1
|
Wen C, Li B, Yang Y, Feng Y, Liu J, Zhang L, Zhang Y, Li N, Liu J, Wang L, Zhang M, Liu Y. WITHDRAWN: Coronary artery segmentation based on ACMA-Net and unscented Kalman filter algorithm. Comput Biol Med 2024:108615. [PMID: 38910075 DOI: 10.1016/j.compbiomed.2024.108615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 03/30/2024] [Accepted: 05/11/2024] [Indexed: 06/25/2024]
Abstract
This article has been withdrawn at the request of the author(s) and/or editor. The Publisher apologizes for any inconvenience this may cause. The full Elsevier Policy on Article Withdrawal can be found at https://www.elsevier.com/about/policies/article-withdrawal.
Collapse
Affiliation(s)
- Chuanqi Wen
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China.
| | - Bao Li
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China
| | - Yang Yang
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China
| | - Yili Feng
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China
| | - Jincheng Liu
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China
| | - Liyuan Zhang
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China
| | - Yanping Zhang
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China
| | - Na Li
- Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, 271016, China
| | - Jian Liu
- Department of Cardiology, Peking University People's Hospital, Beijing, 100444, China
| | - Lihua Wang
- Department of Radiology, The Second Affiliated Hospital of Zhejiang University School of Medicine, Zhejiang, 310003, China
| | - Mingzi Zhang
- Department of Biomedical Sciences, Macquarie Medical School, Macquarie University, Sydney, Australia
| | - Youjun Liu
- Department of Biomedical Engineering, Faculty of Environment and Life, Beijing University of Technology, Beijing, 100124, China
| |
Collapse
|
2
|
Sun Q, Yang J, Ma S, Huang Y, Yuan Y, