1
|
Kueht M, Jindra P, Stevenson HL, Galvan TN, Murthy B, Goss J, Anton J, Abbas R, Cusick MF. Intra-operative kinetics of anti-HLA antibody in simultaneous liver-kidney transplantation. Mol Genet Metab Rep 2021; 26:100705. [PMID: 33489761 PMCID: PMC7811052 DOI: 10.1016/j.ymgmr.2020.100705] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 12/27/2020] [Accepted: 12/28/2020] [Indexed: 11/05/2022] Open
Abstract
During simultaneous liver-kidney transplantation (SLK) in highly sensitized patients, donor specific anti-human leukocyte antigen antibodies (DSA, HLA) can be present prior to transplant leading to positive crossmatch, yet these recipients have relatively low incidences of acute rejection. The mechanisms and timing underlying immunologic changes that occur intra-operatively remain largely unknown. Therefore, we measured the intra- and peri-operative kinetics of anti-HLA antibodies in highly sensitized SLK recipients. In this study, pre- and post-operative blood samples were obtained from sensitized SLK candidates with documented DSA. Intra-operative samples were obtained from a sub-group of SLK recipients. Pretransplant anti-HLA antibody profiles were created and flow cytometry and anti-human globulin complement-dependent cytotoxic crossmatches were performed. Significant reductions in anti-HLA class I and II DSA were seen intra-operatively shortly after reperfusion of the liver allograft. This effect was most pronounced for anti-HLA class I DSA (mean change, −85%, p < 0.05); changes to anti-HLA class II DSA were less robust (mean change, −47%, p = 0.15). Importantly, non-DSA anti-HLA antibodies remained unchanged throughout the perioperative period, suggesting the mechanism(s) by which the liver lowers DSA levels are specific to the DSA. These data demonstrate the immunologic benefit of performing SLK is lasting and occurs very shortly after liver reperfusion.
Collapse
Affiliation(s)
- M Kueht
- Department of Surgery, University of Texas Medical Branch, 301 University Boulevard, Galveston, TX 77555, United States of America
| | - P Jindra
- Department of Surgery, Baylor College of Medicine, One Baylor Plaza, MS:BCM 504, Houston, TX 77030, United States of America
| | - H L Stevenson
- Department of Pathology, University of Texas Medical Branch, 301 University Boulevard, Galveston, TX 77555, United States of America
| | - T N Galvan
- Department of Surgery, Baylor College of Medicine, One Baylor Plaza, MS:BCM 504, Houston, TX 77030, United States of America
| | - B Murthy
- Department of Surgery, Baylor College of Medicine, One Baylor Plaza, MS:BCM 504, Houston, TX 77030, United States of America
| | - J Goss
- Department of Surgery, Baylor College of Medicine, One Baylor Plaza, MS:BCM 504, Houston, TX 77030, United States of America
| | - J Anton
- Department of Surgery, Baylor College of Medicine, One Baylor Plaza, MS:BCM 504, Houston, TX 77030, United States of America
| | - R Abbas
- Department of Surgery, Baylor College of Medicine, One Baylor Plaza, MS:BCM 504, Houston, TX 77030, United States of America
| | - M F Cusick
- Department of Pathology, University of Michigan Medicine, 2800 Plymouth Rd., Building 36, Ann Arbor, MI 48109, United States of America
| |
Collapse
|
2
|
Human Leukocyte Antigen Examination Using Luminex®-Based Assays for Donor-Recipient Compatibility Assessment in Kidney Transplantation: Our Preliminary Experience. Nephrourol Mon 2020. [DOI: 10.5812/numonthly.104635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Background: Detection of anti-HLA antibodies (HLAabs) in organ transplantation recipients is vital to determine whether the recipient has specific HLAabs against the donor’s HLA molecules (donor-specific anti-HLA antibodies [DSA]). Methods: This preliminary study involved seven subjects: five without prior HLA sensitization and two with a history of possible HLA sensitization (kidney transplantation and pregnancy). Two of the subjects were siblings, two of the subjects were mother and son, and two of them were first cousins once removed. All the subjects underwent HLA typing, and four of the subjects underwent HLAabs assays using the sequence-specific oligonucleotide probes (SSOP) method. Results: There were 10/16 HLA matches between subjects who were siblings and between subjects who were mother and son, and 6/16 HLA matches were found between subjects who were first cousins once removed. Subjects with previous kidney transplantation developed 59 HLA-Abs toward class I and class II HLA (the mean fluorescence intensity (MFI) value range: 1,003.36 to 12,404.77). HLAabs were also found among subjects without prior HLA sensitization, albeit with relatively lower MFI values. Conclusions: HLA typing and HLAabs detection for donor-recipient compatibility assessment using the SSOP method offers more detailed, semi-quantitative results. Further research involving larger subjects in cohort settings will be useful for profiling MFI cut-off values for HLAabs.
Collapse
|