1
|
Meisterhans M, Calek AK, Zindel C, Ongini E, Somm M, Vlachopoulos L, Fucentese SF. Influence of varus-producing distal femur osteotomy correction and hinge width in relation to hinge fractures: Biomechanical study on porcine femora. Knee 2024; 51:282-291. [PMID: 39454242 DOI: 10.1016/j.knee.2024.10.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 08/25/2024] [Accepted: 10/01/2024] [Indexed: 10/28/2024]
Abstract
BACKGROUND Hinge fractures in varus-producing distal femoral osteotomies (DFOs) lead to decreased axial and torsional stability. The purpose of this study was to assess (1) which hinge width has a high risk of hinge fracture in DFO for lateral opening wedge (LOW) and medial closing wedge (MCW) osteotomies, (2) which osteotomies allow for greater correction before risking a fracture, (3) whether patient-specific instrumentation (PSI) allows accurate hinge width planning. METHODS Thirty porcine femoral bones were divided into two groups: LOW, MCW with hinge widths of 5 mm, 7.5 mm, and 10 mm as subgroups. Osteotomies were performed in a PSI-navigated fashion. A force parallel to the longitudinal bone axis was applied in a uniaxial testing machine until a fracture occurred. RESULTS The maximum correction was 6.7 ± 1.1° for LOW and 13.4 ± 1.9° for MCW (β0 < 0.001, β1 = 0.002, β2 = 0.02, β3 = 0.005). The relative error of the planned hinge width compared with the actual hinge width was -3.7 ± 12.3% for LOW (P = 0.25) and 12.3 ± 13.1% for MCW (P = 0.003). CONCLUSIONS Increasing the hinge width allows for greater correction in MCW osteotomies. For LOW osteotomies, a smaller hinge width seems to be advantageous because it allows a greater correction without the risk of hinge fracture. With PSI-guided LOW osteotomies, the planned hinge width could be achieved intraoperatively with greater accuracy than with MCW osteotomies. However, the MCW osteotomy appears to be the preferred option when larger corrections are desired because a larger correction angle can be achieved without the risk of intraoperative hinge fracture.
Collapse
Affiliation(s)
- Michel Meisterhans
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland.
| | - Anna-Katharina Calek
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Christoph Zindel
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Esteban Ongini
- Institute of Biomechanics, Balgrist Campus, ETH Zurich, Zurich, Switzerland
| | - Mario Somm
- Institute of Biomechanics, Balgrist Campus, ETH Zurich, Zurich, Switzerland
| | - Lazaros Vlachopoulos
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| | - Sandro F Fucentese
- Department of Orthopedics, Balgrist University Hospital, University of Zurich, Zurich, Switzerland
| |
Collapse
|
2
|
Superior survivorship and plate-related results of TomoFix compared to Puddu plate fixation for opening-wedge high tibial osteotomy: A systematic review of the literature. Knee 2023. [PMID: 36863116 DOI: 10.1016/j.knee.2023.02.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Abstract
PURPOSE This systematic review aimed to compare survivorship and plate-related results of Puddu and TomoFix plates in opening-wedge high tibial osteotomy (OWHTO). METHODS PubMed, Scopus, EMBASE, and CENTRAL databases were searched from January 2000 until September 2021 for clinical studies involving patients with medial compartment knee disease and varus deformity undergoing OWHTO using the Puddu or TomoFix plating systems. We extracted survival data, plate-related complications, and functional and radiological outcomes. The risk of bias assessment had been carried out using Cochrane Collaboration's quality assessment tool for randomised controlled trials (RCTs) and Methodological Index for Non-Randomised Studies (MINORS). RESULTS Twenty-eight studies were included. The total number of knees was 2568 in 2372 patients. The Puddu plate was used in 677 knees, while the TomoFix plate was used in 1891. The follow-up ranged from 5.8 to 147.6 months. Both plating systems were able to delay conversion to arthroplasty at different follow-up intervals. However, osteotomies fixed by the TomoFix plate achieved higher survival rates, especially at mid-term and long-term follow-ups. In addition, fewer complications were reported with the TomoFix plating system. Although both implants achieved satisfactory functional outcomes, high scores could not be maintained throughout long-term intervals. Regarding radiological results, TomoFix plate was able to achieve and maintain larger degrees of varus deformity, while preserving the posterior tibial slope. CONCLUSIONS This systematic review demonstrated the superiority of the TomoFix over the Puddu system as a safer and more effective fixation device in OWHTO. Nevertheless, these results should be interpreted with caution due to the lack of comparative evidence through high-quality RCTs.
Collapse
|
3
|
Forgivingness of an Anteromedially Positioned Small Locked Plate for High Tibial Osteotomy in Case of Overcorrection and Lateral Hinge Fracture. LIFE (BASEL, SWITZERLAND) 2022; 12:life12081265. [PMID: 36013443 PMCID: PMC9409794 DOI: 10.3390/life12081265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 08/16/2022] [Accepted: 08/17/2022] [Indexed: 11/17/2022]
Abstract
High tibial osteotomy (HTO) represents a sensible treatment option for patients with moderate unicondylar osteoarthritis of the knee and extraarticular malalignment. The possibility of a continuously variable correction setting and a surgical approach low in complications has meant that the medial opening osteotomy has prevailed over the past decades. The objective of the present study was to determine whether anteromedially positioned small plates are nevertheless forgiving under biomechanically unfavourable conditions (overcorrection and lateral hinge fracture). In this study, a simulated HTO was performed on composite tibiae with a 10-mm wedge and fixed-angle anteromedial osteosynthesis with a small implant. Force was applied axially in a neutral mechanical axis, a slight and a marked overcorrection into valgus, with and without a lateral hinge fracture in each case. At the same time, a physiological gait with a dual-peak force profile and a peak load of 2.4 kN was simulated. Interfragmentary motion and rigidity were determined. The rigidity of the osteosynthesis increased over the cycles investigated. A slight overcorrection into valgus led to the lowest interfragmentary motion, compared with pronounced valgisation and neutral alignment. A lateral hinge fracture led to a significant decrease in rigidity and increase in interfragmentary motion. However, in no case was the limit of 1 mm interfragmentary motion critical for osteotomy healing exceeded. The degree of correction of the leg axis, and the presence of a lateral hinge fracture, have an influence on rigidity and interfragmentary motion. From a mechanically neutral axis ranging up to pronounced overcorrection, the implant investigated offers sufficient stability to allow healing of the osteotomy, even if a lateral hinge fracture is present.
