1
|
Shuaibu A, Topah EK, Suleman A, D'Esposito F, Tognetto D, Gagliano C, Zeppieri M, Musa M. Contact Lenses in Therapeutic Care: A Comprehensive Review of Past Innovations, Present Applications, and Future Directions. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2025. [PMID: 39841382 DOI: 10.1007/5584_2024_842] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/23/2025]
Abstract
Contact lenses have become integral tools in the realm of ocular therapeutics, extending beyond their primary function of refractive correction to encompass a diverse array of therapeutic applications. This review explores the evolving role of contact lenses in managing various ocular conditions, highlighting their efficacy in enhancing patient outcomes. Initially developed to correct refractive errors, contact lenses now serve as effective vehicles for delivering medications directly to the ocular surface, offering targeted treatment for conditions such as dry eye syndrome and corneal ulcers. Their ability to provide sustained moisture and facilitate drug absorption makes them indispensable in promoting corneal healing and managing chronic ocular surface diseases. Specialized contact lenses designed for irregular corneas, such as those affected by keratoconus, provide both optical correction and structural support, significantly improving visual acuity and patient comfort. Additionally, orthokeratology lenses have shown promise in controlling myopia progression in children by reshaping the cornea overnight, thereby reducing reliance on corrective eyewear during waking hours. In post-surgical settings, therapeutic contact lenses aid in epithelial regeneration and minimize discomfort, accelerating recovery and improving surgical outcomes. They also play a crucial role in protecting the cornea from external irritants and promoting a stable tear film, crucial for maintaining ocular health. Looking ahead, ongoing advancements in contact lens materials and designs promise further innovation in ocular therapeutics, paving the way for personalized treatment strategies and improved patient care. As such, contact lenses continue to evolve as essential therapeutic tools, offering tailored solutions for a spectrum of ocular conditions and contributing to enhanced quality of life for patients worldwide.
Collapse
Affiliation(s)
- Ayishetu Shuaibu
- Department of Optometry, University of Benin, Benin City, Nigeria
| | - Efioshiomoshi Kings Topah
- Department of Optometry, Faculty of Allied Health Sciences, College of Health Sciences, Bayero University, Kano, Nigeria
| | - Ayuba Suleman
- Department of Ophthalmology, Africa Eye Laser Center Ltd, Benin, Nigeria
| | - Fabiana D'Esposito
- Imperial College Ophthalmic Research Group (ICORG) Unit, Imperial College, London, UK
- Department of Neurosciences, Reproductive Sciences and Dentistry, University of Naples Federico II, Napoli, Italy
| | - Daniele Tognetto
- Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy
| | - Caterina Gagliano
- Department of Medicine and Surgery, University of Enna "Kore", Piazza dell'Università, Enna, Italy
- Mediterranean Foundation "G.B. Morgagni", Catania, Italy
| | - Marco Zeppieri
- Department of Ophthalmology, University Hospital of Udine, Udine, Italy.
| | - Mutali Musa
- Department of Optometry, University of Benin, Benin City, Nigeria
- Department of Ophthalmology, Africa Eye Laser Center Ltd, Benin, Nigeria
| |
Collapse
|
2
|
Lim C, García-Montero M, Courtis A, Hainey P, Madrid-Costa D, Crooke A. Optimization of the Oxygen Permeability of Non-Silicone Hydrogel Contact Lenses Through Crosslinking Modifications. Gels 2024; 10:726. [PMID: 39590082 PMCID: PMC11593662 DOI: 10.3390/gels10110726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2024] [Revised: 11/03/2024] [Accepted: 11/06/2024] [Indexed: 11/28/2024] Open
Abstract
The main weakness of non-silicone hydrogel contact lenses is their low oxygen permeability (Dk). Hence, we have tried to optimize their Dk using various concentrations and lengths of the poly (ethylene glycol) dimethacrylate crosslinker in a mixture of N,N-Dimethylacrylamide and Cyclohexyl methacrylate monomers. After synthesizing the different contact lenses, we evaluated their chemical, optical, and mechanical properties. The resultant non-silicone hydrogel contact lenses presented similar high water contents (75.69-80.60%) and adequate optical (e.g., a transmittance ranging from 85.91% to 99.91% and a refractive index between 1.3630 and 1.3740) and elongation at break (178.95-356.05%) characteristics for clinical applications. Conversely, they presented high contact angles (81.00-100.00°) and a low Young's modulus (0.066-0.167 MPa). Regarding the impact of the crosslinking modifications, the water content, contact angle, refractive index, transmittance, and Young's modulus of the synthesized lenses were slightly affected by crosslinker conditions. In contrast, the elongation at break (178.95-356.05%) and, more importantly, the oxygen permeability, which reached values of up to 73.90 Fatt units, were considerably impacted by the crosslinker conditions. To our knowledge, this study demonstrates for the first time that, in addition to water, other usual hydrogel components, like crosslinkers, can modulate the Dk of non-silicone contact lenses. It also provides a simple and scalable method to fabricate more permeable non-silicone lenses.
