1
|
Morgan PB, Sulley AL. Challenges to the new soft contact lens wearer and strategies for clinical management. Cont Lens Anterior Eye 2023; 46:101827. [PMID: 36935225 DOI: 10.1016/j.clae.2023.101827] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 01/10/2023] [Accepted: 03/05/2023] [Indexed: 03/19/2023]
Abstract
Soft contact lens discontinuations have a dramatic impact on the overall success of this form of vision correction, and evidence suggests that the reasons for contact lens cessation are different for new wearers than for established lens users. In descending order, these relate to vision, discomfort, handling, inconvenience/loss of interest, ocular health and cost. This paper considers the background and underlying evidence for these causes of soft lens discontinuation in new wearers, and presents clinical management strategies to minimise this phenomenon. Such measures can reasonably be expected to significantly reduce the number of contact lens discontinuations leading to happier patients, increased satisfaction for eye care professionals (ECPs), and greater success for both individual practices and the contact lens industry more broadly.
Collapse
Affiliation(s)
- Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, Manchester M13 9PL, England.
| | | |
Collapse
|
2
|
Vianya-Estopa M, Nagra M, Cochrane A, Retallic N, Dunning D, Terry L, Lloyd A, Wolffsohn JS, Alderson A, Mouat G, McDonnell C, Murphy O, Huntjens B, Mayhem M, Martin E, Sweeney L, Evans K, Naroo S, Conway R, Simo L, Maldonado-Codina C, Mallon C, Underwood J, Trivedy K, Joshi M. Optimising subjective anterior eye grading precision. Cont Lens Anterior Eye 2020; 43:489-492. [DOI: 10.1016/j.clae.2020.03.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Revised: 03/11/2020] [Accepted: 03/11/2020] [Indexed: 10/24/2022]
|
3
|
Chen Q, Jiang H, Wang J. Conjunctival Vascular Adaptation Related to Ocular Comfort in Habitual Contact Lens Wearers. Am J Ophthalmol 2020; 216:99-109. [PMID: 32247776 DOI: 10.1016/j.ajo.2020.03.031] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2019] [Revised: 03/20/2020] [Accepted: 03/20/2020] [Indexed: 01/12/2023]
Abstract
PURPOSE We sought to investigate the bulbar conjunctival vascular responses in habitual contact lens (HCL) and non-contact lens (NCL) wearers after short-term lens wear and their relationships with ocular comfort. DESIGN A prospective, comparative before-and-after study. METHODS Twenty-seven subjects (13 HCL and 14 NCL wearers) were enrolled. Microvasculature and microcirculation on the temporal bulbar conjunctiva were imaged at baseline and 0.5 and 6 hours after wearing contact lenses (1-Day Acuvue TruEye; base curve, 8.5 mm; power, -0.50 diopters) on both eyes. The measurements included vessel diameter (D), axial (VA), and cross-sectional (VS) blood flow velocities, blood flow volume (Q), and vessel density (Dbox) and complexity (D0). A Contact Lens User Experience (CLUE) questionnaire was used to assess ocular comfort. RESULTS No significant change (P > .05) was observed in D, VA, VS, Q, Dbox, and D0 in the HCL wearers after contact lens wear. By contrast, VA, VS, Q, Dbox, and D0 increased significantly after lens wear (after 0.5 and 6 hours) in NCL wearers compared with baseline (P < .05). Moreover, the changes from the baseline to 0.5 hours (VA, VS, and Dbox) and 6 hours (VA, VS, Q, Dbox, and D0) after contact lens wear in NCL wearers were significantly greater than that in HCL wearers (P < .05). The CLUE score 6 hours after lens wear was higher in HCL wearers than in NCL wearers (P < .05). It was also significantly correlated with VA, VS, and D0 after 6-hour lens wear in HCL wearers (P < .05). CONCLUSIONS This is the first study to reveal the relationship between ocular comfort and conjunctival vascular responses in habitual contact lens wearers.