Collapse
|
4
|
Miettinen S, Nyländen H, Jalkanen J, Miettinen H, Kröger H, Joukainen A. Midterm follow-up results of two different types of implants in opening wedge high tibia osteotomy. Knee 2021; 31:11-21. [PMID: 34102476 DOI: 10.1016/j.knee.2021.05.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2020] [Revised: 03/26/2021] [Accepted: 05/19/2021] [Indexed: 02/02/2023]
Abstract
BACKGROUND This retrospective study investigated the midterm results of medial opening wedge high tibia osteotomy, with a monoplanar or a biplanar osteotomy using two types of implant system. METHODS Osteotomies were performed on 241 knees (231 patients). The mean follow-up period was 6.0 years (SD 3.0, range 0.2-12.8 years). Two types of implant system were used, a precountered non-locking plate (PP) (n = 74) and a precountered locking plate (LP) (n = 167). A Kaplan-Meier cumulative survival curve and a Cox regression model were used to analyse and revise survival and risk factors. RESULTS Cumulative survival estimates for LP were 80% at 5 years, and 64% at 10 years (SE = 0.4, CI 95%: 9.0-10.5), and for PP, they were 68% at 5 years and 49% at 10 years (SE = 0.5, CI: 95% 6.3-8.2) (p = 0.024). The revision rate was 26% (44/167) for the LP group, and 47% (35/74) for the PP group (p = 0.001). Reoperations on LP osteotomies occurred for the tibial monoplanar cut and biplanar cut groups, in 19/52 (37%) and 25/167 (16%) osteotomies, respectively (p = 0.04). Our Cox regression model showed that PP had a higher risks (RR = 1.7; CI: 95% 1.1-2.6) of revision, when compared with LP (p = 0.026). CONCLUSIONS The risk of revision for any reason and that of early conversion to total knee arthroplasty (TKA) after high tibia osteotomy were significantly increased for PP, when compared with LP.
Collapse
Affiliation(s)
- Simo Miettinen
- Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, P.O. Box 1777, 70211 Kuopio, Finland; University of Eastern Finland, Faculty of Health Sciences, Yliopistonranta 1, 70210 Kuopio, Finland.
| | - Henrik Nyländen
- University of Eastern Finland, Faculty of Health Sciences, Yliopistonranta 1, 70210 Kuopio, Finland
| | - Jussi Jalkanen
- Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, P.O. Box 1777, 70211 Kuopio, Finland
| | - Hannu Miettinen
- Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, P.O. Box 1777, 70211 Kuopio, Finland
| | - Heikki Kröger
- Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, P.O. Box 1777, 70211 Kuopio, Finland; University of Eastern Finland, Faculty of Health Sciences, Yliopistonranta 1, 70210 Kuopio, Finland
| | - Antti Joukainen
- Department of Orthopaedics, Traumatology and Hand Surgery, Kuopio University Hospital, P.O. Box 1777, 70211 Kuopio, Finland
| |
Collapse
|
5
|
Hartz C, Wischatta R, Klostermeier E, Paetzold M, Gerlach K, Pries F. Plate-related results of opening wedge high tibial osteotomy with a carbon fiber reinforced poly-ether-ether-ketone (CF-PEEK) plate fixation: a retrospective case series of 346 knees. J Orthop Surg Res 2019; 14:466. [PMID: 31881906 PMCID: PMC6935191 DOI: 10.1186/s13018-019-1514-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Accepted: 12/11/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND While open wedge high tibial osteotomy (owHTO) is an established standard procedure to treat medial osteoarthritis of the knee in combination with varus deformity, it bears the risk of postoperative hardware failures and lateral cortical hinge fractures. This in turn can lead to an accelerated osteoarthritis, non-union, or a loss of correction accuracy. The purpose of the study was to evaluate the radiologic outcomes of owHTO with a carbon fiber reinforced poly-ether-ether-ketone (CF-PEEK) plate fixation in patients with medial osteoarthritis and varus deformity. METHODS Three hundred twenty-four consecutive patients (346 knees) who were treated with owHTO using the PEEKPower HTO plate were included in this retrospective study; 89.9% of the patients were overweight or obese. Patients were followed by conventional radiographs over a 12-month period. Typical plate-related results such as the time and quality of gap healing as well as the correction accuracy were analyzed. Furthermore, the number of lateral cortex fractures was determined. RESULTS Bony consolidation was observed after a mean gap healing time of 4.0 ± 1.7 months independent on the patients' weight (p = 0.2302). With increasing gap sizes, bony healing was significantly prolonged (p < 0.001). Additionally, patients with greater gap sizes had a significantly increased risk for a lateral cortex fracture (p = 0.0041). However, none of the patients had a non-union 1 year postoperative. A hinge fracture occurred in 30% of patients. Hinge fractures with Takeuchi grades I and II increased the gap healing time compared to no fracture (p = 0.0069 and p = 0.0002, respectively), but only 1.2% of patients with hinge fracture had a clinical relevant loss of correction ≥ 3 mm. No implant failures were found. CONCLUSIONS Open wedge HTO using the PEEKPower HTO plate for patients with medial osteoarthritis of the knee in combination with tibial varus deformity leads to excellent bony consolidation also in cases with a hinge fracture, a gap size > 12 mm as well as for severely obese patients.
Collapse
Affiliation(s)
- Claudia Hartz
- Department Arthroskopische Chirurgie und Sporttraumatologie, Mare Med , Eckernfoerder Strasse 219, 24119, Kronshagen, Germany.
| | - Ralph Wischatta
- Department Arthroskopische Chirurgie und Sporttraumatologie, Mare Med , Eckernfoerder Strasse 219, 24119, Kronshagen, Germany
| | - Eckhardt Klostermeier
- Department Arthroskopische Chirurgie und Sporttraumatologie, Mare Med , Eckernfoerder Strasse 219, 24119, Kronshagen, Germany
| | - Malte Paetzold
- Department Arthroskopische Chirurgie und Sporttraumatologie, Mare Med , Eckernfoerder Strasse 219, 24119, Kronshagen, Germany
| | - Klaus Gerlach
- Department Arthroskopische Chirurgie und Sporttraumatologie, Mare Med , Eckernfoerder Strasse 219, 24119, Kronshagen, Germany
| | - Frank Pries
- Department Arthroskopische Chirurgie und Sporttraumatologie, Mare Med , Eckernfoerder Strasse 219, 24119, Kronshagen, Germany
| |
Collapse
|
6
|
Na YG, Kwak DS, Chong S, Kim TK. Factors affecting stability after medial opening wedge high tibial osteotomy using locking plate: A cadaveric study. Knee 2019; 26:1313-1322. [PMID: 31443941 DOI: 10.1016/j.knee.2019.07.016] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/11/2018] [Accepted: 07/30/2019] [Indexed: 02/02/2023]
Abstract
OBJECTIVES To investigate the effect of screw length, lateral hinge fracture, and gap filling on stability after medial opening wedge high tibial osteotomy (MOW HTO) using a locking plate. METHODS Forty tibiae from fresh-frozen cadavers were randomly allocated into five groups. Group A was bicortically fixated, while Group B and Group C were unicortically fixated: 90% and 55% of drilled tunnel length, respectively. Group D was fixated using 90% length screws with a fractured lateral hinge. Group E was fixated using 90% length screws with gap filling using a bone substitute. Operated tibiae were tested under axial compressive load using a material testing machine. The medial gap changes under the serial axial load of 100-600 N and ultimate failure load were measured. RESULTS Group D showed the biggest medial gap change and lowest failure load, while Group E presented the smallest gap change and highest failure load. The medial gap changes tended to increase with shorter screw length, but the difference was not significant between Groups A, B, and C. Group C and Group D showed greater medial gap change and lower failure load compared with Group E, while not differing from Group A and Group B. CONCLUSIONS Unicortical fixation in proximal screw holes of a locking plate was not inferior to bicortical fixation regarding axial stability in MOW HTO, although proximal screws that are too short should be avoided. Lateral hinge fracture decreased, while gap filling with bone substitute increased axial stability.
