1
|
Gély C, Monneau YR, Hologne M, Faure K. Impact of conditioning runs on hydrophilic interaction chromatography repeatability and its application as a second dimension in online comprehensive two-dimensional liquid chromatography. J Sep Sci 2024; 47:e2300935. [PMID: 38801757 DOI: 10.1002/jssc.202300935] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Revised: 04/08/2024] [Accepted: 04/12/2024] [Indexed: 05/29/2024]
Abstract
A common separation approach for polar compounds involves coupling reversed-phase liquid chromatography (RPLC) with hydrophilic interaction chromatography (HILIC) in two-dimensional chromatography. The higher proportion of acetonitrile used in the HILIC mobile phase, which enhances mass spectrometry detection, encourages its use in the second dimension. Previous studies demonstrated that the HILIC column can be partially equilibrated within very short timeframes without compromising retention time stability, rendering it suitable in online comprehensive two-dimensional liquid chromatography (LC×LC) setups. In addition, a specific number of conditioning cycles seems necessary to establish stable retention times. Here, the repeatability of HILIC when employed as second dimension in LC×LC was investigated, with a focus on determining the required number of conditioning cycles to achieve repeatable retention times. Various parameters influenced by the LC×LC online modulation system were studied, such as steep gradient slopes up to 8%, and very short equilibration times, less than or equal to dead time, as well as injection volume and solvent, which depend on the first dimension. Finally, the use of HILIC as a second dimension with tailored conditioning runs was applied to the analysis of hyaluronic acid hydrogel digests. The application of an RPLC×HILIC method using five conditioning runs yielded exceptional stability in second-dimension retention times.
Collapse
Affiliation(s)
- Clémence Gély
- Universite Claude Bernard Lyon1, ISA, UMR5280, CNRS, Villeurbanne, France
| | - Yoan R Monneau
- Universite Claude Bernard Lyon1, ISA, UMR5280, CNRS, Villeurbanne, France
| | - Maggy Hologne
- Universite Claude Bernard Lyon1, ISA, UMR5280, CNRS, Villeurbanne, France
| | - Karine Faure
- Universite Claude Bernard Lyon1, ISA, UMR5280, CNRS, Villeurbanne, France
| |
Collapse
|
2
|
Aebischer MK, Chapel S, Guillarme D, Heinisch S. Theoretical and practical guidelines for solvent dilution between the two dimensions in online comprehensive two-dimensional liquid chromatography. J Chromatogr A 2024; 1718:464725. [PMID: 38364617 DOI: 10.1016/j.chroma.2024.464725] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2023] [Revised: 01/23/2024] [Accepted: 02/07/2024] [Indexed: 02/18/2024]
Abstract
Online comprehensive two-dimensional liquid chromatography (online LC x LC) has become increasingly popular. Among the different chromatographic modes that can be combined, hydrophilic interaction chromatography (HILIC) and reversed-phase liquid chromatography (RPLC) are particularly interesting because they offer a high degree of orthogonality. However, this combination remains complex due to the incompatibility of the solvents in the two dimensions. To avoid this problem, it is possible to dilute the first dimension (1D) effluent with (zdilution -1) volumes of a weaker solvent added to one volume of 1D-effluent, where zdilution represents the extent to which the fraction volume has been multiplied. This can be done using either active solvent modulation technology or an additional pump, prior to the second dimension analysis. The objective of this study was to develop theoretical models to predict whether or not dilution can be effective, and, if so, what is the minimum zdilution value required. This approach is based on the calculation of the ratio (called xdilution) between the peak standard deviation due to the injection process and the peak standard deviation in the absence of extra-column dispersion. xdilution was calculated from theoretical relationships and plotted as a function of zdilution, to predict the value required to obtain good peak shapes for the compound of interest. The maximum xdilution value was found to be of the order of 1 for chromatographically acceptable peak shapes. The proposed theoretical approach was experimentally validated on a number of representative small molecules and peptides. Agreement between experimental results and theoretical models was very high, especially for small molecules. Finally, it is shown that this approach helps to predict the most appropriate set of conditions in HILIC x RPLC, depending on the compounds to be separated.
