1
|
Buzalewicz I, Kaczorowska A, Fijałkowski W, Pietrowska A, Matczuk AK, Podbielska H, Wieliczko A, Witkiewicz W, Jędruchniewicz N. Quantifying the Dynamics of Bacterial Biofilm Formation on the Surface of Soft Contact Lens Materials Using Digital Holographic Tomography to Advance Biofilm Research. Int J Mol Sci 2024; 25:2653. [PMID: 38473902 DOI: 10.3390/ijms25052653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Revised: 02/15/2024] [Accepted: 02/20/2024] [Indexed: 03/14/2024] Open
Abstract
The increase in bacterial resistance to antibiotics in recent years demands innovative strategies for the detection and combating of biofilms, which are notoriously resilient. Biofilms, particularly those on contact lenses, can lead to biofilm-related infections (e.g., conjunctivitis and keratitis), posing a significant risk to patients. Non-destructive and non-contact sensing techniques are essential in addressing this threat. Digital holographic tomography emerges as a promising solution. This allows for the 3D reconstruction of the refractive index distribution in biological samples, enabling label-free visualization and the quantitative analysis of biofilms. This tool provides insight into the dynamics of biofilm formation and maturation on the surface of transparent materials. Applying digital holographic tomography for biofilm examination has the potential to advance our ability to combat the antibiotic bacterial resistance crisis. A recent study focused on characterizing biofilm formation and maturation on six soft contact lens materials (three silicone hydrogels, three hydrogels), with a particular emphasis on Staphylococcus epidermis and Pseudomonas aeruginosa, both common culprits in ocular infections. The results revealed species- and time-dependent variations in the refractive indexes and volumes of biofilms, shedding light on cell dynamics, cell death, and contact lens material-related factors. The use of digital holographic tomography enables the quantitative analysis of biofilm dynamics, providing us with a better understanding and characterization of bacterial biofilms.
Collapse
Affiliation(s)
- Igor Buzalewicz
- Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
- Research and Development Centre, Regional Specialist Hospital in Wroclaw, 73A H. M. Kamienskiego St., 51-124 Wroclaw, Poland
| | - Aleksandra Kaczorowska
- Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
- Laboratory of Cytobiochemistry, Faculty of Biotechnology, University of Wroclaw, 14a F. Joliot-Curie St., 50-383 Wroclaw, Poland
| | | | - Aleksandra Pietrowska
- Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
| | - Anna Karolina Matczuk
- Department of Pathology, Division of Microbiology, Faculty of Veterinary Medicine, Wroclaw University of Environmental and Life Sciences, 31 C.K. Norwida St., 51-375 Wroclaw, Poland
| | - Halina Podbielska
- Department of Biomedical Engineering, Faculty of Fundamental Problems of Technology, Wroclaw University of Science and Technology, 50-370 Wroclaw, Poland
| | - Alina Wieliczko
- Department of Epizootiology and Veterinary Administration with Clinic of Infectious Diseases, Wroclaw University of Environmental and Life Sciences, 45 Grunwaldzki Square, 50-366 Wroclaw, Poland
| | - Wojciech Witkiewicz
- Research and Development Centre, Regional Specialist Hospital in Wroclaw, 73A H. M. Kamienskiego St., 51-124 Wroclaw, Poland
| | - Natalia Jędruchniewicz
- Research and Development Centre, Regional Specialist Hospital in Wroclaw, 73A H. M. Kamienskiego St., 51-124 Wroclaw, Poland
| |
Collapse
|
2
|
Jones L, Efron N, Bandamwar K, Barnett M, Jacobs DS, Jalbert I, Pult H, Rhee MK, Sheardown H, Shovlin JP, Stahl U, Stanila A, Tan J, Tavazzi S, Ucakhan OO, Willcox MDP, Downie LE. TFOS Lifestyle: Impact of contact lenses on the ocular surface. Ocul Surf 2023; 29:175-219. [PMID: 37149139 DOI: 10.1016/j.jtos.2023.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/08/2023]
Abstract
Several lifestyle choices made by contact lens wearers can have adverse consequences on ocular health. These include being non-adherent to contact lens care, sleeping in lenses, ill-advised purchasing options, not seeing an eyecare professional for regular aftercare visits, wearing lenses when feeling unwell, wearing lenses too soon after various forms of ophthalmic surgery, and wearing lenses when engaged in risky behaviors (e.g., when using tobacco, alcohol or recreational drugs). Those with a pre-existing compromised ocular surface may find that contact lens wear exacerbates ocular disease morbidity. Conversely, contact lenses may have various therapeutic benefits. The coronavirus disease-2019 (COVID-19) pandemic impinged upon the lifestyle of contact lens wearers, introducing challenges such as mask-associated dry eye, contact lens discomfort with increased use of digital devices, inadvertent exposure to hand sanitizers, and reduced use of lenses. Wearing contact lenses in challenging environments, such as in the presence of dust and noxious chemicals, or where there is the possibility of ocular trauma (e.g., sport or working with tools) can be problematic, although in some instances lenses can be protective. Contact lenses can be worn for sport, theatre, at high altitude, driving at night, in the military and in space, and special considerations are required when prescribing in such situations to ensure successful outcomes. A systematic review and meta-analysis, incorporated within the review, identified that the influence of lifestyle factors on soft contact lens dropout remains poorly understood, and is an area in need of further research. Overall, this report investigated lifestyle-related choices made by clinicians and contact lens wearers and discovered that when appropriate lifestyle choices are made, contact lens wear can enhance the quality of life of wearers.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | - Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Kalika Bandamwar