Collapse
Affiliation(s)
- Young Gon Na
- Department of Orthopaedic Surgery, Gachon University Gil Medical Center, Incheon, Republic of Korea; Department of Orthopaedic Surgery, CM Hospital, Seoul, Republic of Korea
| | - Dai-Soon Kwak
- Department of Anatomy, Catholic Institute for Applied Anatomy, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea
| | - Suri Chong
- Department of Orthopaedic Surgery, CM Hospital, Seoul, Republic of Korea
| | - Tae Kyun Kim
- TK Orthopedic surgery, Seongnam-si, Gyeonggi-do, Republic of Korea.
| |
Collapse
|
7
|
Takahashi T, Takahashi M, Yamamoto H, Miura H. Biomechanical study of optimum anchorage in dome-shaped high tibial osteotomy. J Orthop Surg (Hong Kong) 2019; 26:2309499018792406. [PMID: 30103659 DOI: 10.1177/2309499018792406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
PURPOSE There has been no report to date on any biomechanical study regarding the strength of fixation at the osteotomy site in dome-shaped high tibial osteotomy (HTO). In this study, we evaluated the biomechanical strength of a spacer that we improved and determined the medial site of HTO. METHODS HTO correction angles of 15° and 20° were used in all experiments, which were performed on lower leg specimens from pigs ( n = 12). The osteotomy site was fixed by a locking plate and screws with a spacer. Compression (600 N/min until 1100 N) and extended cyclic loading (200 cycles at 1000-2000 N) were performed to compare initial displacements in HTO specimens with and without spacers. RESULTS The reduction ratios of displacement with and without spacers at HTO correction angles of 15° and 20° were 37% and 27%, respectively. No effect of the spacer at the correction angle of 15° was observed in the cyclic loading; however, the maximum displacement and amplitude were reduced with the spacer at the correction angle of 20°. CONCLUSIONS AND CLINICAL RELEVANCE When the HTO correction angle is small, the effect of the spacer is uncertain. However, the spacer is effective at an HTO correction angle of 20°.
Collapse
Affiliation(s)
- Toshiaki Takahashi
- 1 Community Medical Support Center, Ehime University Hospital, Ehime, Japan.,2 Department of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| | - Manabu Takahashi
- 3 Faculty of Collaborative Regional Innovation, Ehime University Graduate School of Science and Engineering, Ehime, Japan
| | - Haruyasu Yamamoto
- 2 Department of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| | - Hiromasa Miura
- 2 Department of Orthopaedic Surgery, Ehime University Graduate School of Medicine, Toon, Ehime, Japan
| |
Collapse
|
8
|
Ettinger S, Schwarze M, Yao D, Ettinger M, Claassen L, Stukenborg-Colsman C, Thermann H, Plaass C. Stability of supramalleolar osteotomies using different implants in a sawbone model. Arch Orthop Trauma Surg 2018; 138:1359-1363. [PMID: 29934820 DOI: 10.1007/s00402-018-2981-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/20/2018] [Indexed: 11/24/2022]
Abstract
BACKGROUND With ankle arthritis often affecting young patients, joint-sparing treatments instead of total joint replacement should be considered. Only a few implants were specially developed for supramalleolar osteotomies (SMOT). This study was performed to analyse the stability of different implants and their appropriateness for SMOT. METHODS Twenty-five bone models (Sawbone Europe, Malmö, Sweden) were used for biomechanical testing. SMOT were performed as a uniplanar osteotomy, leaving 5 mm of lateral bone intact with a standardized gap of 8 mm. Five different plates commonly used for SMOT were assessed. For axial stability, the constructs were tested during 100 cycles for each load (150N and 800N) at a rate of 0.5 Hz. For rotational stability, each construct was subject to 100 cycles of 5 Nm torque at a rate of 0.25 Hz, performing three runs with an axial preload of 0N, 150N, or 800N. Ultimate axial load was performed for one-half and ultimate rotational load was performed for the other half of the constructs. In addition, the stiffness of the different constructs after failure was tested. RESULTS All constructs showed high stability and could be tested until maximum cyclic load. There was no significant difference between the five plates, neither for stiffness (axial or rotational) nor for failure load (axial or rotational). One plate indicated superiority in axial failure testing without any significant difference. CONCLUSION All implants could be tested until maximum load. The intact hinge apparently provides enough support to compensate for lower moment of inertia of some plates. LEVEL OF EVIDENCE Not applicable.
Collapse
Affiliation(s)
- Sarah Ettinger
- Department of Foot and Ankle Surgery, Orthopaedic Clinic at DIAKOVERE Annastift, Hannover Medical School, Anna-von-Borries-Straße 1-7, 30625, Hannover, Germany
| | - Michael Schwarze
- Biomechanical Laboratory, Orthopaedic Clinic, Hannover Medical School, Hannover, Germany
| | - Daiwei Yao
- Department of Foot and Ankle Surgery, Orthopaedic Clinic at DIAKOVERE Annastift, Hannover Medical School, Anna-von-Borries-Straße 1-7, 30625, Hannover, Germany
| | - Max Ettinger
- Department of Foot and Ankle Surgery, Orthopaedic Clinic at DIAKOVERE Annastift, Hannover Medical School, Anna-von-Borries-Straße 1-7, 30625, Hannover, Germany
| | - Leif Claassen
- Department of Foot and Ankle Surgery, Orthopaedic Clinic at DIAKOVERE Annastift, Hannover Medical School, Anna-von-Borries-Straße 1-7, 30625, Hannover, Germany
| | - Christina Stukenborg-Colsman
- Department of Foot and Ankle Surgery, Orthopaedic Clinic at DIAKOVERE Annastift, Hannover Medical School, Anna-von-Borries-Straße 1-7, 30625, Hannover, Germany
| | | | - Christian Plaass
- Department of Foot and Ankle Surgery, Orthopaedic Clinic at DIAKOVERE Annastift, Hannover Medical School, Anna-von-Borries-Straße 1-7, 30625, Hannover, Germany.
