1
|
Poole CF. Determination of solvation parameter model compound descriptors by gas chromatography. J Chromatogr A 2024; 1717:464711. [PMID: 38320433 DOI: 10.1016/j.chroma.2024.464711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2024] [Revised: 01/31/2024] [Accepted: 02/01/2024] [Indexed: 02/08/2024]
Abstract
The solvation parameter model uses five system independent descriptors to characterize compound properties defined as excess molar refraction, E, dipolarity/polarizability, S, hydrogen-bond acidity, A, hydrogen-bond basicity, B, and the gas-liquid partition constant at 25 °C on n-hexadecane, L, to model transfer properties in gas-condensed phase biphasic systems. The E descriptor for compounds liquid at 20 °C is available by calculation using a refractive index value while E for solid compounds at 20 °C and the S, A, B, and L descriptors are determined by experiment. As a single-technique approach, it is shown that with up to 20 retention factor measurements on four columns comprising a poly(siloxane) containing methyloctyl or dimethyldiphenylsiloxane monomers (SPB-Octyl or HP-5), a poly(siloxane) containing methyltrifluoropropylsiloxane monomers (Rtx-OPP or DB-210), a poly(siloxane) containing bis(cyanopropylsiloxane) monomers (HP-88 or SGE BPX-90), and a poly(ethylene glycol) stationary phase (DB-WAXetr or HP-INNOWAX) are suitable for assigning the S, A, and L descriptors. Using the descriptors in the updated WSU compound descriptor database as target values the average absolute error in the descriptor assignments for 52 varied compounds in the temperature range 60-140 °C was 0.072 for E, 0.016 for S, 0.008 for A, and 0.022 for L corresponding to 30 %, 3.5 %, and 0.6 % as a relative average absolute error for E, S, and L, respectively. For the higher temperature range of 160-240 °C and 34 varied compounds that are liquid at 20 °C the average absolute error for the S, A and L descriptors was 0.026, 0.020, and 0.031, respectively, with the largest relative average absolute error for S of 3.2 % (< 1 % for the L descriptor). For 35 varied compounds that are solid at 20 °C the relative absolute error for the E, S, A, and L descriptors in the higher temperature range was 0.068, 0.035, 0.020, and 0.020, respectively, with a relative average absolute error for E (6.5 %), S (3.5 %) and L (0.88 %). The S, A, and L descriptor can be accurately assigned on the four-column system over a wide temperature range. The E descriptor for solid compounds at 20 °C exhibits greater variability than desirable. The B descriptor cannot be assigned by the four-column system, which lack hydrogen-bond acid functional groups, and is only poorly assigned on the weak hydrogen-bond acid ionic liquid column SLB-IL100.
Collapse
Affiliation(s)
- Colin F Poole
- Department of Chemistry, Wayne State University, Detroit, MI 48202, USA.
| |
Collapse
|
2
|
Castro RSDS, Dória AR, Costa F, Mattedi S, Eguiluz KIB, Salazar-Banda GR. Dipropyl ammonium ionic liquids to prepare Ti/RuO 2-Sb 2O 4 anodes at different calcination temperatures. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2023:10.1007/s11356-023-29742-9. [PMID: 37723391 DOI: 10.1007/s11356-023-29742-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Accepted: 09/02/2023] [Indexed: 09/20/2023]
Abstract
The development of technologies capable of producing efficient and economically viable anodes is essential for the electrochemical treatment of water contaminated with complex organic pollutants. In this context, the use of ionic liquids as solvents to prepare mixed metal oxide (MMO) anodes has proven to be an up-and-coming alternative. Here, we analyze the influence of the temperature of calcination (300, 350, and 400 ºC) on the production of Ti(RuO2)0.8-(Sb2O4)0.2 anodes made using the thermal decomposition method using three ionic liquids (IL) as solvents: dipropyl ammonium acetate (DPA-Ac), dipropyl ammonium propionate (DPA-Pr), and dipropyl ammonium butyrate (DPA-Bu). The decomposition temperature for all IL, accessed by thermogravimetry, is below 200 ºC. Physical and electrochemical analyses demonstrate that the calcination temperature of the anodes is decisive for their durability and electrochemical properties. Anodes prepared with DPA-Bu at 350 ºC show higher stability (around 35 h) than those made with other ILs at temperatures of 300 and 400 ºC and improved results in terms of 4-NP mineralization, where 97% of TOC removal was achieved in 120 min. It could be verified that the calcination temperature and IL employed had a decisive influence on the characteristics of the presented anodes. Therefore, the anode prepared with DPA-Bu at 350 ºC is promising for application in the degradation of organic compounds.
