Mechó-García M, Arcas-Carbonell M, Orduna-Hospital E, Sánchez-Cano A, González-Méijome JM. The Influence of Accommodative Demand on Ocular Aberrations: A Study of Zernike Coefficients Repeatability and Variability. Curr Eye Res 2024:1-10. [PMID: 39004896 DOI: 10.1080/02713683.2024.2378009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 07/03/2024] [Indexed: 07/16/2024]
Abstract
PURPOSE To evaluate the repeatability of the Zernike coefficients in healthy eyes when monocular accommodation was stimulated at different vergences demands. METHODS A total of 36 right eyes from healthy volunteers were prospectively and consecutively recruited for this study. Wavefront aberrometry was conducted to objectively characterize the ocular optical quality during accommodation, from the individual's far point to a 5 D accommodation demand in steps of 0.5 D. The repeatability of Zernike coefficients up to the fourth order was assessed by calculating the within-eye repeatability (Sw), the coefficient of repeatability (CR), the coefficient of variation (CV), and the intraclass correlation coefficient (ICC) as an indicator of measurement reliability. RESULTS Correlation among repeated measurements showed high reliability (ICC > 0.513) for all parameters measured except some fourth-order Zernike coefficients, C(4, -4) (ICC < 0.766), C(4, -2) (ICC < 0.875), C(4, 2) (ICC < 0.778) and C(4, 4) (ICC < 0.811). Greater repeatability and less variability were obtained for high-order Zernike coefficients (CR < 0.154), although an increase in CR in the coefficients analyzed was observed with increasing accommodative demand. No clear trend was evident in CV; however, it was observed that the low-order Zernike coefficients exhibit lower CV (CV < 1.93) compared to the high-order Zernike coefficients (CV > 0). CONCLUSIONS The reliability of Zernike coefficients up to the fourth order in healthy young individuals demonstrated a strong consistency in measuring terms up to the fourth order, with more variability observed for high-order terms. The Zernike coefficients up to the third order exhibited the highest level of repeatability.
Collapse
Affiliation(s)
- María Mechó-García
- Clinical & Experimental Optometry Research Lab, Physics Center of Minho, and Porto Universities (CF-UM-UP), School of Sciences, University of Minho, Braga, Portugal
| | - María Arcas-Carbonell
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, España
- Aragon Health Research Institute (IIS Aragon), Zaragoza, Aragon, Spain
| | - Elvira Orduna-Hospital
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, España
- Aragon Health Research Institute (IIS Aragon), Zaragoza, Aragon, Spain
| | - Ana Sánchez-Cano
- Departamento de Física Aplicada, Universidad de Zaragoza, Zaragoza, España
- Aragon Health Research Institute (IIS Aragon), Zaragoza, Aragon, Spain
| | - José Manuel González-Méijome
- Clinical & Experimental Optometry Research Lab, Physics Center of Minho, and Porto Universities (CF-UM-UP), School of Sciences, University of Minho, Braga, Portugal
| |
Collapse
|
2
|
Rae SM, Price HC. The effect of soft contact lens wear and time from blink on wavefront aberration measurement variation. Clin Exp Optom 2021; 92:274-82. [DOI: 10.1111/j.1444-0938.2009.00377.x] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Affiliation(s)
- Sheila M Rae
- Vision and Eye Research Unit, Anglia Ruskin University, Cambridge, United Kingdom
E‐mail:
| | - Holly C Price
- Vision and Eye Research Unit, Anglia Ruskin University, Cambridge, United Kingdom
E‐mail:
| |
Collapse
|
3
|
Impact of Defocus and High-Order Aberrations on Light Disturbance Measurements. J Ophthalmol 2019; 2019:2874036. [PMID: 30719337 PMCID: PMC6334342 DOI: 10.1155/2019/2874036] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 09/28/2018] [Accepted: 12/09/2018] [Indexed: 11/23/2022] Open
Abstract
Purpose To evaluate the impact of different levels of positive and negative defocus on light disturbance (LD) measures and to understand how high-order aberrations (HOAs) and topographic quality parameters may influence the perception of photic phenomena. Methods Thirty young healthy subjects (21 females and 9 males) attended this cross-sectional study. LD was evaluated with the light distortion analyzer (LDA) in natural accommodative and cycloplegic conditions with positive and negative induced defocus of 1.00D. HOAs were taken for a natural mesopic (without cycloplegia) and for fixed 5 mm (with cycloplegia) pupil size. The impact of corneal morphological parameters (SAI, SRI, and Q-value) in LD was also investigated. Results Positive and negative induced defocus of 1.00D significantly increased the size of LD (p < 0.010, Wilcoxon signed rank test) but not its irregularity index. Spherical-like HOAs were associated with the size of LD, while coma-like and total-like HOAs were associated with LD irregularity. Our results showed that SRI was significantly correlated with the size of the disturbance area (r=0.519, p=0.003, Spearman correlation) and SAI with both size (r=0.502, p=0.005, Spearman correlation) and irregularity (r=0.371, p=0.044, Spearman correlation). However, no correlation between the Q-value and LD parameters was found. Conclusions The uncorrected positive and negative refractive errors might increase the size of the LD, such as the spherical-like HOAs, SAI, and SRI, instead of asphericity. Coma-like and total-like HOAs and SAI may influence the perception of irregularities in the LD shape. These results might have an impact on postrefractive surgery visual performance that should be investigated.
