1
|
Peripheral Refraction and Visual Function of Novel Perifocal Ophthalmic Lens for the Control of Myopia Progression. J Clin Med 2023; 12:jcm12041435. [PMID: 36835968 PMCID: PMC9964465 DOI: 10.3390/jcm12041435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Revised: 02/06/2023] [Accepted: 02/08/2023] [Indexed: 02/16/2023] Open
Abstract
This study aimed to evaluate the peripheral defocus induced with a novel perifocal ophthalmic lens for myopia progression control and the potential impact on visual function. This experimental, non-dispensing crossover study evaluated 17 myopic young adults. The peripheral refraction was measured using an open-field autorefractor, at 2.50 m from the target point, in two eccentric points, 25° temporal, 25° nasal, and central vision. Visual contrast sensitivity (VCS) was measured at 3.00 m with a Vistech system VCTS 6500 in low light conditions. Light disturbance (LD) was assessed with a light distortion analyzer 2.00 m away from the device. Peripheral refraction, VCS, and LD were assessed with a monofocal lens and perifocal lens (with an add power of +2.50 D on the temporal side of the lens, and +2.00 D on the nasal side). The results showed that the perifocal lenses induced an average myopic defocus of -0.42 ± 0.38 D (p-value < 0.001) in the nasal retina, at 25° The changes induced by the lower add power in the nasal part of the lens did not induce statistically significant changes in the refraction of the temporal retina. The VCS and LD showed no significant differences between the monofocal and perifocal lenses.
Collapse
|
2
|
Hair LA, Steffensen EM, Berntsen DA. The Effects of Center-near and Center-distance Multifocal Contact Lenses on Peripheral Defocus and Visual Acuity. Optom Vis Sci 2021; 98:983-994. [PMID: 34393205 PMCID: PMC8405543 DOI: 10.1097/opx.0000000000001753] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
SIGNIFICANCE Multifocal contact lenses (MFCLs) are being used clinically for myopia control. Center-distance designs caused myopic changes in defocus across the retina that varied by lens design, whereas the center-near design caused peripheral hyperopic changes. Multifocal lenses caused reductions in low-contrast vision that varied by lens design, affecting visual performance. PURPOSE The purpose of this study was to compare changes in defocus with four MFCLs, three center-distance and one center-near. METHODS Two cohorts of 25 nonpresbyopic myopic adults were enrolled. The first cohort was fitted with Proclear D and Biofinity D MFCL (center-distance, +2.50 D add), and the second cohort was fitted with NaturalVue MFCL (center-distance) and Clariti 1-Day MFCL (center-near, high add), both in random order. Overrefraction was performed to maximize visual acuity. Cycloplegic autorefraction was performed with each lens and without a lens along the line of sight and at nasal and temporal retinal locations out to 40°. Data were analyzed with repeated-measures ANOVAs with post hoc t tests, when indicated. RESULTS Changes in defocus at each location differed between MFCL designs (lens by location; both, P < .001). Clariti 1-Day caused peripheral hyperopic retinal changes (40 and 30° nasal, and 20, 30, and 40° temporal; all, P < .05). NaturalVue MFCL caused myopic changes centrally and hyperopic changes at 40° nasal and 30° temporal (all, P < .05). The remaining center-distance designs caused myopic changes at multiple locations (all, P < .05). CONCLUSIONS After overrefraction, the center-near MFCL design caused hyperopic defocus at multiple peripheral locations, which is not hypothesized to slow myopia progression. NaturalVue MFCL caused myopic changes in defocus centrally but hyperopic changes in the far periphery. Biofinity D and Proclear D caused myopic changes in retinal defocus. Further work is warranted to determine whether defocus profile differences between the center-distance designs influence any slowing of myopia progression.