Collapse
Affiliation(s)
- Raíra Souza de Santana Castro
- Graduate Program in Processes Engineering (PEP), University Tiradentes, Aracaju, SE, Brazil
- Electrochemistry and Nanotechnology Laboratory, Institute of Technology and Research (ITP), Aracaju, SE, Brazil
| | - Aline Resende Dória
- Graduate Program in Processes Engineering (PEP), University Tiradentes, Aracaju, SE, Brazil
- Electrochemistry and Nanotechnology Laboratory, Institute of Technology and Research (ITP), Aracaju, SE, Brazil
| | - Fabio Costa
- Graduate Program in Chemical Engineering, Polytechnic School, Federal University of Bahia (UFBA), Salvador, BA, CEP 40210-630, Brazil
| | - Silvana Mattedi
- Graduate Program in Chemical Engineering, Polytechnic School, Federal University of Bahia (UFBA), Salvador, BA, CEP 40210-630, Brazil
| | - Katlin Ivon Barrios Eguiluz
- Graduate Program in Processes Engineering (PEP), University Tiradentes, Aracaju, SE, Brazil
- Electrochemistry and Nanotechnology Laboratory, Institute of Technology and Research (ITP), Aracaju, SE, Brazil
| | - Giancarlo Richard Salazar-Banda
- Graduate Program in Processes Engineering (PEP), University Tiradentes, Aracaju, SE, Brazil.
- Electrochemistry and Nanotechnology Laboratory, Institute of Technology and Research (ITP), Aracaju, SE, Brazil.
| |
Collapse
|
3
|
Cheng W, Xian F, Zhou Z, Hu K, Gao J. Solubility and Stability of Carotenoids in Ammonium- and Phosphonium-Based Ionic Liquids: Effect of Solvent Nature, Temperature and Water. Molecules 2023; 28:molecules28083618. [PMID: 37110853 PMCID: PMC10143741 DOI: 10.3390/molecules28083618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Revised: 04/18/2023] [Accepted: 04/19/2023] [Indexed: 04/29/2023] Open
Abstract
Ionic liquids (ILs) have arisen as alternatives to organic solvents and been used in natural pigment extraction in recent decades. However, the solubility and stability of carotenoids in phosphonium- and ammonium-based ILs are insufficiently explored. In this work, the physicochemical properties of the ILs, and the dissolution behavior and storage stability of three carotenoids (astaxanthin, β-carotene, and lutein) in the IL aqueous solution were investigated. The results showed that the solubility of the carotenoids in the acidic IL solution is higher than that in the alkaline IL solution, and the optimal pH is about 6. The solubility of astaxanthin (40 mg/100 g), β-carotene (105 mg/100 g), and lutein (5250 mg/100 g) was the highest in tributyloctylphosphonium chloride ([P4448]Cl) due to the van der Waals forces with [P4448]+ and hydrogen bonding with Cl-. A high temperature was beneficial to improve the solubility, but it can reduce the storage stability. Water has no significant effect on the carotenoid stability, but a high water content decreases the carotenoid solubility. A IL water content of 10-20%, an extraction temperature of 338.15 K, and a storage temperature of less than 298.15 K are beneficial for reducing the IL viscosity, improving carotenoid solubility, and maintaining good stability. Moreover, a linear correlation was found between the color parameters and carotenoid contents. This study provides some guidance for screening suitable solvents for carotenoid extraction and storage.
