Fujimoto MJ, van der Worp E, Kinoshita B, Lampa M, Coldrick BJ, Caroline P. Daily disposable soft lens sagittal depth and other lens parameter changes measured at room temperature (20 °C) and on-eye temperature (34 °C). Cont Lens Anterior Eye 2024; 47:102160. [PMID: 38570253 DOI: 10.1016/j.clae.2024.102160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 02/25/2024] [Accepted: 03/26/2024] [Indexed: 04/05/2024]
Abstract
PURPOSE To investigate the differences in contact lens sagittal depth (CL-SAG), base curve (BC), and overall lens diameter (OAD) of daily disposable (DD) SCLs at room temperature (20 °C) and on-eye (34 °C) temperature. METHODS Twelve different spherical daily SCLs were analyzed (labeled power -3.00 D) at 20 °C and 34 °C. The posterior CL-SAG, BC, and OAD were measured directly using a spectral domain OCT-based instrument (Optimec is830). RESULTS The CL-SAG range for the daily disposable lenses measured at 20 °C was 3468-4016 µm. At 34 °C, the DD CL-SAG of all lenses individually decreased compared to 20 °C (t = 7.78, p < 0.001), ranging from 3385 to 3913 µm. On average at the higher temperature, the measured overall lens diameter was smaller (t = 8.18, p < 0.001) and the BC was marginally steeper (t = 2.11, p = 0.058). CONCLUSIONS Soft lens parameters change when equilibrated from room temperature (20 °C) to on-eye temperature (34 °C). All lenses shrink when going to on-eye temperature (both lens diameter and CL-SAG decreases), compared to lenses measured at room temperature by ISO standards. Higher water content materials tend to have greater changes to the lens parameters compared to lower water content material lenses.
Collapse
|
2
|
Itokawa T, Okajima Y, Iwashita H, Koji K, Tashiro S, Suzuki T, Hori Y. Association between dryness sensation and ocular surface temperature and conjunctival blood flow in soft contact lens wearers. Cont Lens Anterior Eye 2024; 47:102166. [PMID: 38604915 DOI: 10.1016/j.clae.2024.102166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2023] [Revised: 04/02/2024] [Accepted: 04/04/2024] [Indexed: 04/13/2024]
Abstract
PURPOSE To investigate the association between dryness, ocular surface temperature (OST), and conjunctival blood flow (CBF) in soft contact lens (SCL) wearers after airflow stimulation. METHODS After recruiting 21 SCL wearers (mean age, 25.3 ± 4.2 years), subjects used two different daily disposable silicone hydrogel SCLs (narafilcon A and delefilcon A lenses). On three of four measurement days, excluding the first, OST, CBF, tear meniscus height (TMH), and non-invasive tear break-up time (NIBUT) were measured after airflow stimulation at a rate of 3 m/s for 10 min. The measurements were conducted without SCLs on the first and second days, and with different SCLs on the third and fourth days. Dryness was evaluated using the visual analogue scale (VAS). These parameters were compared between the two types of SCLs, and their association with the dryness sensation was then investigated. RESULTS Dryness was significantly weakly correlated with OST (r = -0.375, p < 0.05) and CBF (r = 0.339, p < 0.05). TMH, NIBUT, and VAS scores for dryness with the delefilcon A lens (0.15 ± 0.05 mm, 3.7 ± 01.7 s and 29.4 ± 16.9) were significantly higher, longer, and lower, respectively, than those with the narafilcon A lens (0.12 ± 0.05 mm, 2.3 ± 1.7 s and 35.9 ± 17.0; p < 0.05, p < 0.01 and p < 0.01). The changes in the OST and CBF between with and without the delefilcon A lens (-0.36 ± 0.35 °C and 0.99 ± 0.19) were significantly small compared to the narafilcon A lens (-0.60 ± 0.42 °C and 1.11 ± 0.21; p < 0.01 for both comparisons). CONCLUSION Dryness was correlated with OST and CBF, which indicates that when dryness was high, OST was low and CBF was high. These results suggest that OST and CBF assessments are effective for evaluating dryness sensation.
