Darvishnejad F, Raoof JB, Ghani M. In-situ synthesis of nanocubic cobalt oxide @ graphene oxide nanocomposite reinforced hollow fiber-solid phase microextraction for enrichment of non-steroidal anti-inflammatory drugs from human urine prior to their quantification via high-performance liquid chromatography-ultraviolet detection.
J Chromatogr A 2021;
1641:461984. [PMID:
33611121 DOI:
10.1016/j.chroma.2021.461984]
[Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2020] [Revised: 01/30/2021] [Accepted: 02/07/2021] [Indexed: 01/15/2023]
Abstract
The in-situ synthesis and application of nanocubic Co3O4-coated graphene oxide (Co3O4@ GO) was introduced for the first time to present a cost-effective, stable and convenient operation and a simple device for hollow fiber solid-phase microextraction (HF-SPME) of four selected nonsteroidal anti-inflammatory drugs (NSAIDs) including diclofenac, mefenamic acid, ibuprofen and indomethacin. The extracted analytes were desorbed by an appropriate organic solvent and analyzed via high-performance liquid chromatography-ultraviolet detection (HPLC-UV). The prepared sorbent was approved using different characterization methods such as X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FT-IR), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). The variables effective on the Co3O4@GO-HF-SPME method including extraction time, desorption time, desorption solvent volume, sample pH, stirring rate and ionic strength were screened via Plackett-Burman design and then optimized by Box-Behnken design. Under optimal condition, the calibration curves were linear within the range of 1.0-200.0 µg L-1 of analyte concentration with detection limits of 0.18-1.1 µg L-1 and the relative standard deviations less than 10.1%. The limits of quantification (LOQs) were in the range of 0.60-3.67 µg L-1. Matrix effect was not observed with this method; therefore, standard addition is not necessary for quantification of target compounds. The enrichment factors were obtained in the range of 49-68. The relative recoveries of the urine sample analysis were calculated in the range of 93-102%. Finally, the presented method exhibited good sensitivity, excellent repeatability, high reusability and acceptable precision, which will be a promising method to analyze various nonsteroidal anti-inflammatory drugs in urine samples.
Collapse