1
|
Ponzini E, Maspero F, Galli A, Tavazzi S. In-vitro dehydration kinetics coefficient of Kalifilcon A and other contact lens materials. Sci Rep 2024; 14:7870. [PMID: 38570546 PMCID: PMC10991492 DOI: 10.1038/s41598-024-55937-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 02/29/2024] [Indexed: 04/05/2024] Open
Abstract
In contact lens (CL) wear, dehydration needs to be tailored to avoid dryness and related symptoms. In this view, this work aims to assess and compare the in-vitro dehydration kinetics of five CL materials, including the newly developed Kalifilcon A CL. At 36 °C and 60% relative humidity, the in-vitro dehydration kinetics of the different CLs were compared using a gravimetric method. CLs were analyzed either after a rinse of a few seconds in preservative-free saline solution or after a 24-h incubation in the same solution. A model based on the Fick diffusion equation was employed to deduce a water kinetics coefficient, providing insights into water diffusion within the polymeric matrix. The study reveals that all materials exhibit a non-Fickian dehydration behavior, with significant differences in dehydration kinetics coefficients and dehydration rate slopes. Etafilcon A and Omafilcon A, both hydrogel CLs, exhibit a similar behavior, different compared to the pattern shown by Senofilcon A and Delefilcon A, silicone-hydrogel CLs. Notably, Kalifilcon A, despite being a silicone-hydrogel, displays a hydration behavior reminiscent of hydrogel CLs.
Collapse
Affiliation(s)
- Erika Ponzini
- Materials Science Department, University of Milano Bicocca, Via R. Cozzi 55, 20125, Milan, Italy.
- COMiB Research Center, University of Milano Bicocca, Via R. Cozzi 55, 20125, Milan, Italy.
| | - Francesco Maspero
- Materials Science Department, University of Milano Bicocca, Via R. Cozzi 55, 20125, Milan, Italy
| | - Anna Galli
- Materials Science Department, University of Milano Bicocca, Via R. Cozzi 55, 20125, Milan, Italy
| | - Silvia Tavazzi
- Materials Science Department, University of Milano Bicocca, Via R. Cozzi 55, 20125, Milan, Italy
- COMiB Research Center, University of Milano Bicocca, Via R. Cozzi 55, 20125, Milan, Italy
| |
Collapse
|
2
|
Itokawa T, Yamasaki K, Suzuki T, Koh S. Advances in Contact Lens Care Solutions: PVP-I Disinfectant and HAD Wetting Agents From Japan. Eye Contact Lens 2024; 50:91-101. [PMID: 38019569 DOI: 10.1097/icl.0000000000001060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/28/2023] [Indexed: 11/30/2023]
Abstract
ABSTRACT Half of the individuals who wear contact lenses use reusable lenses that require proper care. Improper contact lens (CL) care and using inadequate disinfecting solutions can lead to lens contamination, CL-related microbial keratitis, and Acanthamoeba keratitis. Oxidative disinfecting solutions, such as hydrogen peroxide, show higher efficacy than multipurpose solutions. Povidone-iodine (PVP-I), an oxidative disinfectant used in ophthalmic surgery, has been proven to be safe and effective. The PVP-I system, a CL disinfecting solution developed in Japan, has demonstrated excellent antimicrobial and antiviral properties. Although CL discomfort does not have a risk of ocular disorders with poor visual prognosis, such as keratitis, CL discomfort can still lead to lens dropout and thus needs to be addressed. To mitigate CL discomfort, it is essential to use disinfecting solutions containing surfactants and wetting agents that improve wettability of the lens surface. A CL solution containing hyaluronic acid derivatives (HADs) as wetting agents that permanently adhere to the lens surface to improve wettability of the lens surface was developed in Japan. There is potential for HAD to be integrated into various solutions. This article reviews the efficacy of novel PVP-I-based disinfecting solution and HAD wetting agents.