Collapse
Affiliation(s)
- Megane K Aebischer
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel Servet 1, 1211, Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211, Geneva 4, Switzerland
| | - Soraya Chapel
- Laboratoire SMS-EA3233, Université Rouen Normandie, FR3038 INC3M, Unirouen, Place Emile Blondel, F-76821, Mont-Saint-Aignan, France
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel Servet 1, 1211, Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211, Geneva 4, Switzerland.
| | - Sabine Heinisch
- Université de Lyon, Institut des Sciences Analytiques, UMR 5280 CNRS, 5 rue de la Doua, 69100, Villeurbanne, France
| |
Collapse
|
3
|
Pardon M, Reis R, de Witte P, Chapel S, Cabooter D. Detailed comparison of in-house developed and commercially available heart-cutting and selective comprehensive two-dimensional liquid chromatography systems. J Chromatogr A 2024; 1713:464565. [PMID: 38096685 DOI: 10.1016/j.chroma.2023.464565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 11/21/2023] [Accepted: 12/05/2023] [Indexed: 01/08/2024]
Abstract
Recently, two-dimensional liquid chromatography (2D-LC) has become a popular approach to analyze complex samples. This is partly due to the introduction of commercial 2D-LC systems. In the past, 2D-LC was carried out on in-house developed setups, typically consisting of several switching valves and sample loops as the interface between the two dimensions. Commercial systems usually offer different 2D-LC modes in combination with specialized software to operate the instrument and analyze the data. This makes them highly user-friendly, however, at an increased cost compared to in-house developed setups. This study aims to make a comparison between an in-house developed 2D-LC setup and a commercially available 2D-LC instrument. The comparison is made based on experimental differences, in addition to more general differences, including cost price, flexibility, and ease of operation. Special attention is also paid to the different strategies to deal with the mobile phase incompatibility between the highly orthogonal separation mechanisms considered in this work: hydrophilic interaction liquid chromatography (HILIC) and reversed-phase LC (RPLC). For the commercial 2D-LC instrument, this is done using active solvent modulation (ASM), a valve-based approach allowing the on-line dilution of the effluent eluting from the first dimension column before transfer to the second dimension (2D) column. For the in-house developed setup, a combination of restriction capillaries and a trap column is used. Using a sample of 28 compounds with a large polarity range, peak shapes and recoveries of the 2D-chromatograms are compared for both setups. For early eluting compounds, the selective comprehensive approach, currently only possible on the commercial 2D-LC instrument, results in the best peak shapes and recoveries, however, at the cost of an increased analysis time. In general, depending on the analytical goal (single heart-cut versus full-comprehensive 2D-LC), an in-house developed system can be satisfactory for the analysis of specific target compounds/samples. For more complex problems, it can be interesting to use a more specialized commercial 2D-LC instrument. Overall, this comparison study provides advice for analytical scientists, who are considering to use 2D-LC, on the type of equipment to consider, depending on the needs of their particular applications.
Collapse
Affiliation(s)
- Marie Pardon
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium; Laboratory for Molecular Biodiscovery, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Rafael Reis
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Peter de Witte
- Laboratory for Molecular Biodiscovery, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Soraya Chapel
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium
| | - Deirdre Cabooter
- Laboratory for Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, KU Leuven, Herestraat 49 Box 824, 3000 Leuven, Belgium.
| |
Collapse
|
4
|
Pérez-Robles R, Fekete S, Kormány R, Navas N, Guillarme D. Improved sample introduction approach in hydrophilic interaction liquid chromatography to avoid breakthrough of proteins. J Chromatogr A 2024; 1713:464498. [PMID: 37980809 DOI: 10.1016/j.chroma.2023.464498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 11/07/2023] [Accepted: 11/08/2023] [Indexed: 11/21/2023]
Abstract
When therapeutic proteins are analysed under hydrophilic interaction liquid chromatography (HILIC) conditions, there is an inherent mismatch between the sample diluent (proteins must be solubilised in aqueous media) and the mobile phase, which is mostly composed of aprotic solvent (acetonitrile). This difference in eluent strength between sample diluent and mobile phase is responsible for severe analyte breakthrough and peak distortion. As demonstrated with therapeutic proteins of different sizes (insulin of 6 kDa, anakinra of 17 kDa and rituximab subunits of 25 and 50 kDa), only very small volumes of 0.1-0.2 µL can be injected without breakthrough effects, when performing rapid analysis on short HILIC columns of 20-50 mm, leading to poor sensitivity. In order to avoid the undesired effect of the strong sample diluent, a special injection program should be preferred. This consists in the addition and automatic injection of a defined volume of weak solvent (acetonitrile) along with the sample to increase retention factors during sample loading. Various injection programs were tested, including the addition of a pre-injection or post-injection or both (bracketed injection) of acetonitrile plugs. Several weak to strong injection solvent ratios of 1:1, 1:2, 1:4 and 1:10 were tested. Our work proves that the addition of a pre-plug solvent with a weak vs. strong injection solvent ratio of 1:10 is a valuable strategy to inject relatively large volumes of proteins in HILIC, regardless of column dimensions, thus maximising sensitivity. No peak deformation or breakthrough was observed under these conditions. However, it is important to note that peak broadening (40 % larger peaks) was observed when the injection program increased the injection solvent ratio from 1:1 to 1:10. Finally, this strategy was applied to a wide range of therapeutic mAb products with different physico-chemical properties. In all cases, relatively large volumes can be successfully injected onto small volume HILIC columns using a purely aqueous sample diluent, as long as an appropriate (weak) solvent pre-injection is applied.
