1
|
Feng T, Tang H, Zhang X, Zhang Y, Zhou Y, Jin Z. A novel algorithm to efficiently calculate the impingement-free range of motion of irregularly-shaped total hip arthroplasty components. J Orthop Res 2023; 41:2516-2529. [PMID: 37132499 DOI: 10.1002/jor.25585] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Revised: 04/18/2023] [Accepted: 05/01/2023] [Indexed: 05/04/2023]
Abstract
There is great difficulty in quickly calculating the impingement-free range of motion (IFROM) of hip components with complex shapes after total hip arthroplasty. We have established a new algorithm to investigate the effect of different shapes of hip components on the IFROM and impingement-free safe zone (IFSZ). Then find the best combination of hip prosthesis and the optimal mounting position of the elevated-rim liner under different radiographic anteversion (RA) and radiographic inclination (RI) of the cup. We found the larger the opening angle of the beveled-rim liner and the smaller the cross-sectional area of the stem neck with an inverted teardrop cross-sectional shape, the greater the IFROM of the hip component. The beveled-rim liner in combination with the stem neck with an inverted teardrop-shaped cross-section could provide the greatest IFSZ (excluding the flat-rim liner). The optimal orientation of the elevated-rim liner was the posterior-inferior side (RI ≤ 37°), posterior-superior side (RI ≥ 45°), and posterior side (37° ≤ RI ≤ 45°). Our novel algorithm provides a solution to analyze the IFROM of any hip prosthesis with any complex shape. The shape and size of the cross-section of the stem neck, the orientation of the elevated rim, and the shape and opening angle of the liner are all critical factors for the quantitative calculation of the IFROM and mounting safe zone of the prosthesis. Stem necks with inverted teardrop cross-section and beveled-rim liner improved the IFSZ. The optimal direction of the elevated rim is not constant but varies with RI and RA.
Collapse
Affiliation(s)
- Tao Feng
- Tribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China
| | - Hao Tang
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Xiaogang Zhang
- Tribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China
| | - Yali Zhang
- Tribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China
| | - Yixin Zhou
- Department of Orthopaedic Surgery, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, Beijing, China
| | - Zhongmin Jin
- Tribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China
- School of Mechanical Engineering, University of Leeds, Leeds, UK
| |
Collapse
|
2
|
Ismail NF, Shuib S, Manap MFA. Study of Stress Distribution at the Inner Surface of Uncemented Total Hip Replacement (THR). 2023 IEEE 14TH CONTROL AND SYSTEM GRADUATE RESEARCH COLLOQUIUM (ICSGRC) 2023. [DOI: 10.1109/icsgrc57744.2023.10215416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
Affiliation(s)
- Nur Faiqa Ismail
- Management and Science University,Faculty of Information Sciences and Engineering,Shah Alam,Selangor,Malaysia
| | - Solehuddin Shuib
- University Teknologi MARA,College of Engineering,School of Mechanical Engineering,Shah Alam,Selangor,Malaysia
| | - Muhammad Faris Abd Manap
- University Teknologi MARA,College of Engineering,Mechanical Engineering Studies,Permatang Pauh,Pulau Pinang,Malaysia
| |
Collapse
|
3
|
Sivaloganathan S, Blakeney WG, Rivière C, Vendittoli PA. Evolution of Concepts: Can Personalized Hip Arthroplasty Improve Joint Stability? J Clin Med 2023; 12:jcm12093324. [PMID: 37176765 PMCID: PMC10179336 DOI: 10.3390/jcm12093324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/25/2023] [Accepted: 05/01/2023] [Indexed: 05/15/2023] Open
Abstract
Hip arthroplasty procedures are successful and reproducible. However, within the first two post-operative years, hip dislocations are the most common cause for revisions. This is despite the majority of the dislocations having the acetabular component within what is described as the 'safe zone'. The limitations of such boundaries do not take into account the variability of individual hip anatomy and functional pelvic orientation that exist. An alternative concept to address hip instability and improve overall outcomes is functional acetabular orientation. In this review article, we discuss the evolution of concepts, particularly the kinematic alignment technique for hip arthroplasty and the use of large-diameter heads to understand why total hip arthroplasty dislocations occur and how to prevent them.
Collapse
Affiliation(s)
| | - William G Blakeney
- Department of Orthopedic Surgery, Royal Perth Hospital, Perth, WA 6000, Australia
| | - Charles Rivière
- Clinique de Sport Bordeaux-Mérignac, Bordeaux Arthroplasty Research Institute, Personalized Arthroplasty Society, 33700 Mérignac, France
| | - Pascal-André Vendittoli
- Hôpital Maisonneuve-Rosemont, Clinique Orthopédique Duval, Personalized Arthroplasty Society, Montréal, QC H1T 2M4, Canada
| |
Collapse
|
4
|
The Impact of Varying Femoral Head Length on Hip External Rotation During Posterior-approach Total Hip Arthroplasty. Arthroplast Today 2023; 19:101072. [PMID: 36624748 PMCID: PMC9823119 DOI: 10.1016/j.artd.2022.101072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Revised: 10/28/2022] [Accepted: 11/17/2022] [Indexed: 01/05/2023] Open
Abstract
Background Prior investigations of total hip arthroplasty (THA) have studied the effects of prosthetic femoral head size and stem offset on hip range of motion (ROM), impingement risk, and overall hip stability to optimize the return to activities of daily living. However, the relationship between femoral head length and hip ROM, specifically external rotation (ER), has not been evaluated. The aim of our study was to intraoperatively assess how femoral head length affects hip ROM during a posterior approach THA. Methods Thirty-two patients undergoing a primary elective THA through a posterior approach were prospectively included. After final femoral stem insertion, femoral head trials were performed using the targeted head length, followed by the shorter (-3.0 to -3.5 mm) and longer (+3.0 to +4.0 mm) head length configurations. At each length, hip ER was measured using an intraoperative goniometer from an imageless navigation system. ER values across the three head lengths were compared using a repeated-measures analysis of variance and paired t-tests. Results Varying femoral head lengths demonstrated a statically significant and reproducible effect on intraoperative ER range (analysis of variance; P < .001) in each patient. An increased femoral head length (mean 3.4 mm) significantly decreased (P < .001) ER range by 10.8 ± 3.3° while a shortened femoral head length (mean 3.5 mm) significantly increased (P < .001) the ER ROM by 6.0 ± 3.8°. Conclusions The results of this study demonstrate the sensitivity of hip ROM to incremental changes in femoral head length. As ER is important for activities of daily living, inadvertent lengthening should be avoided.