Collapse
Affiliation(s)
- Lea A Hair
- The Ocular Surface Institute, College of Optometry, University of Houston, Houston, Texas
| | - Elaine M Steffensen
- The Ocular Surface Institute, College of Optometry, University of Houston, Houston, Texas
| | | |
Collapse
|
3
|
Nti AN, Ritchey ER, Berntsen DA. Power profiles of centre-distance multifocal soft contact lenses. Ophthalmic Physiol Opt 2020; 41:393-400. [PMID: 33295033 DOI: 10.1111/opo.12770] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Accepted: 11/13/2020] [Indexed: 02/04/2023]
Abstract
PURPOSE Centre-distance multifocal contact lenses (MFCLs) for myopia control are thought to slow myopia progression by providing both clear foveal vision and myopic defocus. Characterising the power profile of lenses is important to understanding their possible effects on retinal defocus when worn. The power profiles of three commercially available MFCLs were determined. METHODS Three centre-distance MFCL designs were studied: Biofinity Multifocal D +2.50 add (comfilcon A), Proclear Multifocal D +2.50 add (omafilcon A), and NaturalVue Multifocal (etafilcon A). Two lenses each in power from -1.00D to -6.00D in 1D steps were stored in ISO 18369-3:2017 standard phosphate buffered saline for 24 h. Optical power profiles were measured in a wet cell with the SHSOphthalmic profiler accounting for centre thickness and manufacturer-reported material refractive index. Sagittal power maps from the SHSOphthalmic were exported, and custom MATLAB code was used to generate power profiles by averaging along the vertical and horizontal meridians. One-way anova with Tukey's HSD post-hoc t-tests were used to analyse maximum add power by lens design. RESULTS Plus power increased out from the lens centre for all three MFCLs. Power profiles of Biofinity D and Proclear D MFCLs show three distinct areas within the optic zone; the distance zone (from lens centre to about 1.6 mm radius), intermediate zone (about 1.6 mm radius to 2.1 mm) and near zone (about 2 mm radius to 4 mm). For NaturalVue MFCLs, plus power starts increasing almost immediately from the lens centre, reaching maximum measured mean plus power at a radius of 2.7 mm. From 2.7 mm to 3.0 mm, there was a decrease in plus power, which was then generally maintained out to the optic zone edge. Across all lens powers, maximum add power was highest with the NaturalVue MFCL (+3.32 ± 0.44D), then Proclear D (+1.84 ± 0.28D) and Biofinity D (+1.47 ± 0.34D) MFCLs (all p < 0.04). Add power peaked at different locations for different lens powers and designs. CONCLUSIONS Power profiles of MFCLs vary based on lens design and power. These power profiles are consistent with reported myopic and hyperopic changes in peripheral refraction with MFCLs and provide some explanation for reported differences in peripheral refraction with these MFCLs. Further work is needed to determine whether these power profile differences influence myopia progression.
Collapse
Affiliation(s)
- Augustine N Nti
- The Ocular Surface Institute, University of Houston College of Optometry, Houston, USA
| | - Eric R Ritchey
- The Ocular Surface Institute, University of Houston College of Optometry, Houston, USA
| | - David A Berntsen
- The Ocular Surface Institute, University of Houston College of Optometry, Houston, USA
| |
Collapse
|
4
|
Jaisankar D, Liu Y, Kollbaum P, Jaskulski M, Gifford P, Suheimat M, Atchison DA. Nasal-temporal asymmetry in peripheral refraction with an aspheric myopia control contact lens. BIOMEDICAL OPTICS EXPRESS 2020; 11:7376-7394. [PMID: 33409003 PMCID: PMC7747928 DOI: 10.1364/boe.406101] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 10/09/2020] [Accepted: 11/09/2020] [Indexed: 06/12/2023]
Abstract
A combination of human subject data and optical modelling was used to investigate unexpected nasal-temporal asymmetry in peripheral refraction with an aspheric myopia control lens. Peripheral refraction was measured with an auto-refractor and an aberrometer. Peripheral refraction with the lens was highly dependent upon instrument and method (e.g. pupil size and the number of aberration orders). A model that did not account for on-eye conformation did not mirror the clinical results, but a model assuming complete lens conformation to the anterior corneal topography accounted for the positive shift in clinically measured refraction at larger nasal field angles. The findings indicate that peripheral refraction of highly aspheric contact lenses is dependent on lens conformation and the method of measurement. These measurement methods must be reported, and care must be used in interpreting results.
