1
|
Wang R, Fu K, Zhao R, Wang D, Yang Z, Bin W, Gao Y, Ning X. Expanding the clinical application of OPM-MEG using an effective automatic suppression method for the dental brace metal artifact. Neuroimage 2024; 296:120661. [PMID: 38838840 DOI: 10.1016/j.neuroimage.2024.120661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2024] [Revised: 05/19/2024] [Accepted: 05/30/2024] [Indexed: 06/07/2024] Open
Abstract
Optically pumped magnetometer magnetoencephalography (OPM-MEG) holds significant promise for clinical functional brain imaging due to its superior spatiotemporal resolution. However, effectively suppressing metallic artifacts, particularly from devices such as orthodontic braces and vagal nerve stimulators remains a major challenge, hindering the wider clinical application of wearable OPM-MEG devices. A comprehensive analysis of metal artifact characteristics from time, frequency, and time-frequency perspectives was conducted for the first time using an OPM-MEG device in clinical medicine. This study focused on patients with metal orthodontics, examining the modulation of metal artifacts by breath and head movement, the incomplete regular sub-Gaussian distribution, and the high absolute power ratio in the 0.5-8 Hz band. The existing metal artifact suppression algorithms applied to SQUID-MEG, such as fast independent component analysis (FastICA), information maximization (Infomax), and algorithms for multiple unknown signal extraction (AMUSE), exhibit limited efficacy. Consequently, this study introduced the second-order blind identification (SOBI) algorithm, which utilized multiple time delays for the component separation of OPM-MEG measurement signals. We modified the time delays of the SOBI method to improve its efficacy in separating artifact components, particularly those in the ultralow frequency range. This approach employs the frequency-domain absolute power ratio, root mean square (RMS) value, and mutual information methods to automate the artifact component screening process. The effectiveness of this method was validated through simulation experiments involving four subjects in both resting and evoked experiments. In addition, the proposed method was also validated by the actual OPM-MEG evoked experiments of three subjects. Comparative analyses were conducted against the FastICA, Infomax, and AMUSE algorithms. Evaluation metrics included normalized mean square error, normalized delta band power error, RMS error, and signal-to-noise ratio, demonstrating that the proposed method provides optimal suppression of metal artifacts. This advancement holds promise for enhancing data quality and expanding the clinical applications of OPM-MEG.
Collapse
Affiliation(s)
- Ruonan Wang
- School of Instrumentation Science and Optoelectronic Engineering, Beihang University, Beijing 100191, China; Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Hangzhou 310051, China.
| | - Kaiwen Fu
- School of Instrumentation Science and Optoelectronic Engineering, Beihang University, Beijing 100191, China; Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Hangzhou 310051, China.
| | - Ruochen Zhao
- School of Instrumentation Science and Optoelectronic Engineering, Beihang University, Beijing 100191, China; Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Hangzhou 310051, China.
| | - Dawei Wang
- Department of Radiology, Qilu Hospital of Shandong University, Jinan 250012, China; National Innovation Platform for industry-Education Integration in Medicine-Engineering Interdisciplinary, Shandong Key Laboratory for Magnetic Field-free Medicine and Functional Imaging, Shandong University, Research Institute of Shandong University, Jinan, 250014, China.
| | - Zhimin Yang
- State Key Laboratory of Traditional Chinese Medicine Syndrome/Health Construction Center, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510120, China.
| | - Wei Bin
- State Key Laboratory of Traditional Chinese Medicine Syndrome/Health Construction Center, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, 510120, China.
| | - Yang Gao
- Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China; Institute of Large-scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University, Hangzhou 310051, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou 310051, China.
| | - Xiaolin Ning
- School of Instrumentation Science and Optoelectronic Engineering, Beihang University, Beijing 100191, China; Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing 100191, China; National Innovation Platform for industry-Education Integration in Medicine-Engineering Interdisciplinary, Shandong Key Laboratory for Magnetic Field-free Medicine and Functional Imaging, Shandong University, Research Institute of Shandong University, Jinan, 250014, China; National Institute of Extremely-Weak Magnetic Field Infrastructure, Hangzhou 310051, China.