Collapse
|
5
|
Association Between the Amount of Limb Lengthening and Hip Range of Motion After Total Hip Arthroplasty. J Am Acad Orthop Surg 2022; 30:e599-e606. [PMID: 35175976 DOI: 10.5435/jaaos-d-21-00374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 12/23/2021] [Indexed: 02/01/2023] Open
Abstract
AIMS The relationship between prosthetic position and range of motion (ROM) after total hip arthroplasty (THA) has been rigorously examined. However, the effects of limb lengthening on postoperative hip ROM remain unclarified. We aimed to examine the effect of limb lengthening on hip ROM after THA. METHODS We retrospectively reviewed the data from 120 patients who underwent unilateral THA. Univariate and multivariate regression models were used to evaluate the effects of the following patient- and surgery-related covariates on hip flexion ROM at 3, 6, and 12 months after THA: age, sex, body mass index, diagnosis, preoperative University of California Los Angeles activity score, preoperative Oxford Hip Score, preoperative flexion ROM, amount of leg lengthening, cup inclination, and cup anteversion. RESULTS A large preoperative hip flexion ROM was the strongest predictor of a large hip flexion ROM at 12 months after THA (standardized coefficient: 0.519, P < 0.0001). A larger amount of leg lengthening was associated with a smaller postoperative hip flexion ROM (standardized coefficient: -0.159, P = 0.039), and male sex was another predictor of a smaller postoperative hip flexion ROM (standardized coefficient: -0.204, P = 0.014). Cup inclination (P = 0.99) and anteversion (P = 0.18) were not significantly associated with hip flexion ROM at 12 months after THA. DISCUSSION A large amount of limb lengthening was associated with decreased hip flexion ROM after THA. In THA, minimizing the leg length discrepancy is important; however, the postoperative improvement in hip flexion ROM may be limited when a large amount of leg lengthening is needed.
Collapse
|
6
|
Kawai T, Goto K, Kuroda Y, Okuzu Y, Matsuda S. Discrepancy in the Responsiveness to Hip Range of Motion Between Harris and Oxford Hip Scores. Arthroplast Today 2022; 13:157-164. [PMID: 35097171 PMCID: PMC8783107 DOI: 10.1016/j.artd.2021.10.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Revised: 09/07/2021] [Accepted: 10/13/2021] [Indexed: 11/06/2022] Open
Abstract
Background The primary objectives of total hip arthroplasty (THA) include mobility improvement and pain relief; however, the correlation between hip range of motion (ROM) and function remains unclear. We aimed to explore how ROM affects hip functions after THA and compare the responsiveness of each component of the modified Harris Hip Score (mHHS) and Oxford Hip Score (OHS) to preoperative and postoperative ROM. Methods This prospective observational study involved 120 patients who underwent unilateral THA. Univariate regression analyses were performed using the University of California Los Angeles activity score and mHHS and OHS to determine the effects of preoperative and postoperative flex ROM on clinical scores at 12 months. Multivariate regressions were performed to adjust for the confounding effects of patient factors: age, sex, body mass index, and diagnosis. Results A larger preoperative flexion ROM was associated with a higher score in the mHHS socks component (standardized coefficient [SC] = 0.26, P = .0041) at 12 months; the effect on the OHS socks component was not significant (P = .34). A larger flexion ROM at 12 months was associated with higher scores in the mHHS support (SC = 0.21, P = .026), stairs (SC = 0.35, P = .0002), and socks (SC = 0.32, P = .0007) components but had no significant effect on any OHS component. The effects of ROM on University of California Los Angeles activity score were limited. Conclusions A discrepancy was noted in the responsiveness to ROM between the two major measurement tools; this difference might be because mHHS and OHS are surgeon- and patient-administered questionnaires, respectively. This discrepancy also suggests that the patients have higher satisfaction than that assumed by the surgeons.
Collapse
|
7
|
Kostretzis L, Lavigne M, Kiss MO, Shahin M, Barry J, Vendittoli PA. Despite higher revision rate, MoM large-head THA offers better clinical scores than HR: 14-year results from a randomized controlled trial involving 48 patients. BMC Musculoskelet Disord 2021; 22:400. [PMID: 33941155 PMCID: PMC8091753 DOI: 10.1186/s12891-021-04286-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Accepted: 04/22/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The high failure rates of metal on metal (MoM) large diameter head total hip arthroplasty (LDH THA) and hip resurfacing (HR) prevented their long-term comparisons with regards to clinical outcome. Such knowledge would be important as ceramic LDH bearing is now available. With long-term follow-up, we investigated the difference in 1) patient-reported outcome measures (PROMs); 2) revision and adverse events rates, and 3) metal ion levels between MoM LDH THA and HR. METHODS Forty-eight patients were randomized for LDH THA (24) or HR (24) with the same MoM articulation. At a mean follow-up of 14 years, we compared between groups different PROMs, the number of revisions and adverse events, whole blood Cobalt (Co) and Chromium (Cr) ion levels, and radiographic signs of implant dysfunction. RESULTS LDH THA (all cases: revised and well-functioning) had significantly better WOMAC (94 versus 85, p = 0.04), and more frequently reported having no limitation (p = 0.04). LDH THA revision rate was 20.8% (5/24) versus 8.3% (2/24) for HR (p = 0.4). Mean Co and Cr ion levels were higher in LDH THA compared to the HR (Co: 3.8 μg/L vs 1.7 μg/L; p = 0.04 and Cr: 1.9 μg/L vs 1.4 μg/L, p = 0.1). On radiographic analyses, 2 LDH THAs showed signs of adverse reaction to metal debris, whereas 1 loose femoral HR component was documented. CONCLUSION In the long-term, MoM LDH THA had a high trunnion related revision rate but nonetheless showed better PROMs compared to HR. Provided with a well-functioning modular junction, non-MoM LDH THA would offer an appealing option. TRIAL REGISTRATION ClinicalTrials.gov ( NCT04516239 ), August 18, 2020. Retrospectively registered.
Collapse
Affiliation(s)
- Lazaros Kostretzis
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada
| | - Martin Lavigne
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada
| | - Marc-Olivier Kiss
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada
| | - Maged Shahin
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada
| | - Janie Barry
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada
| | - Pascal-André Vendittoli
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, 5415 Boulevard de l'Assomption, Montréal, Québec, H1T 2M4, Canada.