Collapse
|
4
|
Porcar E, Montalt JC, España-Gregori E, Peris-Martínez C. Corneo-scleral contact lenses in an uncommon case of keratoconus with high hyperopia and astigmatism. Cont Lens Anterior Eye 2017; 40:351-356. [PMID: 28712891 DOI: 10.1016/j.clae.2017.07.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2017] [Revised: 06/20/2017] [Accepted: 07/07/2017] [Indexed: 11/30/2022]
Abstract
PURPOSE To analyse the visual quality achieved by fitting corneo-scleral contact lenses (CScL) in an uncommon case of bilateral keratoconus, high hyperopia and astigmatism. METHODS A 45-year-old man presented for eye examination due to the unsatisfactory quality of his vision wearing soft toric contact lenses. He presented high hyperopia and astigmatism with bilateral keratoconus. He was fitted with CScL to correct his irregular astigmatism and ocular aberrations. A diagnostic trial set was used in the fitting process and he was assessed according to standardised fitting methodology. Visual acuity, corneal topography, biometry and ocular aberrations were evaluated. The follow-up period was 1year. RESULTS The best spectacle-corrected visual acuity was 20/32 with +8.00/-4.50×30° for the right eye (RE) and 20/25 with +7.75/-2.25×120° for the left eye (LE). After CScL fitting, visual acuity was improved to 20/20 and 20/16 for the RE and LE, respectively. The patient wore these contact lenses an average of 13h a day. The total high order aberrations decreased by approximately 79% in the RE (2.37-0.50μm) and 47% in the LE (1.04-0.55μm) after CScL fitting. Visual quality and wearing time were maintained after 1year wearing CScL. In addition, no adverse ocular effects were found during this period. CONCLUSION The present case report describes how the patient had CScL fitted successfully for management of keratoconus with high hyperopia and astigmatism. They provided optimal visual quality, along with prolonged use times and no adverse effects to the cornea.
Collapse
Affiliation(s)
- Esteban Porcar
- Department of Optics, Optometry and Vision Sciences, Physics College, University of Valencia, Burjassot, Valencia 46100, Spain.
| | - Juan Carlos Montalt
- Department of Optics, Optometry and Vision Sciences, Physics College, University of Valencia, Burjassot, Valencia 46100, Spain
| | - Enrique España-Gregori
- Department of Surgery, Ophthalmology Unit, la Fe University and Polytechnic Hospital, Faculty of Medicine and Odontology, University of Valencia, Hospital la Fe, Valencia 46026, Spain
| | - Cristina Peris-Martínez
- FISABIO Oftalmología Médica (FOM), Cornea Unit and Anterior Segment Diseases, Catholic University of Valencia, Valencia 46015, Spain
| |
Collapse
|
5
|
Porcar E, Montalt JC, España-Gregori E, Peris-Martínez C. Corneo-scleral contact lens in a piggyback system for keratoconus: A case report. Cont Lens Anterior Eye 2017; 40:190-194. [PMID: 28073689 DOI: 10.1016/j.clae.2016.12.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2016] [Revised: 12/12/2016] [Accepted: 12/21/2016] [Indexed: 11/28/2022]
Abstract
PURPOSE We describe a case of fitting a corneo-scleral contact lens with a multi-aspheric geometry design (MAGD CScL) on top of a daily silicone hydrogel lens (piggyback system) for keratoconus management. METHODS A 48-year-old man using soft toric contact lenses required an improvement in the unsatisfactory quality of his vision. He presented with bilateral asymmetric keratoconus with high myopia in the right eye (RE) and severe myopia in the left eye (LE). In addition, he had low vision in his LE because of a maculopathy. He was fitted with MAGD CScL to correct his irregular astigmatism. A diagnostic trial set was used in the fitting process and the patient was assessed according to a standardised fitting methodology. Visual acuity, corneal topography and contrast sensitivity were evaluated. The follow-up period was 1year. RESULTS The best spectacle-corrected visual acuity was 0.5 logMAR for the RE with -10 D/-5 D×60° and 2 logMAR for the LE with -20 D/-3 D×105°. After fitting MAGD CScL, visual acuity improved significantly to 0.1 logMAR for the RE and 1.3 logMAR for the LE, as well as contrast sensitivity. The fitting parameters of the base curve, diameter, and power were 7.05mm, 12.60mm, -18.50 D and 7.15mm, 12.60mm, -19 D for the RE and LE, respectively. Optimal fitting characteristics were found in terms of lens position and lens movement. To increase the time of MAGD CScL wear, they piggybacked on daily silicone hydrogel lenses of low power (-0.5 D). The patient reported being comfortable with this piggyback system for approximately 15h a day. After 1year of using the piggyback system, visual quality and wearing time were maintained. In addition, no adverse ocular effects were found during this period. CONCLUSION This case report shows that in this patient a MAGD CScL could be fitted successfully on a daily silicone hydrogel lens in a piggyback system for keratoconus management, providing good visual quality along with prolonged use times and without adverse effects on the cornea.
