1
|
Alexander J, Belaineh Aweke Y, Bhebhe Z, Cho D, Lay S, Ryan I, Collins MJ, Vincent SJ. The effect of landing zone toricity on scleral lens fitting characteristics and optics. Ophthalmic Physiol Opt 2024; 44:867-875. [PMID: 38699941 DOI: 10.1111/opo.13324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2024] [Revised: 04/10/2024] [Accepted: 04/18/2024] [Indexed: 05/05/2024]
Abstract
PURPOSE The fit and optical performance of a scleral lens is affected by the alignment of the landing zone with the underlying ocular surface. The aim of this research was to quantify the effect of landing zone toricity upon scleral lens fitting characteristics (rotation and decentration) and optics (lens flexure) during short-term wear. METHODS Scleral lenses with nominal landing zone toricities of 0, 100, 150 and 200 μm were worn in a randomised order by 10 young healthy participants (mean [SD] 24 [7] years) for 30 min, with other lens parameters held constant. Scleral toricity was quantified using a corneo-scleral profilometer, and lens flexure, rotation, and decentration were quantified using over-topography during lens wear. Repeated measures analyses were conducted as a function of landing zone toricity and residual scleral toricity (the difference between scleral and lens toricity) for eyes with 'low' magnitude scleral toricity (mean: 96 μm) and 'high' magnitude scleral toricity (mean: 319 μm). RESULTS Toric landing zones significantly reduced lens flexure (by 0.37 [0.21] D, p < 0.05) and lens rotation (by 20 [24]°, p < 0.05) compared with a spherical landing zone. Horizontal and vertical lens decentration did not vary significantly with landing zone toricity. These trends for flexure, rotation, and decentration were also observed for eyes with 'low' and 'high' magnitude scleral toricity as a function of residual scleral toricity. CONCLUSION Landing zones with 100-200 μm toricity significantly reduced lens flexure (by ~62%) and rotation (by ~77%) but not horizontal or vertical lens decentration, compared with a spherical landing zone, when controlling for other confounding variables. The incorporation of a toric landing zone, even for eyes with lower magnitude scleral toricity (~100 μm), may be beneficial, particularly for front surface optical designs.
Collapse
Affiliation(s)
- Julian Alexander
- Optometry & Vision Science, Centre for Vision & Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Yabkal Belaineh Aweke
- Optometry & Vision Science, Centre for Vision & Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Zibonele Bhebhe
- Optometry & Vision Science, Centre for Vision & Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia
| | - David Cho
- Optometry & Vision Science, Centre for Vision & Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Steven Lay
- Optometry & Vision Science, Centre for Vision & Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Isaac Ryan
- Optometry & Vision Science, Centre for Vision & Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Michael J Collins
- Optometry & Vision Science, Centre for Vision & Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Stephen J Vincent
- Optometry & Vision Science, Centre for Vision & Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia
| |
Collapse
|
2
|
Macedo-de-Araújo RJ, Amorim-de-Sousa A, González-Méijome JM. Influence of midday removal and re-application of a scleral lens on fluid reservoir thickness, pre-lens tear film quality and visual acuity. Cont Lens Anterior Eye 2024:102250. [PMID: 38897843 DOI: 10.1016/j.clae.2024.102250] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2024] [Revised: 05/13/2024] [Accepted: 06/05/2024] [Indexed: 06/21/2024]
Abstract
PURPOSE To investigate whether the midday removal and re-application of scleral lenses (SL) influences fluid reservoir (FR) thickness, pre-lens tear film quality and visual acuity. METHODS Two clinical experiments were conducted. A total of 49 keratoconic eyes were evaluated for Part1(tear film and visual acuity analysis) and 12 keratoconic eyes for Part2 (FR thickness analysis). All subjects were wearing 16.4 mm SL for more than 12-months. Tear Film Surface Quality (TFSQ) was evaluated with Medmont E300 at more than 120 min of SL wear, 10 min after SL removal (pre-corneal TFSQ) and 5 min after re-apply the same SL. High and Low Contrast Visual Acuity (HCVA and LCVA) were also assessed with the SL on eye (before and after re-application). For Part2, Anterior OCT (MOptim MOcean4000, China) measurements were taken with and without the SL (at the same time points of Part1) and three outcomes were evaluated: FR thickness, SL thickness (control measurement) and corneal thickness. RESULTS Removing and re-applying a SL had a statistically significant positive impact on TFSQ, with an improvement from 0.26 ± 011 to 0.16 ± 0.08 (p = 0.001). This was accompanied by a statistically significant improvement in LogMAR HCVA (from 0.10 ± 0.09 to 0.08 ± 0.08, p < 0.001) and LCVA (from 0.39 ± 0.13 to 0.36 ± 0.13, p < 0.001). Regarding Part2 of the study, a statistically significant increase in FR thickness was observed after SL re-application (from 223.64 ± 48.08 µm to 267.81 ± 80.03 µm, p = 0.007). No changes in corneal thickness were observed. CONCLUSIONS Midday removal and re-application of a scleral lens positively impacted pre-lens tear film surface quality, although the observed improvement in visual acuity does not constitute a clinically significant change. Clinicians should consider that removing and reapplying a scleral lens may result in an overestimation of the fluid reservoir thickness, which could affect clinical assessments and treatment decisions.
Collapse
Affiliation(s)
- Rute J Macedo-de-Araújo
- Clinical & Experimental Optometry Research Lab (CEORLab), University of Minho, Braga, Portugal; Physics Center of Minho and Porto Universities (CF-UM-UP), University of Minho, Braga, Portugal.
| | - Ana Amorim-de-Sousa
- Clinical & Experimental Optometry Research Lab (CEORLab), University of Minho, Braga, Portugal; Physics Center of Minho and Porto Universities (CF-UM-UP), University of Minho, Braga, Portugal
| | - José M González-Méijome
- Clinical & Experimental Optometry Research Lab (CEORLab), University of Minho, Braga, Portugal; Physics Center of Minho and Porto Universities (CF-UM-UP), University of Minho, Braga, Portugal
| |
Collapse
|
3
|
Craig JP, Barsam A, Chen C, Chukwuemeka O, Ghorbani-Mojarrad N, Kretz F, Michaud L, Moore J, Pelosini L, Turnbull AMJ, Vincent SJ, Wang MTM, Ziaei M, Wolffsohn JS. BCLA CLEAR Presbyopia: Management with corneal techniques. Cont Lens Anterior Eye 2024:102190. [PMID: 38851946 DOI: 10.1016/j.clae.2024.102190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/10/2024]
Abstract
Corneal techniques for enhancing near and intermediate vision to correct presbyopia include surgical and contact lens treatment modalities. Broad approaches used independently or in combination include correcting one eye for distant and the other for near or intermediate vision, (termed monovision or mini-monovision depending on the degree of anisometropia) and/or extending the eye's depth of focus [1]. This report provides an overview of the evidence for the treatment profile, safety, and efficacy of the range of corneal techniques currently available for managing presbyopia. The visual needs and expectations of the patient, their ocular characteristics, and prior history of surgery are critical considerations for patient selection and preoperative evaluation. Contraindications to refractive surgery include unstable refraction, corneal abnormalities, inadequate corneal thickness for the proposed ablation depth, ocular and systemic co-morbidities, uncontrolled mental health issues and unrealistic patient expectations. Laser refractive options for monovision include surface/stromal ablation techniques and keratorefractive lenticule extraction. Alteration of spherical aberration and multifocal ablation profiles are the primary means for increasing ocular depth of focus, using surface and non-surface laser refractive techniques. Corneal inlays use either small aperture optics to increase depth of field or modify the anterior corneal curvature to induce corneal multifocality. Presbyopia correction by conductive keratoplasty involves application of radiofrequency energy to the mid-peripheral corneal stroma which leads to mid-peripheral corneal shrinkage, inducing central corneal steepening. Hyperopic orthokeratology lens fitting can induce spherical aberration and correct some level of presbyopia. Postoperative management, and consideration of potential complications, varies according to technique applied and the time to restore corneal stability, but a minimum of 3 months of follow-up is recommended after corneal refractive procedures. Ongoing follow-up is important in orthokeratology and longer-term follow-up may be required in the event of late complications following corneal inlay surgery.