| |
Collapse
|
2
|
Shirota Y, Akita M, Tajima S, Mochida T, Masaki K, Yumoto M. Origin coordinate influence on performance of temporally extended signal space separation in magnetoencephalography. Clin Neurophysiol 2024; 163:143-151. [PMID: 38744104 DOI: 10.1016/j.clinph.2024.04.020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 04/22/2024] [Accepted: 04/29/2024] [Indexed: 05/16/2024]
Abstract
OBJECTIVE Temporally extended signal space separation (tSSS) is a powerful method for artifact suppression in magnetoencephalography (MEG). Because tSSS first separates MEG signals coming from inside and outside a certain sphere, definition of the sphere origin is important. For this study, we explored the influence of origin choice on tSSS performance in spontaneous and evoked activity from epilepsy patients. METHODS Interictal epileptiform discharges (IEDs) and somatosensory evoked fields (SEFs) were processed with two tSSSs: one with the default origin of (0, 0, 40 mm) in the head coordinate, and the other with an individual origin estimated using each patient's anatomical magnetic resonance imaging (MRI). Equivalent current dipoles (ECDs) were calculated for the data. The ECD location and quality of estimation were compared across conditions. RESULTS MEG data from 21 patients revealed marginal differences in ECD location, but the estimation quality inferred from goodness of fit (GOF) and confidence volume (CV) was better for the tSSS with individual origins. This choice affected IEDs more than it affected SEFs. CONCLUSIONS Individual sphere model resulted in better GOF and CV. SIGNIFICANCE Application of tSSS using an individual origin would be more desirable when available. This parameter might influence spontaneous activity more strongly.
Collapse
Affiliation(s)
- Yuichiro Shirota
- Department of Clinical Laboratory, University of Tokyo Hospital, Tokyo, Japan.
| | - Megumi Akita
- Department of Clinical Laboratory, University of Tokyo Hospital, Tokyo, Japan
| | - Shotaro Tajima
- Department of Clinical Laboratory, University of Tokyo Hospital, Tokyo, Japan
| | - Tomoyuki Mochida
- Department of Clinical Laboratory, University of Tokyo Hospital, Tokyo, Japan
| | - Katsura Masaki
- Department of Clinical Laboratory, University of Tokyo Hospital, Tokyo, Japan
| | - Masato Yumoto
- Department of Clinical Laboratory, University of Tokyo Hospital, Tokyo, Japan
| |
Collapse
|
3
|
Li Y, Zhu H, Chen Q, Yang L, Chen F, Ma H, Xu H, Chen K, Bu J, Zhang R. Immediate Effects of Vagal Nerve Stimulation in Drug-Resistant Epilepsy Revealed by Magnetoencephalographic Recordings. Brain Connect 2023; 13:51-59. [PMID: 35974665 DOI: 10.1089/brain.2022.0011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Objective: Vagus nerve stimulation (VNS) has been a neuromodulatory option for treating drug-resistant epilepsy (DRE), but its mechanism remains unclear. To obtain insight into the mechanism by which VNS reduces epileptic seizures, the immediate effects of VNS in brain networks of DRE patients were investigated when the patients' vagal nerve stimulators were turned on. Methods: The brain network properties of 14 DRE patients with a vagal nerve stimulator and 14 healthy controls were evaluated using magnetoencephalography recordings for 6 main frequency bands. Results: Compared with healthy controls, DRE patients exhibited significant increases in functional connectivity in the theta, alpha, beta, and gamma bands and significant reductions in the small-world measure in the theta and beta bands. During periods when patients' vagal nerve stimulators were turned on, DRE patients showed significant reductions in functional connectivity in the theta and alpha bands and a significant increase in the small-world measure in the theta band when compared with periods when patients' vagal nerve stimulators were turned off. Conclusions: Our results indicate that the brain networks of DRE patients were pathologically hypersynchronous and instantaneous VNS can decrease the synchronization of brain networks of epileptic patients, which might play a key role in the mechanism by which VNS reduces epileptic seizures. In the theta band, instantaneous VNS can increase the network efficiency of DRE patients, and the increment in network efficiency may be helpful for improving brain cognitive function in epileptic patients. Impact statement For the first time, we investigated the immediate effects of vagus nerve stimulation (VNS) in the brain networks of drug-resistant epilepsy patients using magnetoencephalography. Our results show that instantaneous VNS can decrease the hypersynchronization of epileptic networks and increase the network efficiency of epileptic patients. Our results are helpful in understanding the mechanism of action by which VNS reduces epileptic seizures and improves the cognitive function in epileptic patients and the brain network reorganization caused by long-term VNS.