Collapse
Affiliation(s)
- Qi Chen
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China; Bascom Palmer Eye Institute, University of Miami, Miami, Florida, USA
| | - Hong Jiang
- Bascom Palmer Eye Institute, University of Miami, Miami, Florida, USA
| | - Jianhua Wang
- Bascom Palmer Eye Institute, University of Miami, Miami, Florida, USA.
| |
Collapse
|
4
|
Read ML, Navascues-Cornago M, Keir N, Maldonado-Codina C, Morgan PB. The impact of contact lens wear on ocular surface mucins using a novel clinical fluorescence imaging system. Cont Lens Anterior Eye 2019; 43:378-388. [PMID: 31451311 DOI: 10.1016/j.clae.2019.08.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 08/14/2019] [Accepted: 08/15/2019] [Indexed: 10/26/2022]
Abstract
PURPOSE Fluorescein-labelled wheat germ agglutinin (F-WGA) acts as a marker for ocular surface mucins. This clinical study sought to investigate whether the degree of F-WGA fluorescence observed at the ocular surface differed between symptomatic contact lens wearers, asymptomatic contact lens wearers and non-contact lens wearers, using a novel imaging system. METHODS Twenty-five participants (10 symptomatic contact lens wearers, 10 asymptomatic contact lens wearers and 5 non-contact lens wearers) attended a single study visit. Photographs of the cornea, bulbar and tarsal conjunctiva were captured following application of F-WGA solution. RESULTS The imaging system captured high-resolution images of F-WGA fluorescence at the ocular surface. The degree of fluorescence differed between the ocular surface regions (p < 0.001). A significant difference in fluorescence was observed between participant groups for the cornea (p = 0.01), with both the symptomatic and asymptomatic contact lens wearers showing lower fluorescence than the non-lens wearers. F-WGA associated fluorescence appeared diminished in the lid wiper region of the symptomatic lens wearers, compared to the asymptomatic group (p = 0.025). CONCLUSION The use of F-WGA as a clinical marker for ocular surface mucins allows an improved understanding of their distribution across the ocular surface. Contact lens wear appears to negatively impact mucin density across the ocular surface, with the most marked effect on the cornea. F-WGA fluorescence appeared diminished in the lid wiper region for the symptomatic contact lens wearing group, indicating that mechanical interaction in this region may play a role in the aetiology of contact lens discomfort. Given the ability of F-WGA to disclose mucin distribution across the ocular surface it is likely to be a key clinical tool in furthering our understanding of (i) the aetiology of contact lens related discomfort, (ii) contact lens designs/materials to minimise interaction with the ocular surface and (iii) dry eye disease and other ocular surface diseases.
Collapse
Affiliation(s)
- Michael L Read
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, United Kingdom.
| | - Maria Navascues-Cornago
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, United Kingdom.
| | - Nancy Keir
- CooperVision Inc., 6150 Stoneridge Mall Rd, Pleasanton, CA 94588, USA.
| | - Carole Maldonado-Codina
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, United Kingdom.
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester M13 9PL, United Kingdom.
| |
Collapse
|
5
|
Brygoła R, Sęk S, Sokołowski M, Kowalczyk-Hernández M, Pniewski J. Limits in measurements of contact lens surface profile using atomic force microscopy. Colloids Surf B Biointerfaces 2018; 165:229-234. [DOI: 10.1016/j.colsurfb.2018.02.018] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 11/17/2017] [Accepted: 02/10/2018] [Indexed: 11/25/2022]
|
6
|
Badugu R, Jeng BH, Reece EA, Lakowicz JR. Contact lens to measure individual ion concentrations in tears and applications to dry eye disease. Anal Biochem 2017; 542:84-94. [PMID: 29183834 DOI: 10.1016/j.ab.2017.11.014] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2017] [Revised: 10/24/2017] [Accepted: 11/18/2017] [Indexed: 11/18/2022]
Abstract
Dry eye disease (DED) affects millions of individuals in the United States and worldwide, and the incidence is increasing with an aging population. There is widespread agreement that the measurement of total tear osmolarity is the most reliable test, but this procedure provides only the total ionic strength and does not provide the concentration of each ionic species in tears. Here, we describe an approach to determine the individual ion concentrations in tears using modern silicone hydrogel (SiHG) contact lenses. We made pH (or H3O+, hydronium cation,/OH-, hydroxyl ion) and chloride ion (two of the important electrolytes in tear fluid) sensitive SiHG contact lenses. We attached hydrophobic C18 chains to water-soluble fluorescent probes for pH and chloride. The resulting hydrophobic ion sensitive fluorophores (H-ISF) bind strongly to SiHG lenses and could not be washed out with aqueous solutions. Both H-ISFs provide measurements which are independent of total intensity by use of wavelength-ratiometric measurements for pH or lifetime-based sensing for chloride. Our approach can be extended to fabricate a contact lens which provides measurements of the six dominant ionic species in tears. This capability will be valuable for research into the biochemical processes causing DED, which may improve the ability to diagnose the various types of DED.
