1
|
Latifoltojar A, Duncan MKJ, Klusmann M, Sidhu H, Bainbridge A, Neriman D, Fraioli F, Lambert J, Ardeshna KM, Punwani S. Whole Body 3.0 T Magnetic Resonance Imaging in Lymphomas: Comparison of Different Sequence Combinations for Staging Hodgkin's and Diffuse Large B Cell Lymphomas. J Pers Med 2020; 10:E284. [PMID: 33339372 PMCID: PMC7765916 DOI: 10.3390/jpm10040284] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Revised: 12/09/2020] [Accepted: 12/11/2020] [Indexed: 11/16/2022] Open
Abstract
To investigate the diagnostic value of different whole-body magnetic resonance imaging (WB-MRI) protocols for staging Hodgkin and diffuse-large B-cell lymphomas (HL and DLBCL), twenty-two patients (M/F 12/10, median age 32, range 22-87, HL/DLBCL 14/8) underwent baseline WB-MRI and 18F-2-fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography (PET) fused with computed tomography (CT) scan 18F-FDG-PET-CT. The 3.0 T WB-MRI was performed using pre-contrast modified Dixon (mDixon), T2-weighted turbo-spin-echo (TSE), diffusion-weighted-imaging (DWI), dynamic-contrast-enhanced (DCE) liver/spleen, contrast-enhanced (CE) lung MRI and CE whole-body mDixon. WB-MRI scans were divided into: (1) "WB-MRI DWI+IP": whole-body DWI + in-phase mDixon (2) "WB-MRI T2-TSE": whole-body T2-TSE (3) "WB-MRI Post-C": whole-body CE mDixon + DCE liver/spleen and CE lung mDixon (4) "WB-MRI All ": the entire protocol. Two radiologists evaluated WB-MRIs at random, independently and then in consensus. Two nuclear-medicine-physicians reviewed 18F-FDG PET-CT in consensus. An enhanced-reference-standard (ERS) was derived using all available baseline and follow-up imaging. The sensitivity and specificity of WB-MRI protocols for nodal and extra-nodal staging was derived against the ERS. Agreement between the WB-MRI protocols and the ERS for overall staging was assessed using kappa statistic. For consensus WB-MRI, the sensitivity and specificity for nodal staging were 75%, 98% for WB-MRI DWI+IP, 76%, 98% for WB-MRI Post-C, 83%, 99% for WB-MRI T2-TSE and 87%, 100% for WB-MRI All. The sensitivity and specificity for extra-nodal staging were 67% 100% for WB-MRI DWI+IP, 89%, 100% for WB-MRI Post-C, 89%, 100% for WB-MRI T2-TSE and 100%, 100% for the WB-MRI All. The consensus WB-MRI All read had perfect agreement with the ERS for overall staging [kappa = 1.00 (95% CI: 1.00-1.00)]. The best diagnostic performance is achieved combining all available WB-MRI sequences.
Collapse
Affiliation(s)
- Arash Latifoltojar
- Centre for Medical Imaging, University College London, 2nd Floor Charles Bell House, 43-45 Foley Street, London W1W 7TS, UK; (A.L.); (H.S.)
- The Royal Marsden Hospital, Downs road, Sutton, Surrey SM2 5PT, UK
| | - Mark K. J. Duncan
- Department of Radiology, University College London Hospitals NHS Foundation Trust, 235 Euston Road, London NW1 2BU, UK; (M.K.J.D.); (M.K.)
| | - Maria Klusmann
- Department of Radiology, University College London Hospitals NHS Foundation Trust, 235 Euston Road, London NW1 2BU, UK; (M.K.J.D.); (M.K.)
| | - Harbir Sidhu
- Centre for Medical Imaging, University College London, 2nd Floor Charles Bell House, 43-45 Foley Street, London W1W 7TS, UK; (A.L.); (H.S.)
- Department of Radiology, University College London Hospitals NHS Foundation Trust, 235 Euston Road, London NW1 2BU, UK; (M.K.J.D.); (M.K.)
| | - Alan Bainbridge
- Department of Medical Physics and Biomedical Engineering, University College London Hospitals NHS Foundation Trust, 235 Euston Road, London NW1 2BU, UK;
| | - Deena Neriman
- Institute of Nuclear Medicine, University College London Hospitals NHS Foundation Trust, 235 Euston Road, London NW1 2BU, UK; (D.N.); (F.F.)
| | - Francesco Fraioli
- Institute of Nuclear Medicine, University College London Hospitals NHS Foundation Trust, 235 Euston Road, London NW1 2BU, UK; (D.N.); (F.F.)
| | - Jonathan Lambert
- Department of Haematology, University College London Hospitals NHS Foundation Trust, 235 Euston Road, London NW1 2BU, UK; (J.L.); (K.M.A.)
| | - Kirit M. Ardeshna
- Department of Haematology, University College London Hospitals NHS Foundation Trust, 235 Euston Road, London NW1 2BU, UK; (J.L.); (K.M.A.)
| | - Shonit Punwani
- Centre for Medical Imaging, University College London, 2nd Floor Charles Bell House, 43-45 Foley Street, London W1W 7TS, UK; (A.L.); (H.S.)
- Department of Radiology, University College London Hospitals NHS Foundation Trust, 235 Euston Road, London NW1 2BU, UK; (M.K.J.D.); (M.K.)
| |
Collapse
|