1
|
Tanaka Y, Sasaki T, Kawabata S, Hashimoto J, Higashikawa H, Hoshino Y, Sekihara K, Adachi Y, Fujita K, Nimura A, Watanabe T, Miyano Y, Kaminaka S, Yamamoto Y, Yoshii T. Assessing ulnar neuropathy at the elbow using magnetoneurography. Clin Neurophysiol 2024; 161:180-187. [PMID: 38520798 DOI: 10.1016/j.clinph.2024.02.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 02/09/2024] [Accepted: 02/23/2024] [Indexed: 03/25/2024]
Abstract
OBJECTIVE To measure neuromagnetic fields of ulnar neuropathy patients at the elbow after electrical stimulation and evaluate ulnar nerve function at the elbow with high spatial resolution. METHODS A superconducting quantum interference device magnetometer system recorded neuromagnetic fields of the ulnar nerve at the elbow after electrical stimulation at the wrist in 16 limbs of 16 healthy volunteers and 21 limbs of 20 patients with ulnar neuropathy at the elbow. After artifact removal, neuromagnetic field signals were processed into current distributions, which were superimposed onto X-ray images for visualization. RESULTS Based on the results in healthy volunteers, conduction velocity of 30 m/s or 50% attenuation in current amplitude was set as the reference value for conduction disturbance. Of the 21 patient limbs, 15 were measurable and lesion sites were detected, whereas 6 limbs were unmeasurable due to weak neuromagnetic field signals. Seven limbs were deemed normal by nerve conduction study, but 5 showed conduction disturbances on magnetoneurography. CONCLUSIONS Measuring the magnetic field after nerve stimulation enabled visualization of neurophysiological activity in patients with ulnar neuropathy at the elbow and evaluation of conduction disturbances. SIGNIFICANCE Magnetoneurography may be useful for assessing lesion sites in patients with ulnar neuropathy at the elbow.
Collapse
Affiliation(s)
- Yuta Tanaka
- Department of Orthopedic Surgery, Graduate school of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
| | - Toru Sasaki
- Department of Orthopedic Surgery, Graduate school of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
| | - Shigenori Kawabata
- Department of Orthopedic Surgery, Graduate school of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan; Department of Advanced Technology in Medicine, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
| | - Jun Hashimoto
- Department of Orthopedic Surgery, Graduate school of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan; Department of Advanced Technology in Medicine, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
| | - Hisato Higashikawa
- Department of Orthopedic Surgery, Graduate school of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
| | - Yuko Hoshino
- Department of Advanced Technology in Medicine, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
| | - Kensuke Sekihara
- Department of Advanced Technology in Medicine, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
| | - Yoshiaki Adachi
- Applied Electronics Laboratory, Kanazawa Institute of Technology, 7-1 Ogigaoka, Nonoichi, Kanazawa-shi, Ishikawa 920-1331, Japan
| | - Koji Fujita
- Department of Functional Joint Anatomy, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
| | - Akimoto Nimura
- Department of Functional Joint Anatomy, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
| | - Taishi Watanabe
- Ricoh Institute of Future Technology, RICOH Company, Ltd., 2-3-10 Kandasurugadai, Chiyoda-ku, Tokyo 101-0062, Japan.
| | - Yuki Miyano
- Ricoh Institute of Future Technology, RICOH Company, Ltd., 2-3-10 Kandasurugadai, Chiyoda-ku, Tokyo 101-0062, Japan.
| | - Saeri Kaminaka
- Ricoh Institute of Future Technology, RICOH Company, Ltd., 2-3-10 Kandasurugadai, Chiyoda-ku, Tokyo 101-0062, Japan.
| | - Yusuke Yamamoto
- Ricoh Institute of Future Technology, RICOH Company, Ltd., 2-3-10 Kandasurugadai, Chiyoda-ku, Tokyo 101-0062, Japan.
| | - Toshitaka Yoshii
- Department of Orthopedic Surgery, Graduate school of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan.
