides, small organic acids, small bases, sulfated/sulfonated metabolites, poly-alcohols, lipid related substances, quaternary ammonium metabolites, phosphate-based substances, carbohydrates and amino acids. Among all these metabolites, 65% of the compounds were adequately analyzed with excellent peak shape, 23% provided distorted peak shapes, while only 12% were not detected (mostly metabolites having several phosphate or several carboxylic acid groups).
Collapse
Affiliation(s)
- Vincent Desfontaine
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Gioacchino Luca Losacco
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Yoric Gagnebin
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Julian Pezzatti
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - William P Farrell
- Pfizer, Inc., Worldwide Medicinal Chemistry, La Jolla Laboratories, 10770 Science Center Drive, San Diego, CA 92121, USA
| | - Víctor González-Ruiz
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Serge Rudaz
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Jean-Luc Veuthey
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland.
| |
Collapse
|