Collapse
Affiliation(s)
- Yuejun Li
- Department of Functional Neurosurgery and Affiliated Nanjing Brain Hospital, Nanjing Medical University, Nanjing, China.,Department of Magnetoencephalography, Affiliated Nanjing Brain Hospital, Nanjing Medical University, Nanjing, China
| | - Haitao Zhu
- Department of Functional Neurosurgery and Affiliated Nanjing Brain Hospital, Nanjing Medical University, Nanjing, China
| | - Qiqi Chen
- Department of Functional Neurosurgery and Affiliated Nanjing Brain Hospital, Nanjing Medical University, Nanjing, China.,Department of Magnetoencephalography, Affiliated Nanjing Brain Hospital, Nanjing Medical University, Nanjing, China
| | - Lu Yang
- Department of Functional Neurosurgery and Affiliated Nanjing Brain Hospital, Nanjing Medical University, Nanjing, China
| | - Fangqing Chen
- Department of Functional Neurosurgery and Affiliated Nanjing Brain Hospital, Nanjing Medical University, Nanjing, China
| | - Haiyan Ma
- Department of Functional Neurosurgery and Affiliated Nanjing Brain Hospital, Nanjing Medical University, Nanjing, China
| | - Honghao Xu
- Department of Functional Neurosurgery and Affiliated Nanjing Brain Hospital, Nanjing Medical University, Nanjing, China
| | - Kefan Chen
- Department of Functional Neurosurgery and Affiliated Nanjing Brain Hospital, Nanjing Medical University, Nanjing, China
| | - Jinxin Bu
- Department of Functional Neurosurgery and Affiliated Nanjing Brain Hospital, Nanjing Medical University, Nanjing, China
| | - Rui Zhang
- Department of Functional Neurosurgery and Affiliated Nanjing Brain Hospital, Nanjing Medical University, Nanjing, China
| |
Collapse
|
4
|
Jousmäki V. Gratifying Gizmos for Research and Clinical MEG. Front Neurol 2022; 12:814573. [PMID: 35153989 PMCID: PMC8830907 DOI: 10.3389/fneur.2021.814573] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2021] [Accepted: 12/24/2021] [Indexed: 11/13/2022] Open
Abstract
Experimental designs are of utmost importance in neuroimaging. Experimental repertoire needs to be designed with the understanding of physiology, clinical feasibility, and constraints posed by a particular neuroimaging method. Innovations in introducing natural, ecologically-relevant stimuli, with successful collaboration across disciplines, correct timing, and a bit of luck may cultivate novel experiments, new discoveries, and open pathways to new clinical practices. Here I introduce some gizmos that I have initiated in magnetoencephalography (MEG) and applied with my collaborators in my home laboratory and in several other laboratories. These gizmos have been applied to address neuronal correlates of audiotactile interactions, tactile sense, active and passive movements, speech processing, and intermittent photic stimulation (IPS) in humans. This review also includes additional notes on the ideas behind the gizmos, their evolution, and results obtained.