| |
Collapse
|
2
|
Adachi Y, Kawabata S. SQUID magnetoneurography: an old-fashioned yet new tool for noninvasive functional imaging of spinal cords and peripheral nerves. FRONTIERS IN MEDICAL TECHNOLOGY 2024; 6:1351905. [PMID: 38690583 PMCID: PMC11058660 DOI: 10.3389/fmedt.2024.1351905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Accepted: 04/01/2024] [Indexed: 05/02/2024] Open
Abstract
We are engaged in the development and clinical application of a neural magnetic field measurement system that utilizes biomagnetic measurements to observe the activity of the spinal cord and peripheral nerves. Unlike conventional surface potential measurements, biomagnetic measurements are not affected by the conductivity distribution within the body, making them less influenced by the anatomical structure of body tissues. Consequently, functional testing using biomagnetic measurements can achieve higher spatial resolution compared to surface potential measurements. The neural magnetic field measurement, referred to as magnetoneurography, takes advantage of these benefits to enable functional testing of the spinal cord and peripheral nerves, while maintaining high spatial resolution and noninvasiveness. Our magnetoneurograph system is based on superconducting quantum interference devices (SQUIDs) similar to the conventional biomagnetic measurement systems. Various design considerations have been incorporated into the SQUID sensor array structure and signal processing software to make it suitable for detecting neural signal propagation along spinal cord and peripheral nerve. The technical validation of this system began in 1999 with a 3-channel SQUID system. Over the course of more than 20 years, we have continued technological development through medical-engineering collaboration, and in the latest prototype released in 2020, neural function imaging of the spinal cord and peripheral nerves, which could also be applied for the diagnosis of neurological disorders, has become possible. This paper provides an overview of the technical aspects of the magnetoneurograph system, covering the measurement hardware and software perspectives for providing diagnostic information, and its applications. Additionally, we discuss the integration with a helium recondensing system, which is a key factor in reducing running costs and achieving practicality in hospitals.
Collapse
Affiliation(s)
- Yoshiaki Adachi
- Applied Electronics Laboratory, Kanazawa Institute of Technology, Kanazawa, Japan
| | - Shigenori Kawabata
- Department of Advanced Technology in Medicine, Tokyo Medical and Dental University, Tokyo, Japan
- Section of Orthopaedic and Spine Surgery, Graduate School of Tokyo Medical and Dental University, Tokyo, Japan
| |
Collapse
|
3
|
Zhang Z, He A, Xu Z, Yang K, Kong X. Neuromuscular Magnetic Field Measurement Based on Superconducting Bio-Sensors. MICROMACHINES 2023; 14:1768. [PMID: 37763931 PMCID: PMC10535156 DOI: 10.3390/mi14091768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 09/08/2023] [Accepted: 09/12/2023] [Indexed: 09/29/2023]
Abstract
These years, disease-causing and disabling diseases have caused great concern. Neurological musculoskeletal disorders are diverse and affect people of a wide range of ages. And the lack of comprehensive diagnostic methods places a huge burden on healthcare systems and social economies. In this paper, the current status of clinical research on neuromuscular diseases is introduced, and the advantages of magnetic field measurement compared with clinical diagnostic methods are illustrated. A comprehensive description of the related technology of superconducting quantum interference devices (SQUIDs), magnetic field detection noise suppression scheme, the development trend of the sensor detection system, and the application and model establishment of the neuromuscular magnetic field is also given in this paper. The current research and development trends worldwide are compared simultaneously, and finally the conclusions and outlook are put forward. Based on the description of the existing literature and the ideas of other researchers, the next development trends and my own research ideas are presented in this paper, that is, starting from the establishment of a neuromuscular model, combining medical and industrial work, designing a sensor system that meets clinical needs, and laying the foundation for the clinical application of a bio-magnetic system. This review promotes a combination between medicine and industry, and guides researchers on considering the challenges of sensor development in terms of clinical needs. In addition, in this paper, the development trends are described, including the establishment of the model, the clinical demand for sensors, and the challenges of system development so as to give certain guidance to researchers.
Collapse
Affiliation(s)
- Zhidan Zhang
- The Institute for Future Wireless Research (iFWR), Ningbo University, Ningbo 315211, China; (Z.Z.); (A.H.); (K.Y.)