Collapse
Affiliation(s)
- Clara Lim
- Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain (M.G.-M.); (D.M.-C.)
- Department of Biochemistry and Molecular Biology, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain
- Research and Development Group, Mark’ennovy, Widnes WA8 0RP, UK; (A.C.); (P.H.)
| | - María García-Montero
- Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain (M.G.-M.); (D.M.-C.)
- Clinical and Experimental Eye Research Group, UCM 971009, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain
| | - Andrew Courtis
- Research and Development Group, Mark’ennovy, Widnes WA8 0RP, UK; (A.C.); (P.H.)
| | - Paul Hainey
- Research and Development Group, Mark’ennovy, Widnes WA8 0RP, UK; (A.C.); (P.H.)
| | - David Madrid-Costa
- Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain (M.G.-M.); (D.M.-C.)
- Clinical and Experimental Eye Research Group, UCM 971009, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain
| | - Almudena Crooke
- Department of Biochemistry and Molecular Biology, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain
- Clinical and Experimental Eye Research Group, UCM 971009, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain
| |
Collapse
|
3
|
Morgan PB, Efron N, Papas E, Barnett M, Carnt N, Dutta D, Hepworth A, Little JA, Nagra M, Pult H, Schweizer H, Shen Lee B, Subbaraman LN, Sulley A, Thompson A, Webster A, Markoulli M. BCLA CLEAR Presbyopia: Management with contact lenses and spectacles. Cont Lens Anterior Eye 2024; 47:102158. [PMID: 38631935 DOI: 10.1016/j.clae.2024.102158] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/19/2024]
Abstract
This paper seeks to outline the history, market situation, clinical management and product performance related to the correction of presbyopia with both contact lenses and spectacles. The history of the development of various optical forms of presbyopic correction are reviewed, and an overview is presented of the current market status of contact lenses and spectacles. Clinical considerations in the fitting and aftercare of presbyopic contact lens and spectacle lens wearers are presented, with general recommendations for best practice. Current options for contact lens correction of presbyopia include soft simultaneous, rigid translating and rigid simultaneous designs, in addition to monovision. Spectacle options include single vision lenses, bifocal lenses and a range of progressive addition lenses. The comparative performance of both contact lens and spectacle lens options is presented. With a significant proportion of the global population now being presbyopic, this overview is particularly timely and is designed to act as a guide for researchers, industry and eyecare practitioners alike.
Collapse
Affiliation(s)
- Philip B Morgan
- Eurolens Research, Division of Pharmacy and Optometry, University of Manchester, United Kingdom.