Collapse
Affiliation(s)
- Durgasri Jaisankar
- Centre for Vision and Eye Research, Queensland University of Technology, 60 Musk Avenue, Kelvin Grove, Queensland 4059, Australia
| | - Yongji Liu
- Institute of Modern Optics, Nankai University, 38 Tongyan Road, Haihe Education Park, Tianjin 300350, China
| | - Pete Kollbaum
- School of Optometry, Indiana University, Bloomington, IN 47405, USA
| | - Matt Jaskulski
- School of Optometry, Indiana University, Bloomington, IN 47405, USA
| | - Paul Gifford
- School of Optometry and Vision Science, University of New South Wales, New South Wales, Australia
| | - Marwan Suheimat
- Centre for Vision and Eye Research, Queensland University of Technology, 60 Musk Avenue, Kelvin Grove, Queensland 4059, Australia
| | - David A. Atchison
- Centre for Vision and Eye Research, Queensland University of Technology, 60 Musk Avenue, Kelvin Grove, Queensland 4059, Australia
| |
Collapse
|
5
|
Measurement of the peripheral aberrations of human eyes: A comprehensive review. NANOTECHNOLOGY AND PRECISION ENGINEERING 2020. [DOI: 10.1016/j.npe.2020.05.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
6
|
Jaisankar D, Leube A, Gifford KL, Schmid KL, Atchison DA. Effects of eye rotation and contact lens decentration on horizontal peripheral refraction. Ophthalmic Physiol Opt 2019; 39:370-377. [PMID: 31482609 DOI: 10.1111/opo.12641] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2019] [Accepted: 08/08/2019] [Indexed: 11/30/2022]
Abstract
PURPOSE Peripheral refraction is important in design of myopia control therapies. The aim was to investigate the influence of contact lens decentration associated with eye rotation on peripheral refraction in the horizontal visual field. METHODS Participants were 10 emmetropes and 10 myopes in good general and ocular health. Right eyes underwent cycloplegic peripheral refraction, using a Grand-Seiko WAM-5500 Autorefractor, in 5° steps to ±35° eccentricities along the horizontal visual field. Targets were fixated using eye rotation only or head rotation only. Refractions were measured without correction and with three types of contact lenses: single vision, a multifocal centre-distance aspheric with +2.50 D add and NaturalVue aspheric. Photographs of eyes during lens wear were taken for each eye rotation. Effects of visual field angle, lens type and test method (head or eye rotation) on vector components of relative peripheral refraction were evaluated using repeated measures anovas. Test method for each visual field angle/lens combination were compared via paired t-tests. RESULTS Horizontal decentration ranges across the visual field were 1.2 ± 0.6 mm for single vision and 1.2 ± 0.4 mm for multifocal lenses but smaller at 0.7 ± 0.4 mm for NaturalVue lenses. There were only two significant effects of test method across the visual field angle/lens type combinations (single vision: for emmetropes horizontal/vertical astigmatism component at 35° nasal with mean difference -0.38 D and for myopes spherical equivalent refraction at 20° temporal with mean difference +0.24 D). CONCLUSION Upon eye rotation the contact lenses decentred on the eye, but not enough to affect peripheral refraction. For the types assessed and for the horizontal visual field out to ±35° when measurements were performed with the Grand-Seiko WAM-5500 autorefractor, it is valid to use eye rotations to investigate peripheral refraction.
Collapse
Affiliation(s)
- Durgasri Jaisankar
- Institute of Health & Biomedical Innovation and School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia
| | - Alexander Leube
- Institute for Ophthalmic Research, Eberhard Karls University Tuebingen, Tuebingen, Germany.,Carl Zeiss Vision International GmbH, Aalen, Germany
| | - Kate L Gifford
- Institute of Health & Biomedical Innovation and School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia
| | - Katrina L Schmid
- Institute of Health & Biomedical Innovation and School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia
| | - David A Atchison
- Institute of Health & Biomedical Innovation and School of Optometry and Vision Science, Queensland University of Technology, Brisbane, Australia
| |
Collapse
|
7
|
Ji Q, Yoo YS, Alam H, Yoon G. Through-focus optical characteristics of monofocal and bifocal soft contact lenses across the peripheral visual field. Ophthalmic Physiol Opt 2019; 38:326-336. [PMID: 29691930 DOI: 10.1111/opo.12452] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2017] [Accepted: 03/15/2018] [Indexed: 12/17/2022]
Abstract