Collapse
Affiliation(s)
- Jennifer P Craig
- Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand; College of Health & Life Sciences, Aston University, Birmingham, UK.
| | | | - Connie Chen
- Department of Optometry, Chung Shan Medical University, Taichung City, Taiwan
| | - Obinwanne Chukwuemeka
- Cornea, Contact Lens and Myopia Management Unit, De-Lens Ophthalmics Family and Vision Care Centre, Abuja, Nigeria
| | - Neema Ghorbani-Mojarrad
- School of Optometry and Vision Science, University of Bradford, Bradford, UK; Wolfson Centre for Applied Health Research, Bradford Royal Infirmary, Bradford, UK
| | | | | | | | | | - Andrew M J Turnbull
- Royal Bournemouth Hospital, University Hospitals Dorset, UK; Faculty of Life and Health Sciences, Ulster University, UK
| | - Stephen J Vincent
- Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Australia
| | - Michael T M Wang
- Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Mohammed Ziaei
- Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - James S Wolffsohn
- Department of Ophthalmology, Aotearoa New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand; College of Health & Life Sciences, Aston University, Birmingham, UK
| |
Collapse
|
4
|
Walker MK, Lema C, Redfern R. Potential pro-inflammatory impact of scleral lens midday fogging on human corneal epithelial cells: An in vitro study. Cont Lens Anterior Eye 2024:102187. [PMID: 38762441 DOI: 10.1016/j.clae.2024.102187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 03/31/2024] [Accepted: 05/11/2024] [Indexed: 05/20/2024]
Abstract
PURPOSE Midday fogging (MDF) occurs when particulate material accumulates in the fluid reservoir (FR) beneath scleral lenses (SL), and its impact on epithelial cells is unknown. This study examines the in vitro pro-inflammatory effect of the FR on human corneal epithelial cells in varying degrees of MDF. METHODS Normal SL neophytes were recruited to wear SL 8 h daily for 4 days. Following 8 h on days 1 and 4, optical coherence tomography (OCT) images were acquired for MDF quantification using ImageJ, and the FR was collected. FR samples from the same eye were later pooled, diluted 2-fold and applied on human telomerase-immortalized corneal epithelial (hTCEpi) cells cultured on Terasaki microwell plates. Tumor necrosis factor (TNF)-α and culture media were used as positive and negative controls, respectively. After a 30-minute treatment, the nuclear factor-kappa B (NF-κB) pathway was measured by NF-κB-p65 immunofluorescence and images were analyzed with ImageJ. Pearson's correlation was conducted to determine the association between median nuclear fluorescence and MDF. RESULTS Fourteen FR samples with a mean volume of 22 ± 16 µl were tested. Mean MDF severity following 8 h of SL wear was 25 ± 17 units (range 7 - 64). The median nuclear fluorescence (NF-κB-p65 translocation) in cultured hTCEpi cells ranged from 31.43 to 45.16 while the negative and positive controls were 44.71 ± 1.72 and 108.77 ± 68.38, respectively. Although a potential positive trend between MDF and median nuclear fluorescence was observed, Pearson's correlation analysis revealed no significant association (r = +0.48, P = 0.09). CONCLUSIONS The results suggest that the FR can trigger NF-κB-p65 translocation in hTCEpi cells, which may be associated with MDF severity. This study introduces the use of Terasaki microwell plates for immunofluorescence studies of the FR. The technique is simple, minimizes sample usage, and does not require expensive instrumentation.
Collapse
Affiliation(s)
- Maria K Walker
- University of Houston, College of Optometry, The Ocular Surface Institute (TOSI), United States.
| | - Carolina Lema
- University of Houston, College of Optometry, The Ocular Surface Institute (TOSI), United States; University of Texas Health Science Center at Houston, Center for Clinical and Translational Sciences (CCTS), United States
| | - Rachel Redfern
- University of Houston, College of Optometry, The Ocular Surface Institute (TOSI), United States
| |
Collapse
|
5
|
Morgan PB, Efron N, Papas E, Barnett M, Carnt N, Dutta D, Hepworth A, Little JA, Nagra M, Pult H, Schweizer H, Shen Lee B, Subbaraman LN, Sulley A, Thompson A, Webster A, Markoulli M. BCLA CLEAR Presbyopia: Management with contact lenses and spectacles. Cont Lens Anterior Eye 2024:102158. [PMID: 38631935 DOI: 10.1016/j.clae.2024.102158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/19/2024]
Abstract
This paper seeks to outline the history, market situation, clinical management and product performance related to the correction of presbyopia with both contact lenses and spectacles. The history of the development of various optical forms of presbyopic correction are reviewed, and an overview is presented of the current market status of contact lenses and spectacles. Clinical considerations in the fitting and aftercare of presbyopic contact lens and spectacle lens wearers are presented, with general recommendations for best practice. Current options for contact lens correction of presbyopia include soft simultaneous, rigid translating and rigid simultaneous designs, in addition to monovision. Spectacle options include single vision lenses, bifocal lenses and a range of progressive addition lenses. The comparative performance of both contact lens and spectacle lens options is presented. With a significant proportion of the global population now being presbyopic, this overview is particularly timely and is designed to act as a guide for researchers, industry and eyecare practitioners alike.
Collapse
Affiliation(s)
- Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, United Kingdom.
| | - Nathan Efron
- Optometry and Vision Science, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Eric Papas
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | | | - Nicole Carnt
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Debarun Dutta
- Optometry and Vision Science Research Group, Aston University, Birmingham, United Kingdom
| | - Andy Hepworth
- EssilorLuxottica Europe North, Bristol, United Kingdom
| | - Julie-Anne Little
- Centre for Optometry and Vision Science, Biomedical Sciences Research Institute, Ulster University, Coleraine, United Kingdom
| | - Manbir Nagra
- Vision and Eye Research Institute, ARU, Young Street, Cambridge, United Kingdom
| | - Heiko Pult
- Dr Heiko Pult - Optometry and Vision Research, Weinheim, Germany
| | - Helmer Schweizer
- CEO Helmer Schweizer Consulting Group (HSCG), Bassersdorf, Switzerland
| | - Bridgitte Shen Lee
- Vision Optique and Ocular Aesthetics dba Ocular Clinical Trials, Houston, TX, United States
| | | | - Anna Sulley
- CooperVision International Ltd, Chandlers Ford, United Kingdom
| | | | | | - Maria Markoulli
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
6
|
Shorter E, Nau CB, Fogt JS, Nau A, Schornack M, Harthan J. Patient Experiences With Therapeutic Contact Lenses and Dry Eye Disease. Eye Contact Lens 2024; 50:59-64. [PMID: 37910817 PMCID: PMC10843105 DOI: 10.1097/icl.0000000000001051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/10/2023] [Indexed: 11/03/2023]
Abstract
OBJECTIVES To report patient-reported experiences with dry eye disease and therapeutic contact lenses. METHODS A survey was distributed to patients with dry eye disease. Demographics, Ocular Surface Disease Index (OSDI), systemic disease, contact lens history, and burden of care information were collected. Descriptive statistics are presented and categorized by nonlens, soft lens, and scleral lens (SL) wearers. RESULTS Of 639 respondents, 15% (94/639) were currently using therapeutic soft or SLs (47 soft and 69 SL). Mid-day fogging or clouding of vision was reported by SL (75%, 50/67) and soft lens (62%, 29/47) wearers. Seventy-two percent of SL wearers spent more than 20 min daily on dry eye treatment while 43% of soft lens wearers spent more than 20 min. Median annual expenditure was higher for SL ($1,500, n=63) than nonlens ($500, n=371) or soft lens wearers ($700, n=43). Mean OSDI scores in all groups were in the severe category (51±22 years, n=401 nonlens wearers; mean age; 45±22 years, n=47 soft lens wearers; 60±24 years, n=69 SL wearers). CONCLUSIONS Mid-day fogging and blurring of vision was reported by most of the individuals using therapeutic lenses for dry eye disease. SL wearers allocate the most resources for dry eye care.
Collapse
Affiliation(s)
- Ellen Shorter
- University of Illinois at Chicago, Chicago, Illinois
| | | | | | - Amy Nau
- Korb and Associates, Boston, Massachusetts
| | | | | |
Collapse
|
7
|
Wolffsohn JS. 2022 Glenn A. Fry Award lecture: Enhancing clinical assessment for improved ophthalmic management. Optom Vis Sci 2024; 101:12-24. [PMID: 38350054 DOI: 10.1097/opx.0000000000002102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2024] Open
Abstract
ABSTRACT Detailed clinical assessment is critical to allow sensitive evaluation of the eye and its management. As technology advances, these assessment techniques can be adapted and refined to improve the detection of pathological changes of ocular tissue and their impact on visual function. Enhancements in optical medical devices including spectacle, contact, and intraocular lenses have allowed for a better understanding of the mechanism and amelioration of presbyopia and myopia control. Advancements in imaging technology have enabled improved quantification of the tear film and ocular surface, informing diagnosis and treatment strategies. Miniaturized electronics, large processing power, and in-built sensors in smartphones and tablets capacitate more portable assessment tools for clinicians, facilitate self-monitoring and treatment compliance, and aid communication with patients. This article gives an overview of how technology has been used in many areas of eye care to improve assessments and treatment and provides a snapshot of some of my studies validating and using technology to inform better evidence-based patient management.