Collapse
Affiliation(s)
- Veikko Jousmäki
- Aalto NeuroImaging, Department of Neuroscience and Biomedical Engineering, Aalto University, Espoo, Finland
- Cognitive Neuroimaging Centre, Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore, Singapore
- *Correspondence: Veikko Jousmäki
| |
Collapse
|
5
|
de Lange P, Boto E, Holmes N, Hill RM, Bowtell R, Wens V, De Tiège X, Brookes MJ, Bourguignon M. Measuring the cortical tracking of speech with optically-pumped magnetometers. Neuroimage 2021; 233:117969. [PMID: 33744453 DOI: 10.1016/j.neuroimage.2021.117969] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 01/08/2021] [Accepted: 03/04/2021] [Indexed: 11/25/2022] Open
Abstract
During continuous speech listening, brain activity tracks speech rhythmicity at frequencies matching with the repetition rate of phrases (0.2-1.5 Hz), words (2-4 Hz) and syllables (4-8 Hz). Here, we evaluated the applicability of wearable MEG based on optically-pumped magnetometers (OPMs) to measure such cortical tracking of speech (CTS). Measuring CTS with OPMs is a priori challenging given the complications associated with OPM measurements at frequencies below 4 Hz, due to increased intrinsic interference and head movement artifacts. Still, this represents an important development as OPM-MEG provides lifespan compliance and substantially improved spatial resolution compared with classical MEG. In this study, four healthy right-handed adults listened to continuous speech for 9 min. The radial component of the magnetic field was recorded simultaneously with 45-46 OPMs evenly covering the scalp surface and fixed to an additively manufactured helmet which fitted all 4 participants. We estimated CTS with reconstruction accuracy and coherence, and determined the number of dominant principal components (PCs) to remove from the data (as a preprocessing step) for optimal estimation. We also identified the dominant source of CTS using a minimum norm estimate. CTS estimated with reconstruction accuracy and coherence was significant in all 4 participants at phrasal and word rates, and in 3 participants (reconstruction accuracy) or 2 (coherence) at syllabic rate. Overall, close-to-optimal CTS estimation was obtained when the 3 (reconstruction accuracy) or 10 (coherence) first PCs were removed from the data. Importantly, values of reconstruction accuracy (~0.4 for 0.2-1.5-Hz CTS and ~0.1 for 2-8-Hz CTS) were remarkably close to those previously reported in classical MEG studies. Finally, source reconstruction localized the main sources of CTS to bilateral auditory cortices. In conclusion, t his study demonstrates that OPMs can be used for the purpose of CTS assessment. This finding opens new research avenues to unravel the neural network involved in CTS across the lifespan and potential alterations in, e.g., language developmental disorders. Data also suggest that OPMs are generally suitable for recording neural activity at frequencies below 4 Hz provided PCA is used as a preprocessing step; 0.2-1.5-Hz being the lowest frequency range successfully investigated here.
Collapse
Affiliation(s)
- Paul de Lange
- Laboratoire de Cartographie fonctionnelle du Cerveau, UNI - ULB Neuroscience Institute, Université libre de Bruxelles (ULB), 808 Lennik Street, Brussels 1070, Belgium
| | - Elena Boto
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom
| | - Niall Holmes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom
| | - Ryan M Hill
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom
| | - Richard Bowtell
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom
| | - Vincent Wens
- Laboratoire de Cartographie fonctionnelle du Cerveau, UNI - ULB Neuroscience Institute, Université libre de Bruxelles (ULB), 808 Lennik Street, Brussels 1070, Belgium; Department of Functional Neuroimaging, Service of Nuclear Medicine, CUB Hôpital Erasme, Université libre de Bruxelles (ULB), Brussels, Belgium
| | - Xavier De Tiège
- Laboratoire de Cartographie fonctionnelle du Cerveau, UNI - ULB Neuroscience Institute, Université libre de Bruxelles (ULB), 808 Lennik Street, Brussels 1070, Belgium; Department of Functional Neuroimaging, Service of Nuclear Medicine, CUB Hôpital Erasme, Université libre de Bruxelles (ULB), Brussels, Belgium
| | - Matthew J Brookes
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, University Park, Nottingham NG7 2RD, United Kingdom
| | - Mathieu Bourguignon
- Laboratoire de Cartographie fonctionnelle du Cerveau, UNI - ULB Neuroscience Institute, Université libre de Bruxelles (ULB), 808 Lennik Street, Brussels 1070, Belgium; Laboratory of neurophysiology and movement biomechanics, UNI - ULB Neuroscience Institute, Université libre de Bruxelles (ULB), Brussels, Belgium; BCBL, Basque Center on Cognition, Brain and Language, San Sebastian 20009, Spain.