Collapse
Affiliation(s)
- Takashi Itokawa
- Department of Ophthalmology (T.I., T.S.), Toho University, Tokyo, Japan; OPHTECS Corporation (K.Y.), Kobe Research Center, Kobe, Japan; Ishizuchi Eye Clinic (T.S.), Ehime, Japan; Department of Innovative Visual Science (S.K.), Osaka University Graduate School of Medicine, Osaka, Japan; and Department of Ophthalmology (S.K.), Osaka University Graduate School of Medicine, Osaka, Japan
| | | | | | | |
Collapse
|
3
|
Multipurpose Lens Care Systems and Silicone Hydrogel Contact Lens Wettability: A Systematic Review. Eye Contact Lens 2022; 48:356-361. [DOI: 10.1097/icl.0000000000000914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/12/2022] [Indexed: 11/26/2022]
|
4
|
Montani G, Martino M. Tear Film Characteristics During Wear of Daily Disposable Contact Lenses. Clin Ophthalmol 2020; 14:1521-1531. [PMID: 32581509 PMCID: PMC7279739 DOI: 10.2147/opth.s242422] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Accepted: 04/23/2020] [Indexed: 01/30/2023] Open
Abstract
Purpose To evaluate changes induced over time by three daily disposable (DD) contact lenses on tear meniscus height (TMH), pre-lens non-invasive break-up time (pre-lens NIBUT), tear film osmolarity (TO) and objective quality of vision (OQV). Patients and Methods Forty-six subjects enrolled in this prospective open-label unmasked non-randomized simultaneous comparative cross-over study. For the first week of the study, subjects wore a nesofilcon A lens in the right eye and a delefilcon A lens in the left eye. After 3 days of washout, for the second week, subjects wore a nesofilcon A lens in the left eye and a stenfilcon A lens in the right eye. TMH, pre-lens NIBUT, TO and OQV were measured before contact lens fitting and for each contact lens combination on day 1 at 20 minutes and on day 7 after ≥8 hours of wear. OQV measurement included the changes of objective scatter index (OSI), the stability index (SI) and the fluctuation index (FI) calculated in a range of time of 20 s from a blink. Results TMH was unchanged at 20 minutes wear of all lenses but was significantly reduced after 8 or more hours wear (on day 7) of delefilcon A and stenfilcon A, respectively. Pre-lens NIBUT was significantly reduced with all lenses, while no significant change in TO was observed with any lens. SI and FI increased significantly for all lenses at both wear times. Conclusion While the presence of any contact lens on the eye challenges the tear film, nesofilcon A contact lenses, despite their high water content, compared to delefilcon A and stenfilcon A contact lenses, showed a lower overall effect. We speculate that superior tear film behavior while wearing nesofilcon A lenses may translate to improved subjective comfort, but this remains to be evaluated.
Collapse
Affiliation(s)
- Giancarlo Montani
- Dipartimento di Matematica e Fisica "Ennio De Giorgi", CERCA Università del Salento, Lecce, Italy
| | - Maurizio Martino
- Dipartimento di Matematica e Fisica "Ennio De Giorgi", CERCA Università del Salento, Lecce, Italy
| |
Collapse
|
5
|
Korogiannaki M, Jones L, Sheardown H. Impact of a Hyaluronic Acid-Grafted Layer on the Surface Properties of Model Silicone Hydrogel Contact Lenses. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:950-961. [PMID: 30537839 DOI: 10.1021/acs.langmuir.8b01693] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The introduction of high oxygen transmissibility silicone hydrogel lenses ameliorated hypoxia-related complications, making them the most prescribed type of contact lens (CL). Despite the progress made over the last 2 decades to improve their clinical performance, symptoms of ocular dryness and discomfort and a variety of adverse clinical events are still reported. Consequently, the rate of CL wear discontinuation has not been appreciably diminished by their introduction. Aiming to improve the interfacial interactions of silicone hydrogel CLs with the ocular surface, a biomimetic layer of hydrophilic glycosaminoglycan hyaluronic acid (HA) (100 kDa) was covalently attached to the surface of model poly(2-hydroxyethyl methacrylate- co-3-methacryloxypropyl-tris-(trimethylsiloxy)silane) (pHEMA- co-TRIS) silicone hydrogel materials via UV-induced thiol-ene "click" chemistry. The surface structural changes after each modification step were studied by Fourier transform infrared spectroscopy-attenuated total reflectance and X-ray photoelectron spectroscopy (XPS). Successful grafting of a homogeneous HA layer to the surface of the model silicone hydrogels was confirmed by the consistent appearance of N (1s) and the significant decrease of the Si (2p) peaks, as determined by low-resolution angle-resolved XPS. The HA-grafted surfaces demonstrated reduced contact angles, dehydration rate, and nonspecific deposition of lysozyme and albumin, while maintaining their optical transparency (>90%). In vitro studies demonstrated that the HA-grafted pHEMA- co-TRIS materials did not show any toxicity to human corneal epithelial cells. These results suggest that surface immobilization of HA via thiol-ene "click" chemistry can be used as a promising surface treatment for silicone hydrogel CLs.