| |
Collapse
|
9
|
Calcium phosphate cement enhances the torsional strength and stiffness of high tibial osteotomies. Knee Surg Sports Traumatol Arthrosc 2017; 25:817-822. [PMID: 26231147 DOI: 10.1007/s00167-015-3692-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/17/2014] [Accepted: 07/01/2015] [Indexed: 10/23/2022]
Abstract
PURPOSE There has been a resurgence in the use of opening wedge high tibial osteotomy (owHTO). Calcium phosphate cement has been shown to improve strength in compression for augmentation of tibial plateau and owHTO fixation. However, knee kinematics includes a torsional load during ambulation, which is as yet unstudied in this model. The purpose of this paper is to investigate the effect of injectable calcium phosphate cement on the biomechanical stability of standard high tibial osteotomy defect with applied torsional load and ultimate stiffness of the supporting construct. METHODS Testing was performed on 22 bone mineral density-matched and age-matched cadaver specimens. Intact specimens were treated with 10° opening wedge osteotomies, identical surgical techniques as clinically used and fixation provided by iBalance© PEEK implant (Arthrex, Naples FL). Nine specimens were augmented with calcium phosphate injectable cement, Quickset (Arthrex Inc., Naples Fl). Constructs were for construct stiffness, torsional loads to failure, and mechanisms of failure. As a gold-standard comparison group, four samples were tested with a titanium, fixed angle device alone: Contourlock plate (Arthrex Inc., Naples Fl). RESULTS Peak torque to failure was significantly greater in samples augmented with calcium phosphate bone cement (23.0 ± 9.6 Nm) compared with specimens fixed with PEEK implant alone (18.1 ± 7.3). Construct stiffness in torsion was also significantly improved with bone cement application (349.0 ± 126.8 Nm/°) compared with PEEK implant alone (202.2 ± 153.4 Nm/°) and fixed angle implant system (142.9 ± 74.7 Nm/°). CONCLUSION Injectable calcium phosphate cement improves the initial maximal torsional strength and stiffness of high tibial osteotomy construct.
Collapse
|
10
|
Ha JK, Yeom CH, Jang HS, Song HE, Lee SJ, Kim KH, Chung KS, Bhat MG, Kim JG. Biomechanical Analysis of a Novel Wedge Locking Plate in a Porcine Tibial Model. Clin Orthop Surg 2016; 8:373-378. [PMID: 27904718 PMCID: PMC5114248 DOI: 10.4055/cios.2016.8.4.373] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2015] [Accepted: 06/09/2016] [Indexed: 12/03/2022] Open
Abstract
Background The purpose of this study was to analyze biomechanical properties of a novel wedge locking plate in medial open wedge high tibial osteotomy (OWHTO) in a porcine tibial model. Methods A uniform 8-mm OWHTO was performed in 12 porcine tibiae. Six of them were subsequently fixed with the plate without a wedge, whereas the other 6 were additionally reinforced with a metal wedge of 8 mm. Biomechanical properties (stiffness, displacement of the osteotomy gap, and failure load) were evaluated under axial load. The different modes of failure were also investigated. Results The plate showed an axial stiffness of 2,457 ± 450 N/mm with a wedge and 1,969 ± 874 N/mm without a wedge. The maximum failure load was 5,380 ± 952 N with a wedge and 4,354 ± 607 N without a wedge. The plate with a wedge had a significantly greater failure load and significantly less displacement of medial gap at failure than that without a wedge (p = 0.041 and p = 0.002, respectively). The axial stiffness was not different between the two types of fixation. Most failures were caused by lateral cortex breakage and there was no implant failure. Conclusions The novel wedge locking plate showed excellent biomechanical properties and an additional wedge provided significant improvement. This plate can be a good fixation method for OWHTO.
Collapse
Affiliation(s)
- Jeong-Ku Ha
- Department of Orthopedic Surgery, Seoul Paik Hospital, University of Inje College of Medicine, Seoul, Korea
| | - Chul Hyun Yeom
- Department of Orthopedic Surgery, Seoul Paik Hospital, University of Inje College of Medicine, Seoul, Korea
| | - Ho Su Jang
- Department of Orthopedic Surgery, Seoul Paik Hospital, University of Inje College of Medicine, Seoul, Korea
| | - Han Eui Song
- Department of Orthopedic Surgery, Seoul Paik Hospital, University of Inje College of Medicine, Seoul, Korea
| | - Sung Jae Lee
- Department of Biomedical Engineering, Inje University, Gimhae, Korea
| | - Kang Hee Kim
- Department of Biomedical Engineering, Inje University, Gimhae, Korea
| | - Kyu Sung Chung
- Department of Orthopedic Surgery, Seoul Paik Hospital, University of Inje College of Medicine, Seoul, Korea
| | | | - Jin Goo Kim
- Department of Orthopaedic Surgery, Konkuk University School of Medicine, Seoul, Korea
| |
Collapse
|
11
|
Kim KJ, Song EK, Seon JK, Seol JH. Biomechanical Study of the Fixation Plates For Opening Wedge High Tibial Osteotomy. Knee Surg Relat Res 2015; 27:181-6. [PMID: 26389072 PMCID: PMC4570954 DOI: 10.5792/ksrr.2015.27.3.181] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2014] [Revised: 01/02/2015] [Accepted: 01/29/2015] [Indexed: 12/30/2022] Open
Abstract
Purpose The purpose of this study was to compare the mechanical stability of three types of plate systems for opening wedge high tibial osteotomy. Materials and Methods Forty-eight fresh frozen porcine tibia specimens were assigned to three different fixation device groups: Aescular group (16 specimens) was fixed with Aescular plates; Puddu group (16 specimens) with a Puddu plate, and TomoFix group (16 specimens) with a TomoFix plate. We compared axial displacements under compression loads from 200 to 2,000 N and maximal loads at failure among 8 specimens per group. We also compared displacements under cyclic load after 100 cycles at a compressive load of 2,000 N among 8 specimens per group. Results In all three groups, displacement under compression load increased with the increase in the axial compressive load; however, no significant intergroup differences were observed in the mean values under tested loading conditions. The mean maximal loads at failure were not significantly different (6,055, 6,798, and 6,973 N in the Aescular, Puddu, and TomoFix groups, respectively; p=0.41). While the TomoFix group showed less extension and strain during the cyclic load test, the mean values showed no significant differences among groups. Conclusions All three plate systems were found to provide fixation stability suitable for bearing axial compression and cyclic loads while walking.
Collapse
Affiliation(s)
- Kug Jin Kim
- Department of Orthopedic Surgery, Wolchul Ki-Chan Hospital, Yeongam, Korea
| | - Eun Kyoo Song
- Department of Orthopedic Surgery, Center for Joint Disease, Chonnam National University Hwasun Hospital, Hwasun, Korea
| | - Jong Keun Seon
- Department of Orthopedic Surgery, Center for Joint Disease, Chonnam National University Hwasun Hospital, Hwasun, Korea
| | - Jong Hwan Seol
- Department of Orthopedic Surgery, Center for Joint Disease, Chonnam National University Hwasun Hospital, Hwasun, Korea
| |
Collapse
|
12
|
Abstract
High tibial osteotomy (HTO) is a widely accepted and performed procedure to treat medial knee arthrosis. The aim of this review is to evaluate the different surgical options in medial knee arthrosis, focusing on indications, patient's selection, long-term follow-up and survival analysis of HTO. Comparison and pooling of results are challenging because of different evaluation systems, small cohort number, and different surgical techniques. No differences have been described between opening and closing wedged HTO in terms of outcomes. Excellent early survivorship and good clinical outcomes were reported also with concomitant procedures. Correct indications, preoperative workup/planning, and technique selection are essential in achieving good results. The choice between opening and closing wedge osteotomy, graft selection in opening wedge HTO, comparison between HTO and unicompartmental knee arthroplasty, and the results of revised HTO to total knee replacement are currently under debate and will be discussed in the present review.
