Yan K, Liu X, Liu J, He C, Li J, Bai Q. Octadecyl-fibrous mesoporous silica nanospheres coated 96-blade thin-film microextraction for high-throughput analysis of phthalic acid esters in food and migration from food packages. J Chromatogr A 2024; 1716:464636. [PMID: 38219624 DOI: 10.1016/j.chroma.2024.464636] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Revised: 12/19/2023] [Accepted: 01/07/2024] [Indexed: 01/16/2024]
Abstract
A high-throughput sample pre-treatment method combined with high-performance liquid chromatography (HPLC) was developed to analyze phthalates (PAEs) in food and food contact package samples. Thin film microextraction (TFME) in 96-blade format was used to pre-treat 96 samples simultaneously. Octadecyl groups functionalized fibrous mesoporous silica nanospheres, namely C18-FMSNs, were synthesized and used as TFME coating material. The coating was fabricated by spraying a slurry of C18-FMSNs and polyacrylontrile (PAN) mixture with a commercial portable spraypen. The prepared C18-FMSNs/PAN coatings exhibited good reproducibility, repeatability and reusability. The optimized TFME conditions for PAEs consisted of extraction at pH 4.0 for 50 min, and desorption by methanol/acetonitrile (25/75, V/V) for 40 min. The pretreatment time for each sample was approximately 1.3 min. This TFME-HPLC method showed good linearity for eight PAEs within the concentration range of 0.5-1000 ng mL-1, with the coefficients higher than 0.9972. The limits of detection and quantification were 0.096-0.26 ng mL-1 and 0.32-0.86 ng mL-1, respectively. The intra-day and inter-day RSD % were below 6.6 % and 8.4 %, respectively, indicating good precision. The PAEs analysis in real samples showed that dibutyl phthalate (DBP) of 2.3 ± 0.3 ng mL-1 and di-(2-ethylhexyl) phthalate (DEHP) of 5.5 ± 0.8 ng mL-1 in boxed milk, dimethyl phthalate (DMP) of 12.6 ± 0.8 ng mL-1, DBP of 3.2 ± 0.4 ng mL-1and DEHP of 14.3 ± 0.7 ng mL-1 in the simulated water migration of plastic box, as well as DMP of 19.0 ± 0.6 ng mL-1, DBP of 25.6 ± 0.9 ng mL-1 and DEHP of 49.5 ± 2.8 ng mL-1 in the simulated ethanol migration of plastic box were determined, respectively. In addition, the detection of PAEs in all the real samples showed good recovery ranging from 85.6 to 110 % and lower RSDs % (<7.2 %).
Collapse
Affiliation(s)
- Kaiqi Yan
- Key Laboratory of Synthetic and Natural Functional Molecule of the Ministry of Education, Modern Separation Science Key Laboratory of Shaanxi Province, College of Chemistry & Materials Science, Northwest University, Xi'an 710069, PR China
| | - Xiangwei Liu
- Key Laboratory of Synthetic and Natural Functional Molecule of the Ministry of Education, Modern Separation Science Key Laboratory of Shaanxi Province, College of Chemistry & Materials Science, Northwest University, Xi'an 710069, PR China
| | - Jiawei Liu
- Key Laboratory of Synthetic and Natural Functional Molecule of the Ministry of Education, Modern Separation Science Key Laboratory of Shaanxi Province, College of Chemistry & Materials Science, Northwest University, Xi'an 710069, PR China.
| | - Chong He
- Shaanxi Institute of Product Quality Supervision and Inspection, Xi'an 710048, PR China
| | - Jian Li
- Key Laboratory of Synthetic and Natural Functional Molecule of the Ministry of Education, Modern Separation Science Key Laboratory of Shaanxi Province, College of Chemistry & Materials Science, Northwest University, Xi'an 710069, PR China
| | - Quan Bai
- Key Laboratory of Synthetic and Natural Functional Molecule of the Ministry of Education, Modern Separation Science Key Laboratory of Shaanxi Province, College of Chemistry & Materials Science, Northwest University, Xi'an 710069, PR China.
| |
Collapse
|
2
|
Tao L, Tian Y, Liao D, An S, Chen W, Liu X, Xu P, Shen X, Zhou Y. Determination of Polycyclic Aromatic Hydrocarbons (PAHs) and Phthalates in Human Placenta by Mixed Hexane/Ether Extraction and Gas Chromatography-Mass Spectrometry/Mass Spectrometry (GC-MS/MS). Metabolites 2023; 13:978. [PMID: 37755258 PMCID: PMC10536546 DOI: 10.3390/metabo13090978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 08/25/2023] [Accepted: 08/26/2023] [Indexed: 09/28/2023] Open
Abstract
In this study, we evaluated the extraction effect of three different extractants, namely hexane + ether (v/v = 3:1), acetonitrile and ethyl acetate, on polycyclic aromatic hydrocarbons (PAHs) and phthalic acid esters (PAEs) in placenta detected and analysed by triple quadrupole gas chromatography-mass spectrometry (GC-MS/MS). The results showed that n-hexane + ether (v/v = 3:1) had the highest extraction efficiency. Under the optimal conditions, the limits of detection (LOD) for the 10 PAHs were 0.003-0.0167 μg/L with relative standard deviations (RSD) of 1.4-5.48% and detection rates of 68.19-107.05%, and the correlation coefficients were (R2, 0.9982-0.9999). The LODs for the nine PAEs were 0.0015-3.5714 μg/L and the correlation coefficients were (R2, 0.9982-0.9999). The limits of detection (S/N = 3) for the nine PAHs were 0.0015-0.5714 μg/L with relative standard deviations (RSD) of 3.15-8.37%, and the detection rates were 80.45-112.59% with correlations of (R2, 0.9972-0.9998). The method was applied to the analysis of PAHs and phthalates in placenta samples from pregnant women. The method's accuracy and applicability were demonstrated. In comparison with other methods for the detection of PAEs and PAHs, the method proposed in this paper has a wider linear range, lower minimum detection limit and comparable recovery with good correlation. This paper is dedicated to providing another method for improving the performance of extracting solid tissues.