| |
Collapse
|
8
|
Vendittoli PA, Shahin M, Rivière C, Roy AG, Barry J, Lavigne M. Hip Resurfacing Compared with 28-mm Metal-on-Metal Total Hip Replacement: A Randomized Study with 15 Years of Follow-up. J Bone Joint Surg Am 2020; 102:80-90. [PMID: 32554999 DOI: 10.2106/jbjs.20.00030] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Bone stock conservation, hip anatomy preservation, and greater stability are among the promoted advantages of hip resurfacing (HR). However, the disappointing failure of some implants nearly led to its abandonment. The aim of this study was to compare clinical scores and revision and complication rates after HR with those after total hip arthroplasty (THA). METHODS Two hundred and three hips were randomized to 28-mm metal-on-metal (MoM) THA (99 hips) or to HR (104 hips). Main outcome measures compared between groups were the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score, the revision rate, and the complication rates. The radiographic findings were also assessed. RESULTS After a mean follow-up of 15 years (range, 14 to 16 years), 9 (4.4%) of the 203 patients were lost to follow-up and 15 (7.4%) had died. The Kaplan-Meier survivorship, with revision for any reason as the end point, was 89.2% (95% confidence interval [CI], 82.3% to 96.1%) for HR and 94.2% (95% CI, 89.3% to 99.1%) for THA (p = 0.292). The reasons for revision included infection (3 patients), recurrent dislocation (1 patient), and adverse reaction to metal debris (ARMD) (1 patient) in the THA group and ARMD (2 patients) and femoral head loosening (7 patients) in the HR group. With aseptic revision as the end point, the Kaplan-Meier survivorship was significantly higher in the THA group (97.4% versus 89.2%; p = 0.033). No dislocation occurred in the HR group compared with 4 in the THA group (p = 0.058). Both groups achieved a similar mean WOMAC score (10.7 in the HR group and 8.8 in the THA group; p = 0.749), Forgotten Joint Score (87.1 and 85.3, respectively; p = 0.410), University of California Los Angeles (UCLA) activity score (6.3 and 6.4, respectively; p = 0.189), and overall joint perception (p = 0.251). CONCLUSIONS The specific HR and MoM 28-mm THA implants used in this study showed good long-term survival and function. The overall rates of complications and revisions were similar in both groups but were of different types. As it provides better femoral bone preservation and biomechanical reconstruction, HR may continue to have a role in selected patients when performed by experienced surgeons and using validated implants. LEVEL OF EVIDENCE Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Collapse
Affiliation(s)
- Pascal-André Vendittoli
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| | - Maged Shahin
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| | | | - Alain Guy Roy
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| | - Janie Barry
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| | - Martin Lavigne
- Surgery Department, Hôpital Maisonneuve-Rosemont, Montreal University, Montréal, Québec, Canada
| |
Collapse
|
9
|
Li G, Peng Y, Zhou C, Jin Z, Bedair H. The effect of structural parameters of total hip arthroplasty on polyethylene liner wear behavior: A theoretical model analysis. J Orthop Res 2020; 38:1587-1595. [PMID: 31876311 DOI: 10.1002/jor.24577] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/23/2019] [Accepted: 12/21/2019] [Indexed: 02/04/2023]
Abstract
Using large femoral heads in total hip arthroplasty (THA) has been widely advocated to improve the function and longevity of the components. However, increasing the head size has been shown to accelerate polyethylene liner wear. Few studies have investigated the effect of other important structural parameters (such as polyethylene liner thickness, metal cup size, head-liner conformity, loading conditions, etc.) on the biomechanical functions of the THAs. In this study, an analytical model was used to evaluate the polyethylene liner wear characteristics of the THAs (defined using a biomechanical wear factor) with various structural parameters of the THAs and loading conditions. For all the THA systems examined in this study, under the same loading conditions, a larger head leads to increasing contact areas, lower contact stresses, and higher biomechanical wear factors. When the head size is fixed, a decrease in the polyethylene liner thickness or a decrease in the head-liner conformity leads to higher peak contact stresses and smaller contact areas and consequently, lower biomechanical wear factors. This study provides a parametric analysis tool for the optimal design/selection of the THA systems and for prediction of early effects of various structural parameters on the biomechanical function (such as contact stresses) and longevity (such as polyethylene liner wear) of the THA systems.
Collapse
Affiliation(s)
- Guoan Li
- Department of Orthopaedic Surgery, Orthopaedic Bioengineering Research Center, Newton-Wellesley Hospital, Harvard Medical School, Newton, Massachusetts
| | - Yun Peng
- Department of Orthopaedic Surgery, Orthopaedic Bioengineering Research Center, Newton-Wellesley Hospital, Harvard Medical School, Newton, Massachusetts
| | - Chaochao Zhou
- Department of Orthopaedic Surgery, Orthopaedic Bioengineering Research Center, Newton-Wellesley Hospital, Harvard Medical School, Newton, Massachusetts.,Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| | - Zhongmin Jin
- Tribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, Sichuan, China.,Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| | - Hany Bedair
- Department of Orthopaedic Surgery, Orthopaedic Bioengineering Research Center, Newton-Wellesley Hospital, Harvard Medical School, Newton, Massachusetts.,Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
10
|
Kilb BKJ, Kurmis AP, Parry M, Sherwood K, Keown P, Masri BA, Duncan CP, Garbuz DS. Frank Stinchfield Award: Identification of the At-risk Genotype for Development of Pseudotumors Around Metal-on-metal THAs. Clin Orthop Relat Res 2018; 476. [PMID: 29529651 PMCID: PMC6259707 DOI: 10.1007/s11999.0000000000000028] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Once touted as the future of hip arthroplasty, metal-on-metal (MoM) bearing surfaces have fallen sharply from favor with the emergence of a strong body of evidence demonstrating unacceptably high premature implant failure rates. The previously unpredictable development of adverse local tissue reactions (ALTRs) has been a substantive contributor to this. Although the underlying pathophysiology of these so-called "pseudotumors" is now well understood, the fundamental predisposing patient risk factors have remained elusive. QUESTIONS/PURPOSES The aim of this research, as a clinical-genotype correlation analysis, was to identify specific alleles (genes) associated with the development of ALTRs in patients with in situ MoM THAs. METHODS A case-control study of patients who received a large-head, primary MoM THA between 2005 and 2008 was performed with a minimum followup of 5 years. Twenty-six patients who had undergone revision of a primary MoM THA secondary to symptomatic ALTRs were recruited. The mean timeframe from primary MoM THA to symptomatic revision was 5.5 years (range, 1-10 years). Twenty-eight control subjects were randomly selected asymptomatic patients with no evidence of ALTRs on protocol-specific screening. Baseline demographics and high-resolution genotype (human leukocyte antigen [HLA] Class II) were collected for all patients. Cohorts were similar with respect to age at the time of primary MoM THA (mean, 54.8 versus 54.9 years, p = 0.95) and serum cobalt (mean, 5.5 versus 8.5 μg/L, p = 0.09) and chromium concentrations (mean, 2.9 versus 4.2 μg/L, p = 0.27). The association between genotype and revision surgery secondary to ALTRs was determined with gender as a covariate. RESULTS The prevalence of the risk genotype was 30% (16 of 54) among the entire cohort. Adjusting for sex, the odds of revision were 6.1 times greater among patients with the risk genotype present than among patients without (95% confidence interval [CI], 1.5-25.4; p = 0.01). Among females, the specificity of the risk genotype was 1.0 (95% CIexact, 0.5-1.0; pexact = 0.03), and for males, it was 0.8 (95% CIexact, 0.6-0.9; pexact < 0.01). CONCLUSIONS The findings of this study suggest that, among patients with a primary MoM THA, allelic variation within the HLA Class II loci may be a strong, independent risk factor associated with the need for subsequent revision surgery secondary to pseudotumor formation. CLINICAL RELEVANCE Given the hypothesis-generating nature of this novel undertaking, confirmatory prospective clinical studies are required to further elucidate this correlation and to explore the clinical utility of targeted genetic screening in this specific population. This research may, however, represent a key missing piece in the puzzle that is metal ion-induced pseudotumor formation.
Collapse
Affiliation(s)
- Brett K J Kilb
- B. K. J. Kilb, A. P. Kurmis, M. Parry, B. A. Masri, C. P. Duncan, D. S., Garbuz Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada K. Sherwood, P. Keown Department of Pathology (&) Laboratory Medicine, University of British Columbia, Vancouver, British Columbia, Canada P. Keown, Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada A. P. Kurmis, Discipline of Medical Specialties, University of Adelaide, Adelaide, SA, Australia
| | | | | | | | | | | | | | | |
Collapse
|
11
|
Jamari J, Anwar IB, Saputra E, van der Heide E. Range of Motion Simulation of Hip Joint Movement During Salat Activity. J Arthroplasty 2017; 32:2898-2904. [PMID: 28499625 DOI: 10.1016/j.arth.2017.03.056] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2014] [Revised: 03/14/2017] [Accepted: 03/23/2017] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Impingement of an artificial hip joint because of limited range of motion (RoM) during human activity is one of the main sources of hip joint failure. The aim of this article is to simulate the RoMs of hip joints during salat, the practice of formal worship in Islam. METHODS Salat consists of several stages which can be represented with a cycle (raka'ah). Every raka'ah consists of standing, bowing (ruku'), straightening up (i'tidal), transition of standing toward prostrating, prostrating (sujud), and sitting. A virtual skeleton model was used to analyze the motion during salat for the possibility of the impingement occurrence. RESULTS The results of the simulation were presented in terms of maximum flexion, abduction, and internal or external rotation. The results also showed that the prostration position is similar in RoM with the Japanese zarei position and similar in RoM to pick up an object while sitting on a chair. CONCLUSION Specific aspects of salat such as the difference in position of the 2 legs at the last sitting position create an extreme RoM which in turn results in a high risk of impingement.
