1
|
Herrin KR, Kwak ST, Rock CG, Chang YH. Gait quality in prosthesis users is reflected by force-based metrics when learning to walk on a new research-grade powered prosthesis. FRONTIERS IN REHABILITATION SCIENCES 2024; 5:1339856. [PMID: 38370855 PMCID: PMC10869520 DOI: 10.3389/fresc.2024.1339856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2023] [Accepted: 01/12/2024] [Indexed: 02/20/2024]
Abstract
Introduction Powered prosthetic feet require customized tuning to ensure comfort and long-term success for the user, but tuning in both clinical and research settings is subjective, time intensive, and the standard for tuning can vary depending on the patient's and the prosthetist's experience levels. Methods Therefore, we studied eight different metrics of gait quality associated with use of a research-grade powered prosthetic foot in seven individuals with transtibial amputation during treadmill walking. We compared clinically tuned and untuned conditions with the goal of identifying performance-based metrics capable of distinguishing between good (as determined by a clinician) from poor gait quality. Results Differences between the tuned and untuned conditions were reflected in ankle power, both the vertical and anterior-posterior impulse symmetry indices, limb-force alignment, and positive ankle work, with improvements seen in all metrics during use of the tuned prosthesis. Discussion Notably, all of these metrics relate to the timing of force generation during walking which is information not directly accessible to a prosthetist during a typical tuning process. This work indicates that relevant, real-time biomechanical data provided to the prosthetist through the future provision of wearable sensors may enhance and improve future clinical tuning procedures associated with powered prostheses as well as their long-term outcomes.
Collapse
Affiliation(s)
- Kinsey R. Herrin
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA, United States
- Institute for Robotics and Intelligent Machines, Georgia Institute of Technology, Atlanta, GA, United States
| | - Samuel T. Kwak
- School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, United States
| | - Chase G. Rock
- School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, United States
| | - Young-Hui Chang
- Institute for Robotics and Intelligent Machines, Georgia Institute of Technology, Atlanta, GA, United States
- School of Biological Sciences, Georgia Institute of Technology, Atlanta, GA, United States
| |
Collapse
|
2
|
Fylstra BL, Lee IC, Li M, Lewek MD, Huang H. Human-prosthesis cooperation: combining adaptive prosthesis control with visual feedback guided gait. J Neuroeng Rehabil 2022; 19:140. [PMID: 36517814 PMCID: PMC9753428 DOI: 10.1186/s12984-022-01118-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Accepted: 11/23/2022] [Indexed: 12/23/2022] Open
Abstract
BACKGROUND Personalizing prosthesis control is often structured as human-in-the-loop optimization. However, gait performance is influenced by both human control and intelligent prosthesis control. Hence, we need to consider both human and prosthesis control, and their cooperation, to achieve desired gait patterns. In this study, we developed a novel paradigm that engages human gait control via user-fed visual feedback (FB) of stance time to cooperate with automatic prosthesis control tuning. Three initial questions were studied: (1) does user control of gait timing (via visual FB) help the prosthesis tuning algorithm to converge faster? (2) in turn, does the prosthesis control influence the user's ability to reach and maintain the target stance time defined by the feedback? and (3) does the prosthesis control parameters tuned with extended stance time on prosthesis side allow the user to maintain this potentially beneficial behavior even after feedback is removed (short- and long-term retention)? METHODS A reinforcement learning algorithm was used to achieve prosthesis control to meet normative knee kinematics in walking. A visual FB system cued the user to control prosthesis-side stance time to facilitate the prosthesis tuning goal. Seven individuals without amputation (AB) and four individuals with transfemoral amputation (TFA) walked with a powered knee prosthesis on a treadmill. Participants completed prosthesis auto-tuning with three visual feedback conditions: no FB, self-selected stance time FB (SS FB), and increased stance time FB (Inc FB). The retention of FB effects was studied by comparing the gait performance across three different prosthesis controls, tuned with different visual FB. RESULTS (1) Human control of gait timing reduced the tuning duration in individuals without amputation, but not for individuals with TFA. (2) The change of prosthesis control did not influence users' ability to reach and maintain the visual FB goal. (3) All participants increased their prosthesis-side stance time with the feedback and maintain it right after feedback was removed. However, in the post-test, the prosthesis control parameters tuned with visual FB only supported a few participants with longer stance time and better stance time symmetry. CONCLUSIONS The study provides novel insights on human-prosthesis interaction when cooperating in walking, which may guide the future successful adoption of this paradigm in prosthesis control personalization or human-in-the-loop optimization to improve the prosthesis user's gait performance.