Collapse
|
8
|
Costa D, De Matteis V, Treso F, Montani G, Martino M, Rinaldi R, Corrado M, Cascione M. Impact of the physical properties of contact lens materials on the discomfort: role of the coefficient of friction. Colloids Surf B Biointerfaces 2024; 233:113630. [PMID: 37956592 DOI: 10.1016/j.colsurfb.2023.113630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/31/2023] [Accepted: 11/01/2023] [Indexed: 11/15/2023]
Abstract
Contact Lens Discomfort (CLD) is the main cause in contact lens (CLs) discontinuation, referred in literature as drop-out phenomenon. Despite such evidence was reported in several clinical studies, a relationship between physico-chemical properties of CLs and CLD is not still totally understood. In this regard, the friction of CLs surfaces seems to be related to discomfort feeling events, probably due to an alteration of the lubricate function of the tear film after the CL placement inside the ocular environment. In the last years, many studies have been finalized to the friction measurements of CLs surface, finding conflicting data due to a lack in standardized protocol. The aim of this review is primarily to show evident relationships between CLs surface properties (i.e. wettability, tear evaporation, tear film quality, etc.) and the coefficient of friction (CoF), resulting therefore the most relevant physical quantity in the CLs characterization. In addition, we reported the most recent studies in CLs tribology, which highlight that the introduction of a standard protocol in CoF measurements is necessary to obtain reproducible results, considering the aim to evaluate in a more precise way the relationship between this material surface property and comfort in CLs users.
Collapse
Affiliation(s)
- D Costa
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy
| | - V De Matteis
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy.
| | - F Treso
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - G Montani
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - M Martino
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - R Rinaldi
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy
| | - M Corrado
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy
| | - M Cascione
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy.
| |
Collapse
|
9
|
Yuan W, Zhao F, Liu X, Xu J. Development of corneal contact lens materials and current clinical application of contact lenses: A review. Biointerphases 2023; 18:050801. [PMID: 37756594 DOI: 10.1116/6.0002618] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 08/31/2023] [Indexed: 09/29/2023] Open
Abstract
Unlike conventional glasses, corneal contact lenses (CLs) can directly contact the surface of the tear film through the application of biopolymer materials, to achieve therapeutic and cosmetic purposes. Since the advent of polymethylmethacrylate, a material that has gained widespread use and attention, statistically, there are now more than 150 × 106 people around the world who wear corneal contact lenses. However, the associated complications caused by the interaction of contact lenses with the ocular surface, tear film, endogenous and environmental microorganisms, and components of the solution affect nearly one-third of the wearer population. The application of corneal contact lenses in correcting vision and myopia control has been widely recognized. With the development of related materials, corneal contact lenses are applied to the treatment of ocular surface diseases, including corneal bandage lenses, drug-loaded corneal contact lenses, biosensors, and other new products, while minimizing the side effects associated with CL wear. This paper summarized the development history and material properties of CLs, focused on the current main clinical applications and mechanisms, as well as clarified the possible complications in wearing therapeutic contact lenses and the direction for improvement in the future.
Collapse
Affiliation(s)
- Weichen Yuan
- Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, Shenyang 110005, China
| | - Fangkun Zhao
- Department of Ophthalmology, The Fourth Affiliated Hospital of China Medical University, Shenyang 110005, China
| | - Xiaoyu Liu
- Department of Ophthalmology, Dalian Third People's Hospital Affiliated to Dalian Medical University, Dalian 116033, China
| | - Jun Xu
- Department of Ophthalmology, Dalian Third People's Hospital Affiliated to Dalian Medical University, Dalian 116033, China
| |
Collapse
|
10
|
Yang Z, Wang M, Li Z, Hu Y, Jiang J, Yu F, Zeng J, Chen W, Yang X. Repeatability and Reproducibility of Corneoscleral Topography Measured With Scheimpflug Imaging in Keratoconus and Control Eyes. Eye Contact Lens 2023; 49:234-240. [PMID: 36989487 DOI: 10.1097/icl.0000000000000983] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/13/2022] [Indexed: 03/31/2023]
Abstract
OBJECTIVES To determine and compare the repeatability and reproducibility of anterior scleral parameters measured by the corneoscleral profile (CSP) module of Pentacam in keratoconus (KC) and control eyes. METHODS This is a prospective observational study. Thirty KC participants (30 eyes) and 24 control participants (24 eyes) were examined three times using the CSP. Sagittal height mean (SHM), sagittal height astigmatism (SHA), and mean bulbar slope (BSM) were measured in 12 mm and 16 mm chord lengths. The repeatability and reproducibility of these measurements were also assessed. Coefficients of variation (CoV), intraclass correlation coefficient (ICC), coefficient of repeatability (CoR1), and coefficient of reproducibility (CoR2) were adopted to assess the reliability. RESULTS In the KC and control groups, SHM showed high repeatability and reproducibility (coefficients of variation [CoVs]≤0.96%, intraclass correlation coefficient [ICCs]≥0.97), and SHM of control eyes showed higher repeatability and reproducibility than that of KC eyes at 12 mm chord length (KC group, CoRs ranged from 35.56 μm to 43.52 μm, control group, ranged from 23.50 μm to 30.31 μm) and 16 mm chord length (KC group, CoRs ranged from 79.54 μm to 81.58 μm, control group, ranged from 48.25 μm to 66.10 μm). Mean bulbar slope also showed high repeatability and reproducibility (CoVs≤3.65%, CoRs≤2.64). Furthermore, the SHA of control eyes showed higher repeatability and reproducibility when compared with KC eyes (control group: CoVs≤29.95%, KC group: CoVs≥32.67%). CONCLUSIONS Keratoconus and control eyes demonstrated high repeatability and reproducibility when using CSP measurements, which may prove helpful in fitting contact lenses.
Collapse
Affiliation(s)
- Zhengfei Yang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou, China
| | | | | | | | | | | | | | | | | |
Collapse
|
11
|
Asghari B, Brocks DC. Early Postoperative Therapeutic Scleral Lens Intervention for Penetrating Keratoplasty Complications in Atopic Keratoconjunctivitis. Eye Contact Lens 2023; 49:254-257. [PMID: 37167589 DOI: 10.1097/icl.0000000000000997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/28/2023] [Indexed: 05/13/2023]
Abstract
ABSTRACT A 52-year-old white man with keratoconus and severe atopic keratoconjunctivitis underwent penetrating keratoplasty (PK) for visual rehabilitation in the left eye. Post-PK complications included a persistent epithelial defect. Therapeutic scleral lens wear was initiated 2 weeks post-PK. Customizations were incorporated into the lens design to prevent suction and corneal hypoxia during lens wear. Post-PK herpes epithelial keratitis developed shortly thereafter, causing recurrence of a nonhealing epithelial defect. The patient was treated with oral antiviral therapy, discontinuation of dupilumab, and daily waking-hour scleral lens wear, which was used as an antibiotic drug delivery device. The cornea fully epithelialized, and best-corrected visual acuity improved to 20/40-2. The patient continued with daily waking-hour scleral lens wear and was without recurrence of persistent epithelial defect or herpes keratitis at 18 months. No scleral lens-related complications were observed despite the unconventional early intervention with a therapeutic scleral lens.
Collapse
|
12
|
Yoshikawa Y, Ueta M, Kinoshita S, Kida T, Sotozono C. Long-Term Benefits of Tear Exchangeable Limbal-Rigid Contact Lens Wear Therapy in Stevens-Johnson Syndrome Cases. Eye Contact Lens 2023; 49:247-253. [PMID: 37053071 PMCID: PMC10513020 DOI: 10.1097/icl.0000000000000989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/11/2023] [Indexed: 04/14/2023]
Abstract
OBJECTIVES To evaluate the long-term benefits of tear-exchangeable, limbal-rigid contact lens (CL) wear therapy in patients with Stevens-Johnson syndrome (SJS)-associated ocular sequelae. METHODS This retrospective study evaluated 50 eyes of 41 SJS patients (15 men and 26 women) who underwent limbal-rigid CL wear therapy for more than 2 years post fitting. Ocular sequelae (i.e., conjunctival hyperemia, corneal neovascularization, and upper tarsus scarring) before fitting and at 3 months, 6 months, 12 months, and annually after initiating CL wear therapy were evaluated and then graded on a severity score (range: 0-3, maximum score: 3). Moreover, visual acuity (VA) at immediately post initiating CL wear therapy was evaluated. RESULTS The mean follow-up period was 4.3±1.1 years. Compared with before fitting, the mean conjunctival hyperemia score improved from 1.14 to 0.86 at 3 months of CL wear therapy ( P <0.01) and was maintained thereafter; the mean corneal neovascularization score improved from 2.10 to 1.98 at 3 months of CL wear therapy, with no deterioration of the score observed in all cases at the final follow-up examination, and mean VA (log of minimum angle of resolution) improved from 1.60 to 1.04 at immediately post initiating CL wear therapy ( P <0.01). CONCLUSIONS Limbal-rigid CL wear therapy can provide long-term ocular surface stabilization and improved VA in SJS patients.