Collapse
Affiliation(s)
- Takashi Itokawa
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan.
| | - Yukinobu Okajima
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan; Tsunashima Eye Clinic, Yokohama, Kanagawa, Japan
| | - Hiroko Iwashita
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan
| | - Kakisu Koji
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan
| | - Shigeki Tashiro
- Clinical Research Center, Nagasaki University Hospital, Nagasaki, Japan
| | - Takashi Suzuki
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan; Ishizuchi Eye Clinic, Niihama, Ehime, Japan
| | - Yuichi Hori
- Department of Ophthalmology, Toho University Graduate School of Medicine, Tokyo, Japan
| |
Collapse
|
3
|
Morgan PB, Murphy PJ, Gifford KL, Gifford P, Golebiowski B, Johnson L, Makrynioti D, Moezzi AM, Moody K, Navascues-Cornago M, Schweizer H, Swiderska K, Young G, Willcox M. CLEAR - Effect of contact lens materials and designs on the anatomy and physiology of the eye. Cont Lens Anterior Eye 2021; 44:192-219. [PMID: 33775377 DOI: 10.1016/j.clae.2021.02.006] [Citation(s) in RCA: 32] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/19/2022]
Abstract
This paper outlines changes to the ocular surface caused by contact lenses and their degree of clinical significance. Substantial research and development to improve oxygen permeability of rigid and soft contact lenses has meant that in many countries the issues caused by hypoxia to the ocular surface have largely been negated. The ability of contact lenses to change the axial growth characteristics of the globe is being utilised to help reduce the myopia pandemic and several studies and meta-analyses have shown that wearing orthokeratology lenses or soft multifocal contact lenses can reduce axial length growth (and hence myopia). However, effects on blinking, ptosis, the function of Meibomian glands, fluorescein and lissamine green staining of the conjunctiva and cornea, production of lid-parallel conjunctival folds and lid wiper epitheliopathy have received less research attention. Contact lens wear produces a subclinical inflammatory response manifested by increases in the number of dendritiform cells in the conjunctiva, cornea and limbus. Papillary conjunctivitis is also a complication of all types of contact lenses. Changes to wear schedule (daily disposable from overnight wear) or lens materials (hydrogel from SiHy) can reduce papillary conjunctivitis, but the effect of such changes on dendritic cell migration needs further study. These changes may be associated with decreased comfort but confirmatory studies are needed. Contact lenses can affect the sensitivity of the ocular surface to mechanical stimulation, but whether these changes affect comfort requires further investigation. In conclusion, there have been changes to lens materials, design and wear schedules over the past 20+ years that have improved their safety and seen the development of lenses that can reduce the myopia development. However, several changes to the ocular surface still occur and warrant further research effort in order to optimise the lens wearing experience.
Collapse
Affiliation(s)
- Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK.
| | - Paul J Murphy
- University of Waterloo, School of Optometry and Vision Science, Waterloo, Canada
| | - Kate L Gifford
- School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia
| | - Paul Gifford
- School of Optometry and Vision Science, UNSW Sydney, Australia
| | | | - Leah Johnson
- CooperVision Specialty EyeCare, Gilbert, AZ, United States
| | - Dimitra Makrynioti
- School of Health Rehabilitation Sciences, University of Patras (Aigio), Greece
| | - Amir M Moezzi
- Centre for Ocular Research and Education, University of Waterloo, Canada
| | - Kurt Moody
- Johnson & Johnson Vision Care, Jacksonville, FL, United States
| | | | | | - Kasandra Swiderska
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK
| | | | - Mark Willcox
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
4
|
Chávez-Hurtado P, Pesqueda-Pinedo L, Ceballos-Delgadillo HA, Liñán-Segura A, Figueroa-Ponce H, Quintana-Hau JD. Physicochemical characterization of a DMPC-based nanoemulsion for dry eye and compatibility test with soft contact lenses in vitro. Cont Lens Anterior Eye 2021; 45:101428. [PMID: 33622607 DOI: 10.1016/j.clae.2021.02.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Revised: 02/10/2021] [Accepted: 02/10/2021] [Indexed: 11/26/2022]
Abstract
INTRODUCTION The use of contact lenses (CL) is often associated with hallmark symptoms of dry eye disease (DED) such as red eye and dryness. Even though lipid-based artificial tears are already marketed for DED, there is little evidence that supports their use while wearing soft CL. METHODS An oil in water (O/W) nanoemulsion was formulated with a highly-stable oily phase composed of castor oil and 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC). Physicochemical characterization of the DMPC-based nanoemulsion (DMPC-NE) was performed using the Zetasizer Nano ZSP, and its long-term stability was evaluated over 24 months; in addition, the in vitro cytotoxicity of DMPC-NE was determined by Neutral Red Uptake (NRU) and 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assays. Finally, the physical compatibility of the DMPC-NE with soft CL was tested by measuring the power, diameter, thickness and UV transmittance of two different types of CL. RESULTS DMPC-NE had a mean particle size of 86.48 ± 4.22 nm, a polydispersity index of 0.22 ± 0.01 and a zeta potential of -33.23 ± 0.93 mV that remained with no changes after 24 months. DMPC-NE formulation, free of preservatives, showed no cytotoxicity and it was compatible with the physical properties of FDA-class II and -class IV CL. CONCLUSION DMPC-NE is a highly stable formulation for dry eye that is safe to be used while wearing soft CL.