Collapse
Affiliation(s)
- Bretta L. Fylstra
- grid.40803.3f0000 0001 2173 6074Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695 USA ,grid.10698.360000000122483208Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 USA
| | - I-Chieh Lee
- grid.40803.3f0000 0001 2173 6074Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695 USA ,grid.10698.360000000122483208Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 USA
| | - Minhan Li
- grid.40803.3f0000 0001 2173 6074Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695 USA ,grid.10698.360000000122483208Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 USA
| | - Michael D. Lewek
- grid.10698.360000000122483208Division of Physical Therapy, UNC Chapel Hill, Chapel Hill, NC 27599 USA
| | - He Huang
- grid.40803.3f0000 0001 2173 6074Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, NC 27695 USA ,grid.10698.360000000122483208Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599 USA
| |
Collapse
|
3
|
Liu W, Zhong J, Wu R, Fylstra BL, Si J, Huang HH. Inferring Human-Robot Performance Objectives During Locomotion Using Inverse Reinforcement Learning and Inverse Optimal Control. IEEE Robot Autom Lett 2022. [DOI: 10.1109/lra.2022.3143579] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
4
|
Lee IC, Fylstra BL, Liu M, Lenzi T, Huang H. Is there a trade-off between economy and task goal variability in transfemoral amputee gait? J Neuroeng Rehabil 2022; 19:29. [PMID: 35300696 PMCID: PMC8932056 DOI: 10.1186/s12984-022-01004-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Accepted: 02/22/2022] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND Energy cost minimization has been widely accepted to regulate gait. Optimization principles have been frequently used to explain how individuals adapt their gait pattern. However, there have been rare attempts to account for the role of variability in this optimization process. Motor redundancy can enable individuals to perform tasks reliably while achieving energy optimization. However, we do not know how the non-goal-equivalent and goal-equivalent variability is regulated. In this study, we investigated how unilateral transfemoral amputees regulate step and stride variability based on the task to achieve energy economy. METHODS Nine individuals with unilateral transfemoral amputation walked on a treadmill at speeds of 0.6, 0.8, 1.0, 1.2 and 1.4 m/s using their prescribed passive prostheses. We calculated the step-to-step and stride-to-stride variability and applied goal equivalent manifold (GEM) based control to decompose goal-equivalent and non-goal-equivalent manifold. To quantify the energy economy, the energy recovery rate (R) was calculated based on potential energy and kinetic energy. Comparisons were made between GEM variabilities and commonly used standard deviation measurements. A linear regression model was used to investigate the trade-off between R and GEM variabilities. RESULTS Our analysis shows greater variability along the goal-equivalent manifold compared to the non-goal-equivalent manifold (p < 0.001). Moreover, our analysis shows lower energy recovery rate for amputee gait compared to nonamputee gait (at least 20% less at faster walking speed). We found a negative relationship between energy recovery rate and non-goal-equivalent variability. Compared to the standard deviation measurements, the variability decomposed using GEM reflected the preferred walking speed and the limitation of the passive prosthetic device. CONCLUSION Individuals with amputation cleverly leverage task redundancy, regulating step and stride variability to the GEM. This result suggests that task redundancy enables unilateral amputees to benefit from motor variability in terms of energy economy. The differences observed between prosthetic step and intact step support the development of prosthetic limbs capable of enhancing positive work during the double support phase and of powered prosthesis controllers that allow for variability along the task space while minimizing variability that interferes with the task goal. This study provides a different perspective on amputee gait analysis and challenges the field to think differently about the role of variability.
