1
|
Lai H, Li G. Recent progress on media for biological sample preparation. J Chromatogr A 2024; 1734:465293. [PMID: 39181092 DOI: 10.1016/j.chroma.2024.465293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2024] [Revised: 08/19/2024] [Accepted: 08/20/2024] [Indexed: 08/27/2024]
Abstract
The analysis of biological samples is highly valuable for disease diagnosis and treatment, forensic examination, and public safety. However, the serious matrix interference effect generated by biological samples severely affects the analysis of trace analytes. Sample preparation methods are introduced to address the limitation by extracting, separating, enriching, purifying trace target analytes from biological samples. With the raising demand of biological sample analysis, a review focuses on media for biological sample preparation and analysis over the last 5 years is presented. High-performance media in biological sample preparation are first reviewed, including porous organic frameworks, imprinted polymers, hydrogels, ionic liquids, and bioactive media. Then, application of media for different biological sample preparation and analysis is briefly introduced, including liquid samples of body fluids, solid samples (hair, feces, and tissues), and gas samples of exhale breath gas. Finally, conclusions and outlooks on media promoting biological sample preparation are presented.
Collapse
Affiliation(s)
- Huasheng Lai
- Jiangxi Province Key Laboratory of Pharmacology of Traditional Chinese Medicine, School of Pharmacy, Gannan Medical University, Ganzhou, 341000, China; School of chemistry, Sun Yat-Sen University, Guangzhou, 510006, China.
| | - Gongke Li
- School of chemistry, Sun Yat-Sen University, Guangzhou, 510006, China.
| |
Collapse
|
2
|
Song C, Dowlatshah S, Gaznawi S, Hay AO, Hasvold G, Hansen FA. New robust and efficient liquid membranes for conductive vial electromembrane extraction of acids with low to moderate hydrophilicity in human plasma. Anal Bioanal Chem 2024:10.1007/s00216-024-05503-6. [PMID: 39207493 DOI: 10.1007/s00216-024-05503-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2024] [Revised: 08/06/2024] [Accepted: 08/15/2024] [Indexed: 09/04/2024]
Abstract
The current paper reports two new, robust, and efficient conditions for electromembrane extraction of acidic substances from human plasma. Two systems were developed based on eutectic solvents: A1 ("A" for acid) comprised dodecyl methyl sulfoxide and thymol in 1:2 ratio (w/w) as liquid membrane, while A2 used [6-methylcoumarin:thymol (1:2)]:2-nitrophenyl octyl ether in 2:1 ratio (w/w). The performance of A1 and A2 was characterized by extraction of 31 acidic model analytes (pharmaceutical drugs and nutrients) spiked into 100 µL human plasma diluted 1:1 (v/v) with phosphate buffer pH 7.4. The acceptor solution was 50 mM NH4HCO3 buffer pH 10.0, and extraction was performed at an agitation rate of 750 RPM. Voltage and extraction time were 30 V for 30 min and 10 V for 20 min for A1 and A2, respectively. Under optimal conditions, A1 extracted analytes with 1.8 ≤ log P ≤ 6.0 with an average recovery (R) of 85.1%, while A2 extracted in a range of 0.5 ≤ log P ≤ 6.0 with an average recovery of 79.9%. Meanwhile, extraction current was low at 9 and 26 µA, respectively, which is indicative of good system robustness. Using UHPLC-MS/MS analysis of the acceptor solution, repeatability of the A1 and A2 methods was determined to be 2.8-7.7% and 3.3-9.4% for R > 40%, matrix effects were 82-117% and 84-112%, respectively, and linear calibration curves were obtained. The performance and compatibility with human plasma represent a major improvement over previous state-of-the-art liquid membranes for acidic analytes, namely 1-octanol.