Collapse
Affiliation(s)
- Esteban Porcar
- Department of Optics, Optometry and Vision Sciences, Physics College, University of Valencia, Burjassot, Valencia 46100, Spain.
| | - Juan Carlos Montalt
- Department of Optics, Optometry and Vision Sciences, Physics College, University of Valencia, Burjassot, Valencia 46100, Spain
| | - Enrique España-Gregori
- Department of Surgery, Ophthalmology unit, La Fe University and Polytechnic Hospital, Faculty of Medicine and Odontology, University of Valencia, Hospital la Fe, Valencia 46026, Spain
| | - Cristina Peris-Martínez
- FISABIO Oftalmología Médica (FOM), Cornea Unit and Anterior Segment Diseases, Catholic University of Valencia, Valencia 46015, Spain
| |
Collapse
|
6
|
Post-LASIK Visual Quality With a Corneoscleral Contact Lens to Treat Irregular Corneas. Eye Contact Lens 2017; 43:46-50. [DOI: 10.1097/icl.0000000000000231] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
7
|
Effect of multipurpose solutions on in vivo surface wettability of a silicone hydrogel lens. Cont Lens Anterior Eye 2016; 39:461-465. [PMID: 27484710 DOI: 10.1016/j.clae.2016.07.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2016] [Revised: 06/12/2016] [Accepted: 07/19/2016] [Indexed: 11/20/2022]
Abstract
PURPOSE To compare the in vivo surface wettability of silicone hydrogel (SiHy) contact lenses pre-soaked overnight in different multipurpose solutions (MPS) and normal saline. METHODS In this double-blinded, randomized and self-controlled study, 36 subjects were fitted with three pairs of contact lenses (senofilcon A) pre-soaked overnight in five different MPS and saline in a randomized order. Each pair of lenses (pre-soaked in two different solutions the night before) were worn for 15min before assessment of pre-lens non-invasive tear break-up time (PL-NITBUT) using the Medmont corneal topographer (video recording). Corneal integrity was assessed using a slit lamp and a resting interval of 20min was allowed between each pair of lenses to ensure post-lens wear corneal integrity. RESULTS Thirty subjects completed the study. The median PL-NITBUT ranged from 2.84s to 3.08s with lenses pre-soaked in different MPS, compared to 2.78s with lenses pre-soaked in saline. No significant differences in PL-NITBUT were found among lenses pre-soaked in different solutions (p=0.647). CONCLUSION In vivo surface wettability, in terms of PL-NITBUT after 15min of lens wear, of senofilcon A contact lenses pre-soaked overnight in different MPS were not significantly different from those pre-soaked in saline.