- The Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo 315211, China
| | - Anran He
- The Institute for Future Wireless Research (iFWR), Ningbo University, Ningbo 315211, China; (Z.Z.); (A.H.); (K.Y.)
- The Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo 315211, China
| | - Zihan Xu
- The Institute for Future Wireless Research (iFWR), Ningbo University, Ningbo 315211, China; (Z.Z.); (A.H.); (K.Y.)
- The Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo 315211, China
| | - Kun Yang
- The Institute for Future Wireless Research (iFWR), Ningbo University, Ningbo 315211, China; (Z.Z.); (A.H.); (K.Y.)
- The Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo 315211, China
| | - Xiangyan Kong
- The Institute for Future Wireless Research (iFWR), Ningbo University, Ningbo 315211, China; (Z.Z.); (A.H.); (K.Y.)
- The Faculty of Electrical Engineering and Computer Science, Ningbo University, Ningbo 315211, China
| |
Collapse
|
4
|
Nakayama K, Kohara N, Paku M, Sato S, Nakamura M, Ando M, Taniguchi S, Ishihara M, Tani Y, Itakura T, Saito T, Yakushiji Y. Visualization of axonal and volume currents in median nerve compound action potential using magnetoneurography. Clin Neurophysiol 2023; 152:57-67. [PMID: 37307628 DOI: 10.1016/j.clinph.2023.05.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Revised: 04/26/2023] [Accepted: 05/05/2023] [Indexed: 06/14/2023]
Abstract
OBJECTIVE Reconstruct compound median nerve action currents using magnetoneurography to clarify the physiological characteristics of axonal and volume currents and their relationship to potentials. METHODS The median nerves of both upper arms of five healthy individuals were investigated. The propagating magnetic field of the action potential was recorded using magnetoneurography, reconstructed into a current, and analyzed. The currents were compared with the potentials recorded from multipolar surface electrodes. RESULTS Reconstructed currents could be clearly visualized. Axonal currents flowed forward or backward in the axon, arcing away from the depolarization zone, turning about the subcutaneous volume conductor, and returning to the depolarization zone. The zero-crossing latency of the axonal current was approximately the same as the peak of its volume current and the negative peak of the surface electrode potential. Volume current waveforms were proportional to the derivative of axonal ones. CONCLUSIONS Magnetoneurography allows the visualization and quantitative evaluation of action currents. The currents in axons and in volume conductors could be clearly discriminated with good quality. Their properties were consistent with previous neurophysiological findings. SIGNIFICANCE Magnetoneurography could be a novel tool for elucidating nerve physiology and pathophysiology.
Collapse
Affiliation(s)
- Kentaro Nakayama
- Department of Neurology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Nobuo Kohara
- Department of Orthopedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan; Department of Neurology, Kobe City Medical Center General Hospital, 2-1-1 Minatojima Minamimachi, Chuo-ku, Kobe 650-0047, Japan.
| | - Masaaki Paku
- Department of Orthopedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Shinji Sato
- RICOH Futures BU, RICOH Company, Ltd., 2-3-10 Kandasurugadai Chiyoda-ku, Tokyo 101-0062, Japan
| | - Masataka Nakamura
- Department of Neurology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Muneharu Ando
- Department of Orthopedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Shinichirou Taniguchi
- Department of Orthopedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Masayuki Ishihara
- Department of Orthopedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Yoichi Tani
- Department of Orthopedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Takeshi Itakura
- Department of Orthopedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Takanori Saito
- Department of Orthopedic Surgery, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| | - Yusuke Yakushiji
- Department of Neurology, Kansai Medical University, 2-5-1 Shinmachi, Hirakata, Osaka 573-1010, Japan
| |
Collapse
|
5
|
Paku M, Ando M, Itakura T, Sato S, Tani Y, Ishihara M, Adachi T, Taniguchi S, Kohara N, Saito T. Magnetoneurography to investigate the mechanisms underlying the P9 far-field potential. Clin Neurophysiol 2023; 150:197-204. [PMID: 37099870 DOI: 10.1016/j.clinph.2023.03.358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 03/07/2023] [Accepted: 03/26/2023] [Indexed: 04/28/2023]
Abstract
OBJECTIVE The mechanism underlying the generation of P9 far-field somatosensory evoked potentials (SEPs) is unresolved. Accordingly, we used magnetoneurography to visualize the current distribution in the body at the P9 peak latency and elucidate the origin of P9 generation. METHODS We studied five healthy male volunteers without neurological abnormalities. We recorded far-field SEPs after median nerve stimulation at the wrist to identify the P9 peak latency. Using magnetoneurography, we recorded the evoked magnetic fields in the whole body under the same stimulus conditions as the SEP recording. We analyzed the reconstructed current distribution at the P9 peak latency. RESULTS At the P9 peak latency, we observed the reconstructed current distribution dividing the thorax into two parts, upper and lower. Anatomically, the depolarization site at the P9 peak latency was distal to the interclavicular space and at the level of the second intercostal space. CONCLUSIONS By visualizing the current distribution, we proved that P9 peak latency originates in the change in volume conductor size between the upper and lower thorax. SIGNIFICANCE We clarified that magnetoneurography analysis is affected by the current distribution due to the junction potential.
