1
|
Jang D, Altern SH, Cramer SM. In silico mediated workflow for rapid development of downstream processing: Orthogonal product-related impurity removal for a Fc-containing therapeutic. J Chromatogr A 2024; 1735:465281. [PMID: 39243589 DOI: 10.1016/j.chroma.2024.465281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2024] [Revised: 08/15/2024] [Accepted: 08/16/2024] [Indexed: 09/09/2024]
Abstract
Therapeutic formats derived from the monoclonal antibody structure have been gaining significant traction in the biopharmaceutical market. Being structurally similar to mAbs, most Fc-containing therapeutics exhibit product-related impurities in the form of aggregates, charge variants, fragments, and glycoforms, which are inherently challenging to remove. In this work, we developed a workflow that employed rapid resin screening in conjunction with an in silico tool to identify and rank orthogonally selective processes for the removal of product-related impurities from a Fc-containing therapeutic product. Linear salt gradient screens were performed at various pH conditions on a set of ion-exchange, multimodal ion-exchange, and hydrophobic interaction resins. Select fractions from the screening experiments were analyzed by three different analytical techniques to characterize aggregates, charge variants, fragments, and glycoforms. The retention database generated by the resin screens and subsequent impurity characterization were then processed by an in silico tool that generated and ranked all possible two-step resin sequences for the removal of product-related impurities. A highly-ranked process was then evaluated and refined at the bench-scale to develop a completely flowthrough two-step polishing process which resulted in complete removal of the Man5 glycoform and aggregate impurities with a 73% overall yield. The successful implementation of the in silico mediated workflow suggests the possibility of a platformable workflow that could facilitate polishing process development for a wide variety of mAb-based therapeutics.
Collapse
Affiliation(s)
- Dongyoun Jang
- Department of Chemical and Biological Engineering and Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY, 12180, United States
| | - Scott H Altern
- Department of Chemical and Biological Engineering and Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY, 12180, United States
| | - Steven M Cramer
- Department of Chemical and Biological Engineering and Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY, 12180, United States.
| |
Collapse
|
2
|
Keulen D, Apostolidi M, Geldhof G, Le Bussy O, Pabst M, Ottens M. Comparing in silico flowsheet optimization strategies in biopharmaceutical downstream processes. Biotechnol Prog 2024:e3514. [PMID: 39425493 DOI: 10.1002/btpr.3514] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Revised: 08/25/2024] [Accepted: 10/02/2024] [Indexed: 10/21/2024]
Abstract
The challenging task of designing biopharmaceutical downstream processes is initially to select the type of unit operations, followed by optimizing their operating conditions. For complex flowsheet optimizations, the strategy becomes crucial in terms of duration and outcome. In this study, we compared three optimization strategies, namely, simultaneous, top-to-bottom, and superstructure decomposition. Moreover, all strategies were evaluated by either using chromatographic Mechanistic Models (MMs) or Artificial Neural Networks (ANNs). An overall evaluation of 39 flowsheets was performed, including a buffer-exchange step between the chromatography operations. All strategies identified orthogonal structures to be optimal, and the weighted overall performance values were generally consistent between the MMs and ANNs. In terms of time-efficiency, the decomposition method with MMs stands out when utilizing multiple cores on a multiprocessing system for simulations. This study analyses the influence of different optimization strategies on flowsheet optimization and advices on suitable strategies and modeling techniques for specific scenarios.
Collapse
Affiliation(s)
- Daphne Keulen
- Department of Biotechnology, Delft University of Technology, Delft, The Netherlands
| | - Myrto Apostolidi
- Department of Biotechnology, Delft University of Technology, Delft, The Netherlands
| | | | | | - Martin Pabst
- Department of Biotechnology, Delft University of Technology, Delft, The Netherlands
| | - Marcel Ottens
- Department of Biotechnology, Delft University of Technology, Delft, The Netherlands
| |
Collapse
|
3
|
Chen YC, Yao SJ, Lin DQ. Enhancing thermodynamic consistency: Clarification on the application of asymmetric activity model in multi-component chromatographic separation. J Chromatogr A 2024; 1731:465156. [PMID: 39047442 DOI: 10.1016/j.chroma.2024.465156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2024] [Revised: 07/06/2024] [Accepted: 07/08/2024] [Indexed: 07/27/2024]
Abstract
The single-component Mollerup model, with over 40 direct applications and 442 citations, is the most widely used activity model for chromatographic mechanistic modeling. Many researchers have extended this formula to multi-component systems by directly adding subscripts, a modification deemed thermodynamically inconsistent (referred to as the reference model). In this work, we rederived the asymmetric activity model for multi-component systems, using the van der Waals equation of state, and termed it the multi-component Mollerup model. In contrast to the reference model, our proposed model accounts for the contributions of all components to the activity. Three numerical experiments were performed to investigate the impact of the three different activity models on the chromatographic modeling. The results indicate that our proposed model represents a thermodynamically consistent generalization of the single-component Mollerup model to multi-component systems. This communication advocates adopting of the multi-component Mollerup model for activity modeling in multi-component chromatographic separation to enhance thermodynamic consistency.