Collapse
Affiliation(s)
- Davide Edoardo Bonasia
- Department of Orthopaedics, University of Torino, CTO Hospital, Via Lamarmora 26, 10128, Torino, Italy,
| | | | | | | | | |
Collapse
|
13
|
Golovakhа ML, Orljanski W, Benedetto KP, Panchenko S, Büchler P, Henle P, Aghayev E. Comparison of theoretical fixation stability of three devices employed in medial opening wedge high tibial osteotomy: a finite element analysis. BMC Musculoskelet Disord 2014; 15:230. [PMID: 25012591 PMCID: PMC4105235 DOI: 10.1186/1471-2474-15-230] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/10/2014] [Accepted: 06/25/2014] [Indexed: 01/30/2023] Open
Abstract
Background Medial open wedge high tibial osteotomy is a well-established procedure for the treatment of unicompartmental osteoarthritis and symptomatic varus malalignment. We hypothesized that different fixation devices generate different fixation stability profiles for the various wedge sizes in a finite element (FE) analysis. Methods Four types of fixation were compared: 1) first and 2) second generation Puddu plates, and 3) TomoFix plate with and 4) without bone graft. Cortical and cancellous bone was modelled and five different opening wedge sizes were studied for each model. Outcome measures included: 1) stresses in bone, 2) relative displacement of the proximal and distal tibial fragments, 3) stresses in the plates, 4) stresses on the upper and lower screw surfaces in the screw channels. Results The highest load for all fixation types occurred in the plate axis. For the vast majority of the wedge sizes and fixation types the shear stress (von Mises stress) was dominating in the bone independent of fixation type. The relative displacements of the tibial fragments were low (in μm range). With an increasing wedge size this displacement tended to increase for both Puddu plates and the TomoFix plate with bone graft. For the TomoFix plate without bone graft a rather opposite trend was observed. For all fixation types the occurring stresses at the screw-bone contact areas pulled at the screws and exceeded the allowable threshold of 1.2 MPa for at least one screw surface. Of the six screw surfaces that were studied, the TomoFix plate with bone graft showed a stress excess of one out of twelve and without bone graft, five out of twelve. With the Puddu plates, an excess stress occurred in the majority of screw surfaces. Conclusions The different fixation devices generate different fixation stability profiles for different opening wedge sizes. Based on the computational simulations, none of the studied osteosynthesis fixation types warranted an intransigent full weight bearing per se. The highest fixation stability was observed for the TomoFix plates and the lowest for the first generation Puddu plate. These findings were revealed in theoretical models and need to be validated in controlled clinical settings.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Emin Aghayev
- Institute for Evaluative Research in Medicine, University of Bern, Stauffacherstrasse 78, Bern 3014, Switzerland.
| |
Collapse
|
14
|
Medial opening-wedge high tibial osteotomy fixation with short plate without any graft, synthetic material or spacer. EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY 2014; 24:1549-55. [DOI: 10.1007/s00590-014-1417-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2013] [Accepted: 01/10/2014] [Indexed: 10/25/2022]
|
15
|
Wähnert D, Stolarczyk Y, Hoffmeier KL, Raschke MJ, Hofmann GO, Mückley T. Long-term stability of angle-stable versus conventional locked intramedullary nails in distal tibia fractures. BMC Musculoskelet Disord 2013; 14:66. [PMID: 23425016 PMCID: PMC3598499 DOI: 10.1186/1471-2474-14-66] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2012] [Accepted: 02/19/2013] [Indexed: 11/10/2022] Open
Abstract
Background In the last years intramedullary nailing has become the treatment of choice for most displaced diaphyseal tibia fractures. In contrast intramedullary nailing of distal tibia fractures is accompanied by problems like decreased biomechanical stability. Nevertheless the indications for intramedullary nailing have been extended to include even more distal fractures. The purpose of this study was to compare long-term mechanical characteristics of angle-stable versus conventional locked intramedullary nails in the treatment of unstable distal tibia fractures. Therefore, the effect of time on the mechanical properties of biodegradable sleeves was assessed. Methods 8 pairs of fresh, frozen porcine tibiae were used. The expert tibial nail (Synthes) was equipped with either three conventional locking screws (CL) or the angle-stable locking system (AS), consisting of a special ASLS screw and a biodegradable sleeve. Biomechanical testing included torsional and axial loading at different time-points over 12 weeks. Results The AS group showed a significantly higher torsional stiffness at all time-points (at least 60%) compared to the CL group (p < 0.001). The neutral zone was at least 5 times higher in the CL group (p < 0.001). The mean axial stiffness was maximum 10% higher (week 6) in the angle-stable locked group compared to the conventional group. There was no significant change of the torsional mechanical characteristics over the 12 weeks in both groups (p > 0.05). For axial stiffness and range of motion significant differences were found in the AS group. Conclusions The angle-stable locking system (ASLS) with the biodegradable sleeve provides significantly higher long-term stability. Especially the differences determined under torsional loading in this study may have clinical relevance. The ASLS permits the potential to decrease complications like secondary loss of reduction and mal-/non-union.
Collapse
Affiliation(s)
- Dirk Wähnert
- Department of Trauma-, Hand- and Reconstructive Surgery, Friedrich Schiller University Jena, Erlanger Allee 101, Jena 07747, Germany.
| | | | | | | | | | | |
Collapse
|
16
|
Bovine xenograft locking Puddu plate versus tricalcium phosphate spacer non-locking Puddu plate in opening-wedge high tibial osteotomy: a prospective double-cohort study. INTERNATIONAL ORTHOPAEDICS 2013; 37:819-26. [PMID: 23412369 DOI: 10.1007/s00264-013-1817-5] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2013] [Accepted: 01/27/2013] [Indexed: 10/27/2022]
Abstract
PURPOSE The aim of the study was to compare clinical and radiographic outcomes of opening-wedge high tibial osteotomy (HTO) augmented with either xenograft or tricalcium phosphate spacer for the management of medial compartment osteoarthritis (OA) with genu varum. METHODS Between 2004 and 2007, we prospectively enrolled 52 patients with medial compartment knee OA who underwent opening-wedge HTO fixed with locking Puddu plate and xenograft (n = 26) or non-locking Puddu plate and tricalcium phosphate spacer (n = 26). The alignment of the lower limb was assessed by measuring the hip-knee-ankle (HKA) angle. Clinical outcomes were assessed with the Knee Society Score, Western Ontario and McMaster Universities Osteoarthritis Index, SF-36 and European Quality of Life-5 Dimensions scale. All patients were followed up at six weeks and at three, six, 12 and 24 months post-operatively. Clinical outcomes were assessed preoperatively and at 24 months post-operatively. RESULTS All clinical scores improved significantly in both groups after surgery, without any significant difference between the two groups. Immediately after surgery, the HKA angle went from 9.1 ± 5.2° in varus to 3.1 ± 4.8° in valgus (P = 0.01) in the xenograft group, and from 8.5 ± 5.9° in varus to 3.4 ± 4.2° in valgus (P = 0.01) in the tricalcium phosphate group. At the last follow-up, the tricalcium phosphate group showed a significant loss of correction (P = 0.03). CONCLUSIONS HTO performed with xenograft locking plate and tricalcium phosphate non-locking plate constructs showed good clinical outcomes. However, the xenograft locking plate construct is superior to the tricalcium phosphate spacer non-locking plate to prevent the loss of correction in the middle term.