| | - Nathan Efron
- Optometry and Vision Science, Queensland University of Technology, Brisbane, Queensland, Australia
| | - Eric Papas
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | | | - Nicole Carnt
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| | - Debarun Dutta
- Optometry and Vision Science Research Group, Aston University, Birmingham, United Kingdom
| | - Andy Hepworth
- EssilorLuxottica Europe North, Bristol, United Kingdom
| | - Julie-Anne Little
- Centre for Optometry and Vision Science, Biomedical Sciences Research Institute, Ulster University, Coleraine, United Kingdom
| | - Manbir Nagra
- Vision and Eye Research Institute, ARU, Young Street, Cambridge, United Kingdom
| | - Heiko Pult
- Dr Heiko Pult - Optometry and Vision Research, Weinheim, Germany
| | - Helmer Schweizer
- CEO Helmer Schweizer Consulting Group (HSCG), Bassersdorf, Switzerland
| | - Bridgitte Shen Lee
- Vision Optique and Ocular Aesthetics dba Ocular Clinical Trials, Houston, TX, United States
| | | | - Anna Sulley
- CooperVision International Ltd, Chandlers Ford, United Kingdom
| | | | | | - Maria Markoulli
- School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
| |
Collapse
|
4
|
Garcia-Queiruga J, Pena-Verdeal H, Ferreiro-Figueiras D, Noya-Padin V, Giraldez MJ, Yebra-Pimentel E. Assessing neophyte response to daily disposable silicone hydrogel contact lenses: A randomised clinical trial investigation over one month. Ophthalmic Physiol Opt 2024; 44:876-883. [PMID: 38712751 DOI: 10.1111/opo.13328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2024] [Revised: 04/22/2024] [Accepted: 04/24/2024] [Indexed: 05/08/2024]
Abstract
OBJECTIVE This randomised clinical trial assessed the impact on symptoms, tear film dynamics and ocular surface integrity of daily disposable silicone-hydrogel contact lenses (CLs) over a month, paying special attention to lid wiper epitheliopathy (LWE) and its implications for CL discomfort. METHODS Neophyte CL wearers (n = 44, 21.09 ± 5.00 years old) were randomly assigned to either the experimental (n = 24) or control group (n = 20). Participants assigned to the experimental group were required to wear daily disposable CLs for 1 month for at least 8 h/day and 6 days/week. All participants were healthy subjects (no history of ocular surgery or active ocular disease) with spherical refractive errors between -8.00 and +5.00 D and cylindrical power <0.75 D. At the baseline and 1-month sessions, the Dry Eye Questionnaire 5 (DEQ-5) was completed, together with the measurement of tear film osmolarity with the TearLab osmometer, tear meniscus height (TMH) and lipid layer pattern (LLP) using a slit-lamp with Tearscope Plus attached, fluorescein break-up time (FBUT), maximum blink interval (MBI), corneal staining with fluorescein under cobalt blue light and LWE with lissamine green under slit lamp and halogen white light. RESULTS At the baseline session, LWE showed a negative correlation with DEQ-5 (r = -0.37, p = 0.02). Significant differences in FBUT and LWE (p = 0.04) and a positive correlation between LWE and DEQ-5 (r = 0.49, p = 0.007) were observed at 1 month. Intrasession analysis at 1 month showed significant differences between the experimental and control groups in DEQ-5, FBUT and LWE (all p ≤ 0.02). Intersession analysis in the experimental group showed variations in DEQ-5, FBUT and LWE (all p ≤ 0.02) but no significant variation in the control group (all p ≥ 0.11). CONCLUSION The presence of LWE was significantly correlated with higher symptom values in the DEQ-5. Also, participants in the experimental group presented higher values of LWE after 1 month of CL wear, in comparison with the control group.
