1
|
Sun T, Chen R, Huang Q, Ba M, Cai Z, Chen H, Qi Y, Chen H, Liu X, Nardiello D, Quinto M. Efficient gas chromatographic separation of xylene and other aromatic isomers by using pillar[6]arene-based stationary phase. Anal Chim Acta 2023; 1251:340979. [PMID: 36925280 DOI: 10.1016/j.aca.2023.340979] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 02/13/2023] [Accepted: 02/14/2023] [Indexed: 02/19/2023]
Abstract
The separation of aromatic isomers, in particular xylene isomers, represents a big issue in chemical and petroleum industries, owing to their similar molecular sizes and boiling points. In this work, the investigation ofpillar[6]arene derivative modified by long alkyl chains (P6A-C10) as a stationary phase for high-resolution gas chromatographic (GC) separations of xylene isomers is presented. Pillar[n]arenes are a new class of macrocyclic hosts that can accommodate specific guests due to their highly symmetrical and rigid pillar architectures with π-electron rich cavities. The P6A-C10 column showed high-resolution performance towards xylene isomers, with peculiar advantages if compared with the commercial HP-5, HP-35, DB-17, and PEG-20Mcolumns.A quantum chemistry calculation has been performed, showing a difference in non-covalent interactions with the P6A-C10 pillar framework, which leads to specific selectivity for xylene isomers.Furthermore, the P6A-C10 column exhibited good repeatability.
Collapse
Affiliation(s)
- Tao Sun
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, PR China.
| | - Ruonan Chen
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, Liaoning, PR China
| | - Qiuchen Huang
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, Liaoning, PR China
| | - Mengyi Ba
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, Liaoning, PR China
| | - Zhiqiang Cai
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, Liaoning, PR China.
| | - Haipeng Chen
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, PR China
| | - Yueheng Qi
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, PR China
| | - Hong Chen
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, PR China
| | - Xianming Liu
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, PR China
| | - Donatella Nardiello
- Department of Agriculture, Food, Natural Resource, and Engineering (DAFNE), via Napoli 25, I-71122, Foggia, Italy
| | - Maurizio Quinto
- Department of Agriculture, Food, Natural Resource, and Engineering (DAFNE), via Napoli 25, I-71122, Foggia, Italy.
| |
Collapse
|
2
|
Sun Z, Qi M. End-modification of poly(ether-carbonate) copolymer by adamantane cages: An effective approach for improving the selectivity of gas chromatographic stationary phases. J Chromatogr A 2023; 1695:463940. [PMID: 36990034 DOI: 10.1016/j.chroma.2023.463940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/19/2023] [Accepted: 03/21/2023] [Indexed: 03/30/2023]
Abstract
This work reports the investigation of a new poly(propylene-carbonate) copolymer terminated by the adamantane cages (APPC) as the stationary phase for gas chromatographic (GC) analyses. In GC, the selectivity of a stationary phase is the key factor that governs the column separation performance for analytes, particularly those of high similarity in structures and properties. As such, we employed more than a dozen of isomer mixtures of separation difficulty for investigating the separation performance of the APPC column, involving the isomers of alkanes, alkylbenzenes, halobenzenes phenols and anilines. Meanwhile, the column coated with poly(propylene carbonate) diol (PPCD) differing from APPC only in their terminal groups and two commercial columns coated with polyethylene glycol (PEG) and polysiloxane, respectively, were used as the reference columns. The separation results evidenced the distinctly advantageous performance of the APPC column over the reference columns. Moreover, the APPC column showed excellent repeatability and reproducibility with the relative standard deviation (RSD) values over the range of 0.01%-0.04% for run-to-run, 0.15%-0.28% for day-to-day and 3.4%-3.9% for column-to-column (n = 4). Its application to GC-MS analysis of the verbena essential oil demonstrated its separation advantages for a wide range of components in practical samples. Up to date, the adamantyl-terminated poly(ether-carbonate) copolymers have not been reported in any fields. Its high-resolution performance demonstrates the feasibility of adamantyl-terminated block copolymers as highly selective stationary phases for GC analyses, which offers a vast room for fundamental researches and applications.
Collapse
Affiliation(s)
- Ziqi Sun
- Key Laboratory of Cluster Science, Ministry of Education of China, Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Meiling Qi
- Key Laboratory of Cluster Science, Ministry of Education of China, Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China.
| |
Collapse
|
3
|
He Y, Zheng B, Qi M, Huo L. High selectivity of a novel D–A structured copolymer as a gas chromatographic stationary phase toward aromatic isomers. NEW J CHEM 2022. [DOI: 10.1039/d2nj00724j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
This work reports a new π-conjugated copolymer with D–A structure (PBDB-T) as the stationary phase for gas chromatography (GC) with high resolving performance towards aromatic isomers of high similarity in structure and properties.
Collapse
Affiliation(s)
- Yongrui He
- Key Laboratory of Cluster Science, Ministry of Education of China, Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China
- School of Pharmacy, Weifang Medical University, Weifang, 261053, China
| | - Bing Zheng
- School of Chemistry Beihang University, Beijing, 100191, China
| | - Meiling Qi
- Key Laboratory of Cluster Science, Ministry of Education of China, Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Lijun Huo
- School of Chemistry Beihang University, Beijing, 100191, China
| |
Collapse
|