Collapse
Affiliation(s)
- Masaaki Paku
- Department of Orthopedic Surgery, Graduate School of Medicine, Kansai Medical University, 2-5-1 Shin-machi, Hirakata, Osaka 573-1010, Japan.
| | - Muneharu Ando
- Department of Orthopedic Surgery, Graduate School of Medicine, Kansai Medical University, 2-5-1 Shin-machi, Hirakata, Osaka 573-1010, Japan
| | - Takeshi Itakura
- Department of Orthopedic Surgery, Graduate School of Medicine, Kansai Medical University, 2-5-1 Shin-machi, Hirakata, Osaka 573-1010, Japan
| | - Shinji Sato
- RICOH Futures BU, RICOH Company, Ltd., 2-3-10 Kandasurugadai, Chiyoda-ku, Tokyo 101-0062, Japan
| | - Yoichi Tani
- Department of Orthopedic Surgery, Graduate School of Medicine, Kansai Medical University, 2-5-1 Shin-machi, Hirakata, Osaka 573-1010, Japan
| | - Masayuki Ishihara
- Department of Orthopedic Surgery, Graduate School of Medicine, Kansai Medical University, 2-5-1 Shin-machi, Hirakata, Osaka 573-1010, Japan
| | - Takashi Adachi
- Department of Orthopedic Surgery, Graduate School of Medicine, Kansai Medical University, 2-5-1 Shin-machi, Hirakata, Osaka 573-1010, Japan
| | - Shinichirou Taniguchi
- Department of Orthopedic Surgery, Graduate School of Medicine, Kansai Medical University, 2-5-1 Shin-machi, Hirakata, Osaka 573-1010, Japan
| | - Nobuo Kohara
- Department of Orthopedic Surgery, Graduate School of Medicine, Kansai Medical University, 2-5-1 Shin-machi, Hirakata, Osaka 573-1010, Japan
| | - Takanori Saito
- Department of Orthopedic Surgery, Graduate School of Medicine, Kansai Medical University, 2-5-1 Shin-machi, Hirakata, Osaka 573-1010, Japan
| |
Collapse
|
6
|
Detailed magnetoelectric analysis of a nerve impulse propagation along the brachial plexus. Clin Neurophysiol 2023; 145:129-138. [PMID: 36280574 DOI: 10.1016/j.clinph.2022.09.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 09/02/2022] [Accepted: 09/25/2022] [Indexed: 11/21/2022]
Abstract
OBJECTIVE To visualize impulse conduction along the brachial plexus through simultaneous electromagnetic measurements. METHODS Neuromagnetic fields following median nerve stimulation were recorded above the clavicle with a superconducting quantum interference device biomagnetometer system in 7 healthy volunteers. Compound nerve action potentials (CNAPs) were obtained from 12 locations. Pseudocolor maps of equivalent currents reconstructed from magnetic fields and isopotential contour maps were superimposed onto X-ray images. Surface potentials and current waveforms at virtual electrodes along the brachial plexus were compared. RESULTS In magnetic field analysis, the leading axonal current followed by a trailing backward current traveled rostrally along the brachial plexus. The spatial extent of the longitudinal intra-axonal currents corresponded to the extent of the positive-negative-positive potential field reflecting transmembrane volume currents. The peaks and troughs of the intra-axonal biphasic current waveforms coincided with the zero-crossings of triphasic CNAP waveforms. The amplitudes of CNAPs and current moments were linearly correlated. CONCLUSIONS Reconstructed neural activity in magnetic field analysis visualizes not only intra-axonal currents, but also transmembrane volume currents, which are in good agreement with the surface potential field. SIGNIFICANCE Magnetoneurography is a novel non-invasive functional imaging modality for the brachial plexus whose performance can surpass that of electric potential measurement.