Collapse
Affiliation(s)
- Ramachandram Badugu
- Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology, University of Maryland School of Medicine, 725 W. Lombard Street, Baltimore, MD 21201, USA.
| | - Bennie H Jeng
- Department of Ophthalmology and Visual Sciences, University of Maryland School of Medicine, 419 W. Redwood Street, Suite 420, Baltimore, MD 21201, USA
| | - E Albert Reece
- Department of Obstetrics, Gynecology and Reproductive Sciences, University of Maryland School of Medicine, 655 W. Baltimore Street, Baltimore, MD 21201, USA; Department of Biochemistry & Molecular Biology, University of Maryland School of Medicine, 655 W. Baltimore Street, Baltimore, MD 21201, USA
| | - Joseph R Lakowicz
- Center for Fluorescence Spectroscopy, Department of Biochemistry and Molecular Biology, University of Maryland School of Medicine, 725 W. Lombard Street, Baltimore, MD 21201, USA
| |
Collapse
|
7
|
Tam NK, Pitt WG, Perez KX, Handly E, Glenn AA, Hickey JW, Larsen BG. The role of multi-purpose solutions in prevention and removal of lipid depositions on contact lenses. Cont Lens Anterior Eye 2014; 37:405-14. [DOI: 10.1016/j.clae.2014.07.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2013] [Revised: 06/20/2014] [Accepted: 07/06/2014] [Indexed: 11/24/2022]
|
8
|
Abstract
OBJECTIVE To compare the short-term clinical performance of two dual-disinfectant multipurpose disinfecting solutions (MPDS) when used in conjunction with two silicone hydrogel contact lenses. METHODS Participants wore galyfilcon A and balafilcon A lenses, randomly allocated one type to each eye. Multipurpose disinfecting solutions were double-masked and allocated using a randomized crossover design. Lenses were presoaked overnight in the allocated MPDS, containing either polyquaternium-1/alexidine dihydrochloride (PQ-alexidine) or polyquaternium-1/myristamidopropyl dimethylamine (PQ-MAPDA). Lenses were worn daily for 4 days and disinfected with the same MPDS in which they had been soaked. Clinical assessments occurred immediately after insertion, 2 hours after insertion, and after 2 hours of wear on day 4. Subjective ratings were collected at each assessment and after 6 hours of wear on days 1 to 3. Linear mixed models were used for statistical analysis. RESULTS Solution-induced corneal staining (SICS) incidence was significantly different between MPDS lens combinations (P=0.01) with PQ-MAPDA-balafilcon A showing the highest incidence (27.8%). The incidence of SICS was significantly higher when balafilcon A lenses were worn compared with galyfilcon A (19.4% vs. 2.8%; P=0.04). There was no significant difference in SICS incidence between MPDS (PQ-alexidine=5.6%, PQ-MAPDA=16.7%; P=0.08). Polyquaternium-1/alexidine dihydrochloride was associated with significantly fewer symptoms of burning/stinging (9.7±0.6 vs. 9.1±2.2; P=0.03) and self-assessed redness (9.8±0.5 vs. 9.2±1.9; P=0.03) on initial lens insertion. There were no significant differences between MPDS for comfort ratings (P>0.05). CONCLUSION These short-term clinical results provide an initial indication that PQ-alexidine is associated with fewer symptoms on insertion but no significant difference in ocular comfort compared with PQ-MAPDA. Longer studies are required to provide further evidence.