| |
Collapse
|
6
|
Sensorimotor Mapping With MEG: An Update on the Current State of Clinical Research and Practice With Considerations for Clinical Practice Guidelines. J Clin Neurophysiol 2021; 37:564-573. [PMID: 33165229 DOI: 10.1097/wnp.0000000000000481] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
In this article, we present the clinical indications and advances in the use of magnetoencephalography to map the primary sensorimotor (SM1) cortex in neurosurgical patients noninvasively. We emphasize the advantages of magnetoencephalography over sensorimotor mapping using functional magnetic resonance imaging. Recommendations to the referring physicians and the clinical magnetoencephalographers to achieve appropriate sensorimotor cortex mapping using magnetoencephalography are proposed. We finally provide some practical advice for the use of corticomuscular coherence, cortico-kinematic coherence, and mu rhythm suppression in this indication. Magnetoencephalography should now be considered as a method of reference for presurgical functional mapping of the sensorimotor cortex.
Collapse
|
7
|
Abstract
Noise sources in magnetoencephalography (MEG) include: (1) interference from outside the shielded room, (2) other people and devices inside the shielded room, (3) physiologic or nonphysiologic sources inside the patient, (4) activity from inside the head that is unrelated to the signal of interest, (5) intrinsic sensor and recording electronics noise, and (6) artifacts from other apparatus used during recording such as evoked response stimulators. There are other factors which corrupt MEG recording and interpretation and should also be considered "artifacts": (7) inadequate positioning of the patient, (8) changes in the head position during the recording, (9) incorrect co-registration, (10) spurious signals introduced during postprocessing, and (11) errors in fitting. The major means whereby magnetic interference can be reduced or eliminated are by recording inside a magnetically shielded room, using gradiometers that measure differential magnetic fields, real-time active compensation using reference sensors, and postprocessing with advanced spatio-temporal filters. Many of the artifacts that plague MEG are also seen in EEG, so an experienced electroencephalographer will have the advantage of being able to transfer his knowledge about artifacts to MEG. However, many of the procedures and software used during acquisition and analysis may themselves contribute artifact or distortion that must be recognized or prevented. In summary, MEG artifacts are not worse than EEG artifacts, but many are different, and-as with EEG-must be attended to.
Collapse
|
8
|
Lucena Gómez G, Peigneux P, Wens V, Bourguignon M. Localization accuracy of a common beamformer for the comparison of two conditions. Neuroimage 2021; 230:117793. [PMID: 33497769 DOI: 10.1016/j.neuroimage.2021.117793] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 11/03/2020] [Accepted: 01/15/2021] [Indexed: 11/25/2022] Open
Abstract
The linearly constrained minimum variance beamformer is frequently used to reconstruct sources underpinning neuromagnetic recordings. When reconstructions must be compared across conditions, it is considered good practice to use a single, "common" beamformer estimated from all the data at once. This is to ensure that differences between conditions are not ascribable to differences in beamformer weights. Here, we investigate the localization accuracy of such a common beamformer. Based on theoretical derivations, we first show that the common beamformer leads to localization errors in source reconstruction. We then turn to simulations in which we attempt to reconstruct a (genuine) source in a first condition, while considering a second condition in which there is an (interfering) source elsewhere in the brain. We estimate maps of mislocalization and assess statistically the difference between "standard" and "common" beamformers. We complement our findings with an application to experimental MEG data. The results show that the common beamformer may yield significant mislocalization. Specifically, the common beamformer may force the genuine source to be reconstructed closer to the interfering source than it really is. As the same applies to the reconstruction of the interfering source, both sources are pulled closer together than they are. This observation was further illustrated in experimental data. Thus, although the common beamformer allows for the comparison of conditions, in some circumstances it introduces localization inaccuracies. We recommend alternative approaches to the general problem of comparing conditions.