Collapse
Affiliation(s)
- Yu-Cheng Chen
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China
| | - Shan-Jing Yao
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China
| | - Dong-Qiang Lin
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China.
| |
Collapse
|
4
|
Yang YX, Lin ZY, Chen YC, Yao SJ, Lin DQ. Modeling multi-component separation in hydrophobic interaction chromatography with improved parameter-by-parameter estimation method. J Chromatogr A 2024; 1730:465121. [PMID: 38959659 DOI: 10.1016/j.chroma.2024.465121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2024] [Revised: 06/10/2024] [Accepted: 06/24/2024] [Indexed: 07/05/2024]
Abstract
Mechanistic models are powerful tools for chromatographic process development and optimization. However, hydrophobic interaction chromatography (HIC) mechanistic models lack an effective and logical parameter estimation method, especially for multi-component system. In this study, a parameter-by-parameter method for multi-component system (called as mPbP-HIC) was derived based on the retention mechanism to estimate the six parameters of the Mollerup isotherm for HIC. The linear parameters (ks,i and keq,i) and nonlinear parameters (ni and qmax,i) of the isotherm can be estimated by the linear regression (LR) and the linear approximation (LA) steps, respectively. The remaining two parameters (kp,i and kkin,i) are obtained by the inverse method (IM). The proposed method was verified with a two-component model system. The results showed that the model could accurately predict the protein elution at a loading of 10 g/L. However, the elution curve fitting was unsatisfactory for high loadings (12 g/L and 14 g/L), which is mainly attributed to the demanding experimental conditions of the LA step and the potential large estimation error of the parameter qmax. Therefore, the inverse method was introduced to further calibrate the parameter qmax, thereby reducing the estimation error and improving the curve fitting. Moreover, the simplified linear approximation (SLA) was proposed by reasonable assumption, which provides the initial guess of qmax without solving any complex matrix and avoids the problem of matrix unsolvable. In the improved mPbP-HIC method, qmax would be initialized by the SLA and finally determined by the inverse method, and this strategy was named as SLA+IM. The experimental validation showed that the improved mPbP-HIC method has a better curve fitting, and the use of SLA+IM reduces the error accumulation effect. In process optimization, the parameters estimated by the improved mPbP-HIC method provided the model with excellent predictive ability and reasonable extrapolation. In conclusion, the SLA+IM strategy makes the improved mPbP-HIC method more rational and can be easily applied to the practical separation of protein mixture, which would accelerate the process development for HIC in downstream of biopharmaceuticals.
Collapse
Affiliation(s)
- Yu-Xiang Yang
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China
| | - Zhi-Yuan Lin
- Zhejiang University-University of Edinburgh Institute, Zhejiang University, Haining 314400, China
| | - Yu-Cheng Chen
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China
| | - Shan-Jing Yao
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China
| | - Dong-Qiang Lin
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China.
| |
Collapse
|
5
|
Ballweg T, Liu M, Grimm J, Sedghamiz E, Wenzel W, Franzreb M. All-atom modeling of methacrylate-based multi-modal chromatography resins for Langmuir constant prediction of peptides. J Chromatogr A 2024; 1730:465089. [PMID: 38879977 DOI: 10.1016/j.chroma.2024.465089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 06/11/2024] [Accepted: 06/12/2024] [Indexed: 06/18/2024]
Abstract
In downstream processing, the intricate nature of the interactions between biomolecules and adsorbent materials presents a significant challenge in the prediction of their binding and elution behaviors. This complexity is further heightened in multi-modal chromatography (MMC), which employs two distinct binding mechanisms. To gain a deeper understanding of the involved interactions, simulating the adsorption of biomolecules on resin surfaces is a focal point of ongoing research. However, previous studies often simplified the adsorbent surface, modeling it as a flat or slightly curved plane without including a realistic backbone structure. Here, we introduce and validate two novel workflows aimed at predicting peptide binding behaviors in MMC, specifically targeting methacrylate-based resins. Our first achievement was the development of an all-atom model of a commercial MMC resin surface, incorporating its polymethacrylic backbone. Furthermore, we established and tested a workflow for rapid calculations of binding free energies (ΔG) with 10 linear peptides as target molecules. These ΔG calculations were effectively used to predict Langmuir constants, achieving a high coefficient of determination (R²) of 0.96. In subsequent benchmarking tests, our model outperformed established, simpler resin surface models in terms of predictive capabilities.