Collapse
|
9
|
|
10
|
|
11
|
Morphology of contact lens-induced conjunctival epithelial flaps: a pilot study. Cont Lens Anterior Eye 2012; 35:185-8. [PMID: 22503643 DOI: 10.1016/j.clae.2012.03.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2011] [Revised: 03/15/2012] [Accepted: 03/19/2012] [Indexed: 11/22/2022]
Abstract
PURPOSE Conjunctival epithelial flap (CEF) is a conjunctival condition most commonly seen in silicone hydrogel contact lens wearers. This study utilized impression cytology to investigate the cellular composition and health of CEFs. METHODS Nine (9) subjects were enrolled - 3 non-lens wearers, 3 contact lens wearers without CEF, and 3 contact lens wearers with CEFs wearing 8.4/13.8 lotrafilcon A lenses. Impression cytology samples were collected from the flap or similar locations, if CEF was absent, using rectangular 5 mm × 2 mm Millipore HAWP02500 membrane filters. The filters were gently pressed onto the conjunctiva, subsequently fixed in 95% alcohol, stained with hematoxylin-eosin and evaluated under an Olympus IX70 microscope. Measurements of the longest cell and nucleus dimensions were measured on 40 cells from each filter by utilizing NIH Image 1.63. RESULTS CEF consisted of multilayers of epithelial and goblet cells and were devoid of inflammatory cells, basement membrane material and stromal tissue. The cytoplasmic and nuclear dimensions were similar within the groups and the cytoplasm-to-nucleus ratio was not different between the flap group and the non-lens wearing group. CONCLUSION The CEF appeared to be formed by healthy epithelial and goblet cells that have been dislocated from their normal location along the conjunctival surface by the lens edge. No inflammatory cells were present in this contact lens induced condition, which is reported to be associated most commonly with the silicone hydrogel material.
Collapse
|
12
|
Read ML, Morgan PB, Kelly JM, Maldonado-Codina C. Dynamic Contact Angle Analysis of Silicone Hydrogel Contact Lenses. J Biomater Appl 2010; 26:85-99. [DOI: 10.1177/0885328210363505] [Citation(s) in RCA: 54] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Contact angle measurements are used to infer the clinical wetting characteristics of contact lenses. Such characterization has become more commonplace since the introduction of silicone hydrogel contact lens materials, which have been associated with reduced in vivo wetting due to the inclusion of siloxane-containing components. Using consistent methodology and a single investigator, advancing and receding contact angles were measured for 11 commercially available silicone hydrogel contact lens types with a dynamic captive bubble technique employing customized, fully automated image analysis. Advancing contact angles were found to range between 20° and 72° with the lenses falling into six statistically discrete groupings. Receding contact angles fell within a narrower range, between 17° and 22°, with the lenses segregated into three groups. The relationship between these laboratory measurements and the clinical performance of the lenses requires further investigation.
Collapse
Affiliation(s)
- Michael Leonard Read
- Eurolens Research, Faculty of Life Sciences, The University of Manchester, Manchester, UK
| | - Philip Bruce Morgan
- Eurolens Research, Faculty of Life Sciences, The University of Manchester, Manchester, UK
| | - Jeremiah Michael Kelly
- Eurolens Research, Faculty of Life Sciences, The University of Manchester, Manchester, UK
| | | |
Collapse
|
13
|
|
14
|
Santodomingo-Rubido J, Barrado-Navascués E, Rubido-Crespo MJ, Sugimoto K, Sawano T. Compatibility of two new silicone hydrogel contact lenses with three soft contact lens multipurpose solutions. Ophthalmic Physiol Opt 2008; 28:373-81. [DOI: 10.1111/j.1475-1313.2008.00573.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
15
|
The Clinical Investigation of the Base Curve and Comfort Rate of a New Prototype Silicone Hydrogel Contact Lens. Eye Contact Lens 2008; 34:146-50. [DOI: 10.1097/icl.0b013e3181506bbd] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|