Collapse
Affiliation(s)
- Wanting Cheng
- Collage of Food Science, Guangdong Pharmaceutical University, Guangzhou 510006, China
| | - Feng Xian
- Collage of Food Science, Guangdong Pharmaceutical University, Guangzhou 510006, China
| | - Zhanluo Zhou
- Collage of Food Science and Technology, Guangdong Ocean University, Zhanjiang 524091, China
| | - Kun Hu
- Collage of Food Science, Guangdong Pharmaceutical University, Guangzhou 510006, China
| | - Jing Gao
- Collage of Food Science, Guangdong Pharmaceutical University, Guangzhou 510006, China
| |
Collapse
|
4
|
Poole CF. Selectivity evaluation of extraction systems. J Chromatogr A 2023; 1695:463939. [PMID: 36996617 DOI: 10.1016/j.chroma.2023.463939] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 03/19/2023] [Accepted: 03/20/2023] [Indexed: 03/30/2023]
Abstract
Extraction is the most common sample preparation technique prior to chromatographic analysis for samples which are too complex, too dilute, or contain matrix components incompatible with the further use of the separation system or interfere in the detection step. The most important extraction techniques are biphasic systems involving the transfer of target compounds from the sample to a different phase ideally accompanied by no more than a tolerable burden of co-extracted matrix compounds. The solvation parameter model affords a general framework to characterize biphasic extraction systems in terms of their relative capability for solute-phase intermolecular interactions (dispersion, dipole-type, hydrogen bonding) and within phase solvent-solvent interactions for cavity formation (cohesion). The approach is general and allows the comparison of liquid and solid extraction phases using the same terms and is used to explain the features important for the selective enrichment of target compounds by a specific extraction phase using solvent extraction, liquid-liquid extraction, and solid-phase extraction for samples in a gas, liquid, or solid phase. Hierarchical cluster analysis with the system constants of the solvation parameter model as variables facilitates the selection of solvents for extraction, the identification of liquid-liquid distribution systems with non-redundant selectivity, and evaluation of different approaches using liquids and solids for the isolation of target compounds from different matrices.
Collapse
|
5
|
Poole CF. The influence of descriptor database selection on the solvation parameter model for separation processes. J Chromatogr A 2023; 1692:463851. [PMID: 36773399 DOI: 10.1016/j.chroma.2023.463851] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 02/02/2023] [Accepted: 02/03/2023] [Indexed: 02/10/2023]
Abstract
The distribution of neutral compounds in biphasic separation systems can be described by the solvation parameter model using six solute properties, or descriptors. These descriptors characterize the size (McGowan's characteristic volume), V, excess molar refraction, E, dipolarity/polarizability, S, hydrogen-bond acidity and basicity, A and B, and the gas-liquid partition constant on n-hexadecane at 298.15 K, L. McGowan's characteristic volume and the excess molar refraction for liquids are available by calculation (E requires and experimental refractive index). The other descriptors and excess molar refraction for solids are experimental quantities and subject to greater variation or are estimated using computational or empirical models. Solute descriptors for several thousand compounds are available in the Abraham descriptor database and for several hundred compounds in the WSU descriptor database. These publicly accessible databases were developed independently using different approaches and for many compounds provide different descriptor values. In this report we evaluate the effect of mixing descriptors from the two databases on modeling chromatographic retention factors and liquid-liquid partition constants. It is shown that the two descriptor databases are not interchangeable. The WSU descriptor database consistently demonstrates improved model quality as determined by statistical parameters. Model system constants exhibit a general dependence on database selection with an approximately linear trend as a function of the fraction of compounds assigned descriptors from either database. There is no general model performance advantage to using mixed descriptor datasets and no real cause for concern for relatively large datasets containing < 15 % of compounds with descriptors assigned from the other database. For small datasets, descriptor quality is an important variable for adequate model performance.
Collapse
Affiliation(s)
- Colin F Poole
- Department of Chemistry, Wayne State University, Detroit, MI, 48202, USA.
| |
Collapse
|
6
|
Recent advances for estimating environmental properties for small molecules from chromatographic measurements and the solvation parameter model. J Chromatogr A 2023; 1687:463682. [PMID: 36502643 DOI: 10.1016/j.chroma.2022.463682] [Citation(s) in RCA: 14] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 11/24/2022] [Accepted: 11/24/2022] [Indexed: 11/30/2022]
Abstract
The transfer of neutral compounds between immiscible phases in chromatographic or environmental systems can be described by six solute properties (solute descriptors) using the solvation parameter model. The solute descriptors are size (McGowan's characteristic volume), V, excess molar refraction, E, dipolarity/polarizability, S, hydrogen-bond acidity and basicity, A and B, and the gas-liquid partition constant on n-hexadecane at 298.15 K, L. V and E for liquids are accessible by calculation but the other descriptors and E for solids are determined experimentally by chromatographic, liquid-liquid partition, and solubility measurements. These solute descriptors are available for several thousand compounds in the Abraham solute descriptor databases and for several hundred compounds in the WSU experimental solute descriptor database. In the first part of this review, we highlight features important in defining each descriptor, their experimental determination, compare descriptor quality for the two organized descriptor databases, and methods for estimating Abraham solute descriptors. In the second part we focus on recent applications of the solvation parameter model to characterize environmental systems and its use for the identification of surrogate chromatographic models for estimating environmental properties.