Collapse
|
8
|
Vasudevan B, Fisher B, Case B, Lam P, Wayman J. Progression of lower and higher-order aberrations: a longitudinal study. BMC Ophthalmol 2015; 15:11. [PMID: 25618162 PMCID: PMC4417337 DOI: 10.1186/1471-2415-15-11] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2014] [Accepted: 01/10/2015] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The aim of the present study was to investigate the effect of near-work on lower and higher-order aberrations, and its progression over a 9-month period during the school year. METHODS Data from 24 young-adult myopic eyes, and 24 non-myopic eyes were used in this investigation. The lower-order aberrations, coma, spherical aberration (SA), and total root mean square (RMS) of higher order aberrations (total HOA) were measured using an open-field iTrace aberrometer, at both the initial baseline evaluation, and then at the follow-up visits over a 9-month period. Pupil size of 4 mm was used for the aberration measurements. RESULTS The group mean (SD) of the subjects (mean age: 23.6 +/- 3.4 years) at the initial and follow-up visit was 0.47D (0.47D) and 0.31D (0.41D), in the non-myopes and -3.58D (2.08D) and -3.86D (2.14D) in the myopes, respectively. Significant increases in myopic refraction were observed. The group mean (SD) total HOA at the initial and final visit was 0.12 (0.08) and 0.11 (0.06) microns, in the non-myopes, and 0.15 (0.08) and 0.15 (0.08) microns, in the myopes, respectively. The group mean RMS of the coma at the initial and final visit was 0.06 (0.04) and 0.07 (0.05), in the non-myopes, and 0.08 (0.06) and 0.09 (0.06) microns, in the myopes, respectively. The group mean SA of the subjects at the initial and last visit was 0.04 (0.04) and 0.03 (0.03), in the non-myopes, and 0.04 (0.04) and 0.04 (0.04) microns, in the myopes, respectively. CONCLUSIONS There was a significant difference in myopic refraction, over the 9-month assessment period. However, no significant difference in total HOA, SA, and coma between the initial and follow-up visits in both the myopes and the non-myopes was observed.
Collapse
Affiliation(s)
| | - Brian Fisher
- College of Optometry Midwestern University, Glendale, AZ, 85308, USA
| | - Barry Case
- College of Optometry Midwestern University, Glendale, AZ, 85308, USA
| | - Phu Lam
- College of Optometry Midwestern University, Glendale, AZ, 85308, USA
| | - Jeff Wayman
- College of Optometry Midwestern University, Glendale, AZ, 85308, USA
| |
Collapse
|
9
|
New-Generation Hybrid Contact Lens for the Management of Extreme Irregularity in a Thin Cornea After Unsuccessful Excimer Laser Refractive Surgery. Eye Contact Lens 2014; 40:e16-20. [DOI: 10.1097/icl.0b013e31829e8f90] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
10
|
Rodriguez-Vallejo M, Benlloch J, Pons A, Monsoriu JA, Furlan WD. The effect of fractal contact lenses on peripheral refraction in myopic model eyes. Curr Eye Res 2014; 39:1151-60. [PMID: 24749733 DOI: 10.3109/02713683.2014.903498] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE To test multizone contact lenses in model eyes: Fractal Contact Lenses (FCLs), designed to induce myopic peripheral refractive error (PRE). METHODS Zemax ray-tracing software was employed to simulate myopic and accommodation-dependent model eyes fitted with FCLs. PRE, defined in terms of mean sphere M and 90°-180° astigmatism J180, was computed at different peripheral positions, ranging from 0 to 35° in steps of 5°, and for different pupil diameters (PDs). Simulated visual performance and changes in the PRE were also analyzed for contact lens decentration and model eye accommodation. For comparison purposes, the same simulations were performed with another commercially available contact lens designed for the same intended use: the Dual Focus (DF). RESULTS PRE was greater with FCL than with DF when both designs were tested for a 3.5 mm PD, and with and without decentration of the lenses. However, PRE depended on PD with both multizone lenses, with a remarkable reduction of the myopic relative effect for a PD of 5.5 mm. The myopic PRE with contact lenses decreased as the myopic refractive error increased, but this could be compensated by increasing the power of treatment zones. A peripheral myopic shift was also induced by the FCLs in the accommodated model eye. In regard to visual performance, a myopia under-correction with reference to the circle of least confusion was obtained in all cases for a 5.5 mm PD. The ghost images, generated by treatment zones of FCL, were dimmer than the ones produced with DF lens of the same power. CONCLUSIONS FCLs produce a peripheral myopic defocus without compromising central vision in photopic conditions. FCLs have several design parameters that can be varied to obtain optimum results: lens diameter, number of zones, addition and asphericity; resulting in a very promising customized lens for the treatment of myopia progression.