Collapse
Affiliation(s)
- Paulina Chávez-Hurtado
- Direction of Research & Development, Sophia's Research Center, Zapopan, Jalisco, Mexico.
| | | | | | - Addy Liñán-Segura
- Direction of Research & Development, Sophia's Research Center, Zapopan, Jalisco, Mexico.
| | | | - Juan D Quintana-Hau
- Direction of Research & Development, Sophia's Research Center, Zapopan, Jalisco, Mexico.
| |
Collapse
|
5
|
Kaluzny BJ, Stachura J, Mlyniuk P, Jimenez-Villar A, Wietlicka-Piszcz M, Grulkowski I. Change in the geometry of positive- and negative-powered soft contact lenses during wear. PLoS One 2020; 15:e0242095. [PMID: 33166364 PMCID: PMC7652269 DOI: 10.1371/journal.pone.0242095] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2020] [Accepted: 10/27/2020] [Indexed: 11/21/2022] Open
Abstract
Contact lens wear causes mutual interactions between the ocular surface and the lens, which may affect comfort as well as vision. The aim of this study was to examine deformations in modern positive- and negative-powered silicone hydrogel soft contact lenses (SiH SCLs) after 7 days of continuous wear. This pre-post interventional study included 64 eyes: 42 eyes with myopia of -3.00 D and 22 eyes with hyperopia of +3.00 D. All patients underwent general ophthalmic examination, corneal topography/tomography, total corneal and epithelial thickness mapping, and specular microscopy before and after the wearing period. SiH SCLs made of senofilcon A were worn continuously for 7 days on all eligible eyes. The geometry of the new and used lenses was measured 3 to 6 minutes after removal in two perpendicular planes using a custom-made swept source optical coherence tomography (SS-OCT) system for in vitro measurements. The anterior and posterior radii of curvature decreased in -3.00 D lenses in two perpendicular planes. This effect correlated significantly with average keratometry of the cornea. Sagittal lens height was lower in +3.00 D lens after wear, which correlated moderately with the corneal sagittal height. A significant decrease in central corneal epithelial thickness was observed after wearing +3.0 D lenses. In conclusion, SiH SCLs made of senofilcon A undergo minor deformations after 7-day continuous wear. Geometry modifications are different for -3.00 D and +3.00 D lenses, and they imitate the shape of the anterior eye surface. These geometric changes are accompanied by a decrease in the central thickness of corneal epithelium after +3.00 D lens wear.