Collapse
|
17
|
Pape D, Madry H. The preclinical sheep model of high tibial osteotomy relating basic science to the clinics: standards, techniques and pitfalls. Knee Surg Sports Traumatol Arthrosc 2013; 21:228-36. [PMID: 22820740 DOI: 10.1007/s00167-012-2135-y] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2012] [Accepted: 07/02/2012] [Indexed: 11/27/2022]
Abstract
PURPOSE To develop a preclinical large animal model of high tibial osteotomy to study the effect of axial alignment on the lower extremity on specific issues of the knee joint, such as in articular cartilage repair, development of osteoarthritis and meniscal lesions. Preoperative planning, surgical procedure and postoperative care known from humans were adapted to develop a HTO model in the adult sheep. METHODS Thirty-five healthy, skeletally mature, female Merino sheep between 2 and 4 years of age underwent a HTO of their right tibia in a medial open-wedge technique inducing a normal (group 1) and an excessive valgus alignment (group 2) and a closed-wedge technique (group 3) inducing a varus alignment with the aim of elucidating the effect of limb alignment on cartilage repair in vivo. Animals were followed up for 6 months. RESULTS Solid bone healing and maintenance of correction are most likely if the following surgical principles are respected: (1) medial and longitudinal approach to the proximal tibia; (2) biplanar osteotomy to increase initial rotatory stability regardless of the direction of correction; (3) small, narrow but long implant with locking screws; (4) posterior plate placement to avoid slope changes; (5) use of bicortical screws to account for the brittle bone of the tibial head and to avoid tibial head displacement. CONCLUSION Although successful high tibial osteotomy in sheep is complex, the sheep may--because of its similarities with humans--serve as an elegant model to induce axial malalignment in a clinically relevant environment, and osteotomy healing under challenging mechanical conditions.
Collapse
Affiliation(s)
- Dietrich Pape
- Department of Orthopaedic Surgery, Centre Hospitalier de Luxembourg, 1460, Luxembourg, Luxembourg.
| | | |
Collapse
|
18
|
Han SB, Lee DH, Shetty GM, Chae DJ, Song JG, Nha KW. A "safe zone" in medial open-wedge high tibia osteotomy to prevent lateral cortex fracture. Knee Surg Sports Traumatol Arthrosc 2013; 21:90-5. [PMID: 22009558 DOI: 10.1007/s00167-011-1706-7] [Citation(s) in RCA: 94] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2010] [Accepted: 10/06/2011] [Indexed: 10/16/2022]
Abstract
PURPOSE The purpose of this cadaveric study was to study the effect of plane of osteotomy on incidence of lateral cortex fracture and to define a "safe zone" through which medial open-wedge high tibial osteotomy (HTO) could be performed with minimal risk of lateral cortex fracture. METHODS Medial open HTO was performed in nine fresh frozen human cadavers (18 knees) with each specimen randomly assigned to a "safe zone" osteotomy (group A, between the tip of the fibular head and the circumference line of the fibular head), or a lower level osteotomy (group B, distal to the circumference line of the fibular head). RESULTS Six out of nine knees developed lateral cortex fracture in group B compared to none in group A (P = 0.009) when the osteotomy site was distracted to a maximum of 20 mm. CONCLUSION Directing the plane of the osteotomy toward the "safe zone" significantly reduces the risk of lateral cortex fracture compared to an osteotomy, which is directed at a lower level. Confining the plane of a medial open HTO to within the "safe zone" can prevent lateral cortex fracture and subsequent loss of correction.
Collapse
Affiliation(s)
- Seung Boem Han
- Department of Orthopaedic Surgery, Ilsanpaik Hospital, Inje University, Ilsan, Korea
| | | | | | | | | | | |
Collapse
|
19
|
Wähnert D, Stolarczyk Y, Hoffmeier KL, Raschke MJ, Hofmann GO, Mückley T. The primary stability of angle-stable versus conventional locked intramedullary nails. INTERNATIONAL ORTHOPAEDICS 2011; 36:1059-64. [PMID: 22127384 DOI: 10.1007/s00264-011-1420-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2011] [Accepted: 11/06/2011] [Indexed: 11/24/2022]
Abstract
PURPOSE The aim of this study was to compare the initial biomechanical characteristics of the angle-stable locking system for intramedullary nails using the new biodegradable sleeve with conventional locking in the treatment of unstable distal tibial fractures. METHODS Eight pairs of fresh, frozen porcine tibiae were used for this study. The expert tibial nail (Synthes) was equipped with either conventional locking screws (CL) or the angle-stable locking system (AS). This system consists of a special ASLS screw with a biodegradable sleeve. For this investigation distal tibias (5.5 cm) were used and the nails were locked with three screws in both groups. Biomechanical testing included non-destructive torsional and axial loading. RESULTS The AS group showed a significantly higher torsional stiffness (70%) compared to the CL group. The range of motion was 0.5 times smaller for the AS constructs. The neutral zone was eight times higher in the CL group (p < 0.001). In axial loading the AS group also showed a 10% higher axial stiffness and a 12% lower range of motion (p < 0.001). CONCLUSION The angle-stable locking system (ASLS) using a special screw and sleeve locking for intramedullary nails provides a significantly higher primary stability. The differences determined in this study may have clinical relevance particularly for torsional loads. For the new biodegradable angle-stable sleeve we found a comparable stability to the PEEK-based sleeve system. This system has the potential to decrease complications such as secondary loss of reduction and mal-/non-union.
Collapse
Affiliation(s)
- Dirk Wähnert
- Department of Trauma-, Hand- and Reconstructive Surgery, Friedrich Schiller University Jena, Erlanger Allee 101, 07747, Jena, Germany.
| | | | | | | | | | | |
Collapse
|
20
|
Gomoll AH. High tibial osteotomy for the treatment of unicompartmental knee osteoarthritis: a review of the literature, indications, and technique. PHYSICIAN SPORTSMED 2011; 39:45-54. [PMID: 22030940 DOI: 10.3810/psm.2011.09.1920] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
In the past decades, there has been varying support for high tibial osteotomy. This surgical procedure was originally popularized by Mark B. Coventry, MD in the 1960s, but fell out of favor with orthopedic surgeons as knee arthroplasty became more commonplace. In the past 10 years, osteotomy has been rediscovered as an important adjunct to cartilage repair procedures that rely on a normalized biomechanical environment. Furthermore, there has been an increase in the number of patients presenting with unicompartmental disease (eg, after prior meniscectomy) who are at an age and functional level that is not ideally suited for joint arthroplasty. High tibial osteotomy allows 70% to 85% of patients to delay arthroplasty for ≥ 5 to 10 years and 50% to 60% for ≥ 15 years. This article provides an overview of the indications, technique, complications, and outcomes of high tibial osteotomy, specifically the more commonly used opening wedge technique.