Collapse
Affiliation(s)
- Raquel Pérez-Robles
- Instituto de Investigación Biosanitaria de Granada (ibs.GRANADA), Granada, Spain; Department of Analytical Chemistry, Science Faculty, University of Granada, Granada, Spain; Fundación para la Investigación Biosanitaria de Andalucía Oriental-Alejandro Otero, Granada, Spain
| | | | - Róbert Kormány
- Egis Pharmaceuticals Plc., Keresztúri út 30-38, 1106, Budapest, Hungary
| | - Natalia Navas
- Instituto de Investigación Biosanitaria de Granada (ibs.GRANADA), Granada, Spain; Department of Analytical Chemistry, Science Faculty, University of Granada, Granada, Spain
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland; Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU - Rue Michel Servet 1, 1211 Geneva 4, Switzerland.
| |
Collapse
|
5
|
Chapel S, Rouvière F, Guillarme D, Heinisch S. Reversed HILIC Gradient: A Powerful Strategy for On-Line Comprehensive 2D-LC. Molecules 2023; 28:molecules28093907. [PMID: 37175317 PMCID: PMC10179806 DOI: 10.3390/molecules28093907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/25/2023] [Accepted: 04/27/2023] [Indexed: 05/15/2023] Open
Abstract
The aim of the present work is to evaluate the possibilities and limitations of reversed hydrophilic interaction chromatography (revHILIC) mode in liquid chromatography (LC). This chromatographic mode consists of combining a highly polar stationary phase (bare silica) with a gradient varying from very low (1-5%) to high (40%) acetonitrile content (reversed gradient compared to HILIC). The retention behavior of revHILIC was first compared with that of reversed-phase LC (RPLC) and HILIC using representative mixtures of peptides and pharmaceutical compounds. It appears that the achievable selectivity can be ranked in the order RPLC > revHILIC > HILIC with the two different samples. Next, two-dimensional liquid chromatography (2D-LC) conditions were evaluated by combining RPLC, revHILIC, or HILIC with RPLC in an on-line comprehensive (LC × LC) mode. evHILIC × RPLC not only showed impressive performance in terms of peak capacity and sensitivity, but also provided complementary selectivity compared to RPLC × RPLC and HILIC × RPLC. Indeed, both the elution order and the retention time range differ significantly between the three techniques. In conclusion, there is no doubt that revHILIC should be considered as a viable option for 2D-LC analysis of small molecules and also peptides.
Collapse
Affiliation(s)
- Soraya Chapel
- Institut Des Sciences Analytiques, Université de Lyon, UMR 5280, CNRS, 5 rue de la Doua, 69100 Villeurbanne, France
- Pharmaceutical Analysis, Department of Pharmaceutical and Pharmacological Sciences, University of Leuven (KU Leuven), Herestraat 49, 3000 Leuven, Belgium
| | - Florent Rouvière
- Institut Des Sciences Analytiques, Université de Lyon, UMR 5280, CNRS, 5 rue de la Doua, 69100 Villeurbanne, France
| | - Davy Guillarme
- School of Pharmaceutical Sciences, University of Geneva, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
- Institute of Pharmaceutical Sciences of Western Switzerland, University of Geneva, CMU-Rue Michel Servet 1, 1211 Geneva 4, Switzerland
| | - Sabine Heinisch
- Institut Des Sciences Analytiques, Université de Lyon, UMR 5280, CNRS, 5 rue de la Doua, 69100 Villeurbanne, France
| |
Collapse
|
6
|
Optimizing transfer and dilution processes when using active solvent modulation in on-line two-dimensional liquid chromatography. Anal Chim Acta 2023; 1252:341040. [PMID: 36935135 DOI: 10.1016/j.aca.2023.341040] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 03/01/2023] [Accepted: 03/02/2023] [Indexed: 03/06/2023]
Abstract
Two-dimensional liquid chromatography (2D-LC) is becoming increasingly popular for the analysis of complex samples, which is partly due to the recent introduction of commercial 2D-LC systems. To deal with the mobile phase incompatibility between highly orthogonal retention mechanisms, such as hydrophilic interaction liquid chromatography (HILIC) and reversed-phase LC (RPLC), several strategies have been introduced over the years. One of these strategies is active solvent modulation (ASM), a valve-based approach allowing the on-line dilution of the effluent eluting from the first dimension before transfer to the second dimension. This strategy has gained a lot of attention and holds great potential, however, no clear guidelines are currently in place for its use. Therefore, this study aims to investigate how the ASM process can be optimized when using highly incompatible LC combinations, such as HILIC and RPLC, in a simplified selective comprehensive 2D-LC set-up (sHILIC x RPLC) to suggest guidelines for future users. Using a representative sample, the dilution factor (DF), the duration of the ASM phase, the filling percentage of the sample loops, and their unloading configuration are investigated and optimized. It is observed that a DF of 10 with an optimal ASM phase duration, a sample loop filling of maximum 25%, and an unloading configuration in backflush mode, result in the best peak shapes, intensities, and recoveries for early eluting compounds, while keeping the total analysis time minimal. Based on these results, some general recommendations are made that could also be applied in other 2D-LC modes, such as comprehensive 2D-LC (LC x LC), heart-cutting 2D-LC (LC-LC), and other chromatographic combinations with mobile phase incompatibility issues.