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Harvard Medical School, Boston, MA, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Heiko Pult
- Dr Heiko Pult Optometry & Vision Research, Weinheim, Germany
| | | | - Heather Sheardown
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | | | - Ulli Stahl
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada
| | | | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Silvia Tavazzi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | | | - Mark D P Willcox
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
3
|
Topical Review: Optometry in Nepal-Clinical Practice, Research Advances, and Challenges. Optom Vis Sci 2023; 100:134-142. [PMID: 36728818 DOI: 10.1097/opx.0000000000001980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023] Open
Abstract
SIGNIFICANCE This article reviews educational standard, clinical practice, research advances, and challenges associated with optometry in Nepal and provides critical considerations for contemporary and new optometry programs in countries with similar socioeconomic status and health care systems.Optometry education started in Nepal in 1998 with the primary objective of addressing the unmet needs of eye health and vision care in the country. Over the last two decades, this program has made significant contributions to facilitating and improving the delivery of quality eye care and establishing the nation's eye health system as an exemplary model in South Asia. Despite the positive impact in a short time, optometry education and the profession continue to face several challenges, including a shortage of training resources and facilities, poor quality control and regulation of practice standards, lack of professional recognition, limited pathways for entry to governmental jobs via the national public service commission, and limited clinical and academic opportunities in existing eye care programs. This article reviews current education and clinical practice standards, highlights research advances, and discusses present and future challenges in sustaining and improving the quality of education and advancing the scope of practice of optometry in Nepal. Given the limited access to primary eye care services in Nepal, appropriate professional recognition and integration into the national health system, and initiatives targeted at improving the delivery of optometry education in alignment with successful international models may provide a long-sought solution to making eye care services accessible to all and lowering the burden of visual impairment in the country.
Collapse
|
4
|
Alasadi SZ, Ibraheim W, Almusawi LA. Microbial Contamination of Soft Contact Lenses Among Medical School Students in Southern Iraq. Clin Ophthalmol 2022; 16:3651-3660. [PMID: 36389641 PMCID: PMC9642796 DOI: 10.2147/opth.s383086] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Accepted: 10/13/2022] [Indexed: 11/06/2022] Open
Abstract
Background Contamination of CLs and accessories risks potentially devastating microbial keratitis. We aimed to explore the rate of microbial contamination and predisposing factors among a group of asymptomatic young medical students. Methodology The study included 115 healthy female medical students with a mean age of 21.64 ± 2.02 years between January and November 2021. Information about CL use, wear and care was gathered. Each participant’s CL and case were swabbed for microbiological identification. Univariable and multivariable analyses were conducted to look for associations with a range of factors. Results Overall, 91 participants (79.13%) had at least one contaminated sample (lens and/or case). The rates of contamination of CL and their cases were 66% and 76.5%, respectively. Higher contamination rates were caused by gram-negative bacteria (60% of the contaminated samples) with P. aeruginosa being the most common contaminant both for CL and cases, whereas S. epidermidis and S. aureus were the most common contaminants for the CL and cases, respectively, regarding gram-positive contamination. Multivariable analysis showed younger age as a significant predictor of pseudomonas contamination of the lenses and cases (OR: 12.302, 6.555 for CL & cases, respectively; P = 0.001 for both). Older age was a significant predictor of K. pneumoniae contamination (OR: 4.154, P = 0.007). Pseudomonas contamination of both lenses and cases was predicted by the type of solution used (OR: 10.8 and 13.5, P = 0.001 and 0.003 for bottled and distilled water vs commercially available solutions for CL; OR: 4.5 and 5.8, P = 0.045 and 0.004, respectively, for cases). Pseudomonas case contamination was associated with low frequency of solution change. Conclusion Microbial contamination rate of soft CL and their cases is high among young medical students in comparison to previously reported rates and was predisposed by several poor hygienic practices and wearing regimens.