Collapse
Affiliation(s)
- Jacobo Garcia-Queiruga
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
- AC-24 Optometría, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| | - Hugo Pena-Verdeal
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
- AC-24 Optometría, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| | - Dolores Ferreiro-Figueiras
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
| | - Veronica Noya-Padin
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
- AC-24 Optometría, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| | - Maria J Giraldez
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
- AC-24 Optometría, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| | - Eva Yebra-Pimentel
- Departamento de Física Aplicada (Área de Optometría), Facultade de Óptica e Optometría, Universidade de Santiago de Compostela, Santiago de Compostela, Spain
- AC-24 Optometría, Instituto de Investigación Sanitaria de Santiago de Compostela (IDIS), Santiago de Compostela, Spain
| |
Collapse
|
5
|
Fogt JS, Satiani N, Bickle KM, Wesley G, Patton K. Wear Experiences with Two Soft Contact Lenses for Astigmatism of Different Modalities. CLINICAL OPTOMETRY 2024; 16:93-100. [PMID: 38559802 PMCID: PMC10981420 DOI: 10.2147/opto.s452132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Accepted: 03/06/2024] [Indexed: 04/04/2024]
Abstract
Introduction Patients expect to have excellent vision and comfort when wearing soft contact lenses. The purpose of this study was to compare the wear experiences of participants with astigmatism when wearing a daily disposable soft toric lens to an established, commonly used reusable toric lens. Methods In this crossover study, habitual soft toric lens wearers were fit with a daily replacement soft toric lens (delefilcon A) and a reusable, 1-month replacement soft toric lens (comfilcon A) in a randomized order. After 30 days of wear, Visual analog scale (VAS) surveys were used to assess wear experience, including vision and comfort, for overall wear and end-of-day wear. Scores were compared statistically with mixed-effects linear models. Participants also responded to questions about convenience, ease of use, and satisfaction with both lenses and preference questions based upon comfort, vision, and overall performance. Results Fifty-nine participants completed the multi-site crossover study. VAS scores [mean(std dev)] for overall quality of vision for the delefilcon A [80.4(16.4)] and comfilcon A [66.8(27.7)] lenses were statistically significant (P=0.002). The difference in the mean overall comfort scores for the delefilcon A lenses [71.6(26.3)] and comfilcon A lenses [63.2(28.9)] was 8.4, which exceeds the establish criteria for clinical significance, although not statistically significant (P=0.08). Overall satisfaction scores were 68.8(26.9) for the delefilcon A and 59.7(30.3) for the comfilcon A lenses (P=0.08). Both lenses provided mean binocular visual acuities better than 20/20 Snellen equivalent. Over half of the participants preferred the delefilcon A lenses based upon comfort, vision, and overall performance. Convenience, ease of use, and satisfaction all scored higher with delefilcon A lenses. Conclusion The results of this study show that wear experience with delefilcon A lenses for astigmatism can meet or exceed that of comfilcon A toric lenses while also providing healthy, daily disposable lens wear.
Collapse
Affiliation(s)
| | - Nidhi Satiani
- College of Optometry, The Ohio State University, Columbus, OH, USA
| | | | - Gina Wesley
- College of Optometry, The Ohio State University, Columbus, OH, USA
| | - Kimberly Patton
- College of Optometry, The Ohio State University, Columbus, OH, USA
| |
Collapse
|
6
|
Costa D, De Matteis V, Treso F, Montani G, Martino M, Rinaldi R, Corrado M, Cascione M. Impact of the physical properties of contact lens materials on the discomfort: role of the coefficient of friction. Colloids Surf B Biointerfaces 2024; 233:113630. [PMID: 37956592 DOI: 10.1016/j.colsurfb.2023.113630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2023] [Revised: 10/31/2023] [Accepted: 11/01/2023] [Indexed: 11/15/2023]
Abstract
Contact Lens Discomfort (CLD) is the main cause in contact lens (CLs) discontinuation, referred in literature as drop-out phenomenon. Despite such evidence was reported in several clinical studies, a relationship between physico-chemical properties of CLs and CLD is not still totally understood. In this regard, the friction of CLs surfaces seems to be related to discomfort feeling events, probably due to an alteration of the lubricate function of the tear film after the CL placement inside the ocular environment. In the last years, many studies have been finalized to the friction measurements of CLs surface, finding conflicting data due to a lack in standardized protocol. The aim of this review is primarily to show evident relationships between CLs surface properties (i.e. wettability, tear evaporation, tear film quality, etc.) and the coefficient of friction (CoF), resulting therefore the most relevant physical quantity in the CLs characterization. In addition, we reported the most recent studies in CLs tribology, which highlight that the introduction of a standard protocol in CoF measurements is necessary to obtain reproducible results, considering the aim to evaluate in a more precise way the relationship between this material surface property and comfort in CLs users.