Collapse
Affiliation(s)
- Gustavo Lucena Gómez
- Laboratoire de Cartographie fonctionnelle du Cerveau, UNI - ULB Neuroscience Institute, Université libre de Bruxelles (ULB), Brussels, Belgium.
| | - Philippe Peigneux
- UR2NF - Neuropsychology and Functional Neuroimaging Research Unit at CRCN - Centre de Recherches Cognition et Neurosciences, and UNI - ULB Neuroscience Institute, Université libre de Bruxelles (ULB), Brussels, Belgium
| | - Vincent Wens
- Laboratoire de Cartographie fonctionnelle du Cerveau, UNI - ULB Neuroscience Institute, Université libre de Bruxelles (ULB), Brussels, Belgium; Magnetoencephalography unit, Department of Functional Neuroimaging, Service of Nuclear Medicine, CUB Hôpital Erasme, Brussels, Belgium
| | - Mathieu Bourguignon
- Laboratoire de Cartographie fonctionnelle du Cerveau, UNI - ULB Neuroscience Institute, Université libre de Bruxelles (ULB), Brussels, Belgium; BCBL, Basque Center on Cognition, Brain and Language, 20009 San Sebastian, Spain; Laboratoire Cognition Langage et Développement, UNI - ULB Neuroscience Institute, Université libre de Bruxelles (ULB), Brussels, Belgium
| |
Collapse
|
9
|
Abstract
This scientific commentary refers to ‘Magnetoencephalography for epileptic focus localization in a series of 1000 cases’, by Rampp et al. (doi:10.1093/brain/awz231).
Collapse
Affiliation(s)
- Richard C Burgess
- Director, Magnetoencephalography Laboratory, Cleveland Clinic Epilepsy Center, Cleveland, Ohio, USA
| |
Collapse
|
10
|
Murakami H, Wang ZI, Marashly A, Krishnan B, Prayson RA, Kakisaka Y, Mosher JC, Bulacio J, Gonzalez-Martinez JA, Bingaman WE, Najm IM, Burgess RC, Alexopoulos AV. Correlating magnetoencephalography to stereo-electroencephalography in patients undergoing epilepsy surgery. Brain 2018; 139:2935-2947. [PMID: 27567464 DOI: 10.1093/brain/aww215] [Citation(s) in RCA: 100] [Impact Index Per Article: 16.7] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2016] [Accepted: 07/06/2016] [Indexed: 11/15/2022] Open
Affiliation(s)
- Hiroatsu Murakami
- Department of Neurosurgery, Brain Research Institute, Niigata University, Niigata, Japan.,Epilepsy Center, Cleveland Clinic, Cleveland, OH, USA
| | - Zhong I Wang
- Epilepsy Center, Cleveland Clinic, Cleveland, OH, USA
| | - Ahmad Marashly
- Department of Child Neurology, Medical College of Wisconsin, Milwaukee, WI, USA
| | - Balu Krishnan
- Epilepsy Center, Cleveland Clinic, Cleveland, OH, USA
| | - Richard A Prayson
- Department of Anatomic Pathology, Cleveland Clinic, Cleveland, OH, USA
| | - Yosuke Kakisaka
- Department of Epileptology, Tohoku University School of Medicine, Sendai, Japan
| | - John C Mosher
- Epilepsy Center, Cleveland Clinic, Cleveland, OH, USA
| | - Juan Bulacio
- Epilepsy Center, Cleveland Clinic, Cleveland, OH, USA
| | | | | | - Imad M Najm
- Epilepsy Center, Cleveland Clinic, Cleveland, OH, USA
| | | | | |
Collapse
|
11
|
Hari R, Baillet S, Barnes G, Burgess R, Forss N, Gross J, Hämäläinen M, Jensen O, Kakigi R, Mauguière F, Nakasato N, Puce A, Romani GL, Schnitzler A, Taulu S. IFCN-endorsed practical guidelines for clinical magnetoencephalography (MEG). Clin Neurophysiol 2018; 129:1720-1747. [PMID: 29724661 PMCID: PMC6045462 DOI: 10.1016/j.clinph.2018.03.042] [Citation(s) in RCA: 89] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2017] [Revised: 03/18/2018] [Accepted: 03/24/2018] [Indexed: 12/22/2022]
Abstract