Collapse
Affiliation(s)
| | - Wijdan Ibraheim
- Department of Microbiology, College of Medicine, University of Basrah, Basrah, Iraq
| | - Loay Abdulmutalib Almusawi
- Department of Surgery, College of Medicine, University of Basrah, Basrah, Iraq
- Correspondence: Loay Abdulmutalib Almusawi, Department of Surgery, College of Medicine, University of Basrah, Basrah, 61022, Iraq, Tel +964 7705559205, Email
| |
Collapse
|
5
|
Arshad M, Carnt N, Tan J, Stapleton F. Effect of Water Exposure on Contact Lens Storage Case Contamination in Soft Lens Wearers. Optom Vis Sci 2021; 98:1002-1010. [PMID: 34570032 DOI: 10.1097/opx.0000000000001772] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE Water exposure during contact lens wear can transfer pathogenic microorganisms to the eye, causing ocular complications. This study determined that water exposure is prevalent among lens wearers and is independently associated with higher case contamination. Contact lens compliance education to minimize water exposure should be reenforced by contact lens organizations and practitioners. PURPOSE Given the increasing association between water exposure and contact lens disease, this study aimed to explore the effect of water exposure and storage case contamination in soft contact lens users. METHODS A total of 165 daily soft lens wearers completed a self-administered questionnaire on contact lens hygiene. Lens cases were collected, and microbial analysis was conducted using an adenosine triphosphate assay (for overall microbial bioburden) and limulus amebocyte lysate assay (for endotoxin levels). The lens hygiene (excellent, >35; moderate, 28 to 35; poor, <28) and water contact (≤1, good; >1, poor) scores measured the compliance and water exposure during lens wear, respectively. Multiple regression determined the association between water behaviors and case contamination. RESULTS The average (standard deviation) age of participants was 28 (13.5) years (18 to 78 years), and 65% were female. The average overall microbial bioburden of storage cases was 3.10 (0.98) log colony-forming unit/mL (1.09 to 5.94 log colony-forming unit/mL). Forty-five percent of participants reported showering, 49.7% reported swimming while wearing lenses (65.4% of whom swam without goggles), 27.8% used wet hands to handle lenses, and 17.5% used tap water to rinse storage cases. Showering with lenses significantly increased the risk of higher storage case bioburden (P = .001), whereas using wet hands (P = .01) doubled the risk of higher case endotoxin levels (odds ratio, 2.41; confidence interval 1.19 to 4.86). CONCLUSIONS Water contact behavior while wearing lenses is prevalent among soft lens wearers and is associated with higher case contamination. Practitioners may improve contact lens education to reduce water exposure and case contamination to reduce the risk of lens-related adverse events.