Collapse
Affiliation(s)
- Tim Ballweg
- Institute of Functional Interfaces, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen 76344, Germany
| | - Modan Liu
- Institute of Functional Interfaces, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen 76344, Germany
| | - Julian Grimm
- Institute of Functional Interfaces, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen 76344, Germany
| | - Elaheh Sedghamiz
- Institute of Nanotechnology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen 76344, Germany; Schrödinger, GmbH, Glücksteinallee 25, Mannheim 68163, Germany
| | - Wolfgang Wenzel
- Institute of Nanotechnology, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen 76344, Germany
| | - Matthias Franzreb
- Institute of Functional Interfaces, Karlsruhe Institute of Technology, Hermann-von-Helmholtz-Platz 1, Eggenstein-Leopoldshafen 76344, Germany.
| |
Collapse
|
6
|
Lorek JK, Karkov HS, Matthiesen F, Dainiak M. High throughput screening for rapid and reliable prediction of monovalent antibody binding behavior in flowthrough mode. Biotechnol Bioeng 2024; 121:2332-2346. [PMID: 37926999 DOI: 10.1002/bit.28572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 09/11/2023] [Accepted: 09/21/2023] [Indexed: 11/07/2023]
Abstract
Flowthrough (FT) anion exchange (AEX) chromatography is a widely used polishing step for the purification of monoclonal antibody (mAb) formats. To accelerate downstream process development, high throughput screening (HTS) tools have proven useful. In this study, the binding behavior of six monovalent mAbs (mvAbs) was investigated by HTS in batch binding mode on different AEX and mixed-mode resins at process-relevant pH and NaCl concentrations. The HTS entailed the evaluation of mvAb partition coefficients (Kp) and visualization of results in surface-response models. Interestingly, the HTS data grouped the mvAbs into either a strong-binding group or a weak-binding/FT group independent of theoretical Isoelectric point. Mapping the charged and hydrophobic patches by in silico protein surface property analyses revealed that the distribution of patches play a major role in predicting FT behavior. Importantly, the conditions identified by HTS were successfully verified by 1 mL on-column experiments. Finally, employing the optimal FT conditions (7-9 mS/cm and pH 7.0) at a mini-pilot scale (CV = 259 mL) resulted in 99% yield and a 21-23-fold reduction of host cell protein to <100 ppm, depending on the varying host cell protein (HCP) levels in the load. This work opens the possibility of using HTS in FT mode to accelerate downstream process development for mvAb candidates in early research.
Collapse
Affiliation(s)
| | | | - Finn Matthiesen
- Purification Technologies, Novo Nordisk A/S, Maaloev, Denmark
| | - Maria Dainiak
- Purification Technologies, Novo Nordisk A/S, Maaloev, Denmark
| |
Collapse
|
7
|
Hess R, Faessler J, Yun D, Mama A, Saleh D, Grosch JH, Wang G, Schwab T, Hubbuch J. Predicting multimodal chromatography of therapeutic antibodies using multiscale modeling. J Chromatogr A 2024; 1718:464706. [PMID: 38335881 DOI: 10.1016/j.chroma.2024.464706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2023] [Revised: 01/30/2024] [Accepted: 01/31/2024] [Indexed: 02/12/2024]
Abstract
Multimodal chromatography has emerged as a powerful method for the purification of therapeutic antibodies. However, process development of this separation technique remains challenging because of an intricate and molecule-specific interaction towards multimodal ligands, leading to time-consuming and costly experimental optimization. This study presents a multiscale modeling approach to predict the multimodal chromatographic behavior of therapeutic antibodies based on their sequence information. Linear gradient elution (LGE) experiments were performed on an anionic multimodal resin for 59 full-length antibodies, including five different antibody formats at pH 5.0, 6.0, and 7.0 that were used for parameter determination of a linear adsorption model at low loading density conditions. Quantitative structure-property relationship (QSPR) modeling was utilized to correlate the adsorption parameters with up to 1374 global and local physicochemical descriptors calculated from antibody homology models. The final QSPR models employed less than eight descriptors per model and demonstrated high training accuracy (R² > 0.93) and reasonable test set prediction accuracy (Q² > 0.83) for the adsorption parameters. Model evaluation revealed the significance of electrostatic interaction and hydrophobicity in determining the chromatographic behavior of antibodies, as well as the importance of the HFR3 region in antibody binding to the multimodal resin. Chromatographic simulations using the predicted adsorption parameters showed good agreement with the experimental data for the vast majority of antibodies not employed during the model training. The results of this study demonstrate the potential of sequence-based prediction for determining chromatographic behavior in therapeutic antibody purification. This approach leads to more efficient and cost-effective process development, providing a valuable tool for the biopharmaceutical industry.