Collapse
Affiliation(s)
- Yamato Yoshikawa
- Department of Ophthalmology (Y.Y., T.K), Osaka Medical and Pharmaceutical University, Takatsuki-City, Osaka; Department of Ophthalmology (Y.Y., C.S.), Kyoto Prefectural University of Medicine, Kyoto; and Department of Frontier Medical Science and Technology for Ophthalmology (U.M., S.K.), Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Mayumi Ueta
- Department of Ophthalmology (Y.Y., T.K), Osaka Medical and Pharmaceutical University, Takatsuki-City, Osaka; Department of Ophthalmology (Y.Y., C.S.), Kyoto Prefectural University of Medicine, Kyoto; and Department of Frontier Medical Science and Technology for Ophthalmology (U.M., S.K.), Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Shigeru Kinoshita
- Department of Ophthalmology (Y.Y., T.K), Osaka Medical and Pharmaceutical University, Takatsuki-City, Osaka; Department of Ophthalmology (Y.Y., C.S.), Kyoto Prefectural University of Medicine, Kyoto; and Department of Frontier Medical Science and Technology for Ophthalmology (U.M., S.K.), Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Teruyo Kida
- Department of Ophthalmology (Y.Y., T.K), Osaka Medical and Pharmaceutical University, Takatsuki-City, Osaka; Department of Ophthalmology (Y.Y., C.S.), Kyoto Prefectural University of Medicine, Kyoto; and Department of Frontier Medical Science and Technology for Ophthalmology (U.M., S.K.), Kyoto Prefectural University of Medicine, Kyoto, Japan
| | - Chie Sotozono
- Department of Ophthalmology (Y.Y., T.K), Osaka Medical and Pharmaceutical University, Takatsuki-City, Osaka; Department of Ophthalmology (Y.Y., C.S.), Kyoto Prefectural University of Medicine, Kyoto; and Department of Frontier Medical Science and Technology for Ophthalmology (U.M., S.K.), Kyoto Prefectural University of Medicine, Kyoto, Japan
| |
Collapse
|
13
|
Bergmann B, Wolffsohn JS, Bandlitz S. Scheimpflug imaging for grading and measurement of corneo-scleral-profile in different quadrants. Cont Lens Anterior Eye 2023; 46:101753. [PMID: 36030150 DOI: 10.1016/j.clae.2022.101753] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 08/15/2022] [Accepted: 08/16/2022] [Indexed: 11/03/2022]
Abstract
PURPOSE The corneo-scleral-profile (CSP) describes the transition from cornea to sclera, while the corneo-scleral junction angle (CSJ), is the angle formed between the cornea and the sclera. The aims of this study were (i) to analyse the CSP and CSJ in different quadrants and (ii) to test correlation and repeatability of an established observational grading and measurement method, using Scheimpflug images. METHODS The nasal, temporal, superior and inferior CSP of 35 healthy eye participants (mean age 25.5 SD ± 3.1 years; 20 female) was imaged using the corneo-scleral-profile module of the Pentacam (Oculus, Wetzlar, Germany). On the captured Scheimpflug images CSP was subjectively graded into five different corneo-scleral transitions, using the Meier grading scale (profile 1 fluid-convex; profile 2 fluid-tangential; profile 3 marked-convex; profile 4 marked-tangential; profile 5 concave). The CSJ was measured on the same images using ImageJ v1.8.0. Grading and measurement was repeated at a second session. Intra-observer reliability for the CSP-grading was analysed by Cohen's Kappa. Differences between repeated CSJ-measurements and different quadrants were analysed by paired-t-test and ANOVA. The eta-coefficient was used to determine the association between subjective CSP-grading and CSJ-measurement. RESULTS Intra-observer reliability for the CSP grading system was poor (kappa = 0.098) whereas repeated measurements of CSJ angle showed no statistically significant difference between sessions (0.04°; 95 % CI - 0.21° to 0.29°; p = 0.77). CSJ angles ranged from 172° to 180° with no statistically significant differences between nasal, temporal, superior and inferior (p = 0.24). Eta-coefficient indicated a weak association between CSP-grading and CSJ-measurement (η = 0.27; p = 0.04). CONCLUSIONS The subjective CSP-grading showed poorer repeatability than the objective CSJ-measurement, which did not detect any differences in angles between the meridians. The weak association between CSP-grading and CSJ-measurement is likely caused by the limited intra-observer reliability of the Meier grading scale. Furthermore, the CSP-grading scale seems to consider other aspects beside the CSJ angle, such as scleral radius.
Collapse
Affiliation(s)
- Benjamin Bergmann
- Höhere Fachschule für Augenoptik Köln, Cologne School of Optometry, Cologne, Germany
| | - James S Wolffsohn
- School of Health and Life Sciences, Aston University, Birmingham, United Kingdom
| | - Stefan Bandlitz
- Höhere Fachschule für Augenoptik Köln, Cologne School of Optometry, Cologne, Germany; School of Health and Life Sciences, Aston University, Birmingham, United Kingdom.
| |
Collapse
|
14
|
Naroo SA, Eperjesi F, Woods C, Zeri F. Evidence based care is derived from good evidence-based teaching and learning. Cont Lens Anterior Eye 2023; 46:101823. [PMID: 36863933 DOI: 10.1016/j.clae.2023.101823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Affiliation(s)
- Shehzad A Naroo
- College of Health and Life Sciences, Aston University, UK; International Association of Contact Lens Educators, Canada.
| | | | - Craig Woods
- School of Optometry and Vision Science, University of New South Wales, Australia; International Association of Contact Lens Educators, Canada
| | - Fabrizio Zeri
- College of Health and Life Sciences, Aston University, UK; University of Milano-Bicocca, Department of Materials Science, Milan, Italy; International Association of Contact Lens Educators, Canada
| |
Collapse
|
15
|
Schornack MM, Vincent SJ, Walker MK. Anatomical and physiological considerations in scleral lens wear: Intraocular pressure. Cont Lens Anterior Eye 2023; 46:101535. [PMID: 34824016 DOI: 10.1016/j.clae.2021.101535] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Revised: 10/29/2021] [Accepted: 11/02/2021] [Indexed: 02/06/2023]
Abstract
Intraocular pressure (IOP) is maintained through complex and interrelated systems which control aqueous production and drainage, and it has been suggested that scleral lens (SL) wear may disrupt these vital homeostatic processes. This review provides an overview of anatomical and physiological processes that control IOP, identifies potential effects of SLs on these regulatory mechanisms, and examines studies that have attempted to quantify the effect of SLs on IOP. Lack of access to the cornea during SL wear makes accurate assessment of IOP challenging; therefore, a range of different assessment techniques and instruments have been employed to quantify IOP during and following SL wear. Some studies have evaluated IOP using standard techniques prior to lens application and following lens removal, or through a large central fenestration. Other studies have utilised instruments that facilitate assessment of IOP on the peripheral cornea or conjunctiva overlying the sclera (e.g. Schiotz, transpalpebral, and pneumatonometry). Two studies have recently evaluated changes in optic nerve structure during SL wear. Conflicting results have been reported on this topic, much of which examines changes in IOP in healthy subjects over limited periods of time. Currently, only a few studies have reported on long-term effects of SL wear on IOP in habitual SL wearers (after lens removal). Future research in this area must not only consider the fact that ocular conditions treated with SLs may potentially alter corneal biomechanical properties which can influence IOP, but also that these properties may be further altered by SL wear. Monitoring other risk factors for glaucoma (permanent alterations in optic nerve physiology, visual field defects) could provide a more comprehensive assessment of potentially increased risk of glaucomatous optic neuropathy due to SL wear. Ongoing clinical assessment of optic nerve structure and function is advisable in patients at risk for glaucoma who require SLs.