Collapse
Affiliation(s)
- Memoona Arshad
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Nicole Carnt
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | - Jacqueline Tan
- School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia
| | | |
Collapse
|
6
|
Mordmuang A, Udomwech L, Karnjana K. Influence of Contact Lens Materials and Cleaning Procedures on Bacterial Adhesion and Biofilm Formation. Clin Ophthalmol 2021; 15:2391-2402. [PMID: 34135567 PMCID: PMC8197623 DOI: 10.2147/opth.s310862] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2021] [Accepted: 05/10/2021] [Indexed: 11/30/2022] Open
Abstract
Purpose The present study aimed to compare the existing soft contact lens (CL) materials regarding their influence on bacterial biofilm formation and adhesion susceptibility. Then, the study was designed to investigate the effectiveness of various disinfecting solutions and evaluate the ability of cleaning regimens in terms of anti-bacterial adhesion and biofilm removal on different soft CL materials. Methods Bacterial biofilm formation on CLs was evaluated by biomass assay. Adhesion assay and standard plate count were carried out at time-interval periods within 24 h. Various CL disinfecting procedures were assessed for their efficacy to remove biofilm and reduce bacterial adhesion. Scanning electron microscopy (SEM) was performed for the morphological assessment of bacterial biofilm. Results Printed hydroxyethyl methacrylate (HEMA) CLs significantly demonstrated more biofilm staining and bacterial attachment when compared with non-printed HEMA CLs, while the Filcon II 3 and Nesofilcon A CLs possessed less biofilm biomass and adherent cells. Staphylococcus aureus and Pseudomonas aeruginosa represented the highest biofilm producing bacteria on HEMA-based materials in this study. The disinfecting regimen with the highest efficacy was the two-step system, first using multipurpose disinfecting solution containing edetate disodium and sorbic acid (MPDS+EDSA), followed by soaking in multipurpose solution (MPS). The regimen demonstrated the greatest effect against the pre-formed biofilm and the adhesion activity of S. aureus and P. aeruginosa on the soft CLs. The SEM micrographs confirmed the morphological changes of bacterial biofilm after disinfecting and revealed that the two-step system treated CLs displayed less adherent bacteria. Conclusion HEMA-based soft CLs may facilitate bacterial biofilm formation and adhesion capability. The two-step system was the most effective regimen for biofilm removal, where the soaking period in the disinfecting solution of the no-rub regimen should last more than 6 h to remove pre-formed biofilm.
Collapse
Affiliation(s)
| | - Lunla Udomwech
- School of Medicine, Walailak University, Nakhon Si Thammarat, Thailand.,Walailak University Hospital, Walailak University, Nakhon Si Thammarat, Thailand
| | - Kulwadee Karnjana
- School of Medicine, Walailak University, Nakhon Si Thammarat, Thailand
| |
Collapse
|
7
|
|
8
|
Adhesion of Stenotrophomonas maltophilia, Delftia acidovorans, and Achromobacter xylosoxidans to Contact Lenses. Eye Contact Lens 2018; 44 Suppl 2:S120-S126. [DOI: 10.1097/icl.0000000000000425] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
9
|
Knowledge, Behavior, and Free-Living Amoebae Contamination of Cosmetic Contact Lens Among University Wearers in Thailand: A Cross-Sectional Study. Eye Contact Lens 2017; 43:81-88. [PMID: 26925535 DOI: 10.1097/icl.0000000000000246] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To assess the general knowledge, behavior, and presence of potentially pathogenic amoebae in cosmetic contact lens (CCL) wearers. METHODS One hundred CCL asymptomatic wearers were randomly selected. A questionnaire regarding their lens use, and a pair of their CCL was obtained. Identification of free-living amoeba (FLA) strains was based on morphological diagnosis, enflagellation tests (for non-Acanthamoeba strains), and sequencing of the small-subunit rRNA gene fragments. RESULTS Most (92%) of the participants surveyed were women, and the average age of the participants was 21.5±0.2 years. The CCL wearers generally showed a moderate (47%) or good (35%) level of knowledge, and good (51%) or excellent (40%) use of CCL. Two CCL samples were positive for Acanthamoeba genotype T3 or Vahlkampfia. The Acanthamoeba-contaminated CCL was from a wearer who used saline for treating lenses, and the Vahlkampfia-contaminated CCL was from a wearer who used CCL while swimming. CONCLUSIONS This is the first report of the presence of potentially pathogenic FLA in used CCL from asymptomatic wearers in Thailand. Although there was satisfactory knowledge and practice of lens care use, the public should be aware of CCL contaminated with potentially pathogenic FLA that can directly or indirectly cause keratitis.