Collapse
Affiliation(s)
- Chenchen Song
- Department of Pharmacy, University of Oslo, Blindern, P.O. Box 1068, 0316, Oslo, Norway
- School of Chemistry and Chemical Engineering, Henan University of Technology, Zhengzhou, 450001, China
| | - Samira Dowlatshah
- Department of Pharmacy, University of Oslo, Blindern, P.O. Box 1068, 0316, Oslo, Norway
| | - Somayeh Gaznawi
- Department of Pharmacy, University of Oslo, Blindern, P.O. Box 1068, 0316, Oslo, Norway
| | - Anne Oldeide Hay
- Department of Pharmacy, University of Oslo, Blindern, P.O. Box 1068, 0316, Oslo, Norway
| | - Grete Hasvold
- Department of Pharmacy, University of Oslo, Blindern, P.O. Box 1068, 0316, Oslo, Norway
| | - Frederik André Hansen
- Department of Pharmacy, University of Oslo, Blindern, P.O. Box 1068, 0316, Oslo, Norway.
| |
Collapse
|
3
|
Xiong J, Tian L, Shen X, Huang C. Comparison of the applicability of electromembrane extraction and liquid-phase microextraction for extraction of non-polar basic drugs from different biological samples: Using clozapine as the model analyte. J Sep Sci 2024; 47:e2300745. [PMID: 38356226 DOI: 10.1002/jssc.202300745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Revised: 01/10/2024] [Accepted: 01/24/2024] [Indexed: 02/16/2024]
Abstract
Understanding and comparing the applicability of electromembrane extraction (EME) and liquid-phase microextraction (LPME) is crucial for selecting an appropriate microextraction approach. In this work, EME and LPME based on supported liquid membranes were compared using biological samples, including whole blood, urine, saliva, and liver tissue. After optimization, efficient EME and LPME of clozapine from four biological samples were achieved. EME provided higher recovery and faster mass transfer for blood and liver tissue than LPME. These advantages were attributed to the electric field disrupting clozapine binding to interfering substances. For urine and saliva, EME demonstrated similar recoveries while achieving faster mass transfer rates. Finally, efficient EME and LPME were validated and evaluated combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS). The coefficient of determination of all methods was greater than 0.999, and all methods showed acceptable reproducibility (≤14%), accuracy (90%-110%), and matrix effect (85%-112%). For liver and blood with high viscosity and complex matrices, EME-LC-MS/MS provided better sensitivity than LPME-LC-MS/MS. The above results indicated that both EME and LPME could be used to isolate non-polar basic drugs from different biological samples, although EME demonstrated higher recovery rates for liver tissue and blood.
Collapse
Affiliation(s)
- Jianhua Xiong
- Department of Forensic Medicine, Huazhong University of Science and Technology, Wuhan, China
| | - Linxin Tian
- Department of Forensic Medicine, Huazhong University of Science and Technology, Wuhan, China
| | - Xiantao Shen
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Huazhong University of Science and Technology, Wuhan, China
| | - Chuixiu Huang
- Department of Forensic Medicine, Huazhong University of Science and Technology, Wuhan, China
| |
Collapse
|
4
|
Schüller M, McQuade TAP, Bergh MSS, Pedersen-Bjergaard S, Øiestad EL. Determination of tryptamine analogs in whole blood by 96-well electromembrane extraction and UHPLC-MS/MS. TALANTA OPEN 2023. [DOI: 10.1016/j.talo.2022.100171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
|
5
|
Dong Y, Li J, Janiak C, Yang XY. Interfacial design for detection of a few molecules. Chem Soc Rev 2023; 52:779-794. [PMID: 36541179 DOI: 10.1039/d2cs00770c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Major advances in molecular detection are being driven by goals associated with the development of methods that are amenable to miniaturization and automation, and that have high sensitivity and low interference. The new detection methods are confronted by many interfacial issues, which when properly addressed can lead to improved performance. One interfacial property, special wettability, can facilitate precise delivery and local enrichment of molecules to sensing elements. This review summarizes applications of unique features of special wettability in molecular detection including (1) chemical and electrochemical reactions in anchored microdroplets on superwetting surfaces, (2) enrichment of analytes and active materials at low contact areas between droplets and superwetting surfaces, (3) complete opposite affinities of superwetting surfaces toward nonpolar/polar solutes and oil/water phases, and (4) directional droplet transportation on asymmetric superwetting surfaces. The challenges and opportunities that exist in design and applications of special wettability in interfacial delivery and enrichment for detection of a few molecules are also discussed.