Collapse
Affiliation(s)
- Myrto Korogiannaki
- Department of Chemical Engineering , McMaster University , Hamilton L8S 4L8 , Ontario , Canada
| | - Lyndon Jones
- Centre for Ocular Research & Education, School of Optometry and Vision Science , University of Waterloo , Waterloo N2L 3G1 , Ontario , Canada
| | - Heather Sheardown
- Department of Chemical Engineering , McMaster University , Hamilton L8S 4L8 , Ontario , Canada
| |
Collapse
|
6
|
Tong L, Teng LS. Review of Literature on Measurements of Non-invasive Break Up Times, Lipid Morphology and Tear Meniscal Height Using Commercially Available Hand-held Instruments. Curr Eye Res 2018; 43:567-575. [PMID: 29452004 DOI: 10.1080/02713683.2018.1437454] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Purpose/aims: Dry eye is a common multi-factorial disease characterized by tearfilm dysfunction. Diagnosis of dry eye requires documentation of tear status with non-invasive tear break up times (NIBUT), tear meniscal height (TMH), and tearfilm lipid layer. These parameters objectively assess tear stability and indirectly, the functional impact of meibomian gland dysfunction. While it is obvious that portable instrumentation gives broader access than fixed instrumentation, its value would be limited if it is unreliable and its precision and accuracy substantially worse than fixed instruments. MATERIALS/METHODS Because of the lack of systematic reviews concerning the Tearscope, we performed a scoping review of the literature to determine 1. the ranges of the tear parameters as measured by the device, 2. relationship between these measurements and other clinical variables, 3. Information about intra or inter-observer agreement, and comparison with another technique, where available. RESULTS We found 22 reports related to NIBUT, 18 reports concerning tearfilm lipid morphology (LM) based on classification of interference patterns, and 8 reports on TMH. While publication of these reports indicates an acceptance of the reliability of portable instruments, we interrogated these studies further to evaluate the results obtained from portable devices and found that there was no equivalent measurements in fixed devices (LM) or measurements differ considerably from fixed devices (NIBUT). In the case of TMH, portable measurements were similar to those by traditional slit-lamp microscopy. There were relatively few studies on TMH measured using handheld devices, but it was found to be correlated to NIBUT but not the Schirmer test values. CONCLUSIONS Imaging algorithms in portable tearfilm instruments should be further standardized to facilitate wider adoption and evaluation. In the next few years, new emerging technologies will employ a strategy of non-invasive tear testing that is portable and relatively inexpensive, and these will enhance adoption of such tools in the clinic.
Collapse
Affiliation(s)
- Louis Tong
- a Singapore National Eye Centre , Singapore.,b Singapore Eye Research Institute , Singapore.,c Duke-NUS Medical School , Singapore.,d Yong Loo Lin School of Medicine , National University of Singapore , Singapore
| | | |
Collapse
|
7
|
|
8
|
|
9
|
Gavara R, Compañ V. Oxygen, water, and sodium chloride transport in soft contact lenses materials. J Biomed Mater Res B Appl Biomater 2016; 105:2218-2231. [DOI: 10.1002/jbm.b.33762] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2016] [Revised: 06/22/2016] [Accepted: 07/11/2016] [Indexed: 11/09/2022]
Affiliation(s)
- Rafael Gavara
- Packaging Group, Instituto de Agroquímica y Tecnología de Alimentos; Consejo Superior de Investigaciones Científicas (IATA-CSIC), Avda, Agustín Escardino; 46980 Paterna Spain
| | - Vicente Compañ
- Escuela Técnica Superior de Ingenieros Industriales, Departamento de Termodinámica Aplicada; Universidad Politécnica de Valencia, Camino de vera s/n; 46020 Valencia Spain
| |
Collapse
|
10
|
Ritz U, Kögler P, Höfer I, Frank P, Klees S, Gebhard S, Brendel C, Kaufmann K, Hofmann A, Rommens PM, Jonas U. Photocrosslinkable polysaccharide hydrogel composites based on dextran or pullulan–amylose blends with cytokines for a human co-culture model of human osteoblasts and endothelial cells. J Mater Chem B 2016; 4:6552-6564. [DOI: 10.1039/c6tb00654j] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
Polysaccharide hyrogel composites demonstrate fundamental potential as biomaterials for bone regeneration in vitro.