PURPOSE To characterise the impact of monofocal soft contact lens (SCL) and bifocal SCLs on refractive error, depth of focus (DoF) and orientation of blur in the peripheral visual field. METHODS Monofocal and two bifocal SCLs, Acuvue Bifocal (AVB, Johnson & Johnson) and Misight Dual Focus (DF, CooperVision) with +2.0 D add power were modelled using a ray tracing program (ZEMAX) based on their power maps. These SCLs were placed onto the anterior corneal surface of the simulated Atchison myopic eye model to correct for -3.0 D spherical refractive error at the fovea. To quantify through-focus retinal image quality, defocus from -3.5 D to 1.5 D in 0.5 D steps was induced at each horizontal eccentricity from 0 to 40° in 10° steps. Wavefront aberrations were computed for each visual eccentricity and defocus. The retinal images were simulated using a custom software program developed in Matlab (The MathWorks) by convolving the point spread function calculated from the aberration with a reference image. The convolved images were spatially filtered to match the spatial resolution limit of each peripheral eccentricity. Retinal image quality was then quantified by the 2-D cross-correlation between the filtered convolved retinal images and the reference image. Peripheral defocus, DoF and orientation of blur were also estimated. RESULTS In comparison with the monofocal SCL, the bifocal SCLs degraded retinal image quality while DoF was increased at fovea. From 10 to 20°, a relatively small amount of myopic shift (less than 0.3 D) was induced by bifocal SCLs compared with monofocal. DoF was also increased with bifocal SCLs at peripheral vision of 10 and 20°. The trend of myopic shift became less consistent at larger eccentricity, where at 30° DF showed a 0.75 D myopic shift while AVB showed a 0.2 D hyperopic shift and both AVB and DF exhibited large relative hyperopic defocus at 40°. The anisotropy in orientation of blur was found to increase and change its direction through focus beyond central vision. This trend was found to be less dominant with bifocal SCLs compared to monofocal SCL. CONCLUSIONS Bifocal SCLs have a relatively small impact on myopic shift in peripheral refractive error while DoF is increased significantly. We hypothetically suggest that a mechanism underlying myopia control with these bifocal or multifocal contact lenses is an increase in DoF and a decrease in anisotropy of peripheral optical blur.
Collapse
Affiliation(s)
- Qiuzhi Ji
- Flaum Eye Institute, The Institute of Optics, Center for Visual Science, University of Rochester, Rochester, USA
| | - Young-Sik Yoo
- Flaum Eye Institute, The Institute of Optics, Center for Visual Science, University of Rochester, Rochester, USA.,Department of Convergence Medical Science, College of Medicine, The Catholic University of Korea, Seoul, South Korea
| | - Hira Alam
- Flaum Eye Institute, The Institute of Optics, Center for Visual Science, University of Rochester, Rochester, USA.,Department of Biology, University of Rochester, Rochester, USA
| | - Geunyoung Yoon
- Flaum Eye Institute, The Institute of Optics, Center for Visual Science, University of Rochester, Rochester, USA
| |
Collapse
|
8
|
Combined Effect of Ocular and Multifocal Contact Lens Induced Aberrations on Visual Performance: Center-Distance Versus Center-Near Design. Eye Contact Lens 2018; 44 Suppl 1:S131-S137. [PMID: 28060146 DOI: 10.1097/icl.0000000000000355] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE To evaluate the combined effects of inherent ocular aberrations and induced aberrations with a multifocal soft contact lens (MFCL) after 15 days of lens wear in presbyopic participants and their influence on visual performance at distance and near under high and low contrast conditions. METHODS Forty presbyopic participants (mean age, 48.7±3.4) presenting a mean addition of 1.53±0.58 D were fitted with Biofinity Multifocal (CooperVision) and included in the study. Measurements comprised distance and near monocular high (100%) and low contrast (10%) logMAR visual acuity (VA). Ocular aberrations were obtained with Hartmann-Shack aberrometer (IRX3, Imagine Eyes) and analyzed for 2 mm and maximum round natural pupil. RESULTS Distance VA was significantly higher in dominant eye, whereas near VA was significantly better in the non-dominant eye (P<0.05 in all conditions). For a 2-mm pupil in the dominant eye fitted with MFCL, spherical-like aberration significantly increased (P=0.027) so as higher-order aberrations (HOA) (P=0.002). A significant increase was also observed in spherical-like aberrations (P=0.001), coma-like aberrations (P=0.006) and HOA (P=0.004) in non-dominant eye. For the maximum round natural pupil size, a significant decrease in vertical coma was observed (P=0.018) in dominant eye, whereas a significant increase in spherical-like (P<0.001) and coma-like aberrations (P=0.007) was observed in non-dominant eye. A negative significant correlation was found between vertical coma and high contrast VA (Rho=-0.405, P=0.011) in dominant eye; whereas in non-dominant eye, a significant correlation was found between induced secondary astigmatism and distance VA under high (Rho=0.556, P<0.001) and low contrast (Rho=0.448, P=0.005). CONCLUSIONS On-eye visual performance of MFSCL is dependent on the high-order aberrations induced by dominant and non-dominant design coupled with the wearer's inherent aberrations.