Magnetoencephalography (MEG) records weak magnetic fields outside the human head and thereby provides millisecond-accurate information about neuronal currents supporting human brain function. MEG and electroencephalography (EEG) are closely related complementary methods and should be interpreted together whenever possible. This manuscript covers the basic physical and physiological principles of MEG and discusses the main aspects of state-of-the-art MEG data analysis. We provide guidelines for best practices of patient preparation, stimulus presentation, MEG data collection and analysis, as well as for MEG interpretation in routine clinical examinations. In 2017, about 200 whole-scalp MEG devices were in operation worldwide, many of them located in clinical environments. Yet, the established clinical indications for MEG examinations remain few, mainly restricted to the diagnostics of epilepsy and to preoperative functional evaluation of neurosurgical patients. We are confident that the extensive ongoing basic MEG research indicates potential for the evaluation of neurological and psychiatric syndromes, developmental disorders, and the integrity of cortical brain networks after stroke. Basic and clinical research is, thus, paving way for new clinical applications to be identified by an increasing number of practitioners of MEG.
Collapse
Affiliation(s)
- Riitta Hari
- Department of Art, Aalto University, Helsinki, Finland.
| | - Sylvain Baillet
- McConnell Brain Imaging Centre, Montreal Neurological Institute, McGill University, Montreal, QC, Canada
| | - Gareth Barnes
- Wellcome Centre for Human Neuroimaging, University College of London, London, UK
| | - Richard Burgess
- Epilepsy Center, Neurological Institute, Cleveland Clinic, Cleveland, OH, USA
| | - Nina Forss
- Clinical Neuroscience, Neurology, University of Helsinki and Helsinki University Hospital, Helsinki, Finland
| | - Joachim Gross
- Centre for Cognitive Neuroimaging, University of Glasgow, Glasgow, UK; Institute for Biomagnetism and Biosignalanalysis, University of Muenster, Germany
| | - Matti Hämäläinen
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA; Harvard Medical School, Boston, MA, USA; NatMEG, Department of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden
| | - Ole Jensen
- Centre for Human Brain Health, University of Birmingham, Birmingham, UK
| | - Ryusuke Kakigi
- Department of Integrative Physiology, National Institute of Physiological Sciences, Okazaki, Japan
| | - François Mauguière
- Department of Functional Neurology and Epileptology, Neurological Hospital & University of Lyon, Lyon, France
| | | | - Aina Puce
- Department of Psychological and Brain Sciences, Indiana University, Bloomington, IN, USA
| | - Gian-Luca Romani
- Department of Neuroscience, Imaging and Clinical Sciences, Università degli Studi G. D'Annunzio, Chieti, Italy
| | - Alfons Schnitzler
- Institute of Clinical Neuroscience and Medical Psychology, and Department of Neurology, Heinrich-Heine-University, Düsseldorf, Germany
| | - Samu Taulu
- Institute for Learning & Brain Sciences, University of Washington, Seattle, WA, USA; Department of Physics, University of Washington, Seattle, WA, USA
| |
Collapse
|
12
|
Magnetoencephalography and ictal SPECT in patients with failed epilepsy surgery. Clin Neurophysiol 2018; 129:1651-1657. [DOI: 10.1016/j.clinph.2018.05.010] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2017] [Revised: 04/30/2018] [Accepted: 05/03/2018] [Indexed: 11/17/2022]
|
13
|