Collapse
|
7
|
Wicht K, Baert M, von Doehren N, Desmet G, de Villiers A, Lynen F. Speeding up temperature-responsive × reversed-phase comprehensive liquid chromatography through the combined exploitation of temperature and flow rate gradients. J Chromatogr A 2022; 1685:463584. [DOI: 10.1016/j.chroma.2022.463584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 10/15/2022] [Accepted: 10/18/2022] [Indexed: 11/27/2022]
|
8
|
Xiang H, Xu P, Qiu H, Wen W, Zhang A, Tong S. Two-dimensional chromatography in screening of bioactive components from natural products. PHYTOCHEMICAL ANALYSIS : PCA 2022; 33:1161-1176. [PMID: 35934878 DOI: 10.1002/pca.3168] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 07/20/2022] [Accepted: 07/21/2022] [Indexed: 06/15/2023]
Abstract
INTRODUCTION Screening and analysis of bioactive components from natural products is a fundamental part of new drug development and innovation. Two-dimensional (2D) chromatography has been demonstrated to be an effective method for screening and preparation of specific bioactive components from complex natural products. OBJECTIVE To collect details of application of 2D chromatography in screening of natural product bioactive components and to outline the research progress of different separation mechanisms and strategies. METHODOLOGY Three screening strategies based on 2D chromatography are reviewed, including traditional separation-based screening, bioactivity-guided screening and affinity chromatography-based screening. Meanwhile, in order to cover these aspects, selections of different separation mechanisms and modes are also presented. RESULTS Compared with traditional one-dimensional (1D) chromatography, 2D chromatography has unique advantages in terms of peak capacity and resolution, and it is more effective for screening and identifying bioactive components of complex natural products. CONCLUSION Screening of natural bioactive components using 2D chromatography helps separation and analysis of complex samples with greater targeting and relevance, which is very important for development of innovative drug leads.