Collapse
Affiliation(s)
- J Jamari
- Laboratory for Engineering Design and Tribology, Department of Mechanical Engineering, Diponegoro University, Semarang, Indonesia
| | - Iwan Budiwan Anwar
- Orthopaedic and Traumatology Department, Prof Dr R. Soeharso Orthopaedic Hospital, Surakarta, Indonesia; Laboratory for Surface Technology and Tribology, Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands
| | - Eko Saputra
- Laboratory for Engineering Design and Tribology, Department of Mechanical Engineering, Diponegoro University, Semarang, Indonesia; Laboratory for Surface Technology and Tribology, Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands
| | - Emile van der Heide
- Laboratory for Surface Technology and Tribology, Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands
| |
Collapse
|
12
|
Konan S, Duncan CP, Masri BS, Garbuz DS. What Is the Natural History of Asymptomatic Pseudotumors in Metal-on-metal THAs at Mid-term Followup? Clin Orthop Relat Res 2017; 475:433-441. [PMID: 27444034 PMCID: PMC5213933 DOI: 10.1007/s11999-016-4981-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND The risk of early revision because of pseudotumors in patients who have undergone large-head metal-on-metal (MoM) total hip arthroplasty (THA) is well documented. However, the natural history of asymptomatic pseudotumors or of MoM articulations without pseudotumors is less well understood. The aim of our study was to investigate the natural history of primary MoM THA at mid-term followup. QUESTIONS/PURPOSES The purposes of this study were: (1) Did previously detected pseudotumors persist or worsen in asymptomatic patients at mid-term followup; and if so, did any of them require revision THA? (2) Did new pseudotumors form in asymptomatic patients at mid-term followup? (3) What happened to serum trace metal ions at mid-term followup? (4) Were postoperative patient-reported outcome measures (PROMs) maintained at mid-term followup? METHODS Seventy-one patients who underwent a MoM THA using a Metasul LDH implant with a Durom acetabular cup and an M/L Taper stem between September 2005 and October 2008 were reviewed. All patients for this study were part of two previously published studies from our early followup. Data from the previous studies were used for comparison only. Two of the 71 patients (2.8%) were lost to followup. The mean age at operation was 56 years (range, 34-68 years). There were 24 female patients. All patients had serum trace metal ions testing, ultrasound imaging, and PROMs at a mean 3.5 years (early followup) after the index operation (range, 3-5 years) and delayed followup at a mean 7 years (range, 6.5-9 years). The indication to undertake revision THA was based on clinical evaluation and not solely on the investigation results. RESULTS Twenty-three of 71 patients (32%) had a positive ultrasound scan for pseudotumor at early followup. Of these, eight patients underwent revision THA (11% of MoM THA or 35% of patients with an early positive ultrasound scan). The mean time between positive ultrasound scan and revision surgery was 13 months (range, 5-22 months). Of the remaining 15 patients with pseudotumor noted on early ultrasound, 12 had persistent pseudotumor, two resolved, and one was lost to followup. Six patients (13%) with a normal ultrasound scan at early followup showed new ultrasound findings at delayed followup. Of these, four (8%) were conclusively diagnosed as pseudotumor and one was revised. Serum trace metal ion increased at mid-term followup in the seven cases that showed an increase in volume of pseudotumor. Of the five patients in whom the volume of pseudotumor decreased on ultrasound at mid-term followup, three showed a decrease in serum trace ions levels, whereas two showed an increase. New-onset pseudotumors at mid-term followup was associated with an increase in serum trace metal ions at mid-term followup only in two of six cases. PROMs at mid-term followup of patients in this study remain high. CONCLUSIONS At mid-term followup, approximately 35% of patients who develop an early pseudotumor undergo revision arthroplasty, whereas the remaining are asymptomatic. The incidence of new-onset ultrasound findings suggestive of pseudotumors at mid- to long-term followup is approximately 8% and these require continued surveillance. LEVEL OF EVIDENCE Level II, prognostic study.
Collapse
Affiliation(s)
- Sujith Konan
- Department of Orthopaedics, Vancouver General Hospital, University of British Columbia, JP North 3rd Floor, Room 3114, 910 West 10th Avenue, Vancouver, BC, V5Z 4E3, Canada.
| | - Clive P Duncan
- Department of Orthopaedics, Vancouver General Hospital, University of British Columbia, JP North 3rd Floor, Room 3114, 910 West 10th Avenue, Vancouver, BC, V5Z 4E3, Canada
| | - Bassam S Masri
- Department of Orthopaedics, Vancouver General Hospital, University of British Columbia, JP North 3rd Floor, Room 3114, 910 West 10th Avenue, Vancouver, BC, V5Z 4E3, Canada
| | - Donald S Garbuz
- Department of Orthopaedics, Vancouver General Hospital, University of British Columbia, JP North 3rd Floor, Room 3114, 910 West 10th Avenue, Vancouver, BC, V5Z 4E3, Canada
| |
Collapse
|
13
|
Lu YD, Yen SH, Kuo FC, Wang JW, Wang CJ. No benefit on functional outcomes and dislocation rates by increasing head size to 36 mm in ceramic-on-ceramic total hip arthroplasty. Biomed J 2016; 38:538-43. [PMID: 27013454 PMCID: PMC6138375 DOI: 10.1016/j.bj.2016.01.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2014] [Accepted: 07/03/2015] [Indexed: 12/12/2022] Open
Abstract
Background Ceramic-on-ceramic (COC) total hip arthroplasty (THA) has gained popularity since improvements in wear characteristics and longevity. Whether large ceramic femoral heads (≥36 mm) have increased postoperative range of motion (ROM) and a lower dislocation rate is not clear. This study aimed to compare functional outcomes and early complications between large-head (≥36 mm) and smaller-head (≤32 mm) COC prostheses with a minimum follow-up of 12 months. Methods A total of 95 consecutive uncemented COC THAs were performed in 90 patients between January 2012 and July 2013. Of these, 49 patients (smaller-head group) received third generation and 41 patients (large-head group) received fourth generation COC prostheses. Harris hip score (HHS), Western Ontario and McMaster Universities Arthritis index (WOMAC), and ROM of the hip pre- and post-operatively were compared, as well as the presence of early complications. Results Postoperative HHSs (88.4 vs. 89.3, p = 0.34) and WOMAC scores (12.0 vs. 11.0, p = 0.111) were not different between the groups. Postoperative flexion ROM was lower in the smaller-head group (98.8° vs. 106.1°, p < 0.001), but there were no differences in extension, abduction, adduction, internal rotation, and external rotation. One patient in each group reported a grinding noise. There was one dislocation (1.9%) in the smaller-head group, and none in the large-head group (p = 0.371). No infections or loosening of the components occurred. Conclusions Large-head COC articulation provided better flexion, but functional outcomes and early complications are similar to the smaller-head COC.