MEG May Reveal Hidden Population of Spikes in Epilepsy With Porencephalic Cyst/Encephalomalacia. J Clin Neurophysiol 2017; 34:546-549. [DOI: 10.1097/wnp.0000000000000362] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
14
|
Magnetoencephalographic Recordings in Infants Using a Standard-Sized Array. J Clin Neurophysiol 2017; 34:461-468. [DOI: 10.1097/wnp.0000000000000400] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023] Open
|
15
|
Resting state cortical oscillations of patients with Parkinson disease and with and without subthalamic deep brain stimulation: a magnetoencephalography study. J Clin Neurophysiol 2016; 32:109-18. [PMID: 25233246 DOI: 10.1097/wnp.0000000000000137] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
PURPOSE In this study, we investigate the modification to cortical oscillations of patients with Parkinson disease (PD) by subthalamic deep brain stimulation (STN-DBS). METHODS Spontaneous cortical oscillations of patients with PD were recorded with magnetoencephalography during on and off subthalamic nucleus deep brain stimulation states. Several features such as average frequency, average power, and relative subband power in regions of interest were extracted in the frequency domain, and these features were correlated with Unified Parkinson Disease Rating Scale III evaluation. The same features were also investigated in patients with PD without surgery and healthy controls. RESULTS Patients with Parkinson disease without surgery compared with healthy controls had a significantly lower average frequency and an increased average power in 1 to 48 Hz range in whole cortex. Higher relative power in theta and simultaneous decrease in beta and gamma over temporal and occipital were also observed in patients with PD. The Unified Parkinson Disease Rating Scale III rigidity score correlated with the average frequency and with the relative power of beta and gamma in frontal areas. During subthalamic nucleus deep brain stimulation, the average frequency increased significantly when stimulation was on compared with off state. In addition, the relative power dropped in delta, whereas it rose in beta over the whole cortex. Through the course of stimulation, the Unified Parkinson Disease Rating Scale III rigidity and tremor scores correlated with the relative power of alpha over left parietal. CONCLUSIONS Subthalamic nucleus deep brain stimulation improves the symptoms of PD by suppressing the synchronization of alpha rhythm in somatomotor region.
Collapse
|
16
|
Reliable recording and analysis of MEG-based corticokinematic coherence in the presence of strong magnetic artifacts. Clin Neurophysiol 2016; 127:1460-1469. [DOI: 10.1016/j.clinph.2015.07.030] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2015] [Revised: 07/08/2015] [Accepted: 07/25/2015] [Indexed: 11/21/2022]
|
17
|
Implanted medical devices or other strong sources of interference are not barriers to magnetoencephalographic recordings in epilepsy patients. Clin Neurophysiol 2013; 124:1283-9. [DOI: 10.1016/j.clinph.2013.04.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2012] [Revised: 03/20/2013] [Accepted: 04/04/2013] [Indexed: 11/21/2022]
|
18
|
Wang ZI, Alexopoulos AV, Nair D, Krishnan B, Mosher JC, Burgess RC, Kakisaka Y. Feasibility of magnetoencephalography recording in an epilepsy patient with implanted responsive cortical stimulation device. Clin Neurophysiol 2013; 124:1705-6. [PMID: 23474057 DOI: 10.1016/j.clinph.2013.01.019] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2012] [Revised: 01/24/2013] [Accepted: 01/31/2013] [Indexed: 11/15/2022]
|