Collapse
Affiliation(s)
- Rudger Hess
- Karlsruhe Institute of Technology (KIT), Institute of Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe, Germany; DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Jan Faessler
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Doil Yun
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Ahmed Mama
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - David Saleh
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Jan-Hendrik Grosch
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Gang Wang
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Thomas Schwab
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Jürgen Hubbuch
- Karlsruhe Institute of Technology (KIT), Institute of Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe, Germany.
| |
Collapse
|
8
|
Yang YX, Chen YC, Yao SJ, Lin DQ. Parameter-by-parameter estimation method for adsorption isotherm in hydrophobic interaction chromatography. J Chromatogr A 2024; 1716:464638. [PMID: 38219627 DOI: 10.1016/j.chroma.2024.464638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 01/06/2024] [Accepted: 01/08/2024] [Indexed: 01/16/2024]
Abstract
Hydrophobic interaction chromatography (HIC) is used as a critical polishing step in the downstream processing of biopharmaceuticals. Normally the process development of HIC is a cumbersome and time-consuming task, and the mechanical models can provide a powerful tool to characterize the process, assist process design and accelerate process development. However, the current estimation of model parameters relies on the inverse method, which lacks an efficient and logical parameter estimation strategy. In this study, a parameter-by-parameter (PbP) method based on the theoretical derivation and simplifying assumptions was proposed to estimate the Mollerup isotherm parameters for HIC. The method involves three key steps: (1) linear regression (LR) to estimate the salt-protein interaction parameter and the equilibrium constant; (2) linear approximation (LA) to estimate the stoichiometric parameter and the maximum binding capacity; and (3) inverse method to estimate the protein-protein interaction parameter and the kinetic coefficient. The results indicated that the LR step should be used for dilution condition (loading factor below 5%), while the LA step should be conducted when the isotherm is in the transition or nonlinear regions. Six numerical experiments were conducted to implement the PbP method. The results demonstrated that the PbP method developed allows for the systematic estimation of HIC parameters one-by-one, effectively reducing the number of parameters required for inverse method estimation from six to two. This helps prevent non-identifiability of structural parameters. The feasibility of the PbP-HIC method was further validated by real-world experiments. Moreover, the PbP method enhances the mechanistic understanding of adsorption behavior of HIC and shows a promising application to other stoichiometric displacement model-derived isotherms.
Collapse
Affiliation(s)
- Yu-Xiang Yang
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China
| | - Yu-Cheng Chen
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China
| | - Shan-Jing Yao
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China
| | - Dong-Qiang Lin
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Zhejiang Key Laboratory of Smart Biomaterials, College of Chemical and Biological Engineering, Zhejiang University, Hangzhou 310058, China.
| |
Collapse
|
9
|
Hess R, Faessler J, Yun D, Saleh D, Grosch JH, Schwab T, Hubbuch J. Antibody sequence-based prediction of pH gradient elution in multimodal chromatography. J Chromatogr A 2023; 1711:464437. [PMID: 37865026 DOI: 10.1016/j.chroma.2023.464437] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 10/03/2023] [Accepted: 10/05/2023] [Indexed: 10/23/2023]
Abstract
Multimodal chromatography has emerged as a promising technique for antibody purification, owing to its capacity to selectively capture and separate target molecules. However, the optimization of chromatography parameters remains a challenge due to the intricate nature of protein-ligand interactions. To tackle this issue, efficient predictive tools are essential for the development and optimization of multimodal chromatography processes. In this study, we introduce a methodology that predicts the elution behavior of antibodies in multimodal chromatography based on their amino acid sequences. We analyzed a total of 64 full-length antibodies, including IgG1, IgG4, and IgG-like multispecific formats, which were eluted using linear pH gradients from pH 9.0 to 4.0 on the anionic mixed-mode resin Capto adhere. Homology models were constructed, and 1312 antibody-specific physicochemical descriptors were calculated for each molecule. Our analysis identified six key structural features of the multimodal antibody interaction, which were correlated with the elution behavior, emphasizing the antibody variable region. The results show that our methodology can predict pH gradient elution for a diverse range of antibodies and antibody formats, with a test set R² of 0.898. The developed model can inform process development by predicting initial conditions for multimodal elution, thereby reducing trial and error during process optimization. Furthermore, the model holds the potential to enable an in silico manufacturability assessment by screening target antibodies that adhere to standardized purification conditions. In conclusion, this study highlights the feasibility of using structure-based prediction to enhance antibody purification in the biopharmaceutical industry. This approach can lead to more efficient and cost-effective process development while increasing process understanding.