Collapse
Affiliation(s)
- Yu-Der Lu
- Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| | - Shih-Hsiang Yen
- Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| | - Feng-Chih Kuo
- Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| | - Jun-Wen Wang
- Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan.
| | - Ching-Jen Wang
- Department of Orthopaedic Surgery, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan
| |
Collapse
|
14
|
Tsuda K, Haraguchi K, Koyanagi J, Takahashi S, Sugama R, Fujiwara K. A forty millimetre head significantly improves range of motion compared with a twenty eight millimetre head in total hip arthroplasty using a computed tomography-based navigation system. INTERNATIONAL ORTHOPAEDICS 2016; 40:2031-2039. [PMID: 26780716 DOI: 10.1007/s00264-015-3095-x] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2015] [Accepted: 12/23/2015] [Indexed: 02/06/2023]
Abstract
PURPOSE Larger-diameter (≥40 mm) femoral heads decrease the incidence of post-operative dislocation in total hip arthroplasty (THA). This study was conducted to discover whether larger-diameter femoral heads result in greater range of motion of the hip with the use of a computed tomography (CT)-based navigation system. METHODS Thirty-nine primary THAs were performed via a posterolateral approach using a CT-based navigation system. The stem was inserted in the femur in line with the original femoral neck anteversion. Considering the range of motion during various daily activities which could occur without impingement, the cup anteversion was decided at 10 ° increments according to the stem anteversion. While the cup inclination was set at 40 ° in order to avoid a high inclination angle to prevent the edge roading between the HXLPE liner and ceramic head. After implantation, trial liners and femoral heads were used with either 28 or 40 mm diameter. Maximal hip flexion, extension, abduction, external rotation in extension at 0° and internal rotation angles in flexion at 90 ° were measured. The differences between the ranges of motion with the 40-mm and 28-mm heads were tested. The results were assessed with paired Student t-tests. RESULTS The ranges of motion in flexion, extension, abduction and internal rotation angles improved significantly with the 40-mm heads compared with the 28-mm heads. The ranges of motion of cases where maximal flexion angle was 90° or less were excluded, improved significantly with the 40 mm heads. CONCLUSIONS We concluded that the larger-diameter 40-mm femoral prosthetic heads result in greater ranges of motion in flexion, extension, abduction and internal rotation.
Collapse
Affiliation(s)
- Kosuke Tsuda
- Arthroplasty Center, Osaka General Medical Center, 3-1-56, Bandai-higashi, Sumiyoshi, Osaka, Japan. .,Department of Orthopaedic Surgery, Osaka General Medical Center, 3-1-56, Bandai-higashi, Sumiyoshi, Osaka, Japan.
| | - Keiji Haraguchi
- Arthroplasty Center, Osaka General Medical Center, 3-1-56, Bandai-higashi, Sumiyoshi, Osaka, Japan.,Department of Orthopaedic Surgery, Osaka General Medical Center, 3-1-56, Bandai-higashi, Sumiyoshi, Osaka, Japan
| | - Junichiro Koyanagi
- Arthroplasty Center, Osaka General Medical Center, 3-1-56, Bandai-higashi, Sumiyoshi, Osaka, Japan.,Department of Orthopaedic Surgery, Osaka General Medical Center, 3-1-56, Bandai-higashi, Sumiyoshi, Osaka, Japan
| | - Shintaro Takahashi
- Department of Orthopaedic Surgery, Osaka Rosai Hospital, 1179-3, Nagasone-cho, Kita, Sakai, Osaka, Japan
| | - Ryo Sugama
- Department of Orthopaedic Surgery, Saiseikai Nakatsu Hospital, 2-10-39, Shibata, Kita, Osaka, Japan
| | - Keiju Fujiwara
- Department of Orthopaedic Surgery, Osaka General Medical Center, 3-1-56, Bandai-higashi, Sumiyoshi, Osaka, Japan
| |
Collapse
|
15
|
Jensen C, Penny JØ, Nielsen DB, Overgaard S, Holsgaard-Larsen A. Quantifying Gait Quality in Patients with Large-Head and Conventional Total Hip Arthroplasty--A Prospective Cohort Study. J Arthroplasty 2015; 30:2343-8.e1. [PMID: 26278486 DOI: 10.1016/j.arth.2015.06.049] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/18/2015] [Revised: 06/19/2015] [Accepted: 06/22/2015] [Indexed: 02/01/2023] Open
Abstract
We used the Gait Deviation Index (GDI) as method to compare preoperative to postoperative gait changes after uncemented 50 mm (median) large-head and 28/32 mm total hip arthroplasty (THA). We also identified predictors of improvements in GDI. Gait analysis and patient-reported (WOMAC) data were recorded in 35 patients before, 2 and 6-months after treatment. Twenty age-matched adults provided normative gait data. Contrary to our hypothesis, patients who received large-head THA had less improvement in GDI compared with patients who received 28/32 mm THA. The preoperative GDI score was identified as a predictor of postoperative GDI improvement, while WOMAC, age, gender and walking speed were not. This study provides useful information for clinicians and rehabilitation specialists about gait improvement that can be expected after THA.
Collapse
Affiliation(s)
- Carsten Jensen
- Department of Orthopedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Jeannette Ø Penny
- Department of Orthopedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Department of Orthopedic Surgery, Naestved Hospital, Naestved, Denmark
| | - Dennis B Nielsen
- Department of Orthopedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Søren Overgaard
- Department of Orthopedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Anders Holsgaard-Larsen
- Department of Orthopedic Surgery and Traumatology, Odense University Hospital, Odense, Denmark; Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
16
|
Parry MC, Povey J, Blom AW, Whitehouse MR. Comparison of Acetabular Bone Resection, Offset, Leg Length and Post Operative Function Between Hip Resurfacing Arthroplasty and Total Hip Arthroplasty. J Arthroplasty 2015; 30:1799-803. [PMID: 25981328 DOI: 10.1016/j.arth.2015.04.030] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2015] [Revised: 03/29/2015] [Accepted: 04/20/2015] [Indexed: 02/01/2023] Open
Abstract
Controversy exists regarding the amount of acetabular bone resection, biomechanics and function of patients receiving either total hip arthroplasty (THA) or hip resurfacing arthroplasty (HRA). A cohort of patients undergoing 36 mm ceramic-on-ceramic THA (89) or metal-on-metal HRA (86) were compared. No difference was observed when the ratio of native femoral head size was compared to the implanted acetabular component size (1.15 ± 0.1 HRA c.f. 1.13 ± 0.1 THA). No difference was observed in acetabular offset, vertical centre of rotation or function (OHS mean 47 in both groups) but leg length discrepancy (1.8 mm c.f. 5.5 mm) and femoral offset did differ (0.6 mm c.f. 4.1 mm). This demonstrates that 36 mm ceramic-on-ceramic THA is not associated with more bone resection than HRA and achieves equivalent function whilst avoiding the problems of metal-on-metal bearings.