Collapse
Affiliation(s)
- D Costa
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy
| | - V De Matteis
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy.
| | - F Treso
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - G Montani
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - M Martino
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy
| | - R Rinaldi
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy
| | - M Corrado
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy
| | - M Cascione
- Department of Mathematics and Physics "Ennio De Giorgi", University of Salento, Via Arnesano, Lecce 73100, Italy; Institute for Microelectronics and Microsystems (IMM), CNR, Via Monteroni, Lecce 73100, Italy; Centro di Ricerca in Contattologia Avanzata, Via Arnesano, Lecce 73100, Italy.
| |
Collapse
|
7
|
Zhou A, Goh AQY, Steinemann TL. Law and Order: The Regulation of Contact Lens Sales in the United States Today. Eye Contact Lens 2023; 49:447-448. [PMID: 37876278 DOI: 10.1097/icl.0000000000001033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/29/2023] [Indexed: 10/26/2023]
Affiliation(s)
- Avery Zhou
- Kirk Kerkorian School of Medicine (A.Z.), Las Vegas, NV; MOH Holdings Private Limited (A.Q.Y.G.), Singapore, Singapore; School of Medicine (T.L.S.), Case Western Reserve University, Cleveland, OH; and Division of Ophthalmology (T.L.S.), MetroHealth Medical Center, Cleveland, OH
| | | | | |
Collapse
|
8
|
Haworth K, Travis D, Leslie L, Fuller D, Pucker AD. Silicone hydrogel versus hydrogel soft contact lenses for differences in patient-reported eye comfort and safety. Cochrane Database Syst Rev 2023; 9:CD014791. [PMID: 37724689 PMCID: PMC10507745 DOI: 10.1002/14651858.cd014791.pub2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/21/2023]
Abstract
BACKGROUND Ocular discomfort is the leading cause of permanent discontinuation of soft contact lens (SCL) wear. Silicone hydrogel and hydrogel materials are the two major categories of SCLs, with silicone hydrogel materials being newer and more breathable than hydrogel materials. Whether comfort is associated with SCL material is controversial despite numerous studies. Similarly, the difference between these materials in terms of safety outcomes (e.g. frequency of microbial keratitis) is unclear. OBJECTIVES To evaluate the comparative effectiveness and safety of silicone hydrogel compared with hydrogel SCLs on self-reported comfort, dry eye test results, and adverse events in SCL-wearing adults 18 years of age or older. SEARCH METHODS The Cochrane Eyes and Vision Information Specialist searched the electronic databases for randomized controlled trials (RCTs). There were no restrictions on language or date of publication. We searched the Cochrane Central Register of Controlled Trials (CENTRAL, including the Cochrane Eyes and Vision Trials Register; 2022, Issue 6), MEDLINE Ovid, Embase.com, PubMed, LILACS (Latin American and Caribbean Health Science Information database), ClinicalTrials.gov, and World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP). We also searched the reference lists of identified studies, review articles, and guidelines for information about relevant studies that may not have been identified by our search strategy. Furthermore, we contacted investigators regarding ongoing trials. The most recent database search was conducted on 24 June 2022. SELECTION CRITERIA Our search selection criteria included RCTs, quasi-RCTs, and cross-over RCTs. DATA COLLECTION AND ANALYSIS We applied standard Cochrane methodology. MAIN RESULTS We included seven parallel-group RCTs conducted in the USA, the UK, Australia, Germany, India, and Turkey. A total of 1371 participants were randomized. The duration of SCL wear ranged from one to 52 weeks. Study characteristics and risk of bias The median number of participants per trial was 120 (interquartile range: 51 to 314), and the average age ranged from 20.7 to 33.0 years. Women represented the majority of participants (range 55% to 74.9%; 5 RCTs). Collectively, the included trials compared eight different silicone hydrogel SCLs with three different hydrogel SCLs. Five trials compared daily disposable SCLs, and two compared extended wear SCLs (worn for seven days and six nights). New SCL wearers were enrolled in three trials. Two trials included both new and established SCL wearers, and two trials did not report participants' history of SCL use. Five trials were sponsored by industry. We judged the overall risk of bias to be 'high' or 'some concerns' for the safety and efficacy outcomes. Findings One trial reported Ocular Surface Disease Index (OSDI) results, with the evidence being very uncertain about the effects of SCL material on OSDI scores (mean difference -1.20, 95% confidence interval [CI] -10.49 to 