Collapse
|
9
|
Rodriguez-Vallejo M, Montagud D, Monsoriu JA, Ferrando V, Furlan WD. Relative Peripheral Myopia Induced by Fractal Contact Lenses. Curr Eye Res 2018; 43:1514-1521. [PMID: 30089428 DOI: 10.1080/02713683.2018.1507043] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
PURPOSE To assess the peripheral refraction induced by Fractal Contact Lenses (FCLs) in myopic eyes by means of a two-dimensional Relative Peripheral Refractive Error (RPRE) map. MATERIALS AND METHODS This study involved 26 myopic subjects ranging from -0.50 D to -7.00 D. FCLs prototypes were custom-manufactured and characterized. Corneal topographies were taken in order to assess correlations between corneal asphericity and lens decentration. Two-dimensional RPREs were measured with an open-field autorefractor at 67 points, covering the central 60 × 30 degrees of the visual field. The bidimensional RPRE vector components: M, J0 and J45 of the difference between the values obtained with and without the FCLs in the eye were obtained. Additionally, the FCL-induced peripheral refraction in tangential and sagittal planes was computed along the horizontal meridian. RESULTS Induced by the FCLs, significant differences for all vector components were found in the peripheral retina. FCLs were decentered a mean of 0.7 ± 0.19 mm to the temporal cornea. The two-dimensional RPRE maps manifested the FCLs decentration. In particular, M varied asymmetrically between nasal and temporal retina after fitting the FCLs with a significant increment of the myopic shift beyond 10º (p < 0.05). No correlations were found between the amount of lens decentration and the asphericity of the cornea along temporal and nasal sides. However, significant correlations were found between the corneal asphericity and vector components of the RPRE in naked eyes. FCLs produced an increasing myopic shift in tangential and sagittal power errors along the horizontal meridian. CONCLUSIONS As predicted by ray-tracing simulations, FCLs fitted in myopic eyes produce a myopic shift of the RPRE. The two-dimensional RPRE maps show information about the lens performance that is hidden in the conventional one-dimensional meridional representations.
Collapse
Affiliation(s)
| | - Diego Montagud
- b Centro de Tecnologías Físicas , Universitat Politècnica de València , Valencia , Spain
| | - Juan A Monsoriu
- b Centro de Tecnologías Físicas , Universitat Politècnica de València , Valencia , Spain
| | - Vicente Ferrando
- c Departamento de Óptica , Universitat de València , Burjassot , Spain
| | - Walter D Furlan
- c Departamento de Óptica , Universitat de València , Burjassot , Spain
| |
Collapse
|
10
|
|
11
|
Changes in Peripheral Refraction, Higher-Order Aberrations, and Accommodative Lag With a Radial Refractive Gradient Contact Lens in Young Myopes. Eye Contact Lens 2017; 42:380-387. [PMID: 26808699 DOI: 10.1097/icl.0000000000000222] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
PURPOSE To evaluate changes in the peripheral refraction (PR), visual quality, and accommodative lag with a novel soft radial refractive gradient (SRRG) experimental contact lens that produces peripheral myopic defocus. METHODS 59 myopic right eyes were fitted with the lens. The PR was measured up to 30° in the nasal and temporal horizontal visual fields and compared with values obtained without the lens. The accommodative lag was measured monocularly using the distance-induced condition method at 40 cm, and the higher-order aberrations (HOAs) of the entire eye were obtained for 3- and 5-mm pupils by aberrometry. Visual performance was assessed through contrast sensitivity function (CSF). RESULTS With the lens, the relative PR became significantly less hyperopic from 30° to 15° temporally and 30° nasally in the M and J0 refractive components (P<0.05). Cylinder foci showed significant myopization from 30° to 15° temporally and 30° to 25° nasally (P<0.05). The HOAs increased significantly, the CSF decreased slightly but reached statistical significance for 6 and 12 cycles per degree (P<0.05), and the accommodative lag decreased significantly with the SRRG lens (P=0.0001). There was a moderate correlation between HOAs and CSF at medium and high spatial frequencies. CONCLUSION The SRRG lens induced a significant change in PR, particularly in the temporal retina. Tangential and sagittal foci changed significantly in the peripheral nasal and temporal retina. The decreased accommodative lag and increased HOAs particularly in coma-like aberration may positively affect myopia control. A longitudinal study is needed to confirm this potential.
Collapse
|
12
|
Queirós A, Lopes-Ferreira D, González-Méijome JM. Astigmatic Peripheral Defocus with Different Contact Lenses: Review and Meta-Analysis. Curr Eye Res 2016; 41:1005-1015. [DOI: 10.3109/02713683.2015.1116585] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
13
|
|