Collapse
Affiliation(s)
- Haiping Xiang
- College of Pharmaceutical Science, Zhejiang University of Technology, Huzhou, China
| | - Ping Xu
- College of Pharmaceutical Science, Zhejiang University of Technology, Huzhou, China
| | - Huiyun Qiu
- College of Pharmaceutical Science, Zhejiang University of Technology, Huzhou, China
| | - Weiyi Wen
- College of Pharmaceutical Science, Zhejiang University of Technology, Huzhou, China
| | - Ailian Zhang
- Zhejiang Provincial Key Laboratory of Resources Protection and Innovation of Traditional Chinese Medicine, Zhejiang A&F University, Hangzhou, China
| | - Shengqiang Tong
- College of Pharmaceutical Science, Zhejiang University of Technology, Huzhou, China
| |
Collapse
|
9
|
Wicht K, Baert M, Schipperges S, von Doehren N, Desmet G, Van Geem KM, de Villiers A, Lynen F. Enhanced Sensitivity in Comprehensive Liquid Chromatography: Overcoming the Dilution Problem in LC × LC via Temperature-Responsive Liquid Chromatography. Anal Chem 2022; 94:16728-16737. [DOI: 10.1021/acs.analchem.2c03300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Kristina Wicht
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Mathijs Baert
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| | - Sonja Schipperges
- Agilent Technologies, Hewlett Packard Street 8, D-76337 Waldbronn, Germany
| | - Norwin von Doehren
- Agilent Technologies, Netherlands BV, NL-4330 EA Middelburg, Netherlands
| | - Gert Desmet
- Department of Chemical Engineering, Vrije Universiteit Brussel, Pleinlaan 2, B-1050 Brussel, Belgium
| | - Kevin M. Van Geem
- Laboratory for Chemical Technology (LCT), Department of Materials, Textiles and Chemical Engineering, Faculty of Engineering & Architecture, Ghent University, Technologiepark 125, B-9052 Zwijnaarde, Belgium
| | - André de Villiers
- Department of Chemistry and Polymer Science, University of Stellenbosch, Private Bag X1, ZA-7602 Matieland, South Africa
| | - Frédéric Lynen
- Separation Science Group, Department of Organic and Macromolecular Chemistry, Ghent University, Krijgslaan 281-S4, B-9000 Ghent, Belgium
| |
Collapse
|
10
|
Chapel S, Heinisch S. Strategies to circumvent the solvent strength mismatch problem in online comprehensive two-dimensional liquid chromatography. J Sep Sci 2021; 45:7-26. [PMID: 34525266 DOI: 10.1002/jssc.202100534] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2021] [Revised: 08/23/2021] [Accepted: 08/24/2021] [Indexed: 11/09/2022]
Abstract
On-line comprehensive two-dimensional liquid chromatography is a powerful technique for the separation of highly complex samples. Due to the addition of the second dimension of separation, impressive peak capacities can be obtained within a reasonable analysis time compared to one-dimensional liquid chromatography. In online comprehensive two-dimensional liquid chromatography, the separation power is maximized by selecting two separation dimensions as orthogonal as possible, which most often requires the combination of different mobile phases and stationary phases. The online transfer of a given solvent from the first dimension to the second dimension may cause severe injection effects in the second dimension, mostly due to solvent strength mismatch. Those injection effects may include peak broadening, peak distortion, peak splitting or breakthrough phenomenon. They are often found to reduce significantly the peak capacity and the peak intensity. To overcome such effects, arising specifically in online comprehensive two-dimensional liquid chromatography, different methods have been developed over the years. In this review, we focused on the most recently reported ones. A critical discussion, supported by a theoretical approach, gives an overview of their advantages and drawbacks.
Collapse
Affiliation(s)
- Soraya Chapel
- Université de Lyon, Institut des sciences analytiques, Villeurbanne, France
| | - Sabine Heinisch
- Université de Lyon, Institut des sciences analytiques, Villeurbanne, France
| |
Collapse
|
11
|
A comprehensive study on the phenomenon of total breakthrough in liquid chromatography. J Chromatogr A 2021; 1653:462399. [PMID: 34284262 DOI: 10.1016/j.chroma.2021.462399] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Revised: 07/03/2021] [Accepted: 07/05/2021] [Indexed: 01/07/2023]
Abstract
Differences in elution strength between the sample solvent and the mobile phase usually give rise to undesirable effects on the chromatographic separation, which may range from slight broadening to severe peak deformation or even splitting. In the most extreme case, the retention factor of the analyte at the head of the column is so small at the time of injection that part of the analyte goes through the column with very little interaction with the stationary phase and hence elutes very close to the column dead time. This phenomenon is known as breakthrough. Usually, during breakthrough, the retained peak displays a wide array of deformations and it is not rare that multiple retained peaks appear for a given injected analyte. However, under certain conditions, it has been demonstrated that these deleterious effects could fully disappear, leaving only one breakthrough peak and one symmetrical peak on the chromatogram. This so-called "total breakthrough" phenomenon was recently highlighted in the specific context of the 2D-LC separation of peptides but has yet to be explained. In the present paper, we describe the results of a comprehensive study aiming to better understand and define the conditions of emergence of both breakthrough and total breakthrough phenomena in liquid chromatography. The effects of a broad range of parameters, including the nature of the solute, the retention mechanism, the injection and elution conditions, the column temperature, and the injected sample concentration on the occurrence of both phenomena were investigated. While breakthrough was found to occur for all studied compounds, it appears that the presence of positive charges on the molecule is a prerequisite for observing a total breakthrough phenomenon. Among all the parameters investigated in this work, only the injection conditions and the analyte retention were found to be impactful on the onset of both phenomena. This finding allowed us to suggest one necessary and sufficient condition, relying on the injection of critical volumes to observe each respective phenomenon. These critical volumes only depend on the column dead volume and the retention factor of the analyte in the injection solvent.
Collapse
|