8.09; 1 RCT, 47 participants; very low certainty evidence). Three trials reported visual analog scale comfort score results, with no clear difference in comfort between materials, but the evidence was of very low certainty; trial results could not be combined because the three trials reported results at different time points. The evidence is very uncertain about the effect of SCL material on discontinuation of contact lens wear (risk ratio [RR] 0.64, 95% CI 0.11 to 3.74; 1 RCT, 248 participants). None of the included trials reported Contact Lens Dry Eye Questionnaire (CLDEQ-8) or Standard Patient Evaluation of Eye Dryness (SPEED) scores. There was no evidence of a clinically meaningful difference (> 0.5 unit) between daily disposable silicone hydrogel and hydrogel SCLs in corneal staining, conjunctival staining, or conjunctival redness (very low certainty evidence). Adverse events Very low certainty evidence from two trials comparing daily disposable SCLs suggested no evidence of a difference between lens materials in the risk of vision-threatening adverse events at one to four weeks (RR 0.68, 95% CI 0.08 to 5.51; 2 RCTs, 368 participants). Two trials comparing extended wear SCLs indicated that hydrogel SCLs may have a 2.03 times lower risk of adverse events at 52 weeks compared with silicone hydrogel SCLs (RR 2.03, 95% CI 1.38 to 2.99; 815 participants), but the certainty of evidence was very low. AUTHORS' CONCLUSIONS The overall evidence for a difference between all included silicone hydrogel and hydrogel SCLs was of very low certainty, with most trials at high overall risk of bias. The majority of studies did not assess comfort using a validated instrument. There was insufficient evidence to support recommending one SCL material over the other. For extended wear, hydrogel SCL may have a lower risk of adverse events at 52 weeks compared to silicon hydrogel. Future well-designed trials are needed to generate high certainty evidence to further clarify differences in SCL material comfort and safety.
Collapse
Affiliation(s)
| | - Darian Travis
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| | - Louis Leslie
- Department of Ophthalmology, University of Colorado Anschutz Medical Campus, Aurora, Colorado, USA
| | - Daniel Fuller
- Cornea Contact Lens Service, The Eye Center, Southern College of Optometry, Memphis, TN, USA
| | - Andrew D Pucker
- School of Optometry, University of Alabama at Birmingham, Birmingham, Alabama, USA
| |
Collapse
|
9
|
Jones L, Efron N, Bandamwar K, Barnett M, Jacobs DS, Jalbert I, Pult H, Rhee MK, Sheardown H, Shovlin JP, Stahl U, Stanila A, Tan J, Tavazzi S, Ucakhan OO, Willcox MDP, Downie LE. TFOS Lifestyle: Impact of contact lenses on the ocular surface. Ocul Surf 2023; 29:175-219. [PMID: 37149139 DOI: 10.1016/j.jtos.2023.04.010] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 04/10/2023] [Indexed: 05/08/2023]
Abstract
Several lifestyle choices made by contact lens wearers can have adverse consequences on ocular health. These include being non-adherent to contact lens care, sleeping in lenses, ill-advised purchasing options, not seeing an eyecare professional for regular aftercare visits, wearing lenses when feeling unwell, wearing lenses too soon after various forms of ophthalmic surgery, and wearing lenses when engaged in risky behaviors (e.g., when using tobacco, alcohol or recreational drugs). Those with a pre-existing compromised ocular surface may find that contact lens wear exacerbates ocular disease morbidity. Conversely, contact lenses may have various therapeutic benefits. The coronavirus disease-2019 (COVID-19) pandemic impinged upon the lifestyle of contact lens wearers, introducing challenges such as mask-associated dry eye, contact lens discomfort with increased use of digital devices, inadvertent exposure to hand sanitizers, and reduced use of lenses. Wearing contact lenses in challenging environments, such as in the presence of dust and noxious chemicals, or where there is the possibility of ocular trauma (e.g., sport or working with tools) can be problematic, although in some instances lenses can be protective. Contact lenses can be worn for sport, theatre, at high altitude, driving at night, in the military and in space, and special considerations are required when prescribing in such situations to ensure successful outcomes. A systematic review and meta-analysis, incorporated within the review, identified that the influence of lifestyle factors on soft contact lens dropout remains poorly understood, and is an area in need of further research. Overall, this report investigated lifestyle-related choices made by clinicians and contact lens wearers and discovered that when appropriate lifestyle choices are made, contact lens wear can enhance the quality of life of wearers.