Collapse
Affiliation(s)
- Michael C Parry
- Muculoskeletal Research Unit, University of Bristol, Level 1 Learning and Research Building, Southmead Hospital, Westbury-on-Trym, Bristol, UK
| | - James Povey
- Muculoskeletal Research Unit, University of Bristol, Level 1 Learning and Research Building, Southmead Hospital, Westbury-on-Trym, Bristol, UK
| | - Ashley W Blom
- Muculoskeletal Research Unit, University of Bristol, Level 1 Learning and Research Building, Southmead Hospital, Westbury-on-Trym, Bristol, UK
| | - Michael R Whitehouse
- Muculoskeletal Research Unit, University of Bristol, Level 1 Learning and Research Building, Southmead Hospital, Westbury-on-Trym, Bristol, UK
| |
Collapse
|
17
|
Grob K, Manestar M, Ackland T, Filgueira L, Kuster MS. Potential Risk to the Superior Gluteal Nerve During the Anterior Approach to the Hip Joint: An Anatomical Study. J Bone Joint Surg Am 2015; 97:1426-31. [PMID: 26333738 PMCID: PMC7535096 DOI: 10.2106/jbjs.o.00146] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
BACKGROUND The anterior approach to the hip joint is widely used in pediatric and adult orthopaedic surgery, including hip arthroplasty. Atrophy of the tensor fasciae latae muscle has been observed in some cases, despite the use of this internervous approach. We evaluated the nerve supply to the tensor fasciae latae and its potential risk for injury during the anterior approach to the hip joint. METHODS Cadaveric hemipelves (n = 19) from twelve human specimens were dissected. The course of the nerve branch to the tensor fasciae latae muscle, as it derives from the superior gluteal nerve, was studied in relation to the ascending branch of the lateral circumflex femoral artery where it enters the tensor fasciae latae. RESULTS The nerve supply to the tensor fasciae latae occurs in its proximal half by divisions of the inferior branch of the superior gluteal nerve. The nerve branches were regularly coursing in the deep surface on the medial border of the tensor fasciae latae muscle. In seventeen of nineteen cases, one or two nerve branches entered the tensor fasciae latae within 10 mm proximal to the entry point of the ascending branch of the lateral circumflex femoral artery. CONCLUSIONS Coagulation of the ascending branch of the lateral circumflex femoral artery and the placement of retractors during the anterior approach to the hip joint carry the potential risk for injury to the motor nerve branches supplying the tensor fasciae latae. CLINICAL RELEVANCE During the anterior approach, the ligation or coagulation of the ascending branch of the lateral circumflex femoral artery should not be performed too close to the point where it enters the tensor fasciae latae. The nerve branches to the tensor fasciae latae could also be compromised by the extensive use of retractors, broaching of the femur during hip arthroplasty, or the inappropriate proximal extension of the anterior approach.
Collapse
Affiliation(s)
- Karl Grob
- Department of Orthopaedic Surgery, Kantonsspital St. Gallen, Rorschacher Strasse 95, St. Gallen CH-9007, Switzerland. E-mail address:
| | - Mirjana Manestar
- Department of Anatomy, University of Zürich-Irchel, Winterhurerstrasse 190, Zürich CH-8507, Switzerland. E-mail address:
| | - Timothy Ackland
- The University of Western Australia, 35 Stirling Highway, Crawley WA 6009, Perth, Australia. E-mail address for T. Ackland: . E-mail address for M.S. Kuster:
| | - Luis Filgueira
- Department of Anatomy, University of Fribourg, Rue A, Gockel 1, Fribourg CH-1700, Switzerland. E-mail address:
| | - Markus S. Kuster
- The University of Western Australia, 35 Stirling Highway, Crawley WA 6009, Perth, Australia. E-mail address for T. Ackland: . E-mail address for M.S. Kuster:
| |
Collapse
|
18
|
Caplan N, Stewart S, Kashyap S, Banaszkiewicz P, St Clair Gibson A, Kader D, Ewen A. The effect of total hip and hip resurfacing arthroplasty on vertical ground reaction force and impulse symmetry during a sit-to-stand task. Clin Biomech (Bristol, Avon) 2014; 29:1164-9. [PMID: 25293891 DOI: 10.1016/j.clinbiomech.2014.09.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2014] [Revised: 09/18/2014] [Accepted: 09/18/2014] [Indexed: 02/07/2023]
Abstract
BACKGROUND The aim of this study was to determine the influence of total hip arthroplasty and hip resurfacing arthroplasty on limb loading symmetry before, and after, hip reconstruction surgery during a sit-to-stand task. METHODS Fourteen patients were recruited that were about to receive either a total hip prosthesis (n=7) or a hip resurfacing prosthesis (n=7), as well as matched controls. Patients performed a sit-to-stand movement before, 3 months after, and 12 months after surgery. Peak vertical ground reaction force and impulse were measured for each leg, from which ground reaction force and impulse symmetry ratios were calculated. FINDINGS Before surgery, hip resurfacing patients showed a small asymmetry which was not different to normal for ground reaction force (0.88(0.28) vs. 1.00(0.11); p=0.311) or impulse (0.87(0.29) vs. 0.99(0.09); p=0.324) symmetry ratios. Total hip patients offloaded their affected hip by 30% in terms of impulse symmetry ratio (0.71(0.36) vs. 0.99(0.23); p=0.018). At 3 months following surgery asymmetries were seen that were different to normal in both hip resurfacing patients for ground reaction force (0.77(0.16); p=0.007), and total hip patients for ground reaction force (0.70(0.15); p=0.018) and impulse (0.72(0.16); p=0.011) symmetry ratios. By 12 months after surgery total hip patients regained a symmetrical loading pattern for both ground reaction force (0.95(0.06); p=0.676) and impulse (1.00(0.06); p=0.702) symmetry ratios. Hip resurfacing patients, however, performed the task by overloading their operated hip, with impulse symmetry ratio being larger than normal (1.16(0.16); p=0.035). INTERPRETATION Physiotherapists should appreciate the need for early recovery of limb loading symmetry as well as subsequent differences in the responses observed with different prostheses.
Collapse
Affiliation(s)
- N Caplan
- Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK.
| | - S Stewart
- Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK
| | - S Kashyap
- Department of Trauma and Orthopaedics, Queen Elizabeth Hospital, Gateshead, UK
| | - P Banaszkiewicz
- Department of Trauma and Orthopaedics, Queen Elizabeth Hospital, Gateshead, UK
| | - A St Clair Gibson
- Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK
| | - D Kader
- Department of Trauma and Orthopaedics, Queen Elizabeth Hospital, Gateshead, UK
| | - A Ewen
- Faculty of Health and Life Sciences, Northumbria University, Newcastle upon Tyne, UK
| |
Collapse
|
19
|
Almousa SA, Greidanus NV, Masri BA, Duncan CP, Garbuz DS. The natural history of inflammatory pseudotumors in asymptomatic patients after metal-on-metal hip arthroplasty. Clin Orthop Relat Res 2013; 471:3814-21. [PMID: 23536176 PMCID: PMC3825901 DOI: 10.1007/s11999-013-2944-4] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Although pseudotumors have been reported in 32% of asymptomatic metal-on-metal hips, the natural history of asymptomatic pseudotumors is unknown. QUESTIONS/PURPOSES The purpose of this study was to assess changes over time in asymptomatic pseudotumors and the effect of revision on pseudotumor mass. METHODS Followup ultrasound was performed a mean of 25.8 months (range, 21-31 months) after the detection of 15 pseudotumors and five isolated fluid collections in a cohort of 20 asymptomatic patients (13 metal-on-metal, three metal-on-polyethylene, and four hip resurfacings) [42]. Changes in pseudotumors and fluid collections size and nature, and serum ion levels were determined. RESULTS Among the 15 nonrevised patients, pseudotumors increased in size in six (four solid and two cystic) of 10 patients, three of which had clinically important increases (13-148 cm(3); 28-74 cm(3); 47-104 cm(3)). Three pseudotumors (one solid and two cystic) disappeared completely (the largest measured 31 cm(3)). One solid pseudotumor decreased in size (24 to 18 cm(3)). In five revised patients, pseudotumors completely disappeared in four patients. The fifth patient had two masses that decreased from 437 cm(3) to 262 cm(3) and 43 cm(3) to 25 cm(3). All revision patients had a reduction of chromium (40.42 μ/L to 2.69 μ/L) and cobalt ions (54.19 μ/L to 0.64 μ/L). Of five isolated fluid collections, four completely disappeared (two metal-on-metal and two metal-on-polyethylene) and one (metal-on-metal) increased from 26 cm(3) to 136 cm(3). CONCLUSIONS Our observations suggest pseudotumors frequently increase in size in asymptomatic patients with occasional remission of small masses. Revision resulted in remission of pseudotumors.