Collapse
Affiliation(s)
- Ulrike Ritz
- University Medical Center of the Johannes Gutenberg University Mainz
- Department of Orthopaedics and Traumatology
- Biomatics Group Mainz
- Germany
| | - Peter Kögler
- Macromolecular Chemistry
- University of Siegen
- Germany
| | - Isabel Höfer
- Macromolecular Chemistry
- University of Siegen
- Germany
- TU Hamburg-Harburg
- Umwelttechnik und Energiewirtschaft
| | - Petra Frank
- Macromolecular Chemistry
- University of Siegen
- Germany
| | - Sven Klees
- Macromolecular Chemistry
- University of Siegen
- Germany
| | | | | | | | - Alexander Hofmann
- University Medical Center of the Johannes Gutenberg University Mainz
- Department of Orthopaedics and Traumatology
- Biomatics Group Mainz
- Germany
| | - Pol Maria Rommens
- University Medical Center of the Johannes Gutenberg University Mainz
- Department of Orthopaedics and Traumatology
- Biomatics Group Mainz
- Germany
| | - Ulrich Jonas
- Macromolecular Chemistry
- University of Siegen
- Germany
| |
Collapse
|
11
|
Performance of three multipurpose disinfecting solutions with a silicone hydrogel contact lens. BIOMED RESEARCH INTERNATIONAL 2015; 2015:216932. [PMID: 25918703 PMCID: PMC4396003 DOI: 10.1155/2015/216932] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2014] [Revised: 03/04/2015] [Accepted: 03/09/2015] [Indexed: 11/18/2022]
Abstract
Purpose. To evaluate the clinical performance of a silicone hydrogel (Si-Hy) soft contact lens (CL) in combination with three different multipurpose disinfecting solutions (MPDSs). Methods. This was a prospective, randomized, single-masked, crossover, and comparative study in which 31 habitual soft CL wearers were randomly assigned to one of the three MPDSs (Synergi, COMPLETE RevitaLens, and OPTI-FREE PureMoist) for 1 month with a 1-week wash-out period between each exposure. All subjects were successfully refitted with a Si-Hy CL (Biofinity). Subjects were then scheduled for follow-up visits after 1 month of lens wear, being evaluated at 2 and 8 hours after lens insertion. Visual Analogue Scales (VAS) were used to gauge comfort rating. Results. The tarsal conjunctiva showed a significantly different degree of lid redness between the MPDSs at the 2-hour visit (P < 0.05, Kruskal-Wallis test), being lower for COMPLETE RevitaLens compared to the other two MPDSs (Mann-Whitney U test). Furthermore, a significantly different degree of lid roughness at the 8-hour visit was seen (P < 0.05, Kruskal-Wallis test), being higher for Synergi (Mann-Whitney U test). The subjective comfort was similar with the three MPDSs. Conclusion. Tarsal conjunctival response should be also considered in the context of the clinical performance of MPDs at the ocular surface.
Collapse
|
12
|
Overview of factors that affect comfort with modern soft contact lenses. Cont Lens Anterior Eye 2014; 37:65-76. [DOI: 10.1016/j.clae.2013.08.154] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2013] [Revised: 07/31/2013] [Accepted: 08/13/2013] [Indexed: 11/21/2022]
|
13
|
Multi-site clinical assessment of Complete Revitalens MPDS in 2981 contact lens wearers across Europe and USA. Cont Lens Anterior Eye 2013; 36:289-93. [DOI: 10.1016/j.clae.2013.05.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2012] [Revised: 03/30/2013] [Accepted: 05/31/2013] [Indexed: 11/22/2022]
|