Collapse
Affiliation(s)
- I-Chieh Lee
- Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina at Chapel Hill, Raleigh, NC, 27606, USA.
| | - Bretta L Fylstra
- Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina at Chapel Hill, Raleigh, NC, 27606, USA
| | - Ming Liu
- Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina at Chapel Hill, Raleigh, NC, 27606, USA
| | - Tommaso Lenzi
- Department of Mechanical Engineering and Robotics Center, The University of Utah, Salt Lake City, UT, USA
| | - He Huang
- Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina at Chapel Hill, Raleigh, NC, 27606, USA
| |
Collapse
|
5
|
Knight AD, Bass SR, Elrod JM, Hassinger LM, Dearth CL, Gonzalez-Vargas J, Hendershot BD, Han Z. Toward Developing a Powered Ankle-Foot Prosthesis With Electromyographic Control to Enhance Functional Performance: A Case Study in a U.S. Service Member. Mil Med 2022; 188:usac038. [PMID: 35234252 DOI: 10.1093/milmed/usac038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 01/26/2022] [Accepted: 02/04/2022] [Indexed: 11/14/2022] Open
Abstract
The only commercially available ankle-foot prosthesis with powered propulsion lacks ruggedization and other capabilities for service members seeking to return to duty and/or other physically demanding activities. Here, we evaluated a ruggedized powered ankle-foot prosthesis with electromyographic control ("Warrior Ankle"; WA) in an experienced male user of the predicate (Empower) prosthesis. The participant (age = 56 years, mass = 86.8 kg, stature = 173 cm) completed a 650 m simulated hike with varying terrain at a fixed, self-selected speed in the WA and predicate prosthesis, with and without a 22.8 kg weighted vest ("loaded" and "unloaded," respectively). Peak dorsiflexion and plantarflexion angles were extracted from each gait cycle throughout the simulated hike (∼500 prosthetic-side steps). The participant walked faster with the WA (1.15 m/s) compared to predicate (0.80 m/s) prosthesis. On the prosthetic side, peak dorsiflexion angles were larger for the WA (loaded: 27.9°; unloaded: 26.9°) compared to the predicate (loaded: 19.4°; unloaded: 21.3°); peak plantarflexion angles were similar between prostheses and loading conditions [WA (loaded: 15.5°; unloaded: 14.9°), predicate (loaded: 16.9°; unloaded: 14.8°). The WA better accommodated the varying terrain profile, evidenced by greater peak dorsiflexion angles, as well as dorsiflexion and plantarflexion angles that more closely matched or exceeded those of the innate ankle [dorsiflexion (WA: 31.6°, predicate: 27.5°); plantarflexion (WA: 20.7°, predicate: 20.5°)]. Furthermore, the WA facilitated a faster walking speed, suggesting a greater functional capacity with the WA prosthesis. Although further design enhancements are needed, this case study demonstrated feasibility of a proof-of-concept, ruggedized powered ankle-foot prosthesis with electromyographic control.
Collapse
Affiliation(s)
- Ashley D Knight
- Research and Surveillance Division, DoD-VA Extremity Trauma and Amputation Center of Excellence, Bethesda, MD 20889, USA
- Department of Rehabilitation, Walter Reed National Military Medical Center, Bethesda, MD 20889, USA
- Department of Rehabilitation Medicine, Uniformed Services of the Health Sciences, Bethesda, MD 20814, USA
| | - Sarah R Bass
- Department of Rehabilitation, Walter Reed National Military Medical Center, Bethesda, MD 20889, USA
- Department of Rehabilitation Medicine, Uniformed Services of the Health Sciences, Bethesda, MD 20814, USA
| | - Jonathan M Elrod
- Department of Rehabilitation, Walter Reed National Military Medical Center, Bethesda, MD 20889, USA
- Henry M. Jackson Foundation for the Advancement of Military Medicine, Bethesda, MD 20817, USA
| | - Louise M Hassinger
- Department of Rehabilitation, Walter Reed National Military Medical Center, Bethesda, MD 20889, USA
| | - Christopher L Dearth
- Research and Surveillance Division, DoD-VA Extremity Trauma and Amputation Center of Excellence, Bethesda, MD 20889, USA
- Department of Rehabilitation, Walter Reed National Military Medical Center, Bethesda, MD 20889, USA
- Department of Surgery, Uniformed Services University of the Health Sciences-Walter Reed National Military Medical Center, Bethesda, MD 20814, USA
| | | | - Brad D Hendershot
- Research and Surveillance Division, DoD-VA Extremity Trauma and Amputation Center of Excellence, Bethesda, MD 20889, USA