Collapse
Affiliation(s)
| | - Stephen J Vincent
- Queensland University of Technology (QUT), Centre for Vision and Eye Research, School of Optometry and Vision Science, Contact Lens and Visual Optics Laboratory, Queensland, Australia.
| | - Maria K Walker
- University of Houston College of Optometry, The Ocular Surface Institute, Houston, TX, USA.
| |
Collapse
|
16
|
García-Marqués JV, Macedo-De-Araújo RJ, Cerviño A, García-Lázaro S, González-Méijome JM. Assessment of meibomian gland drop-out and visibility through a new quantitative method in scleral lens wearers: A one-year follow-up study. Cont Lens Anterior Eye 2023; 46:101571. [PMID: 34996711 DOI: 10.1016/j.clae.2021.101571] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2021] [Revised: 11/29/2021] [Accepted: 12/30/2021] [Indexed: 01/18/2023]
Abstract
OBJECTIVES To validate a previously developed algorithm based on the visibility of meibomian gland images obtained with Cobra fundus camera and to assess the changes in meibomian glands in scleral lens wearers over one year of lens wear. METHODS Infrared meibography was obtained from the upper eyelid using the Cobra fundus camera in forty-three volunteers (34.2 ± 10.1 years). Meibographies were classified into 3 groups: Group 1 = good subjective gland visibility and gland drop-out < 1/3 of the total area; Group 2 = low visibility and gland drop-out < 1/3; and Group 3 = low visibility and gland drop-out > 1/3. Meibomian gland visibility metrics were then calculated using the developed algorithm from the pixel intensity values of meibographies. Repeatability of new metrics and their correlations with gland drop-out were assessed. Meibographies and ocular symptoms were also assessed after 1 year of scleral lens wear in 29 subjects. RESULTS Gland drop-out percentage was not statistically different between groups 1 and 2 (p = 0.464). Nevertheless, group 1 showed higher grey pixel intensity values than the other groups. Statistically significant correlations were found between gland visibility metrics and gland drop-out percentage. Repeatability was acceptable for all metrics, coefficient of variation achieving values between 0.52 and 3.18. While ocular symptoms decreased with scleral lens wear (p < 0.001), no statistically significant differences were found in gland drop-out percentage (p = 0.157) and gland visibility metrics (p > 0.217). CONCLUSIONS The proposed method can assess meibomian gland visibility in an objective and repeatable way. Scleral lens wear appears to not adversely affect meibomian gland drop-out and visibility while might improve dry eye symptoms after one year of lens wear. These preliminary results should be confirmed with a control group.
Collapse
Affiliation(s)
| | - Rute Juliana Macedo-De-Araújo
- Clinical and Experimental Optometry Research Laboratory (CEORLab) Center of Physics (Optometry), School of Sciences, University of Minho, Braga, Portugal
| | - Alejandro Cerviño
- Department of Optics and Optometry and Vision Sciences. University of Valencia, Burjassot, Spain
| | - Santiago García-Lázaro
- Department of Optics and Optometry and Vision Sciences. University of Valencia, Burjassot, Spain
| | - Jose Manuel González-Méijome
- Clinical and Experimental Optometry Research Laboratory (CEORLab) Center of Physics (Optometry), School of Sciences, University of Minho, Braga, Portugal
| |
Collapse
|
17
|
Specialty lens science. Cont Lens Anterior Eye 2023; 46:101796. [PMID: 36564252 DOI: 10.1016/j.clae.2022.101796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
18
|
Harrop K, Beerten R, Steenbekkers G, Voltz K, Johnson L, Siergey J. Foreword - Why specialist lenses? Cont Lens Anterior Eye 2023; 46:101797. [PMID: 36566122 DOI: 10.1016/j.clae.2022.101797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
19
|
Deboutte I, Kreps EO, Rozema JJ, van Hoey M, Anthonissen L, Koppen C. Influence of Specialty Contact Lens Wear on Posterior Corneal Tomography in Keratoconus Subjects. Eye Contact Lens 2022; 48:497-502. [PMID: 36137997 DOI: 10.1097/icl.0000000000000941] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 08/04/2022] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To evaluate the effect of specialty contact lens (CL) wear on posterior corneal tomography in keratoconus subjects. METHODS Patients with keratoconus who were wearing specialty CL were included in this retrospective cohort study. Tomographic parameters were evaluated with Scheimpflug imaging (Pentacam HR) before lens fitting and immediately after removal of CLs worn habitually for a period of several months. Subjects were divided into groups, according to type of lens (corneal, scleral, and hybrid) and keratoconus severity based on Belin/Ambrosio D (BAD-D) score, for further analysis. RESULTS Thirty-four eyes of 34 subjects diagnosed with keratoconus were included. Mean duration of habitual CL wear was 7.0±0.3 months. For the entire cohort, a small increase in flat keratometric reading at the anterior corneal surface (K1F; P =0.032) and at the posterior surface (K1B; P =0.041) was found. In the corneal CL group (10 eyes; 29.4%), flattening of the anterior corneal curvature was detected (K max ; P =0.015). An increase in K1B value was seen in the scleral CL group (15 eyes; 44.1%) ( P =0.03). Combined topometric indices showed a small but significant difference in the entire cohort ( P <0.05) and in the subgroups of corneal CL wear and of moderate keratoconus (BAD-D score≥7). CONCLUSION Various types of specialty CLs exert a differential influence on corneal parameters. A small steepening of keratometry at the posterior surface (K1B) was observed in the scleral lens group. Although corneal lens wear flattens the anterior cornea (K max ), it does not significantly alter the posterior corneal surface.
Collapse
Affiliation(s)
- Isabel Deboutte
- Department of Ophthalmology (I.D., J.R., M.H., L.A., C.K.), Antwerp University Hospital, Edegem, Belgium ; Department of Ophthalmology (E.O.K.), Ghent University Hospital, Ghent, Belgium ; and Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences (J.R., C.K.), University of Antwerp, Antwerp, Belgium
| | | | | | | | | | | |
Collapse
|
20
|
Novel High-Resolution Imaging Using ANTERION Optical Coherence Tomography to Assess Fluid Reservoir Change in Scleral Lens Periphery. Eye Contact Lens 2022; 48:466-470. [PMID: 36083177 DOI: 10.1097/icl.0000000000000937] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/01/2022] [Indexed: 02/04/2023]
Abstract
OBJECTIVES To assess scleral lens fluid reservoir (FR) change simultaneously in four quadrants with single acquisition using novel ANTERION anterior segment swept-source optical coherence tomography (SS-OCT). METHODS A prospective, observational, clinical study of 18 subjects (30 eyes) was performed on adults fitted with a scleral lens for ocular surface disease (n=8), irregular cornea/scar (n=7), and corneal ectasia (n=15). ANTERION anterior segment SS-OCT imaging was obtained at the initial visit and at the follow-up to determine pre and post scleral lens settling, measured in microns, centrally and peripherally. Peripheral measurements were grouped into four quadrants. Repeated-measures ANOVA was performed comparing vault post minus pre differences by quadrant, and TTests comparing difference in FR by lens design were performed with a significant threshold at P <0.05. RESULTS The mean central scleral lens settling was significant at -48.3±41.7 μm. The change in FR by quadrant was superior (S): -47.8±67.3 μm, inferior (I): -68.0±102.2 μm, nasal (N) -46.3±63.4 μm, and temporal (T): -56.7±49.3 μm. There were no significant differences in lens settling between the quadrants. Within the three categories, the irregular cornea group experienced significantly greater lens settling. There was no significant difference in central FR when comparing lens design or lens diameter. CONCLUSIONS The ANTERION SS-OCT allows for high-resolution central and peripheral assessment of FR in scleral lens wear. With increased technology available for scleral lens customization, this imaging modality can assist in more detailed assessment in quadrant-specific scleral lens designs.
Collapse
|
21
|
Aziza Y, Itoi M, Ueta M, Inatomi T, Kinoshita S, Sotozono C. Limbal-Rigid Contact Lens Wear for the Treatment of Ocular Surface Disorders: A Review. Eye Contact Lens 2022; 48:313-317. [PMID: 35877181 PMCID: PMC9298148 DOI: 10.1097/icl.0000000000000924] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/31/2022] [Indexed: 11/27/2022]
Abstract
ABSTRACT Recently, the prescription of large-diameter rigid gas-permeable contact lenses (CLs), also known as "scleral lenses," "corneoscleral lenses," and "limbal-rigid CLs," is on the rise for the treatment of both moderate and severe ocular surface disorders (OSDs). Compared with scleral lenses, the diameter of limbal-rigid CLs is generally smaller, that is, a diameter ranging from 13.0 to 14.0 mm, and they are designed so that the peripheral edge bears on the limbus. The Suncon Kyoto-CS (Sun Contact Lens Co., Ltd.) is a novel limbal-rigid CL design with multistep curves on the peripheral edge for easy tear exchange during blinking that removes debris and prevents lens clouding or fogging, thus allowing patients to enjoy a longer daily duration of CL wear. In severe OSD cases, limbal-rigid CL wear after surgery is a noninvasive therapeutic approach that can neutralize corneal irregularities, decrease dry eye symptoms, prevent the progression or recurrence of symblepharon, and improve the patient's visual acuity and overall quality of life. Thus, surgeries such as amniotic membrane transplantation and cultivated oral mucosal epithelial transplantation, as well as limbal-rigid CL wear, which is noninvasive, are valuable and effective treatment strategies that can now be applied for the management of patients afflicted with severe OSDs.