Collapse
Affiliation(s)
- Bartlomiej J. Kaluzny
- Division of Ophthalmology and Optometry, Department of Ophthalmology, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland
- * E-mail:
| | - Joanna Stachura
- Division of Ophthalmology and Optometry, Department of Ophthalmology, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland
| | - Patryk Mlyniuk
- Division of Ophthalmology and Optometry, Department of Ophthalmology, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland
| | - Alfonso Jimenez-Villar
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Toruń, Poland
| | - Magdalena Wietlicka-Piszcz
- Department of Theoretical Foundations of Biomedical Sciences and Medical Information Technology, Collegium Medicum, Nicolaus Copernicus University, Bydgoszcz, Poland
| | - Ireneusz Grulkowski
- Institute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Toruń, Poland
| |
Collapse
|
6
|
Smith SM, Zhu D, Pierre D, Gilbert JL, Chinn JA. Effect of multipurpose care solutions upon physical dimensions of silicone hydrogel contact lenses. J Biomed Mater Res B Appl Biomater 2020; 108:1915-1924. [DOI: 10.1002/jbm.b.34533] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2019] [Revised: 10/10/2019] [Accepted: 11/12/2019] [Indexed: 11/08/2022]
Affiliation(s)
- Stephanie M. Smith
- Department of BioengineeringClemson University Clemson South Carolina
- Clemson‐Medical University of South Carolina Bioengineering Program Charleston South Carolina
| | - Dongkai Zhu
- Department of BioengineeringClemson University Clemson South Carolina
- Clemson‐Medical University of South Carolina Bioengineering Program Charleston South Carolina
| | - David Pierre
- Department of BioengineeringClemson University Clemson South Carolina
- Clemson‐Medical University of South Carolina Bioengineering Program Charleston South Carolina
| | - Jeremy L. Gilbert
- Department of BioengineeringClemson University Clemson South Carolina
- Clemson‐Medical University of South Carolina Bioengineering Program Charleston South Carolina
| | | |
Collapse
|
7
|
Sulley A, Dumbleton K. Silicone hydrogel daily disposable benefits: The evidence. Cont Lens Anterior Eye 2020; 43:298-307. [PMID: 32098715 DOI: 10.1016/j.clae.2020.02.001] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 01/18/2020] [Accepted: 02/12/2020] [Indexed: 10/24/2022]
Abstract
Daily disposable (DD) contact lenses first came to the market approximately 25 years ago and eye care professionals (ECPs) started prescribing silicone hydrogel (SiH) contact lenses, primarily for extended or continuous wear, approximately 20 years ago. It has now been over ten years since SiH DD contact lenses have been available, and while SiH materials are routinely prescribed by ECPs for reusable daily wear, hydrogel materials are still frequently selected for the DD modality of contact lens wear. This article reviews the evidence to support the benefits of both a DD modality and SiH materials and how patients' needs may be met with SiH DD contact lenses, with respect to clinical performance, health outcomes, satisfaction, compliance and convenience. Factors which may enable or constrain ECPs from prescribing SiH DD contact lenses, as opposed to hydrogel DD and reusable contact lenses, for more of their patients are discussed with the objective of providing ECPs with a greater understanding of the advantages that can be afforded by prescribing SiH DD contact lenses to both their new and existing contact lens wearers.
Collapse
Affiliation(s)
| | - Kathy Dumbleton
- Clinical Research Scientist and Consultant, Berkeley, CA, USA; Associate Clinical Professor, School of Optometry, University of California Berkeley, CA, USA.
| |
Collapse
|
8
|
Comparison of Silicone Hydrogel and Hydrogel Daily Disposable Contact Lenses. Eye Contact Lens 2018; 44 Suppl 1:S167-S172. [PMID: 28099285 DOI: 10.1097/icl.0000000000000363] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To compare subjective, objective and safety performance of silicone hydrogel (SiHy) daily disposable (DD) with hydrogel (Hy) DD contact lenses. METHOD Retrospective analysis on approximately 40 participants (Px) each in 5 trials. Lenses grouped into SiHy (delefilcon A, somofilcon A, narafilcon A) and Hy (omafilcon A, nelfilcon A). Participants attended follow-up visits at baseline, 2 weeks, 1 and 3 months. Subjective ratings (1-10 scale), adverse events (percentage of Px), physiological variables (0-4 scale), and wearing time were collected at each visit and compared between groups. RESULT Trials enrolled 201 Px totally. No differences in age, sex, and lens wear experience were found between SiHy and Hy groups (P≥0.09). There was greater increase in limbal redness from baseline in Hy group (0.18±0.38 vs. 0.02±0.47, P<0.001), whereas conjunctival staining and indentation were less in Hy group (P<0.001). No differences in comfortable wearing time were found between groups (P=0.41), and comfort at insertion, during day, and end of day was also no different (P≥0.71). Incidence of corneal infiltrative events (SiHy vs. Hy: 6.7% vs. 2.5%; P=0.32) and mechanical adverse events (SiHy vs. Hy: 0.0% vs. 0.0%; P=1.00) were no different. CONCLUSION Though some statistical significance was found between the groups, these differences were within measurement error. Neither material types showed superiority in comfort, and adverse event rates were low with both material types. These findings suggest that choice of material is a patient and practitioner preference; however, for patients at risk of hypoxia-related complications, SiHy materials should be considered.