Collapse
|
11
|
Montés-Micó R, Belda-Salmerón L, Ferrer-Blasco T, Albarrán-Diego C, García-Lázaro S. On-eye optical quality of daily disposable contact lenses for different wearing times. Ophthalmic Physiol Opt 2013; 33:581-91. [DOI: 10.1111/opo.12044] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2012] [Accepted: 02/07/2013] [Indexed: 12/01/2022]
|
12
|
Repeatability of internal aberrometry with a new simultaneous capture aberrometer/corneal topographer. Optom Vis Sci 2012; 89:929-38. [PMID: 22543999 DOI: 10.1097/opx.0b013e31825017c4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
PURPOSE To compare repeatability of internal eye aberrations derived from aberrometry and corneal topography (CT) measured simultaneously by the Innovative Visual Systems Discovery, against time displaced but same instrument measurement (Nidek OPD-Scan 3), and time displaced different instrument measurement (Medmont E300 and Imagine Eyes irx3). METHODS Three aberrometry and CT measurements were captured with each instrument, except for the OPD-Scan 3 where three aberrometry scans were followed by a single CT. Measurements were repeated across 2 days. Corneal surface Zernike coefficients were derived from CT and subtracted from aberrometry to establish internal aberration coefficients. For the OPD-Scan 3, internal Zernike coefficients were derived by the instrument's software. Repeatability for second-order root mean square (RMS), spherical aberration, coma RMS, trefoil RMS, and the refraction components M, J0, and J45 were assessed using intraclass correlation coefficient (ICC). RESULTS Intrasession repeatability was similar between the Discovery and E300/irx3, with the E300/irx3 slightly more repeatable for second-order RMS. Across days, the Discovery was most repeatable for second-order RMS (ICC 0.98) followed by the E300/irx3 (ICC 0.96) and OPD-Scan 3 (ICC 0.88). All instruments were less repeatable for higher order aberrations with only the Discovery moderately repeatable for spherical aberration and trefoil RMS (both ICC ≥ 0.75). The Discovery was highly repeatable for all derived refractive components (ICC ≥ 0.96). The E300/irx3 was highly repeatable for M (ICC 0.98) and moderately repeatable for J0 (ICC 0.89). The OPD-Scan 3 was highly repeatable for the M component (ICC 0.98) but not repeatable for the cylindrical components. CONCLUSIONS The Discovery was highly repeatable for second-order RMS and derived refractive components. The lower repeatability for internal higher order aberrations measured with all instruments suggests caution in their use until further work is carried out to investigate sources of error and to develop methods to improve repeatability.
Collapse
|
13
|
Hartwig A, Murray IJ, Radhakrishnan H. Peripheral aberration measurements: elliptical pupil transformation and variations in horizontal coma across the visual field. Clin Exp Optom 2011; 94:443-51. [PMID: 21668500 DOI: 10.1111/j.1444-0938.2011.00624.x] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND The aim was to determine the critical eccentricity at which two methods of elaborating peripheral wavefront measurements are significantly different and to characterise horizontal coma in healthy young adults. METHODS Peripheral aberrations were determined for 20 observers for central and eight peripheral gaze positions up to 20° using an IRX-3 aberrometer. In one subject, additional measurements up to 40° were obtained. Two definitions of stretching coefficients were compared. The raw empirical data were compared with theoretical modelling. RESULTS For both 3.5 mm and 6.0 mm pupils, no significant differences were observed between recalculated and non-recalculated elliptical pupils for both methods (p > 0.05) up to 20° eccentricity. For eccentricities greater than 20° and up to 40°, significant differences between circular and elliptical pupils at some eccentricities were apparent, which corresponded to theoretical models. Wide individual variations in horizontal coma across the peripheral field were observed. CONCLUSIONS The data suggest that for eyes with average levels of aberrations, the elliptical transformation is of no practical importance for eccentricities up to 20°. In some cases the slope of horizontal coma was reversed compared with previous findings in normal eyes.
Collapse
Affiliation(s)
- Andreas Hartwig
- Faculty of Life Sciences, University of Manchester, Manchester, United Kingdom
| | | | | |
Collapse
|
14
|
Baskaran K, Theagarayan B, Carius S, Gustafsson J. Repeatability of Peripheral Aberrations in Young Emmetropes. Optom Vis Sci 2010; 87:751-9. [DOI: 10.1097/opx.0b013e3181f36336] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
15
|
Jinabhai A, O’Donnell C, Radhakrishnan H. A Comparison between Subjective Refraction and Aberrometry-Derived Refraction in Keratoconus Patients and Control Subjects. Curr Eye Res 2010; 35:703-14. [DOI: 10.3109/02713681003797921] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
16
|
Chalmers RL, Hunt C, Hickson-Curran S, Young G. Struggle with hydrogel CL wear increases with age in young adults. Cont Lens Anterior Eye 2009; 32:113-9. [DOI: 10.1016/j.clae.2008.12.001] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2008] [Revised: 12/22/2008] [Accepted: 12/23/2008] [Indexed: 11/29/2022]
|
17
|
Affiliation(s)
- Naoyuki Maeda
- Department of Ophthalmology, Osaka University Medical School, Osaka, Japan.
| |
Collapse
|