Collapse
Affiliation(s)
- Rudger Hess
- Institute of Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany; DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Jan Faessler
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Doil Yun
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - David Saleh
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Jan-Hendrik Grosch
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Thomas Schwab
- DSP Development, Boehringer Ingelheim Pharma GmbH & Co. KG, Biberach, Germany
| | - Jürgen Hubbuch
- Institute of Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany.
| |
Collapse
|
10
|
Altern SH, Welsh JP, Lyall JY, Kocot AJ, Burgess S, Kumar V, Williams C, Lenhoff AM, Cramer SM. Isotherm model discrimination for multimodal chromatography using mechanistic models derived from high-throughput batch isotherm data. J Chromatogr A 2023; 1693:463878. [PMID: 36827799 DOI: 10.1016/j.chroma.2023.463878] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2022] [Revised: 02/05/2023] [Accepted: 02/15/2023] [Indexed: 02/19/2023]
Abstract
In this work, we have examined an array of isotherm formalisms and characterized them based on their relative complexities and predictive abilities with multimodal chromatography. The set of isotherm models studied were all based on the stoichiometric displacement framework, with considerations for electrostatic interactions, hydrophobic interactions, and thermodynamic activities. Isotherm parameters for each model were first determined through twenty repeated fits to a set of mAb - Capto MMC batch isotherm data spanning a range of loading, ionic strength, and pH as well as a set of mAb - Capto Adhere batch data at constant pH. The batch isotherm data were used in two ways-spanning the full range of loading or consisting of only the high concentration data points. Predictive ability was defined through the model's capacity to capture prominent changes in salt gradient elution behavior with respect to pH for Capto MMC or unique elution patterns and yield losses with respect to gradient slope for Capto Adhere. In both cases, model performance was quantified using a scoring metric based on agreement in peak characteristics for column predictions and accuracy of fit for the batch data. These scores were evaluated for all twenty isotherm fits and their corresponding column predictions, thereby producing a statistical distribution of model performances. Model complexity (number of isotherm parameters) was then considered through use of the Akaike information criterion (AIC) calculated from the score distributions. While model performance for Capto MMC benefitted substantially from removal of low protein concentration data, this was not the case for Capto Adhere; this difference was likely due to the qualitatively different shapes of the isotherms between the two resins. Surprisingly, the top-performing (high accuracy with minimal number of parameters) isotherm model was the same for both resins. The extended steric mass action (SMA) isotherm (containing both protein-salt and protein-protein activity terms) accurately captured both the pH-dependent elution behavior for Capto MMC as well as loss in protein recovery with increasing gradient slope for Capto Adhere. In addition, this isotherm model achieved the highest median score in both resin systems, despite it lacking any explicit hydrophobic stoichiometric terms. The more complex isotherm models, which explicitly accounted for both electrostatic and hydrophobic interaction stoichiometries, were ill-suited for Capto MMC and had lower AIC model likelihoods for Capto Adhere due to their increased complexity. Interestingly, the ability of the extended SMA isotherm to predict the Capto Adhere results was largely due to the protein-salt activity coefficient, as determined via isotherm parameter sensitivity analyses. Further, parametric studies on this parameter demonstrated that it had a major impact on both binding affinity and elution behavior, therein fully capturing the impact of hydrophobic interactions. In summary, we were able to determine the isotherm formalisms most capable of consistently predicting a wide range of column behavior for both a multimodal cation-exchange and multimodal anion-exchange resin with high accuracy, while containing a minimized set of model parameters.
Collapse
Affiliation(s)
- Scott H Altern
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA
| | - John P Welsh
- Biologics Process Research and Development, Merck & Co., Inc., Rahway, NJ, USA
| | - Jessica Y Lyall
- Purification Development, Genentech, South San Francisco, CA, USA
| | - Andrew J Kocot
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA
| | - Sean Burgess
- Purification Development, Genentech, South San Francisco, CA, USA
| | - Vijesh Kumar
- Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, DE, USA
| | - Chris Williams
- Purification Development, Genentech, South San Francisco, CA, USA
| | - Abraham M Lenhoff
- Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, DE, USA
| | - Steven M Cramer
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, NY, USA.
| |
Collapse
|