Collapse
Affiliation(s)
- Ying Dong
- Department of Forensic Medicine, Tongji Medical College, Huazhong University of Science and Technology, 13 Hangkong Road, Wuhan 430030, China.,Shenzhen Huazhong University of Science and Technology Research Institute, 9 Yuexing Third Road, Nanshan District, Shenzhen 518000, China
| | - Jing Li
- Hubei Province Key Laboratory of Coal Conversion and New Carbon Materials, School of Chemistry and Chemical Engineering, Wuhan University of Science and Technology, 947 Peace Avenue, Wuhan 430081, China.
| | - Christoph Janiak
- Institut für Anorganische Chemie und Strukturchemie, Heinrich-Heine-Universität Düsseldorf, 40204 Düsseldorf, Germany
| | - Xiao-Yu Yang
- State Key Laboratory of Advanced Technology for Materials Synthesis and Processing & Shenzhen Research Institute & Joint Laboratory for Marine Advanced Materials in Pilot National Laboratory for Marine Science and Technology (Qingdao), Wuhan University of Technology, 122 Luoshi Road, Wuhan, 430070, China. .,School of Engineering and Applied Sciences, Harvard University, Cambridge, Massachusetts 02138, USA.
| |
Collapse
|
6
|
Wan L, Gao H, Liu X, Gao S, Zhou L, Wang F, Chen M. Electromembrane extraction of clenbuterol from swine urine for monitoring illegal use in livestock. J Sep Sci 2022; 45:3966-3973. [PMID: 36040857 DOI: 10.1002/jssc.202200469] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2022] [Revised: 08/20/2022] [Accepted: 08/24/2022] [Indexed: 11/10/2022]
Abstract
The illegal use of clenbuterol seriously endangers food safety and human health. Accurate monitoring the illegal use of clenbuterol in livestock can efficiently prevent the clenbuterol residue pork products from entering the consumer market. Thus, in this study, a simple, rapid and sensitive method for the determination of clenbuterol in swine urine was developed using electromembrane extraction combined with liquid chromatography-tandem mass spectrometry. It should be noted that the electromembrane extraction method presented many advantages of simple operation, fast mass transfer rate, good sample clean-up capability and less organic solvent consumption. The effect of important factors on the extraction efficiency of clenbuterol was investigated. Under the optimal conditions, good linearity was achieved for clenbuterol over the range of 1-1000 ng/mL (R2 = 0.9996). The recoveries of clenbuterol in swine urine at three spiked levels ranged from 83.7 to 110.0% with relative standard deviation values lower than 9.7% (n = 4). Limits of detection and quantification for clenbuterol were 0.07 and 0.25 ng/mL, respectively. These results suggested that the proposed method has great potential on the extraction and determination of trace analyte in complex sample matrix for monitoring the illegal use in livestock. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Libin Wan
- Institute of Business Scientific, Henan Academy of Sciences, Zhengzhou, PR China
| | - Haidong Gao
- Institute of Business Scientific, Henan Academy of Sciences, Zhengzhou, PR China
| | - Xiao Liu
- Institute of Business Scientific, Henan Academy of Sciences, Zhengzhou, PR China
| | - Shucai Gao
- Institute of Business Scientific, Henan Academy of Sciences, Zhengzhou, PR China
| | - Li Zhou
- Institute of Business Scientific, Henan Academy of Sciences, Zhengzhou, PR China
| | - Fayun Wang
- Institute of Business Scientific, Henan Academy of Sciences, Zhengzhou, PR China
| | - Mantang Chen
- Zhengzhou Tobacco Research Institute of CNTC, Zhengzhou, PR China
| |
Collapse
|
7
|
A simulation study of an applied approach to enhance drug recovery through electromembrane extraction. J Mol Liq 2022. [DOI: 10.1016/j.molliq.2022.119210] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
8
|
Santigosa E, Pedersen-Bjergaard S, Giménez-Gómez P, Muñoz M, Ramos-Payán M. A rapid and versatile microfluidic method for the simultaneous extraction of polar and non-polar basic pharmaceuticals from human urine. Anal Chim Acta 2022; 1208:339829. [DOI: 10.1016/j.aca.2022.339829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Revised: 04/05/2022] [Accepted: 04/09/2022] [Indexed: 11/01/2022]
|
9
|
Ingle RG, Zeng S, Jiang H, Fang WJ. Current development of bioanalytical sample preparation techniques in pharmaceuticals. J Pharm Anal 2022; 12:517-529. [PMID: 36105159 PMCID: PMC9463481 DOI: 10.1016/j.jpha.2022.03.001] [Citation(s) in RCA: 22] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 02/23/2022] [Accepted: 03/14/2022] [Indexed: 12/03/2022] Open
Abstract
Sample preparation is considered as the bottleneck step in bioanalysis because each biological matrix has its own unique challenges and complexity. Competent sample preparation to extract the desired analytes and remove redundant components is a crucial step in each bioanalytical approach. The matrix effect is a key hurdle in bioanalytical sample preparation, which has gained extensive consideration. Novel sample preparation techniques have advantages over classical techniques in terms of accuracy, automation, ease of sample preparation, storage, and shipment and have become increasingly popular over the past decade. Our objective is to provide a broad outline of current developments in various bioanalytical sample preparation techniques in chromatographic and spectroscopic examinations. In addition, how these techniques have gained considerable attention over the past decade in bioanalytical research is mentioned with preferred examples. Modern trends in bioanalytical sample preparation techniques, including sorbent-based microextraction techniques, are primarily emphasized. Bioanalytical sampling techniques are described with suitable applications in pharmaceuticals. The pros and cons of each bioanalytical sampling techniques are described. Relevant biological matrices are outlined.