Collapse
Affiliation(s)
- Yulia Aziza
- Department of Ophthalmology (Y.A., M.I., M.U., T.I., C.S.), Kyoto Prefectural University of Medicine, Kyoto, Japan; Department of Ophthalmology (T.I.), National Center for Geriatrics and Gerontology, Aichi, Japan; and Department of Frontier Medical Science and Technology for Ophthalmology (S.K.), Kyoto Prefectural University of Medicine, Kyoto, Japan
| | | | | | | | | | | |
Collapse
|
22
|
Wang Y, Jacobs DS. Role of therapeutic contact lenses in management of corneal disease. Curr Opin Ophthalmol 2022; 33:306-310. [PMID: 35779054 DOI: 10.1097/icu.0000000000000859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE OF REVIEW The current review highlights areas of innovation and research in the use of contact lenses in the treatment of corneal ectasia and ocular surface disease. RECENT FINDINGS A series of academic reports were published by a committee of experts reviewing evidence-based practice patterns of contact lens use. There continues to be active research in the use of contact lenses in the management of keratoconus, including mini-scleral lenses, custom impression-based scleral lenses and wavefront-guided scleral lenses. Recent reports on contact lenses for ocular surface disease were primarily reviews, retrospective case reports or case series, with publications on contact lens use in corneal epithelial defects, graft-vs.-host disease, limbal stem cell deficiency and neurotrophic keratitis. There are recent publications on advances in drug-eluting contact lenses. SUMMARY Corneal specialists should be aware of current advances in the field of contact lens expanding their use in corneal ectasia and ocular surface disease.
Collapse
Affiliation(s)
- Yvonne Wang
- Department of Ophthalmology, Yale School of Medicine, New Haven, Connecticut
| | - Deborah S Jacobs
- Department of Ophthalmology, Massachusetts Eye and Ear, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
23
|
Bandlitz S, Lagodny M, Kurz C, Wolffsohn JS. Anterior ocular surface sagittal height prediction. Ophthalmic Physiol Opt 2022; 42:1023-1031. [PMID: 35703419 DOI: 10.1111/opo.13017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2022] [Revised: 05/16/2022] [Accepted: 05/16/2022] [Indexed: 11/29/2022]
Abstract
PURPOSE To investigate the validity of Placido-based corneal topography parameters to predict corneoscleral sagittal heights measured by Fourier-based profilometry at various diameters. METHODS Minimal (Minsag ), maximal (Maxsag ) sagittal height, toricity (Maxsag - Minsag ) and axis of the flattest meridian (Minsag ) of 36 subjects (mean age 25.4 SD ± 3.2 years; 21 female) were measured using the Eye Surface Profiler and analysed for diameters (chord length) of 8 to 16 mm (in 2-mm intervals). Furthermore, corneal central radii, corneal astigmatism, eccentricity and diameter were measured using the Keratograph 5 M. RESULTS Using multiple linear regression analysis, the best equation for predicting the sagittal heights for 8 mm (r2 = 0.95), and 10 mm (r2 = 0.93) diameters included corneal central radii and eccentricity. The best equation for predicting sagittal heights for 12 mm (r2 = 0.86), 14 mm (r2 = 0.78) and 16 mm (r2 = 0.65) diameters included corneal central radii, eccentricity and corneal diameter. Corneal astigmatism was significantly correlated with sagittal height toricity for 8 and 10 mm diameters (r2 = 0.50 and 0.29; p < 0.01), while no correlation was observed for 12, 14 and 16 mm diameters (p = 0.18 to p = 0.76). The axis of the flattest corneal meridian measured by Placido-based topography was significantly correlated with the axis of the flattest meridian measured by Fourier-based profilometry for 8, 10 and 12 mm diameters (r2 = 0.17 to 0.44; p < 0.05), while there was no correlation for 14 and 16 mm diameters (p = 0.48 and p = 0.75). For a typical soft contact lens diameter of 14 mm, 78% of the variance could be determined with a corneal topographer and 68% with keratometry and corneal diameter measurement. CONCLUSIONS The combination of corneal central radii, eccentricity and corneal diameter measured by Placido-based topography is a valid predictor of the corneoscleral sagittal height in healthy eyes. Scleral toricity and axis of the flattest meridian seem to be independent from Placido-based corneal parameters and requires additional measuring tools.
Collapse
Affiliation(s)
- Stefan Bandlitz
- Höhere Fachschule für Augenoptik Köln (Cologne School of Optometry), Cologne, Germany.,School of Life and Health Sciences, Aston University, Birmingham, UK
| | - Matthias Lagodny
- Höhere Fachschule für Augenoptik Köln (Cologne School of Optometry), Cologne, Germany
| | - Corinna Kurz
- Höhere Fachschule für Augenoptik Köln (Cologne School of Optometry), Cologne, Germany
| | - James S Wolffsohn
- School of Life and Health Sciences, Aston University, Birmingham, UK
| |
Collapse
|
24
|
Kumar M, Shetty R, Lalgudi VG, Roy AS, Khamar P, Vincent SJ. Corneal Biomechanics and Intraocular Pressure Following Scleral Lens Wear in Penetrating Keratoplasty and Keratoconus. Eye Contact Lens 2022; 48:206-209. [PMID: 35333810 DOI: 10.1097/icl.0000000000000886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/11/2021] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To compare corneal biomechanics and intraocular pressure (IOP) in keratoconus and penetrating keratoplasty eyes before and after nonfenestrated scleral lens wear. METHODS Twenty-three participants were enrolled, and 37 eyes were included in the analysis (11 penetrating keratoplasty and 26 keratoconus). A range of corneal biomechanical parameters and IOP were measured using the CORVIS ST before and after 8 hr of nonfenestrated scleral lens wear (Keracare, Acculens, Denver, CO). RESULTS Before lens wear, penetrating keratoplasty eyes displayed significantly greater median values for central corneal thickness (97 μm thicker, P=0.02), IOP (3.89 mm Hg higher, P=0.01), and biomechanical parameter A2 length (0.48 mm longer, P=0.003) compared with keratoconic eyes. No significant changes in corneal biomechanical parameters or IOP were observed after scleral lens wear in either group (all P>0.05). CONCLUSION Although nonfenestrated scleral contact lenses can induce a subatmospheric pressure after lens settling and compress tissue surrounding the limbus, no significant changes were detected in the corneal biomechanical parameters studied using CORVIS ST after scleral lens wear in eyes with penetrating keratoplasty and keratoconus.
Collapse
Affiliation(s)
- Mukesh Kumar
- Narayana Nethralaya (M.K., R.S., V.G.L., A.S.R., P.K.), Bangalore, India; and Centre for Vision and Eye Research (S.J.V.), School of Optometry & Vision Science, Queensland University of Technology, Brisbane, Australia
| | | | | | | | | | | |
Collapse
|
25
|
Fisher D, Collins MJ, Vincent SJ. Scleral Lens Thickness and Corneal Edema Under Closed Eye Conditions. Eye Contact Lens 2022; 48:194-199. [PMID: 35580359 DOI: 10.1097/icl.0000000000000852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/12/2021] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To examine the relationship between central lens thickness and central corneal edema during short-term closed eye scleral lens wear. METHODS Nine participants (mean age 30 years) with normal corneas wore scleral lenses (Dk 141) under closed eye conditions on separate days with nominal center thicknesses of 150, 300, 600, and 1,200 μm. Epithelial, stromal, and total corneal edema were measured using high-resolution optical coherence tomography immediately after lens application and after 90 min of wear, before lens removal. Data were corrected for variations in initial fluid reservoir thickness and compared with predictions from theoretical modeling of overnight scleral lens wear. RESULTS Scleral lens-induced central corneal edema was primarily stromal in nature. The mean±standard error of corrected total corneal edema was 4.31%±0.32%, 4.55%±0.42%, 4.92%±0.50%, and 4.83%±0.22% for the 150-, 300-, 600-, and 1,200-μm lenses, respectively. No significant differences in the corrected total corneal edema were observed across all thickness groups (P=0.20). Theoretical modeling of overnight scleral lens wear seemed to overestimate the relative increase in central corneal edema as a function of decreasing lens Dk/t for values lower than 25. CONCLUSION The magnitude of scleral lens-induced central corneal edema during short-term closed eye lens wear did not vary significantly with increasing central lens thickness. Theoretical modeling of overnight closed eye scleral lens wear seems to overestimate the effect of increasing lens thickness.