Collapse
|
7
|
Poole CF. Applications of the solvation parameter model in thin-layer chromatography. JPC-J PLANAR CHROMAT 2022. [DOI: 10.1007/s00764-022-00156-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
8
|
Experimental Research of Gaseous Emissions Impact on the Performance of New-Design Cylindrical Multi-Channel Cyclone with Adjustable Half-Rings. SUSTAINABILITY 2022. [DOI: 10.3390/su14020902] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Cyclones are widely used for separating particles from gas in energy production objects. The efficiency of conventional centrifugal air cleaning devices ranges from 85 to 90%, but the weakness of many cyclones is the low collection efficiency of particles less than 10 μm in diameter. The novelty of this work is the research of the channel-type treatment device, with few levels adapted for precipitation of fine particulate matter, acting by a centrifugal and filtration principle. Many factors have an impact on cyclone efficiency—humidity, temperature, gas (air) composition, airflow velocity and etc. Many scientists evaluated only the effect of origin and size of PM on cyclone efficiency. The effect of gas (air) composition and temperature, and humidity on the multi-channel cyclone-separator efficiency still demands contributions. Complex theoretical and experimental research on air flow parameters and the efficiency of a cylindrical eight-channel system with adjustable half-rings for removing fine-dispersive particles (<20 μm) was carried out. The impact of air humidity and temperature on air flow, and gaseous smoke components on the removal of wood ashes was analyzed. The dusty gas flow was regulated. During the experiment, the average velocity of the cyclone was 16 m/s, and the temperature was 20–50 °C. The current paper presents experimental research results of wood ash removal in an eight-channel cyclone and theoretical methodology for the calculation of airflow parameters and cyclone effectiveness.
Collapse
|
9
|
Zhang Y, Zhang W, Zhang L, Song G, Wang N, Xu W, Huang W. A molecularly imprinted electrochemical BPA sensor based on multi-walled carbon nanotubes modified by CdTe quantum dots for the detection of bisphenol A. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106737] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
10
|
Chromatographic Method for Evaluation of Polymeric GC Stationary Phases Ageing Using the Novel Non-Cross-Linked Poly(3-(Tributoxysilyl)Tricyclononene-7) as the Model Stationary Phase. Polymers (Basel) 2021; 13:polym13111899. [PMID: 34200512 PMCID: PMC8201275 DOI: 10.3390/polym13111899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 06/02/2021] [Accepted: 06/05/2021] [Indexed: 11/16/2022] Open
Abstract
The chromatographic properties and thermal stability are investigated for the polymeric stationary phase based on the norbornene polymer. It was shown that without additional cross-linking, poly(3-(tributoxysilyl)tricyclononene-7) demonstrates properties similar to liquid chromatographic stationary phases. It was also found to be more thermally stable than previously studied trimethylsilyl- and trimethoxysilyl- derivatives. The long-term heating at 170 °C resulted in an increase of mass transfer rate between stationary and mobile phases which could be observed as a decrease of parameter C of Van Deemter equation. This effect is rather unusual, as the polymeric stationary phases tend in decrease of the layer volume and porosity while ageing. Additionally, the values of thermodynamic parameters of sorption are calculated for the polymeric stationary phase: enthalpy of sorption varied −28 to −37 kJ/mol, entropy change was −41 to −51 J/mol K. The compensation curves were plotted for the alkanes, arenes, and alcohols, and the parameters of compensation plot were calculated, demonstrating the different sorption mechanisms both for hydrocarbons and oxygen-containing compounds, and different classes of organic compounds.
Collapse
|