Collapse
|
7
|
Afra P. Magnetoneurography: A neurophysiological window to the brachial plexus. Clin Neurophysiol 2023; 145:102-103. [PMID: 36371362 DOI: 10.1016/j.clinph.2022.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 10/25/2022] [Indexed: 11/06/2022]
Affiliation(s)
- Pegah Afra
- Department of Neurology, University of Utah, Salt Lake City, UT, USA.
| |
Collapse
|
8
|
Koh RGL, Zariffa J, Jabban L, Yen SC, Donaldson N, Metcalfe BW. Tutorial: A guide to techniques for analysing recordings from the peripheral nervous system. J Neural Eng 2022; 19. [PMID: 35772397 DOI: 10.1088/1741-2552/ac7d74] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 06/30/2022] [Indexed: 11/11/2022]
Abstract
The nervous system, through a combination of conscious and automatic processes, enables the regulation of the body and its interactions with the environment. The peripheral nervous system is an excellent target for technologies that seek to modulate, restore or enhance these abilities as it carries sensory and motor information that most directly relates to a target organ or function. However, many applications require a combination of both an effective peripheral nerve interface and effective signal processing techniques to provide selective and stable recordings. While there are many reviews on the design of peripheral nerve interfaces, reviews of data analysis techniques and translational considerations are limited. Thus, this tutorial aims to support new and existing researchers in the understanding of the general guiding principles, and introduces a taxonomy for electrode configurations, techniques and translational models to consider.
Collapse
Affiliation(s)
- Ryan G L Koh
- IBBME, University of Toronto, Rosebrugh Bldg, 164 College St Room 407, Toronto, Ontario, M5S 3G9, CANADA
| | - Jose Zariffa
- Research, Toronto Rehabilitation Institute - University Health Network, 550 University Ave, #12-102, Toronto, Ontario, M5G 2A2, CANADA
| | - Leen Jabban
- Electronic and Electrical Engineering, University of Bath, Electronic and Electrical Engineering, Claverton Down, Bath, Bath, BA2 7AY, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Shih-Cheng Yen
- Engineering Design and Innovation Centre, National University of Singapore, 21 Lower Kent Ridge Road, Singapore, 119077, SINGAPORE
| | - Nick Donaldson
- Medical Physics and Bioengineering, University College London, Gower Street, London, WC1E 6BT, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Benjamin W Metcalfe
- Electronics & Electrical Engineering, University of Bath, Claverton Down, Bath, Somerset, BA2 7JY, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| |
Collapse
|
9
|
Magnetoneurography as a novel functional imaging technique for the ulnar nerve at the elbow. Clin Neurophysiol 2022; 138:153-162. [DOI: 10.1016/j.clinph.2022.03.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 03/16/2022] [Accepted: 03/18/2022] [Indexed: 11/18/2022]
|
10
|
Akaza M, Kawabata S, Ozaki I, Miyano Y, Watanabe T, Adachi Y, Sekihara K, Sumi Y, Yokota T. Noninvasive measurement of sensory action currents in the cervical cord by magnetospinography. Clin Neurophysiol 2021; 132:382-391. [PMID: 33450561 DOI: 10.1016/j.clinph.2020.11.029] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Revised: 10/29/2020] [Accepted: 11/06/2020] [Indexed: 10/22/2022]
Abstract
OBJECTIVE To obtain magnetic recordings of electrical activities in the cervical cord and visualize sensory action currents of the dorsal column, intervertebral foramen, and dorsal horn. METHODS Neuromagnetic fields were measured at the neck surface upon median nerve stimulation at the wrist using a magnetospinography system with high-sensitivity superconducting quantum interference device sensors. Somatosensory evoked potentials (SEPs) were also recorded. Evoked electrical currents were reconstructed by recursive null-steering beamformer and superimposed on cervical X-ray images. RESULTS Estimated electrical currents perpendicular to the cervical cord ascended sequentially. Their peak latency at C5 and N11 peak latency of SEP were well-correlated in all 16 participants (r = 0.94, p < 0.0001). Trailing axonal currents in the intervertebral foramens were estimated in 10 participants. Estimated dorsal-ventral electrical currents were obtained within the spinal canal at C5. Current density peak latency significantly correlated with cervical N13-P13 peak latency of SEPs in 13 participants (r = 0.97, p < 0.0001). CONCLUSIONS Magnetospinography shows excellent spatial and temporal resolution after median nerve stimulation and can identify the spinal root entry level, calculate the dorsal column conduction velocity, and analyze segmental dorsal horn activity. SIGNIFICANCE This approach is useful for functional electrophysiological diagnosis of somatosensory pathways.
