1
|
Li W, Ba M, Song Y, Zhang Y, Xu X, Liu H, Li L, Liu X, Cai Z, Sun T. High Selectivity of A Novel Pillar[5]arene with Ester Units as a Gas Chromatographic Stationary Phase toward Aromatic Isomers. Chem Biodivers 2024; 21:e202301795. [PMID: 38268034 DOI: 10.1002/cbdv.202301795] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Revised: 01/22/2024] [Accepted: 01/24/2024] [Indexed: 01/26/2024]
Abstract
This work reports the first example of employing ester-functionalized pillar[5]arene (P5A-C10-OAc) stationary phase for gas chromatography (GC) separations. The as-fabricated P5A-C10-OAc column achieved improved column efficiency of 4270 plates/m and separation performance in contrast to the P5-C10-Br column. The P5A-C10-OAc column showed good separation performance for a wide range of analytes such as alkanes, bromoalkanes, ketones, fatty acid methyl esters, aldehydes, alcohols, halobenzenes, anilines, phenols, naphthalenes, and showed sharp and symmetrical peak shapes for analytes that are liable to peak-tailing in GC analysis. As testified by the challenging isomer mixtures (bromonitrobenzene, chloronitrobenzene, bromobenzaldehyde, chlorobenzaldehyde, nitrobenzaldehyde), the P5A-C10-OAc column exhibited comprehensively higher separation capability than the P5A-C10-Br, P5A-C10 and commercial HP-35 columns. This work demonstrates the great potential of pillararene-based stationary phases as a new type of stationary phases for GC separations.
Collapse
Affiliation(s)
- Wen Li
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, P. R. China
| | - Mengyi Ba
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, P. R. China
| | - Yanli Song
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, P. R. China
| | - Yuanyuan Zhang
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, P. R. China
| | - Xiang Xu
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, P. R. China
| | - Haixin Liu
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, P. R. China
| | - Leyao Li
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, P. R. China
| | - Xinyi Liu
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, P. R. China
| | - Zhiqiang Cai
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, P. R. China
| | - Tao Sun
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, P. R. China
| |
Collapse
|
2
|
Sun Z, Qi M. End-modification of poly(ether-carbonate) copolymer by adamantane cages: An effective approach for improving the selectivity of gas chromatographic stationary phases. J Chromatogr A 2023; 1695:463940. [PMID: 36990034 DOI: 10.1016/j.chroma.2023.463940] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 03/19/2023] [Accepted: 03/21/2023] [Indexed: 03/30/2023]
Abstract
This work reports the investigation of a new poly(propylene-carbonate) copolymer terminated by the adamantane cages (APPC) as the stationary phase for gas chromatographic (GC) analyses. In GC, the selectivity of a stationary phase is the key factor that governs the column separation performance for analytes, particularly those of high similarity in structures and properties. As such, we employed more than a dozen of isomer mixtures of separation difficulty for investigating the separation performance of the APPC column, involving the isomers of alkanes, alkylbenzenes, halobenzenes phenols and anilines. Meanwhile, the column coated with poly(propylene carbonate) diol (PPCD) differing from APPC only in their terminal groups and two commercial columns coated with polyethylene glycol (PEG) and polysiloxane, respectively, were used as the reference columns. The separation results evidenced the distinctly advantageous performance of the APPC column over the reference columns. Moreover, the APPC column showed excellent repeatability and reproducibility with the relative standard deviation (RSD) values over the range of 0.01%-0.04% for run-to-run, 0.15%-0.28% for day-to-day and 3.4%-3.9% for column-to-column (n = 4). Its application to GC-MS analysis of the verbena essential oil demonstrated its separation advantages for a wide range of components in practical samples. Up to date, the adamantyl-terminated poly(ether-carbonate) copolymers have not been reported in any fields. Its high-resolution performance demonstrates the feasibility of adamantyl-terminated block copolymers as highly selective stationary phases for GC analyses, which offers a vast room for fundamental researches and applications.
Collapse
Affiliation(s)
- Ziqi Sun
- Key Laboratory of Cluster Science, Ministry of Education of China, Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Meiling Qi
- Key Laboratory of Cluster Science, Ministry of Education of China, Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China.
| |
Collapse
|