Collapse
|
9
|
Contact Lens Solutions and Contact Lens Discomfort: Examining the Correlations Between Solution Components, Keratitis, and Contact Lens Discomfort. Eye Contact Lens 2018; 44:355-366. [DOI: 10.1097/icl.0000000000000458] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
10
|
McMonnies CW. An Amplifying Cascade of Contact Lens-Related End-of-Day Hyperaemia and Dryness Symptoms. Curr Eye Res 2018; 43:839-847. [PMID: 29630423 DOI: 10.1080/02713683.2018.1457163] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
End-of-day (EOD) symptoms of dryness are too often the cause of poor soft contact lens (SCL) tolerance and abandonment of wear. This review examines an amplifying cascade model for these symptoms, which involve thin tear layers on contact lens (CL) front surfaces being susceptible to evaporation-related short tear breakup (TBU) times. Susceptibility to faster tear loss by evaporation may be exacerbated by other forms of tear instability, such as lipid and mucin deficiencies as well as lens surface soiling. Bulbar and palpebral conjunctival hyperaemia and associated faster evaporation of warmer pre-conjunctival tears could also contribute to evaporative dry eye EOD symptoms. In CL wearers, a cascade of increasing hyperaemia toward the end of day, associated increasing tear temperature and evaporative loss, shortened TBU times (TBUTs) and increased osmolarity, all elevate the risk of higher symptom levels according to progressive amplification of this cascade. Chronic wound healing responses to SCL wear, perhaps related to limbal conjunctival trauma, stem cell deficiency and persistent epitheliopathy, as well as one or more immune responses, may contribute directly or indirectly to inflammation and the amplifying evaporative dryness cascade. A diurnal cycle that culminates in EOD symptoms appears to involve a process of recovery from causal mechanisms after lens removal, which allows lenses to be worn comfortably, at least initially the next day. Possible recovery processes are discussed in this review as are procedures that may help de-amplify an inflammatory, evaporative dryness cascade and alleviate EOD symptoms. Evidence of an accrual of adverse responses over long periods of more or less successful lens wear indicate an incremental failure to recover from EOD hyperaemia. Such incremental failure could help explain how SCL wear too often needs to be abandoned after many years of comfortable wear.
Collapse
Affiliation(s)
- Charles W McMonnies
- a School of Optometry and Vision Science , University of New South Wales , Kensington , Australia
| |
Collapse
|
11
|
Sulley A, Osborn Lorenz K, Wolffsohn JS, Young G. Theoretical fitting characteristics of typical soft contact lens designs. Cont Lens Anterior Eye 2017; 40:248-252. [PMID: 28501442 DOI: 10.1016/j.clae.2017.04.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2016] [Revised: 04/02/2017] [Accepted: 04/19/2017] [Indexed: 11/18/2022]
Abstract
PUROSE To calculate theoretical fitting success rates (SR) for a range of typical soft contact lens (SCL) designs using a mathematical model. METHOD A spreadsheet mathematical model was used to calculate fitting SR for various SCL designs. Designs were evaluated using ocular topography data from 163 subjects. The model calculated SR based on acceptable edge strain (within range 0-6%) and horizontal diameter overlap (range 0.2-1.2mm). Where lenses had multiple base curves (BCs), eyes unsuccessful with the steeper BC were tested with the flatter BC and aggregate SR calculated. Calculations were based on typical, current, hydrogel and silicone hydrogel SCLs and allowed for appropriate on-eye shrinkage (1.0-2.3%). Theoretical results were compared with those from actual clinical trials. RESULTS Theoretical success rates for one-BC lenses ranged from 60.7% (95% CI 7.2%) to 90.2% (95% CI 3.7%). With two-BC designs, most combinations showed a SR increase with a second BC (84.0%-90.2%). However, one of the two-BC combinations showed only negligible increase with a second BC (72.4%-73.0%). For designs with lower SR, the greatest contributor to failure was inadequate lens diameter. For a given design, differences in shrinkage (i.e. on-eye bulk dehydration) had a significant effect on success rate. In comparison with historical clinical data, there was a positive correlation between small lens fitting prevalence and discomfort reports (r=+0.95, P=<0.001) with a poor correlation between theoretical and actual tight/loose fittings. CONCLUSIONS Mathematical modelling is a useful method for testing SCL design combinations. The results suggest that judicious choice of additional fittings can expand the range of fitting success.