Collapse
|
10
|
Eie LV, Pedersen-Bjergaard S, Hansen FA. Electromembrane extraction of polar substances - Status and perspectives. J Pharm Biomed Anal 2022; 207:114407. [PMID: 34634529 DOI: 10.1016/j.jpba.2021.114407] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 09/20/2021] [Accepted: 09/30/2021] [Indexed: 12/15/2022]
Abstract
In this article, the scientific literature on electromembrane extraction (EME) of polar substances (log P < 2) is reviewed. EME is an extraction technique based on electrokinetic migration of analyte ions from an aqueous sample, across an organic supported liquid membrane (SLM), and into an aqueous acceptor solution. Because extraction is based on voltage-assisted partitioning, EME is fundamentally suitable for extraction of polar and ionizable substances that are challenging in many other extraction techniques. The article provides an exhaustive overview of papers on EME of polar substances. From this, different strategies to improve the mass transfer of polar substances are reviewed and critically discussed. These strategies include different SLM chemistries, modification of supporting membranes, sorbent additives, aqueous solution chemistry, and voltage/current related strategies. Finally, the future applicability of EME for polar substances is discussed. We expect EME in the coming years to be developed towards both very selective targeted analysis, as well as untargeted analysis of polar substances in biomedical applications such as metabolomics and peptidomics.
Collapse
Affiliation(s)
- Linda Vårdal Eie
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway
| | - Stig Pedersen-Bjergaard
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway; Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark
| | - Frederik André Hansen
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway.
| |
Collapse
|
11
|
Shang Q, Mei H, Feng X, Huang C, Pedersen-Bjergaard S, Shen X. Ultrasound-assisted electromembrane extraction with supported semi-liquid membrane. Anal Chim Acta 2021; 1184:339038. [PMID: 34625271 DOI: 10.1016/j.aca.2021.339038] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Revised: 08/28/2021] [Accepted: 09/04/2021] [Indexed: 10/20/2022]
Abstract
Electromembrane extraction (EME), involving the migration of charged analytes across a supported liquid membrane (SLM) with an external power supply, is a promising sample preparation method in analytical chemistry. However, the presence of boundary double layers at the SLM/solution interfaces often restricts extraction efficiency. To avoid this, the current work proposed an ultrasound-assisted EME (UA-EME) method based on a novel type of supported semi-liquid membrane (SsLM). The characterizations showed that the SsLM was stable under ultrasound conditions. Ultrasound was found to reduce the boundary double layers and thus increase the mass transfer. Major operational parameters in UA-EME including ultrasound power density, temperature, applied voltage and extraction time were optimized with haloperidol, fluoxetine, and sertraline as model analytes. Under the optimal conditions, extraction recoveries of model analytes in water samples were in the range of 66.8%-91.6%. When this UA-EME method was coupled with LC-MS/MS for detection of the target analytes in human urine samples, the linear range of the analytical method was 10-1000 ng mL-1, with R2 > 0.997 for all analytes. The limits of detection (LOD) and limits of quantification (LOQ) were in the range of 1.7-2.1 ng mL-1 and 5.7-6.7 ng mL-1, respectively. The UA-EME expands the application field of ultrasound chemistry and will be very important in development of stable and fast sample preparation systems in the future.