Collapse
Affiliation(s)
- Sulaiman A. Almousa
- />Department of Orthopaedics, University of British Columbia, Room 3114, 910 West 10th Avenue, Vancouver, British Columbia V5Z 4E3 Canada , />Department of Orthopedics, University of Dammam, Dammam, Saudi Arabia
| | - Nelson V. Greidanus
- />Department of Orthopaedics, University of British Columbia, Room 3114, 910 West 10th Avenue, Vancouver, British Columbia V5Z 4E3 Canada
| | - Bassam A. Masri
- />Department of Orthopaedics, University of British Columbia, Room 3114, 910 West 10th Avenue, Vancouver, British Columbia V5Z 4E3 Canada
| | - Clive P. Duncan
- />Department of Orthopaedics, University of British Columbia, Room 3114, 910 West 10th Avenue, Vancouver, British Columbia V5Z 4E3 Canada
| | - Donald S. Garbuz
- />Department of Orthopaedics, University of British Columbia, Room 3114, 910 West 10th Avenue, Vancouver, British Columbia V5Z 4E3 Canada
| |
Collapse
|
20
|
Penny JØ, Ovesen O, Varmarken J, Overgaard S. Similar range of motion and function after resurfacing large-head or standard total hip arthroplasty. Acta Orthop 2013; 84:246-53. [PMID: 23530872 PMCID: PMC3715815 DOI: 10.3109/17453674.2013.788435] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Large-size hip articulations may improve range of motion (ROM) and function compared to a 28-mm THA, and the low risk of dislocation allows the patients more activity postoperatively. On the other hand, the greater extent of surgery for resurfacing hip arthroplasty (RHA) could impair rehabilitation. We investigated the effect of head size and surgical procedure on postoperative rehabilitation in a randomized clinical trial (RCT). Methods We followed randomized groups of RHAs, large-head THAs and standard THAs at 2 months, 6 months, 1 and 2 years postoperatively, recording clinical rehabilitation parameters. RESULTS Large articulations increased the mean total range of motion by 13° during the first 6 postoperative months. The increase was not statistically significant and was transient. The 2-year total ROM (SD) for RHA, standard THA, and large-head THA was 221° (35), 232° (36), and 225° (30) respectively, but the differences were not statistically significant. The 3 groups were similar regarding Harris hip score, UCLA activity score, step rate, and sick leave. INTERPRETATION Head size had no influence on range of motion. The lack of restriction allowed for large articulations did not improve the clinical and patient-perceived outcomes. The more extensive surgical procedure of RHA did not impair the rehabilitation. This project is registered at ClinicalTrials.gov under # NCT01113762.
Collapse
Affiliation(s)
- Jeannette Østergaard Penny
- Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense,Department of Orthopedic Surgery, Naestved Hospital, Naestved,Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
| | - Ole Ovesen
- Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense,Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
| | | | - Søren Overgaard
- Department of Orthopaedic Surgery and Traumatology, Odense University Hospital, Odense,Institute of Clinical Research, University of Southern Denmark, Odense, Denmark
| |
Collapse
|
21
|
Cai P, Hu Y, Xie J. Large-diameter Delta ceramic-on-ceramic versus common-sized ceramic-on-polyethylene bearings in THA. Orthopedics 2012; 35:e1307-13. [PMID: 22955394 DOI: 10.3928/01477447-20120822-14] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The higher failure rate of total hip arthroplasty (THA) in young, active patients remains a challenge for surgeons. Recently, larger-diameter femoral heads combined with an alumina matrix composite ceramic (BIOLOX Delta; CeramTec AG, Plochingen, Germany) articulation was developed to improve implant longevity and meet patients' activity demands while reducing the risk of component-related complications. The purpose of this study was to determine whether this new device may provide advantages for young, active patients. A prospective, randomized, controlled trial was conducted on 93 patients (113 THAs) with more than 3 years of follow-up. Patients were randomly divided into a study group (51 THAs) with a 36-mm Delta ceramic-on-ceramic (COC) articulation and a control group (62 THAs) with a common-sized alumina ceramic head on polyethylene liner (COP) articulation. Clinical and radiographic results were collected to compare the outcomes and complications, including implant-related failures, osteolysis, and noises. The large-diameter Delta COC articulation provided greater range of motion improvement (6.1° more), similar Harris Hip Scores, and similar complication rates compared with the alumina COP articulation. This study suggests that in the short term, the large-diameter Delta COC articulation results in better range of motion with no higher complication rates; however, mid-term (8-10 years) or longer follow-up is necessary to determine its superiority in young, active patients.
Collapse
Affiliation(s)
- Pengde Cai
- Department of Orthopaedics, Xiangya Hospital, Central South University, Changsha, Hunan, China
| | | | | |
Collapse
|
22
|
Kouyoumdjian P, Coulomb R, Sanchez T, Asencio G. Clinical evaluation of hip joint rotation range of motion in adults. Orthop Traumatol Surg Res 2012; 98:17-23. [PMID: 22227606 DOI: 10.1016/j.otsr.2011.08.015] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2011] [Revised: 07/15/2011] [Accepted: 08/17/2011] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Data on hip joint rotation range of motion (ROM) are rare; the methods of measurement vary and reproducibility has not been evaluated, in particular in relation to the subject's position (prone or supine, seated). HYPOTHESIS Hip joint rotation ROM is symmetrical, and ROM is not modified by the patient's position when data is obtained. PATIENTS AND METHODS This series included 120 adults between 20 and 60 years old (71 women, 49 men), who had no hip, spine or lower extremity disorders. External (ER) and internal (IR) rotation ROM was obtained using a photographic method by two observers. Measurements were obtained with the patient in three positions: the dorsal decubitus (supine) (P1), and ventral decubitus (prone) (P2) with the hip in extension and seated with the hip in flexion (P3). RESULTS Hip rotation ROM was P1: 68.1° (ER=38.5°; IR=29.6°); P2: 77.1°(ER=41.8°; IR=35.2°); P3: 78.5° (ER=78.5°; IR=37.9°) with no significant difference among the three positions. Interobserver reproducibility was satisfactory (concordance correlation coefficient (ccc) 0.7) and was comparable in the three positions with a ccc of 0.7072 (P1), 0.7426 (P2) and 0.7332 (P3), respectively. Hip rotation ROM balance was ER predominant in 47.5%, neutral in 39.5% and IR predominant in 13%. Hip rotation ROM balance was symmetric in both hips in 73 subjects (61%). Hip rotation ROM was reduced with age (P<0.0001), and was 4.7° less in men (P=0.0078), and in overweight subjects (P<0.0006). DISCUSSION Our values are probably lower than those in the literature because of the difference in study population. In our series, age, BMI and gender seemed to be determining factors. Hip rotation ROM balance is usually ER predominant or neutral. Hip rotation ROM can be measured in the three positions with no significant difference, with satisfactory interobserver reproducibility for each. TYPE OF STUDY Diagnostic prospective study: level III.