- Department of Rehabilitation, Walter Reed National Military Medical Center, Bethesda, MD 20889, USA
- Department of Rehabilitation Medicine, Uniformed Services of the Health Sciences, Bethesda, MD 20814, USA
| | - Zhixiu Han
- Ottobock SE & Co. KGaA, Duderstadt 37115, Germany
| |
Collapse
|
6
|
Huang H(H, Si J, Brandt A, Li M. Taking Both Sides: Seeking Symbiosis Between Intelligent Prostheses and Human Motor Control during Locomotion. CURRENT OPINION IN BIOMEDICAL ENGINEERING 2021; 20:100314. [PMID: 34458654 PMCID: PMC8388605 DOI: 10.1016/j.cobme.2021.100314] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Robotic lower-limb prostheses aim to replicate the power-generating capability of biological joints during locomotion to empower individuals with lower-limb loss. However, recent clinical trials have not demonstrated clear advantages of these devices over traditional passive devices. We believe this is partly because the current designs of robotic prothesis controllers and clinical methods for fitting and training individuals to use them do not ensure good coordination between the prosthesis and user. Accordingly, we advocate for new holistic approaches in which human motor control and intelligent prosthesis control function as one system (defined as human-prosthesis symbiosis). We hope engineers and clinicians will work closely to achieve this symbiosis, thereby improving the functionality and acceptance of robotic prostheses and users' quality of life.
Collapse
Affiliation(s)
- He (Helen) Huang
- NC State/UNC Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina, USA, 27695
- NC State/UNC Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA, 27514
| | - Jennie Si
- Department of Electrical, Computer, and Energy Engineering, Arizona State University, Tempe, Arizona, USA, 85281
| | - Andrea Brandt
- NC State/UNC Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina, USA, 27695
- NC State/UNC Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA, 27514
| | - Minhan Li
- NC State/UNC Joint Department of Biomedical Engineering, North Carolina State University, Raleigh, North Carolina, USA, 27695
- NC State/UNC Joint Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA, 27514
| |
Collapse
|
7
|
Tiwari A, Joshi D. Design and Validation of a Real-Time Visual Feedback System to Improve Minimum Toe Clearance (mTC) in Transfemoral Amputees. IEEE Trans Neural Syst Rehabil Eng 2021; 29:1711-1722. [PMID: 34398756 DOI: 10.1109/tnsre.2021.3105139] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Tripping is accompanied by reduced minimum toe clearance (mTC) during the swing phase of gait. The risk of fall due to tripping among transfemoral amputees is nearly 67% which is greater than the transtibial amputees. Therefore, intervention to improve mTC can potentially enhance the quality of life among transfemoral amputees. In this paper, we first develop a real-time visual feedback system with center of pressure (CoP) information. Next, we recruited six non-disabled and three transfemoral amputees to investigate the effect on mTC while participants were trained to shift the CoP anteriorly/posteriorly during heel strike. Finally, to assess the lasting effect of training on mTC, retention trials were conducted without feedback. During feedback, posterior shift in the CoP improved the mTC significantly from 4.68 ± 0.40 cm to 6.12 ± 0.68 cm (p < 0.025) in non-disabled participants. A similar significant improvement in mTC from 4.60 ± 0.55 cm to 5.62 ± 0.57 cm was observed in amputees during posterior shift of CoP. Besides mTC, maximal toe clearances, i.e., maxTC1 and maxTC2, also showed a significant increase (p < 0.025) during the posterior shift of CoP in both the participants. Moreover, during retention, mTC did not differ significantly (p > 0.05) from feedback condition in amputee, suggesting a positive effect of feedback training. The foot-to-ground angle (FGA) at mTC increased significantly (p < 0.025) during posterior shift feedback in non-disabled suggests active ankle dorsiflexion in increasing mTC. However, in amputees, FGA at mTC did not differ significantly during both anterior and posterior CoP shift feedback. The present findings suggest CoP feedback as a potential strategy during gait rehabilitation of transfemoral amputees.
Collapse
|