Collapse
Affiliation(s)
- Qianqian Shang
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Hangkong Road #13, Wuhan, Hubei 430030, China
| | - Hang Mei
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Hangkong Road #13, Wuhan, Hubei 430030, China
| | - Xinrui Feng
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Hangkong Road #13, Wuhan, Hubei 430030, China
| | - Chuixiu Huang
- Department of Forensic Medicine, Huazhong University of Science and Technology, Hangkong Road #13, Wuhan, Hubei 430030, China.
| | - Stig Pedersen-Bjergaard
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway; Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, DK-2100 Copenhagen, Denmark
| | - Xiantao Shen
- State Key Laboratory of Environment Health (Incubation), Key Laboratory of Environment and Health, Ministry of Education, Key Laboratory of Environment and Health (Wuhan), Ministry of Environmental Protection, School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Hangkong Road #13, Wuhan, Hubei 430030, China.
| |
Collapse
|
12
|
Skaalvik TG, Øiestad EL, Trones R, Pedersen-Bjergaard S, Hegstad S. Determination of psychoactive drugs in serum using conductive vial electromembrane extraction combined with UHPLC-MS/MS. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1183:122926. [PMID: 34624684 DOI: 10.1016/j.jchromb.2021.122926] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 08/25/2021] [Accepted: 09/01/2021] [Indexed: 11/17/2022]
Abstract
Conductive vial electromembrane extraction (EME) with prototype equipment was applied for the first time to extract lipophilic basic drugs from serum. With this equipment, traditional platinum electrodes were replaced with sample and acceptor vials made from a conductive polymer, making the electrodes fully integrated and disposable. EME was combined with UHPLC-MS/MS, and a method to determine selected psychoactive drugs (alimemazine, amitriptyline, atomoxetine, clomipramine, doxepin, duloxetine, fluvoxamine, levomepromazine, nortriptyline and trimipramine) and metabolites (desmethyl clomipramine and desmethyl doxepin) in serum was developed, optimized, and validated. Extractions were carried out with 50 V for 15 min from serum samples (100 µL) diluted 1:3 with formic acid (0.1% v/v), using 2-nitrophenyl octyl ether as the supported liquid membrane (SLM), and formic acid (0.1% v/v, 300 µL) as acceptor phase. Using conductive vial EME, the extraction of lipophilic drugs reached exhaustive or near-exhaustive conditions, with recoveries in the range 75-117%. The method demonstrated excellent accuracy and precision, with bias within ± 6%, and intra- and inter-day CVs ranging 0.9 - 6% and 2 - 6%, respectively. In addition, acceptor phases were completely free of glycerophosphocholines. EME-UHPLC-MS/MS was successfully applied in determination of psychoactive drugs in 30 patient samples, and the results were in agreement with the current hospital routine method at St. Olav University Hospital (Trondheim, Norway). Obtaining comparable results to well-established routine methods is highly important for future implementation of EME into routine laboratories. These results thus serve as motivation for further advancing the EME technology. Until now, EME has been carried out with laboratory-build equipment, and the introduction of commercially available standardized equipment is expected to have a positive impact on future research activity.
Collapse
Affiliation(s)
- Tonje Gottenberg Skaalvik
- Department of Clinical Pharmacology, St. Olav University Hospital, Professor Brochs gate 6, 7030 Trondheim, Norway; Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway
| | - Elisabeth Leere Øiestad
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway; Department of Forensic Sciences, Division of Laboratory Medicine, Oslo University Hospital, P.O. Box 4950 Nydalen, 0424 Oslo, Norway
| | - Roger Trones
- Extraction Technologies Norway, Verkstedveien 29, 1424 Ski, Norway
| | - Stig Pedersen-Bjergaard
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway; Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark
| | - Solfrid Hegstad
- Department of Clinical Pharmacology, St. Olav University Hospital, Professor Brochs gate 6, 7030 Trondheim, Norway.