Collapse
Affiliation(s)
- Andreas H Gomoll
- Department of Orthopaedic Surgery, Brigham and Women's Hospital, Harvard Medical School, Chestnut Hill, MA, USA.
| |
Collapse
|
21
|
Early complications of medial opening wedge high tibial osteotomy using autologous tricortical iliac bone graft and T-plate fixation. Knee 2011; 18:278-84. [PMID: 20801046 DOI: 10.1016/j.knee.2010.05.009] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2009] [Revised: 05/15/2010] [Accepted: 05/17/2010] [Indexed: 02/02/2023]
Abstract
Despite several advantages of medial opening wedge high tibial osteotomy, this procedure has been noted to have a high rate of complications especially with the use of a spacer plate for fixation. We retrospectively evaluated the early complications of 138 medial opening wedge high tibial osteotomies done using autologous tricortical iliac bone graft and T-plate fixation(AO locking compression T-plate, Ti/3H 4.5-5.0 mm, Synthes, Switzerland, Model No. 440.131 in 30 and low-profile locking T-plate and low-profile locking T-plate in 128 patients. At a mean follow-up of 36.8 months (13 to 78), 26 knees (18.8%) developed complications. Complications varied from osteotomy site infection, loss of correction, broken screws and lateral tibial plateau fracture to joint fluid leakage, pseudoaneurysm and iliac bone fractures. Using the "safe zone" technique and penetrating the lateral cortex with Steinmann pins may help to avoid complications such as loss of correction and lateral tibial plateau fractures. The results of this study indicate that medial opening wedge high tibial osteotomy using autologous tricortical iliac bone graft and T-plate fixation may be a technically demanding procedure associated with a moderate rate of complications. However, these complications could be minimized with proper planning, adequate intra-operative precautions and few modifications to avoid technical error.
Collapse
|
22
|
Efe T, Ahmed G, Heyse TJ, Boudriot U, Timmesfeld N, Fuchs-Winkelmann S, Ishaque B, Lakemeier S, Schofer MD. Closing-wedge high tibial osteotomy: survival and risk factor analysis at long-term follow up. BMC Musculoskelet Disord 2011; 12:46. [PMID: 21320313 PMCID: PMC3046001 DOI: 10.1186/1471-2474-12-46] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2010] [Accepted: 02/14/2011] [Indexed: 12/16/2022] Open
Abstract
Background Closing-wedge high tibial osteotomy (HTO) is successful for the treatment of medial osteoarthritis with varus malalignment. Preoperative risk factors for HTO failure are still controversial. The aim of this study was to elucidate the outcome and assess the influence of risk factors on long term HTO survival. Methods 199 patients were retrospectively studied with a mean follow-up period of 9.6 years after HTO. HTO failure was defined as the need for conversion to TKA. Survival was analyzed with the Kaplan-Meier method. Knee function was evaluated by the Hospital for Special Surgery (HSS) score. HTO-associated complications were also assessed. Univariate, multivariate, and logistic regression analysis were performed to evaluate the influence of age, gender, BMI, preoperative Kellgren-Lawrence osteoarthritis grade, and varus angle on HTO failure. Results 39 complications were recorded. Thus far, 36 HTOs were converted to TKA. The survival of HTO was 84% after 9.6 years. Knee function was considered excellent or good in 64% of patients. A significant preoperative risk factor for HTO failure was osteoarthritis, Kellgren-Lawrence grade >2. Conclusion HTO provides good clinical results in long-term follow-up. Preoperative osteoarthritis Kellgren-Lawrence grade >2 is a significant predictive risk factor for HTO failure. Results of HTO may be improved by careful patient selection. Complications associated with HTO should not be underestimated.
Collapse
Affiliation(s)
- Turgay Efe
- Department of Orthopaedics and Rheumatology, University Hospital Marburg, Baldingerstrasse, 35043 Marburg, Germany.
| | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Pape D, Lorbach O, Schmitz C, Busch LC, Van Giffen N, Seil R, Kohn DM. Effect of a biplanar osteotomy on primary stability following high tibial osteotomy: a biomechanical cadaver study. Knee Surg Sports Traumatol Arthrosc 2010; 18:204-11. [PMID: 19809806 DOI: 10.1007/s00167-009-0929-3] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2009] [Accepted: 09/08/2009] [Indexed: 11/30/2022]
Abstract
Open-wedge high tibial osteotomy (HTO) is becoming increasingly popular for the treatment of varus gonarthrosis in the active patient. The various implants used in HTO differ with regard to its design, the fixation stability and osteotomy technique. It is assumed that the combination of a plate fixator with a biplanar, v-shaped osteotomy supports bone healing. So far, there are no biomechanical studies that quantify the stabilizing effect of a biplanar versus uniplanar osteotomy. We hypothesized that a significant increase in primary stability of bone-implant constructs is achieved when using a biplanar as opposed to a uniplanar osteotomy. Twenty-four fresh-frozen human tibiae were mounted in a metal cylinder, and open-wedge osteotomy (12 mm wedge size) was performed in a standardized fashion. Proximal and distal tibial segments were marked with tantalum markers of 0.8 mm diameter. Two different plates with locking screws were used for fixation: a short spacer plate (group 1, n = 12) and a plate fixator (group 2, n = 12). In six specimens of each group, a biplanar V-shaped osteotomy with a 110 degrees angulated anterior cut behind the tuberosity parallel to the ventral tibial shaft axis was performed. In the remaining six specimens of each group, a simple uniplanar osteotomy was performed in an oblique fashion. Axial compression of the tibiae was performed using a material testing machine under standardized alignment of the loading axis. Load-controlled cyclical staircase loading tests were performed. The specimens were radiographed simultaneously in two planes together with a biplanar calibration cage in front of a film plane with and without load after each subcycle. Radiostereometry allowed for serial quantification of plastic and elastic micromotion at the osteotomy site reflecting the stability provided by the combination of implant and osteotomy technique. No significant additional stabilizing effect of a biplanar osteotomy in craniocaudal and mediolateral plane was found. However, additional stability was achieved in anteroposterior (AP) and all rotational planes in those specimens fixated with a short spacer plate. In this biomechanical set-up with axial load, the additional stabilizing effect of a biplanar osteotomy did not come into effect in the presence of a long and rigid plate fixator. However, biplanar osteotomy increased the fixation stability significantly in AP and rotational planes when a short spacer plate was used. Clinically, the biplanar osteotomy promotes bone healing regardless of the implant used. Biomechanically, biplanar osteotomy is advantageous for shorter plate designs to increase primary stability of the bone-implant construct.