Collapse
Affiliation(s)
- Anna Sulley
- Johnson & Johnson Vision Care Companies, Wokingham, UK.
| | | | | | - Graeme Young
- Aston University, Birmingham, UK; Visioncare Research Ltd, Farnham, UK
| |
Collapse
|
12
|
|
13
|
|
14
|
|
15
|
Differences in Dry Eye Questionnaire Symptoms in Two Different Modalities of Contact Lens Wear: Silicone-Hydrogel in Daily Wear Basis and Overnight Orthokeratology. BIOMED RESEARCH INTERNATIONAL 2016; 2016:1242845. [PMID: 27689073 PMCID: PMC5022233 DOI: 10.1155/2016/1242845] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/03/2016] [Revised: 07/31/2016] [Accepted: 08/01/2016] [Indexed: 11/17/2022]
Abstract
Purpose. To compare the ocular surface symptoms and signs in an adult population of silicone-hydrogel (Si-Hy) contact lens (CL) wearers with another modality of CL wear, overnight orthokeratology (OK). Materials and Methods. This was a prospective and comparative study in which 31 myopic subjects were fitted with the same Si-Hy CL and 23 underwent OK treatment for 3 months. Dry eye questionnaire (DEQ) was filled in at the beginning of the study and then after 15 days, 1 month, and 3 months using each CL modality. The tear quality was evaluated with noninvasive tear break-up time. Tear production was measured with Schirmer test. Tear samples were collected with Schirmer strips being frozen to analyze the dinucleotide diadenosine tetraphosphate (Ap4A) concentration with High-Performance Liquid Chromatography (HPLC). Results. After refitting with ortho-k, a reduction in discomfort and dryness symptoms at the end of the day (p < 0.05, χ2) was observed. No significant changes were observed in Ap4A concentration in any group. Bulbar redness, limbal redness, and conjunctival staining increased significantly in the Si-Hy group (p < 0.05, Kruskal-Wallis test). Conclusion. Discomfort and dryness symptoms at the end of the day are lower in the OK CL group than in the Si-Hy CL group.
Collapse
|
16
|
Navascues-Cornago M, Morgan PB, Maldonado-Codina C. Effect of Three Interventions on Contact Lens Comfort in Symptomatic Wearers: A Randomized Clinical Trial. PLoS One 2015; 10:e0135323. [PMID: 26267853 PMCID: PMC4533967 DOI: 10.1371/journal.pone.0135323] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2015] [Accepted: 07/16/2015] [Indexed: 11/23/2022] Open
Abstract
Purpose To investigate whether carrying out various interventions part way through the day influences comfort in symptomatic daily disposable (DD) contact lens wearers. Methods A subject-masked, randomized, controlled clinical trial was conducted in thirty symptomatic soft lens wearers who wore their habitual DD contact lenses bilaterally for 12 h on two separate days. Five hours after lens application, one of the following three interventions or a control was performed on each eye: replacing the existing lens with a new lens; removing and reapplying the same lens; performing a ‘scleral swish’; and no action (control). Comfort scores were recorded using SMS text messages every hour following lens application using a 0 (causes pain) to 100 (excellent comfort) scale. Comfort scores before lens application, at 6 mins post-application, and at 6 mins post-intervention were also recorded. Results There was a significant reduction in comfort from pre-lens application to 6 mins post-application for all groups (all p<0.05). Comfort gradually decreased from 6 mins to 5 h after lens application for each group (p<0.0001) with no significant difference between groups over the 5-h period (p = 0.09). There was no significant difference in comfort 6 mins post-intervention for any group (all p>0.05). After the intervention, comfort continued to decline (p<0.0001) with slightly lower mean scores for the control group compared to the new lens group (p = 0.003). Change in comfort relative to pre-intervention (5 h) was similar for all groups (p = 0.81). There was no difference in comfort at 12 h between groups (p = 0.83). Conclusion This work has confirmed that comfort shows a continual and significant decline over a 12-h wearing period in symptomatic DD contact lens wearers. None of the interventions investigated had any significant impact on end-of-day comfort. These data suggest discomfort in lens wearers is more heavily influenced by changes to the ocular environment rather than to the lens itself. Trial Registration Controlled-Trials.com ISRCTN10419752 http://www.controlled-trials.com/ISRCTN10419752
Collapse
Affiliation(s)
- Maria Navascues-Cornago