Collapse
Affiliation(s)
- Lyndon Jones
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada.
| | - Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia
| | - Kalika Bandamwar
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Melissa Barnett
- University of California, Davis Eye Center, Sacramento, CA, USA
| | - Deborah S Jacobs
- Massachusetts Eye & Ear, Harvard Medical School, Boston, MA, USA
| | - Isabelle Jalbert
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Heiko Pult
- Dr Heiko Pult Optometry & Vision Research, Weinheim, Germany
| | | | - Heather Sheardown
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | | | - Ulli Stahl
- Centre for Ocular Research & Education (CORE), School of Optometry and Vision Science, University of Waterloo, Waterloo, ON, Canada
| | | | - Jacqueline Tan
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Silvia Tavazzi
- Department of Materials Science, University of Milano-Bicocca, Milan, Italy
| | | | - Mark D P Willcox
- School of Optometry and Vision Science, UNSW Sydney, NSW, Australia
| | - Laura E Downie
- Department of Optometry and Vision Sciences, The University of Melbourne, Parkville, Victoria, Australia
| |
Collapse
|
10
|
Gone Viral: A Cross-Sectional Analysis of Contact Lens-Related Videos on TikTok. Eye Contact Lens 2022; 48:479-484. [PMID: 36044821 DOI: 10.1097/icl.0000000000000936] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/01/2022] [Indexed: 02/04/2023]
Abstract
OBJECTIVES To evaluate the content, sources, and quality of contact lens (CL)-related videos on TikTok, the fastest growing social media platform worldwide. METHODS TikTok was queried on October 25, 2021 for the top 200 posts with the hashtag "#contactlenses." Posts meeting inclusion criteria were characterized and assessed for quality with DISCERN, a validated scoring instrument for the appraisal of consumer health information (score range 1-5 with a higher score indicating a higher quality video). RESULTS The included 113 posts showed a mean quality of 1.94±0.44. Content included product displays (42%), patient experiences (23%), educational (22%), and comedy (12%). Most product displays featured decorative lenses (98%). Although videos by eye-care providers (ECPs) accounted for most educational content (52%) and showed significantly higher mean quality compared with posts by non-ECPs (2.57±0.18 vs. 1.85±0.13, P <0.001), they were a minority (12%) and showed poor overall quality. Contact lens representation was greatly skewed toward decorative lenses (74%), whereas only 3.5% of videos promoted seeing an ECP. CONCLUSIONS Poor quality and skewed representation of posts indicate that CL-related information on TikTok has serious shortcomings. These findings are particularly concerning given that most TikTok users are adolescents and young adults, the same population who tend to be decorative lens wearers and who are at increased risk of CL-related complications. Eye-care providers, professional organizations, and regulatory agencies should be urged to increase their engagement with the platform, especially regarding educational content creation and CL marketing oversight.
Collapse
|
11
|
Efron N. Dangers of uninformed soft contact lens selling and substitution recognised. Cont Lens Anterior Eye 2022; 45:101577. [PMID: 35210168 DOI: 10.1016/j.clae.2022.101577] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Affiliation(s)
- Nathan Efron
- School of Optometry and Vision Science, Queensland University of Technology, Kelvin Grove, Queensland, Australia.
| |
Collapse
|