Collapse
Affiliation(s)
- Damien Fisher
- Contact Lens and Visual Optics Laboratory, School of Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Australia
| | | | | |
Collapse
|
26
|
Macedo-de-Araújo RJ, Fadel D, Barnett M. How Can We Best Measure the Performance of Scleral Lenses? Current Insights. CLINICAL OPTOMETRY 2022; 14:47-65. [PMID: 35418790 PMCID: PMC9000539 DOI: 10.2147/opto.s284632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 03/24/2022] [Indexed: 06/14/2023]
Abstract
Scleral lenses (SLs) present several unique advantageous characteristics for patients. As these lenses are mainly fitted in severely diseased eyes, a thorough evaluation of the ocular surface before and after SL fitting and the on-eye SL fitting evaluation are essential and help minimize potential physiological complications. This review will explore the current and emerging techniques and instrumentation to best measure SL performance ensuring optimal lens fitting, visual quality, comfort and physiological responses, highlighting some potential complications and follow-up recommendations. A single physician could perform the great majority of evaluations. Still, the authors consider that the assessment of SL fitting should be a collaborative and multidisciplinary job, involving contact lens practitioners, ophthalmologists and the industry. This publication has reviewed the most up-to-date work and listed the most used techniques; however, the authors encourage the development of more evidence-based recommendations for SL clinical practice.
Collapse
Affiliation(s)
- Rute J Macedo-de-Araújo
- Clinical & Experimental Optometry Research Laboratory (CEORLab), Physics Centre of Minho and Porto Universities (CF-UM-UP), University of Minho, Braga, Portugal
| | | | - Melissa Barnett
- Davis Eye Center, University of California, Sacramento, CA, USA
| |
Collapse
|
27
|
Corneal Response to Scleral Contact Lens Wear in Keratoconus. Eye Contact Lens 2022; 48:322-327. [PMID: 35389370 DOI: 10.1097/icl.0000000000000899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/20/2022] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To verify corneal alterations in patients with keratoconus who wear scleral contact lenses (ScCLs), focusing on corneal endothelial assessment. METHODS Scleral contact lenses were fitted in 22 patients with keratoconus. During a 90-day follow-up, patients were assessed in three visits: at baseline, after 30 days, and after 90 days. Patients underwent visual acuity measurement, slitlamp biomicroscopy of the anterior segment, specular microscopy of the corneal endothelium, corneal pachymetry, measurement of the clearance between the cornea and the lens, and follow-up of ectasia. RESULTS Variables related to endothelial morphology and pachymetry values did not change significantly over time. Central clearance measurements decreased in the 90-day period. No progression of corneal ectasia was observed, neither were infectious or inflammatory processes in the same period. CONCLUSION Daily wear of ScCLs in patients with keratoconus was not associated with adverse effects on the cornea or endothelium over a period of 90 days nor was there evidence of disease progression. Central clearance values diminished over that period, but the significance of this observation remains unclear.
Collapse
|
28
|
Contact lens prescribing trends in the UK hospital eye service. Cont Lens Anterior Eye 2022; 45:101594. [DOI: 10.1016/j.clae.2022.101594] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 03/28/2022] [Accepted: 03/29/2022] [Indexed: 11/19/2022]
|
29
|
Asghari B, Brocks D, Carrasquillo KG, Crowley E. OSDI Outcomes Based on Patient Demographic and Wear Patterns in Prosthetic Replacement of the Ocular Surface Ecosystem. CLINICAL OPTOMETRY 2022; 14:1-12. [PMID: 35046743 PMCID: PMC8760101 DOI: 10.2147/opto.s337920] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 12/18/2021] [Indexed: 05/26/2023]
Abstract
PURPOSE To evaluate the impact of prosthetic replacement of the ocular surface ecosystem (BostonSight PROSE) treatment on symptom outcomes based on the Ocular Surface Disease Index (OSDI). PATIENTS AND METHODS This was a single-center, retrospective analysis of consecutive patients who initiated PROSE treatment between September 2017 and December 2019 by the same clinician. The primary outcome measure was to compare OSDI survey scores at baseline prior to PROSE treatment and at follow-up, after PROSE treatment. Indication for treatment, sex, age, device diameter, average wear time, preexisting mental illness, duration of PROSE wear, and status of PROSE wear at follow-up were also studied. RESULTS A total of 134 patients underwent PROSE treatment and completed a baseline OSDI survey during the study period. Forty-three patients completed a follow-up OSDI survey and were included in the study analysis. The most common treatment indications were keratoconjunctivitis sicca (n=27) and corneal ectasia (n=16). Baseline average OSDI score was 56.9±23.7 for the 43 subjects who completed a subsequent OSDI survey. The last documented average follow-up OSDI for those 43 subjects was 23.8±15.6, median (IQR) of 22.9 (10.4 to 32.3), and a statistically significant 54.7±27.6% average improvement from baseline (p<0.01). All patients, except for two, showed improvement in OSDI score. Statistically significant improvement occurred regardless of underlying diagnosis with no statistically significant difference based on age, sex, mental illness, or device diameter and no statistical correlation with average wear time, or duration of PROSE wear. CONCLUSION PROSE treatment improves visual function and symptom relief as demonstrated by the OSDI survey. Sex, age, preexisting mental illness, device diameter, average wear time, and duration of wear had no statistically significant impact on OSDI outcomes.
Collapse
|
30
|
Bligdon SM, Colarusso BA, Ganjei AY, Kwok A, Luo ZK, Brocks D. Scleral Lens and Prosthetic Replacement of the Ocular Surface Ecosystem Utilization in Ocular Graft-versus-Host Disease: A Survey Study. Clin Ophthalmol 2022; 15:4829-4838. [PMID: 34992343 PMCID: PMC8717734 DOI: 10.2147/opth.s337824] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Accepted: 12/01/2021] [Indexed: 12/31/2022] Open
Abstract
Purpose To evaluate the utilization of scleral lenses and prosthetic replacement of the ocular surface ecosystem devices (SL/PDs) in the management of ocular graft-versus-host disease (oGVHD). Patients and Methods A survey of 15 questions was sent via email to 6032 subjects registered with the Blood and Marrow Transplant Information Network. The survey reviewed transplant history, graft-versus-host disease history, as well as oGVHD symptoms and onset. Additional questions surveyed treatments used for oGVHD, as well as the degree of ocular symptom control and experience with SL/PDs. A total of 306 respondents met the eligibility requirements to be part of the analyzed cohort. Results The mean number of symptoms reported from the analyzed cohort was 4.79 ± 2.44, median (IQR) of 5.0 (3.0 to 7.0), with the most common symptom being gritty, dry eyes (87%). The mean number of treatments utilized across the analyzed cohort was 3.21 ± 2.55, median (IQR) of 2.5 (1.0 to 5.0), with the most common treatment being artificial tears (86%). Wearing scleral lenses resulted in a mean of 5.42 ± 1.86, median (IQR) of 6.0 (4.0 to 7.0) symptoms improving, with improved dryness/grittiness of the eyes (94%), improved eye pain (92%) and improved quality of life (89%) being the most commonly improved symptoms. Fifty-six percent of those wearing scleral lenses wished the lenses had been recommended sooner. The most common reason patients cited for not wearing scleral lenses was that they had never heard of them (63%). Conclusion SL/PDs help to control the symptoms of oGVHD. With their use, clinicians are able to improve the quality of life of this patient population. Despite the known benefits, SL/PDs still remain underutilized in oGVHD care. A majority of current SL/PD wearers wish that they had been recommended sooner as a treatment option. SL/PDs should be considered a component of comprehensive oGVHD management.
Collapse
Affiliation(s)
| | | | - Allen Y Ganjei
- Drexel University College of Medicine, Philadelphia, PA, USA
| | | | | | | |
Collapse
|
31
|
Erdinest N, London N, Levinger N. Letter to the Editor Concerning "Common Ophthalmic Preservatives in Soft Contact Lens Care Products: Benefits, Complications, and a Comparison to Non-Preserved Solutions" [Letter]. CLINICAL OPTOMETRY 2021; 13:301-302. [PMID: 34707423 PMCID: PMC8544787 DOI: 10.2147/opto.s342043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Grants] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Accepted: 10/11/2021] [Indexed: 06/13/2023]
Affiliation(s)
- Nir Erdinest
- Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel
| | | | - Nadav Levinger
- Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel
- Department of Ophthalmology, Enaim Refractive Surgery Center, Jerusalem, Israel
| |
Collapse
|
32
|
Vincent SJ. Scleral lens issues and complications: their recognition, etiology, and management. Clin Exp Optom 2021. [DOI: 10.1080/08164622.2021.1914512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022] Open
Affiliation(s)
- Stephen J Vincent
- School of Optometry and Vision Science, Queensland University of Technology Brisbane, Brisbane, Australia,
| |
Collapse
|
33
|
CLEAR - Contact lens wettability, cleaning, disinfection and interactions with tears. Cont Lens Anterior Eye 2021; 44:157-191. [DOI: 10.1016/j.clae.2021.02.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
|
34
|
CLEAR - Contact lens complications. Cont Lens Anterior Eye 2021; 44:330-367. [DOI: 10.1016/j.clae.2021.02.010] [Citation(s) in RCA: 29] [Impact Index Per Article: 9.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Accepted: 02/01/2021] [Indexed: 12/20/2022]
|
35
|
Wolffsohn JS, Dumbleton K, Huntjens B, Kandel H, Koh S, Kunnen CME, Nagra M, Pult H, Sulley AL, Vianya-Estopa M, Walsh K, Wong S, Stapleton F. CLEAR - Evidence-based contact lens practice. Cont Lens Anterior Eye 2021; 44:368-397. [PMID: 33775383 DOI: 10.1016/j.clae.2021.02.008] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 12/15/2022]
Abstract
Evidence-based contact lens -->practice involves finding, appraising and applying research findings as the basis for patient management decisions. These decisions should be informed by the strength of the research study designs that address the question, as well as by the experience of the practitioner and the preferences and environment of the patient. This reports reviews and summarises the published research evidence that is available to inform soft and rigid contact lens history and symptoms taking, anterior eye health examination (including the optimised use of ophthalmic dyes, grading scales, imaging techniques and lid eversion), considerations for contact lens selection (including the ocular surface measurements required to select the most appropriate lens parameter, lens modality and material selection), evaluation of lens fit, prescribing (teaching self-application and removal, adaptation, care regimen and cleaning instructions, as well as -->minimising risks of lens wear through encouraging compliance) and an aftercare routine.