Collapse
Affiliation(s)
- Dietrich Pape
- Centre de l'Appareil Locomoteur, de Medecine du Sport et de Prevention, Centre Hospitalier de Luxembourg, Clinique d'Eich, 78, rue d'Eich, 1460, Luxembourg, Luxembourg.
| | | | | | | | | | | | | |
Collapse
|
24
|
Amendola A, Bonasia DE. Results of high tibial osteotomy: review of the literature. INTERNATIONAL ORTHOPAEDICS 2009; 34:155-60. [PMID: 19838706 DOI: 10.1007/s00264-009-0889-8] [Citation(s) in RCA: 257] [Impact Index Per Article: 17.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2009] [Accepted: 09/23/2009] [Indexed: 01/09/2023]
Abstract
The aim of this review is to evaluate long-term follow-up and survival analysis studies regarding high tibial osteotomies (HTO) for the treatment of medial knee arthritis. Despite the good number of studies available, comparison and pooling of the results are challenging because of the different evaluation systems and techniques used. However, in general, published studies on HTO report good long-term results with a correct patient selection and a precise surgical technique. Based on our findings, the ideal candidate for an HTO is a young patient (<60 years of age), with isolated medial osteoarthritis, with good range of motion and without ligamentous instability. Furthermore, the literature review shows that the outcomes gradually deteriorate with time. Nevertheless, some issues remain that need resolution; these include the choice between opening or closing wedge tibial osteotomy, the graft selection in opening wedge osteotomies, the type of fixation, the comparison with unicompartmental knee arthroplasty and whether HTO significantly affects a subsequent total joint replacement.
Collapse
Affiliation(s)
- Annunziato Amendola
- Orthopaedic Surgery, University of Iowa Sports Medicine Center, University of Iowa Hospitals and Clinics, 200 Hawkins Dr, Iowa City, IA 52242, USA.
| | | |
Collapse
|
25
|
Aryee S, Imhoff AB, Rose T, Tischer T. Do we need synthetic osteotomy augmentation materials for opening-wedge high tibial osteotomy. Biomaterials 2008; 29:3497-502. [PMID: 18555524 DOI: 10.1016/j.biomaterials.2008.05.027] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2008] [Accepted: 05/11/2008] [Indexed: 01/30/2023]
Abstract
High tibial osteotomy (HTO) is an increasing popular method to treat unicompartimental osteoarthritis of the knee in younger, active patients. In so doing one tries to delay the need for total or unicompartimental joint replacement. The augmentation of HTO opening gaps with supporting material is discussed controversially, especially after the introduction of locking plates, which contribute to the decline of the non-union rate. Currently, we do not recommend synthetic augmentation, when using locking plates in HTO with opening angles less than 10 degrees . In our recent randomized study we could histologically and radiologically demonstrate the complete rebuilding of lamelliform bone in patients without synthetic augmentation, whilst bony ingrowth into the hydroxyapatite/tricalcium phosphate (HA/TCP) wedge of augmented osteotomies just slowly progressed. In contrast to unaugmented osteotomies, there was no advantage in using HA/TCP wedges or the combination of HA/TCP wedges and platelet rich plasma (PRP) as supporting material after 12 months. In osteotomies where an opening angle bigger than 7.5 degrees is chosen, rigid locking plates should be used. In our opinion, autologous iliac crest graft should be used in the high-risk patients (obese, smoker, opening angle bigger than 10 degrees ). Whether synthetic augmentation combined with PRP is equal or even superior to autologous iliac crest graft in openings bigger than 10 degrees has not been proven yet.
Collapse
Affiliation(s)
- Sebastian Aryee
- Department of Orthopaedic Sport Medicine, Technical University of Munich, Germany
| | | | | | | |
Collapse
|
26
|
Dubrana F, Lecerf G, Nguyen-Khanh JP, Menard R, Ardouin L, Gibon Y, Pidhorz L, Falaise V, Coipeau P, Burdin P, Rouvillain JL, Navarre T, Garron E, Daoud W, Louboutin H, Moineau G, Wessely L, Stindel E, Debarge R, Lustig S, Lavoie F, Neyret P. Ostéotomie tibiale de valgisation. ACTA ACUST UNITED AC 2008; 94:S2-21. [DOI: 10.1016/j.rco.2008.03.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
27
|
Kombinationseingriffe. ARTHROSKOPIE 2008. [DOI: 10.1007/s00142-007-0421-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
28
|
|
29
|
Raymond LD, Laflamme GY, Ranger P, Zhim F, Girard J. [Open-wedge retro-tubercular tibial osteotomy: an innovating technique]. REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L'APPAREIL MOTEUR 2007; 93:588-593. [PMID: 18065868 DOI: 10.1016/s0035-1040(07)92681-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Open-wedge tibial osteotomy for varus correction is a common orthopedic procedure. The rate of complications remains significant: loss of correction, nonunion, patellar infera... We propose a new open-wedge technique for tibial osteotomy which has several advantages: less risk of patella infera, improved bone healing, excellent mechanical stability. The osteotomy involves two cuts with an anterior portion ending distally to the tibial tubercle. This preserves the integrity of the patellar tendon and maintains contact between the proximal tibia and the tibial tubercle. Adjunction of an anteroposterior screw adds stability. The anterior plane of the osteotomy provides an excellent surface contact favoring bone healing. The posterior plane is the same as with a "classical" open-wedge osteotomy. The lateral cortical must always remain intact (hinge). The technique described here does not require any specific instrumentation and is compatible with most of the available osteosynthesis implants.
Collapse
Affiliation(s)
- L D Raymond
- Programme d'Orthopédie Edouard-Samson, Hôpital du Sacré-Coeur de Montréal, 5400 boulevard, Gouin-Ouest, Montréal (Qc), H4J 1C5, Canada
| | | | | | | | | |
Collapse
|
30
|
Esenkaya I, Misirlioglu M, Kelestemur MH, Elmali N, Fadillioglu E. Biomechanical evaluation of different fixation plates in medial opening upper tibial osteotomy. Knee 2007; 14:46-50. [PMID: 17113296 DOI: 10.1016/j.knee.2006.10.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/28/2006] [Revised: 08/11/2006] [Accepted: 10/09/2006] [Indexed: 02/02/2023]
Abstract
In this biomechanical study, 25 in vitro calf tibial models were used in order to compare the stability of the plates under axial compression loading. A 10-mm medial opening gap was stabilized in each of the five calf tibial models either with four or two-holed rectangular shaped plates with wedges, with four-holed reversed L-shaped plates with wedges, with the combination of these two types of plates, or with six-holed anatomical T-plates. The compression behavior of the model was tested by using a universal mechanical testing system. The specimens fixed with the combination of plates with the four-holed reversed L-shaped and with two-holed rectangular shaped; or with six-holed anatomical T-plates, showed significantly better stability than those of others. Four different kinds of failure (slippage of wedge, lateral cortex fracture, damage and/or loosening of screws, and bending of plates) were observed on the models. When the average value of force loading on the plates that were designed by the first author was considered, the plates were stable and the average force values at these points were higher than the loading force on a knee during the normal paced walking or running conditions.
Collapse
Affiliation(s)
- Irfan Esenkaya
- Inonu University, School of Medicine, Department of Orthopaedics and Traumatology, 44065, Malatya, Turkey.
| | | | | | | | | |
Collapse
|