Collapse
Affiliation(s)
- Lin Tao
- Key Laboratory, School of Public Health, Zunyi Medical University, No.6 Xuefu West Road, Xinpu Street, Honghuagang District, Zunyi 563006, China
| | - Yingkuan Tian
- Key Laboratory, School of Public Health, Zunyi Medical University, No.6 Xuefu West Road, Xinpu Street, Honghuagang District, Zunyi 563006, China
| | - Dengqing Liao
- Key Laboratory, School of Public Health, Zunyi Medical University, No.6 Xuefu West Road, Xinpu Street, Honghuagang District, Zunyi 563006, China
| | - Songlin An
- Key Laboratory, School of Public Health, Zunyi Medical University, No.6 Xuefu West Road, Xinpu Street, Honghuagang District, Zunyi 563006, China
| | - Wei Chen
- Key Laboratory, School of Public Health, Zunyi Medical University, No.6 Xuefu West Road, Xinpu Street, Honghuagang District, Zunyi 563006, China
| | - Xiang Liu
- Key Laboratory, School of Public Health, Zunyi Medical University, No.6 Xuefu West Road, Xinpu Street, Honghuagang District, Zunyi 563006, China
| | - Pei Xu
- Key Laboratory, School of Public Health, Zunyi Medical University, No.6 Xuefu West Road, Xinpu Street, Honghuagang District, Zunyi 563006, China
| | - Xubo Shen
- Key Laboratory, School of Public Health, Zunyi Medical University, No.6 Xuefu West Road, Xinpu Street, Honghuagang District, Zunyi 563006, China
| | - Yuanzhong Zhou
- Key Laboratory, School of Public Health, Zunyi Medical University, No.6 Xuefu West Road, Xinpu Street, Honghuagang District, Zunyi 563006, China
| |
Collapse
|
3
|
Luís C, Algarra M, Câmara JS, Perestrelo R. Comprehensive Insight from Phthalates Occurrence: From Health Outcomes to Emerging Analytical Approaches. TOXICS 2021; 9:toxics9070157. [PMID: 34357900 PMCID: PMC8309855 DOI: 10.3390/toxics9070157] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2021] [Revised: 06/27/2021] [Accepted: 06/28/2021] [Indexed: 11/16/2022]
Abstract
Phthalates are a group of chemicals used in a multitude of important industrial products (e.g., medical devices, children's toys, and food packages), mainly as plasticizers to improve mechanical properties such as flexibility, transparency, durability, and longevity of polyvinyl chloride (PVC). The wide occurrence of phthalates in many consumer products, including foods (e.g., bottled water, soft drinks, wine, milk, and meat) brings that most people are exposed to phthalates every day, which raises some concerns. Adverse health outcomes from phthalates exposure have been associated with endocrine disruption, deformities in the human reproductive system, increased risk of preterm birth, carcinogen exposure, among others. Apprehension related to the health risks and ubiquitous incidence of phthalates in foods inspires the development of reliable analytical approaches that allow their detection and quantification at trace levels. The purpose of the current review is to provide information related to the presence of phthalates in the food chain, highlighting the health risks associated with their exposure. Moreover, an overview of emerging extraction procedures and high-resolution analytical approaches for a comprehensive quantification of phthalates is presented.
Collapse
Affiliation(s)
- Catarina Luís
- CQM-Centro de Química da Madeira, Campus da Penteada, Universidade da Madeira, 9020-105 Funchal, Portugal; (C.L.); (J.S.C.)
- Faculdade de Ciências da Vida, Unidade de Ciências Médicas, Universidade da Madeira, Campus Universitário da Penteada, 9020-105 Funchal, Portugal
| | - Manuel Algarra
- Department of Inorganic Chemistry, Faculty of Science, Campus de Teatinos s/n, University of Málaga, 29071 Malaga, Spain;
| | - José S. Câmara
- CQM-Centro de Química da Madeira, Campus da Penteada, Universidade da Madeira, 9020-105 Funchal, Portugal; (C.L.); (J.S.C.)
- Departamento de Química, Faculdade de Ciências e Engenharia, Campus da Penteada, Universidade da Madeira, 9020-105 Funchal, Portugal
| | - Rosa Perestrelo
- CQM-Centro de Química da Madeira, Campus da Penteada, Universidade da Madeira, 9020-105 Funchal, Portugal; (C.L.); (J.S.C.)
- Correspondence: ; Tel.: +351-291-705-224
| |
Collapse
|