Collapse
Affiliation(s)
| | - Kathy Dumbleton
- School of Optometry, University of California, Berkeley, CA, USA
| | - Byki Huntjens
- Division of Optometry and Visual Sciences at City, University of London, London, UK
| | - Himal Kandel
- Save Sight Institute, Sydney Medical School, The University of Sydney, Sydney, Australia
| | - Shizuka Koh
- Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Japan
| | | | - Manbir Nagra
- Vision and Eye Research Institute, ARU, Cambridge, UK
| | - Heiko Pult
- Optometry and Vision Research, Weinheim, Germany
| | | | - Marta Vianya-Estopa
- Department of Vision and Hearing Sciences Research Centre, Anglia Ruskin University, Cambridge, UK
| | - Karen Walsh
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Stephanie Wong
- Centre for Ocular Research & Education, School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
36
|
Wolffsohn JS, Morgan PB, Barnett M, Downie LE, Jacobs DS, Jones L, Richdale K, Stapleton F, Vincent SJ, Willcox M. Contact Lens Evidence-Based Academic Reports (CLEAR). Cont Lens Anterior Eye 2021; 44:129-131. [PMID: 33775374 DOI: 10.1016/j.clae.2021.02.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2021] [Accepted: 02/01/2021] [Indexed: 12/30/2022]
Affiliation(s)
| | - Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, UK
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Australia
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Cornea and Refractive Surgery Service, Boston, MA, USA; Harvard Medical School, Boston, MA, USA
| | - Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada; Centre for Eye and Vision Research (CEVR), Hong Kong
| | | | - Fiona Stapleton
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| | - Stephen J Vincent
- Queensland University of Technology (QUT), Centre for Vision and Eye Research, School of Optometry and Vision Science, Contact Lens and Visual Optics Laboratory, Brisbane, Australia
| | - Mark Willcox
- School of Optometry and Vision Science, University of New South Wales, Sydney, NSW, Australia
| |
Collapse
|
37
|
Jacobs DS, Carrasquillo KG, Cottrell PD, Fernández-Velázquez FJ, Gil-Cazorla R, Jalbert I, Pucker AD, Riccobono K, Robertson DM, Szczotka-Flynn L, Speedwell L, Stapleton F. CLEAR - Medical use of contact lenses. Cont Lens Anterior Eye 2021; 44:289-329. [PMID: 33775381 DOI: 10.1016/j.clae.2021.02.002] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Accepted: 02/01/2021] [Indexed: 12/11/2022]
Abstract
The medical use of contact lenses is a solution for many complex ocular conditions, including high refractive error, irregular astigmatism, primary and secondary corneal ectasia, disfiguring disease, and ocular surface disease. The development of highly oxygen permeable soft and rigid materials has extended the suitability of contact lenses for such applications. There is consistent evidence that bandage soft contact lenses, particularly silicone hydrogel lenses, improve epithelial healing and reduce pain in persistent epithelial defects, after trauma or surgery, and in corneal dystrophies. Drug delivery applications of contact lens hold promise for improving topical therapy. Modern scleral lens practice has achieved great success for both visual rehabilitation and therapeutic applications, including those requiring retention of a tear reservoir or protection from an adverse environment. This report offers a practical and relevant summary of the current evidence for the medical use of contact lenses for all eye care professionals including optometrists, ophthalmologists, opticians, and orthoptists. Topics covered include indications for use in both acute and chronic conditions, lens selection, patient selection, wear and care regimens, and recommended aftercare schedules. Prevention, presentation, and management of complications of medical use are reviewed.
Collapse
Affiliation(s)
- Deborah S Jacobs
- Massachusetts Eye & Ear, Cornea and Refractive Surgery Service, Harvard Medical School, Boston, MA, USA.
| | | | | | | | | | | | | | | | | | - Loretta Szczotka-Flynn
- Department of Ophthalmology & Visual Science, Case Western Reserve University, Cleveland, OH, USA
| | - Lynne Speedwell
- Great Ormond Street Hospital for Children NHS Trust, Moorfields Eye Hospital, London, UK
| | - Fiona Stapleton
- School of Optometry and Vision Science, UNSW Sydney, Australia
| |
Collapse
|
38
|
Jones L, Hui A, Phan CM, Read ML, Azar D, Buch J, Ciolino JB, Naroo SA, Pall B, Romond K, Sankaridurg P, Schnider CM, Terry L, Willcox M. CLEAR - Contact lens technologies of the future. Cont Lens Anterior Eye 2021; 44:398-430. [PMID: 33775384 DOI: 10.1016/j.clae.2021.02.007] [Citation(s) in RCA: 33] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 12/20/2022]
Abstract
Contact lenses in the future will likely have functions other than correction of refractive error. Lenses designed to control the development of myopia are already commercially available. Contact lenses as drug delivery devices and powered through advancements in nanotechnology will open up further opportunities for unique uses of contact lenses. This review examines the use, or potential use, of contact lenses aside from their role to correct refractive error. Contact lenses can be used to detect systemic and ocular surface diseases, treat and manage various ocular conditions and as devices that can correct presbyopia, control the development of myopia or be used for augmented vision. There is also discussion of new developments in contact lens packaging and storage cases. The use of contact lenses as devices to detect systemic disease has mostly focussed on detecting changes to glucose levels in tears for monitoring diabetic control. Glucose can be detected using changes in colour, fluorescence or generation of electric signals by embedded sensors such as boronic acid, concanavalin A or glucose oxidase. Contact lenses that have gained regulatory approval can measure changes in intraocular pressure to monitor glaucoma by measuring small changes in corneal shape. Challenges include integrating sensors into contact lenses and detecting the signals generated. Various techniques are used to optimise uptake and release of the drugs to the ocular surface to treat diseases such as dry eye, glaucoma, infection and allergy. Contact lenses that either mechanically or electronically change their shape are being investigated for the management of presbyopia. Contact lenses that slow the development of myopia are based upon incorporating concentric rings of plus power, peripheral optical zone(s) with add power or non-monotonic variations in power. Various forms of these lenses have shown a reduction in myopia in clinical trials and are available in various markets.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong.
| | - Alex Hui
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia
| | - Chau-Minh Phan
- Centre for Ocular Research & Education (CORE), School of Optometry & Vision Science, University of Waterloo, Waterloo, Canada; Centre for Eye and Vision Research (CEVR), 17W Hong Kong Science Park, Hong Kong
| | - Michael L Read
- Eurolens Research, Division of Pharmacy and Optometry, Faculty of Biology, Medicine and Health, The University of Manchester, Manchester, UK
| | - Dimitri Azar
- Department of Ophthalmology and Visual Sciences, University of Illinois College of Medicine, Chicago, IL, USA; Verily Life Sciences, San Francisco, CA, USA
| | - John Buch
- Johnson & Johnson Vision Care, Jacksonville, FL, USA
| | - Joseph B Ciolino
- Department of Ophthalmology, Massachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA
| | - Shehzad A Naroo
- College of Health and Life Sciences, Aston University, Birmingham B4 7ET, UK
| | - Brian Pall
- Johnson & Johnson Vision Care, Jacksonville, FL, USA
| | - Kathleen Romond
- Department of Ophthalmology and Visual Sciences, University of Illinois College of Medicine, Chicago, IL, USA
| | - Padmaja Sankaridurg
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia; Brien Holden Vision Institute, Sydney, Australia
| | | | - Louise Terry
- School of Optometry and Vision Sciences, Cardiff University, UK
| | - Mark Willcox
- School of Optometry and Vision Science, UNSW Sydney, Sydney, NSW, Australia
| |
Collapse
|