| |
Collapse
|
13
|
Kamankesh M, Mohammadi A, Ghanati K. Determination of biogenic amines in Lighvan cheese using a novel hollow‐fibre electromembrane‐microextraction coupled with gas chromatography–mass spectrometry. INT J DAIRY TECHNOL 2021. [DOI: 10.1111/1471-0307.12806] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Marzieh Kamankesh
- Cellular and Molecular Research Center Sabzevar University of Medical Sciences Assad Abadi street Sabzevar Iran
| | - Abdorreza Mohammadi
- Department of Food Science and Technology Faculty of Nutrition Science Food Science and Technology/National Nutrition and Food Technology Research Institute Shahid Beheshti University of Medical Sciences Arghavan street, Tehran Iran
- Food Safety Research Center Shahid Beheshti University of Medical Sciences Valiasre street Tehran Iran
| | - Kiandokht Ghanati
- Department of Food Science and Technology Faculty of Nutrition Science Food Science and Technology/National Nutrition and Food Technology Research Institute Shahid Beheshti University of Medical Sciences Arghavan street, Tehran Iran
- Food Safety Research Center Shahid Beheshti University of Medical Sciences Valiasre street Tehran Iran
| |
Collapse
|
14
|
Zhang X, Liu S, Wei X, Yu YL, Wang JH. A Novel Pretreatment Device Integrating Magnetic-Assisted Dispersive Extraction and Ultrasonic Spray Separation for Speciation Analysis of Arsenic in Whole Blood by Ion Chromatography-Inductively Coupled Plasma-Mass Spectrometry. Anal Chem 2021; 93:10577-10583. [PMID: 34283582 DOI: 10.1021/acs.analchem.1c01745] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Speciation analysis of arsenic in blood is essential for identifying and quantifying the exposure of arsenic and studying the metabolism and toxicity of arsenic. Herein, a novel pretreatment device is rationally designed and used for speciation analysis of arsenic in whole blood by ion chromatography-inductively coupled plasma-mass spectrometry (IC-ICP-MS). The sample centrifuge tubes containing blood, reagents, and a magnetic stir bar are placed on the fidget spinner of the pretreatment device. When flicking the fidget spinner rotation with the finger, the magnetic stir bar in the tube rotates in three dimensions under the magnetic field, thereby assisting dispersive extraction of arsenic species by the mixing of blood with reagents. Afterward, the arsenic extract is separated in situ from the blood matrix using an ultrasonic spray sheet covered with a filter and ultrafiltration membrane, which is directly used for subsequent IC-ICP-MS analysis. For 100 μL of blood, the whole pretreatment operation can be completed within 10 min. With As(III), As(V), MMA, and DMA in blood as analytes, the use of the present pretreatment device will hardly lead to the loss and transformation of arsenic species, and the extraction efficiency of the total arsenic is more than 96%. When the pretreatment device is coupled to IC-ICP-MS, the detection limits of four arsenic species in whole blood are 0.017-0.023 μg L-1, and precisions are within 2.3-4.2%. This pretreatment device provides a simple, fast, efficient, and low-cost tool for extraction and separation of arsenic species in whole blood, opening a new idea for the pretreatment of complex samples.
Collapse
Affiliation(s)
- Xiao Zhang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Shuang Liu
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Xing Wei
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Yong-Liang Yu
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| | - Jian-Hua Wang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China
| |
Collapse
|
15
|
Hansen FA, Tirandaz S, Pedersen-Bjergaard S. Selectivity and efficiency of electromembrane extraction of polar bases with different liquid membranes-Link to analyte properties. J Sep Sci 2021; 44:2631-2641. [PMID: 33909952 DOI: 10.1002/jssc.202100167] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 04/23/2021] [Accepted: 04/24/2021] [Indexed: 01/13/2023]
Abstract
In the present fundamental study, selectivity and efficiency of electromembrane extraction of 50 polar basic substances (-6.7 < log P < +1.0) was systematically studied for ten different supported liquid membranes. For each model substance, 23 molecular descriptors were collected and these were investigated as potential parameters for understanding of extraction efficiency and selectivity by means of partial least squares regression. Overall, a highly aromatic deep eutectic solvent composed of coumarin and thymol with addition of 2% ionic carrier (di(2-ethylhexyl) phosphate) provided the highest extraction efficiency with an average extraction yield of 69% from pure water samples, 55% from plasma, and 62% from urine. With this solvent system, ionic, cation-π, and π-π interactions between the supported liquid membrane and analytes were dominant. Supported liquid membranes without aromaticity, however, operated primarily based on hydrogen-bonding interactions. This is the first time the relationship between analyte properties, solvent composition, and extraction yield has systematically been studied for polar bases in electromembrane extraction. This new knowledge represents a first step toward enabling future development and optimization of electromembrane extraction systems for polar bases based on rational design, rather than trial-and-error approaches.
Collapse
Affiliation(s)
| | - Shima Tirandaz
- Department of Pharmacy, University of Oslo, Oslo, Norway
| | - Stig Pedersen-Bjergaard
- Department of Pharmacy, University of Oslo, Oslo, Norway.,Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|