- Eurolens Research, Faculty of Life Sciences, The University of Manchester, Manchester, United Kingdom
- * E-mail:
| | - Philip B. Morgan
- Eurolens Research, Faculty of Life Sciences, The University of Manchester, Manchester, United Kingdom
| | - Carole Maldonado-Codina
- Eurolens Research, Faculty of Life Sciences, The University of Manchester, Manchester, United Kingdom
| |
Collapse
|
17
|
Performance of three multipurpose disinfecting solutions with a silicone hydrogel contact lens. BIOMED RESEARCH INTERNATIONAL 2015; 2015:216932. [PMID: 25918703 PMCID: PMC4396003 DOI: 10.1155/2015/216932] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/14/2014] [Revised: 03/04/2015] [Accepted: 03/09/2015] [Indexed: 11/18/2022]
Abstract
Purpose. To evaluate the clinical performance of a silicone hydrogel (Si-Hy) soft contact lens (CL) in combination with three different multipurpose disinfecting solutions (MPDSs). Methods. This was a prospective, randomized, single-masked, crossover, and comparative study in which 31 habitual soft CL wearers were randomly assigned to one of the three MPDSs (Synergi, COMPLETE RevitaLens, and OPTI-FREE PureMoist) for 1 month with a 1-week wash-out period between each exposure. All subjects were successfully refitted with a Si-Hy CL (Biofinity). Subjects were then scheduled for follow-up visits after 1 month of lens wear, being evaluated at 2 and 8 hours after lens insertion. Visual Analogue Scales (VAS) were used to gauge comfort rating. Results. The tarsal conjunctiva showed a significantly different degree of lid redness between the MPDSs at the 2-hour visit (P < 0.05, Kruskal-Wallis test), being lower for COMPLETE RevitaLens compared to the other two MPDSs (Mann-Whitney U test). Furthermore, a significantly different degree of lid roughness at the 8-hour visit was seen (P < 0.05, Kruskal-Wallis test), being higher for Synergi (Mann-Whitney U test). The subjective comfort was similar with the three MPDSs. Conclusion. Tarsal conjunctival response should be also considered in the context of the clinical performance of MPDs at the ocular surface.
Collapse
|
18
|
Stapleton F, Marfurt C, Golebiowski B, Rosenblatt M, Bereiter D, Begley C, Dartt D, Gallar J, Belmonte C, Hamrah P, Willcox M. The TFOS International Workshop on Contact Lens Discomfort: report of the subcommittee on neurobiology. Invest Ophthalmol Vis Sci 2013; 54:TFOS71-97. [PMID: 24058137 PMCID: PMC5963174 DOI: 10.1167/iovs.13-13226] [Citation(s) in RCA: 77] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2013] [Accepted: 09/10/2013] [Indexed: 12/26/2022] Open
Abstract
This report characterizes the neurobiology of the ocular surface and highlights relevant mechanisms that may underpin contact lens-related discomfort. While there is limited evidence for the mechanisms involved in contact lens-related discomfort, neurobiological mechanisms in dry eye disease, the inflammatory pathway, the effect of hyperosmolarity on ocular surface nociceptors, and subsequent sensory processing of ocular pain and discomfort have been at least partly elucidated and are presented herein to provide insight in this new arena. The stimulus to the ocular surface from a contact lens is likely to be complex and multifactorial, including components of osmolarity, solution effects, desiccation, thermal effects, inflammation, friction, and mechanical stimulation. Sensory input will arise from stimulation of the lid margin, palpebral and bulbar conjunctiva, and the cornea.
Collapse
Affiliation(s)
- Fiona Stapleton
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Carl Marfurt
- Indiana University School of Medicine–Northwest, Gary, Indiana
| | - Blanka Golebiowski
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Mark Rosenblatt
- Weill Cornell Medical College, Cornell University, Ithaca, New York
| | - David Bereiter
- University of Minnesota School of Dentistry, Minneapolis, Minnesota
| | - Carolyn Begley
- Indiana University School of Optometry, Bloomington, Indiana
| | - Darlene Dartt
- Schepens Eye Research Institute, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts
| | - Juana Gallar
- Instituto de Neurociencias de Alicante, Universidad Miguel Hernandez–Consejo Superior de Investigaciones Cientificas, Alicante, Spain
| | - Carlos Belmonte
- Instituto de Neurociencias de Alicante, Universidad Miguel Hernandez–Consejo Superior de Investigaciones Cientificas, Alicante, Spain
| | - Pedram Hamrah
- Massachusetts Eye and Ear Infirmary, Stoneham, Massachusetts
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | | |
Collapse
|