Collapse
Affiliation(s)
- Miho Akaza
- Respiratory and Nervous System Science, Biomedical Laboratory Science, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan.
| | - Shigenori Kawabata
- Department of Advanced Technology in Medicine, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan.
| | - Isamu Ozaki
- Department of Physical Therapy, Faculty of Health Sciences, Aomori University of Health and Welfare, 58-1 Mase, Hamadate, Aomori 030-8505, Japan.
| | - Yuki Miyano
- Healthcare Business Group, RICOH Company, Ltd., 2-3-10 Kandasurugadai Chiyoda-ku, Tokyo 101-0062, Japan.
| | - Taishi Watanabe
- Healthcare Business Group, RICOH Company, Ltd., 2-3-10 Kandasurugadai Chiyoda-ku, Tokyo 101-0062, Japan.
| | - Yoshiaki Adachi
- Applied Electronics Laboratory, Kanazawa Institute of Technology, 7-1 Ogigaoka, Nonoichi, Ishikawa 921-8501, Japan
| | - Kensuke Sekihara
- Department of Advanced Technology in Medicine, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan.
| | - Yuki Sumi
- Respiratory and Nervous System Science, Biomedical Laboratory Science, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan.
| | - Takanori Yokota
- Department of Neurology and Neurological Science, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan.
| |
Collapse
|
11
|
Rubin DI. Brachial and lumbosacral plexopathies: A review. Clin Neurophysiol Pract 2020; 5:173-193. [PMID: 32954064 PMCID: PMC7484503 DOI: 10.1016/j.cnp.2020.07.005] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Revised: 07/09/2020] [Accepted: 07/31/2020] [Indexed: 12/11/2022] Open
Abstract
Diseases of the brachial and lumbosacral plexus are uncommon and complex. The diagnosis of plexopathies is often challenging for the clinician, both in terms of localizing a patient's symptoms to the plexus as well as determining the etiology. The non-specific clinical features and similar presentations to other root, nerve, and non-neurologic disorders emphasize the importance of a high clinical index of suspicion for a plexopathy and comprehensive clinical evaluation. Various diagnostic tests, including electrodiagnostic (EDX) studies, neuroimaging (including ultrasound, MRI, or PET), serologic studies, and genetic testing, may be used to confirm a plexopathy and assist in identifying the underlying etiology. EDX testing plays an important role in confirming a plexopathy defining the localization, pathophysiology, chronicity, severity, and prognosis. Given the complexity of the plexus anatomy, multiple common and uncommon NCS and an extensive needle examination is often required, and a comprehensive, individualized approach to each patient is necessary. Treatment of plexopathies often focuses on symptomatic management although, depending on the etiology, specific targeted treatments may improve outcome. This article reviews the clinical features, EDX approaches, and evaluation and treatment of brachial and lumbosacral plexopathies.
Collapse
Affiliation(s)
- Devon I. Rubin
- Electromyography Laboratory, Mayo Clinic, Jacksonville, FL, USA
| |
Collapse
|