Collapse
Affiliation(s)
- P Kouyoumdjian
- Orthopaedic surgery and traumatology department, Carémeau Teaching Hospital Center, Nimes cedex 9, France.
| | | | | | | |
Collapse
|
23
|
Girard J, Krantz N, Bocquet D, Wavreille G, Migaud H. Femoral head to neck offset after hip resurfacing is critical for range of motion. Clin Biomech (Bristol, Avon) 2012; 27:165-9. [PMID: 21925779 DOI: 10.1016/j.clinbiomech.2011.08.013] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2011] [Revised: 08/25/2011] [Accepted: 08/25/2011] [Indexed: 02/07/2023]
Abstract
BACKGROUND Range of motion after hip arthroplasty may be limited by soft tissues around the hip, extra-articular contact and femoral stem-neck contact with the acetabular articular surface. Femoral head-neck diameter ratio is recognized as a major factor influencing hip range of motion. In hip resurfacing, range of motion is constrained by "cup component to femoral neck" contact. To avoid cup-to-bone contact or to increase the degree of flexion at which it occurs, anterior translation of the femoral component relative to the central femoral neck axis may improve anterior head-neck offset and hip flexion. We questioned whether low or high anterior femoral head to neck offset, cup inclination, stem anteversion, and component size influenced postoperative range of motion and hip flexion in patients who had undergone hip resurfacing. METHODS We prospectively followed 66 patients (68 hips) who underwent hip resurfacing at a mean age at operation of 46.4 years (range, 19-60 years). Mean follow-up was 37.5 months (range, 33-41 months). No patient was lost to follow-up. All patients were evaluated clinically and range of motion was precised. Radiological measurement evaluated the anterior femoral head-neck offset. FINDINGS Mean anterior neck-head offset was 7.5mm (range, 5-12 mm). We found significant linear regression correlation between anterior offset and flexion (R=0.66) and between anterior offset and global range of motion (R=0.51). One millimeter of anterior offset increased hip range of motion by 5° in flexion. No significant correlations were found between global range of motion or flexion arc of motion and component size, stem anteversion, cup inclination, gender ratio, preoperative arc of flexion or global range of motion. INTERPRETATION Restoring or improving deficient anterior femoral head-neck offset appears important for restoring postoperative range of motion and specifically hip flexion.
Collapse
Affiliation(s)
- J Girard
- University Lille Nord de France, F-59000 Lille, France.
| | | | | | | | | |
Collapse
|
24
|
Eichhorn S, Steinhauser E, Gradinger R, Burgkart R. New method for determining in vitro structure stiffness of ceramic acetabular liners under different impact conditions. Med Eng Phys 2011; 34:512-5. [PMID: 22197061 DOI: 10.1016/j.medengphy.2011.11.020] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2011] [Revised: 11/15/2011] [Accepted: 11/17/2011] [Indexed: 10/14/2022]
Abstract
Increasing both patient mobility and prosthesis life span requires improvements in the range of motion and wear behavior of the liner. With the use of new composite alumina-zirconia ceramic materials, the same stability of the liner can be achieved at lower wall thickness than it is possible with alumina-only materials. The aim of this study was developing a method for determining the in vitro structure stiffness of ceramic acetabular liners against impact stresses. The first trials were performed with a common alumina acetabular liner type (Ceramtec; Biolox forte; diameter 28 mm; thickness 7 mm) and a new type of alumina-zirconia (Ceramtec Biolox delta; same dimensions) liner. The clinically established alumina liner was reproducibly damaged using worst case Separation/subluxation equivalent to one-fourth or half of the head diameter, and an impact load of 15 J. The liners containing the new alumina-zirconia material were not damaged in any of the trials up to an impact load of 20 J and half head diameter offset.
Collapse
Affiliation(s)
- Stefan Eichhorn
- Department of Orthopaedic Surgery, Klinikum Rechts der Isar, Technical University Munich, Munich, Germany.
| | | | | | | |
Collapse
|
25
|
Center of Mass Compensation during Gait in Hip Arthroplasty Patients: Comparison between Large Diameter Head Total Hip Arthroplasty and Hip Resurfacing. Rehabil Res Pract 2011; 2011:586412. [PMID: 22110976 PMCID: PMC3196873 DOI: 10.1155/2011/586412] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2011] [Revised: 05/09/2011] [Accepted: 06/21/2011] [Indexed: 11/17/2022] Open
Abstract
Objective. To compare center of mass (COM) compensation in the frontal and sagittal plane during gait in patients with large diameter head total hip arthroplasty (LDH-THA) and hip resurfacing (HR). Design. Observational study. Setting. Outpatient biomechanical laboratory.
Participants. Two groups of 12 patients with LDH-THA and HR recruited from a larger randomized study and 11 healthy controls. Interventions. Not applicable. Main Outcome Measures. To compare the distance between the hip prosthetic joint center (HPJC) and the COM. The ratio (RHPJC-COM) and the variability (CVHPJC-COM) were compared between groups. Hip flexor, abductor, and adductor muscle strength was also correlated between groups while radiographic measurements were correlated with the outcome measures. Results. In the frontal plane, HR shows less variability than healthy controls at push-off and toe-off and RHPJC-COM is correlated with the muscle strength ratios (FRABD) at heel contact, maximal weight acceptance, and mid stance. In the sagittal plane, LDH-THA has a higher RHPJC-COM than healthy controls at push-off, and CVHPJC-COM is significantly correlated with FRFLEX. Conclusions. One year after surgery, both groups of patients, LDH-THA and HR, demonstrate minor compensations at some specific instant of the gait cycle, in both frontal and sagittal planes. However, their locomotion pattern is similar to the healthy controls.
Collapse
|
26
|
|
27
|
No clinical difference between large metal-on-metal total hip arthroplasty and 28-mm-head total hip arthroplasty? INTERNATIONAL ORTHOPAEDICS 2011; 35:1771-6. [PMID: 21373801 DOI: 10.1007/s00264-011-1233-7] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2010] [Accepted: 02/12/2011] [Indexed: 10/18/2022]
Abstract
PURPOSE We aimed to test the claim of greater range of motion (ROM) with large femoral head metal-on-metal total hip arthroplasty. METHODS We compared 28-mm metal-on-polyethylene (MP) total hip arthroplasty with large femoral head metal-on-metal (MM) total hip arthroplasty in a randomised clinical trial. ROM one year postoperatively was determined in 50 patients. Mean head sizes were 28 mm (MP) and 48 mm (MM). RESULTS After one year, the large head MM group showed greater improvement in internal rotation (14 degrees) than the 28 mm group (seven degrees).There were no significant differences in the absolute values of postoperative internal rotation, external rotation, flexion, extension, abduction and abduction. CONCLUSIONS Absolute postoperative range of motion did not differ between the two groups. The improvement in internal rotation was greater after large femoral head metal-on-metal total hip arthroplasty. It is however questionable whether this difference is clinically relevant.
Collapse
|