Collapse
|
10
|
|
11
|
Shi GS, Boost MV, Cho P. Does the presence of QAC genes in staphylococci affect the efficacy of disinfecting solutions used by orthokeratology lens wearers? Br J Ophthalmol 2015; 100:708-12. [DOI: 10.1136/bjophthalmol-2015-307811] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2015] [Accepted: 11/26/2015] [Indexed: 11/03/2022]
|
12
|
Sapkota K, Martin R, Franco S, Lira M. Common symptoms of Nepalese soft contact lens wearers: A pilot study. JOURNAL OF OPTOMETRY 2015; 8:200-205. [PMID: 25659748 PMCID: PMC4502082 DOI: 10.1016/j.optom.2015.01.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2014] [Revised: 12/07/2014] [Accepted: 12/27/2014] [Indexed: 06/04/2023]
Abstract
AIM To determine the common symptoms in current soft contact lens (CL) wearers and their association with other factors among Nepalese population. METHODS All the current CL wearers who started to wear soft CL in Nepal Eye Hospital between July 2007 and June 2012 were invited for the participation. Frequency of the ten most common symptoms, divided into never, occasionally, frequently and consistent were recorded. Association between degree of symptoms with other factors, e.g. age, gender, profession, cigarette smoking, ethnicity, level of education and duration and wearing modality of CL wear were analyzed. RESULTS Out of 129 subjects participated in this study, 67% were female; the mean age of the subjects was 23.9±4.3 years. Ninety seven percent of them had at least one symptom occasionally or frequently or consistently. Discomfort was found in 88.4% of the total subjects. Other common symptoms were foreign body sensation in 73.6%, redness in 65.9%, reduced wearing time in 63.6% and dryness in 62.8%. Symptoms were found occasionally in the majority of subjects. Degree of symptoms was not associated with age, gender, profession, education status, ethnicity of subjects and duration or modality of lens wear (p>0.05) but was positively associated with passive cigarette smoking (p<0.001). CONCLUSION Almost all of the Nepalese soft CL wearers had some types of symptoms at least occasionally. Discomfort was the most common symptom. Degree of symptoms was associated with the passive smoking but not with other factors like age, sex, profession and duration of lens wear.
Collapse
Affiliation(s)
- Kishor Sapkota
- Department of Physics, School of Science, University of Minho, Gualtar, Braga, Portugal.
| | - Raul Martin
- IOBA Institute, University of Valladolid, Spain
| | - Sandra Franco
- Department of Physics, School of Science, University of Minho, Gualtar, Braga, Portugal
| | - Madalena Lira
- Department of Physics, School of Science, University of Minho, Gualtar, Braga, Portugal
| |
Collapse
|
13
|
|
14
|
Contact lens wearers' experiences while trekking in the Khumbu region/Nepal: a cross-sectional survey. Travel Med Infect Dis 2014; 13:178-84. [PMID: 25676479 DOI: 10.1016/j.tmaid.2014.12.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2014] [Revised: 12/16/2014] [Accepted: 12/17/2014] [Indexed: 11/23/2022]
Abstract
BACKGROUND Safe contact lens wear depends on a hygiene regime and lens-appropriate wear patterns which may be compromised during travel in remote and wilderness areas. The purpose of this study was to describe the experience of contact lens wearers while trekking at high-altitude in Nepal. METHODS For this descriptive study, trekkers with contact lenses were recruited in Lukla and invited to complete an online-questionnaire on trip preparation, contact lens use, care and experiences, and possible changes for future travel. Quantitative data were analysed using SurveyMonkey; content analysis applied to qualitative responses. RESULTS The majority of the 158 participants (124; 78.48%) reported no problems with their lenses (daily disposables, soft lenses, extended-wear lenses, hard/rigid lenses) during their stay although dry air, dust, wind, cold temperatures, and difficult hygiene maintenance were challenging. Freezing lenses and freezing solutions were additional challenges. Thirty-four (21.52%) experienced a variety of problems. Improvements were requested from manufacturers. Lodges should provide better access to clean water, mirrors and lighting. Almost 60% of participants had not sought any pre-travel health advice. CONCLUSIONS Remote and wilderness areas provide a challenge for appropriate contact lens wear and care. The decision between the potential risk of infection due to touching lenses (daily disposables, soft/hard lenses) and the potential risk of corneal erosion (extended-wear lenses) needs to be made in pre-travel consultations. Travel health professionals and travel agencies should remind CL-wearing trekkers to carefully assess their wear and care routine to accommodate potentially challenging conditions.
Collapse
|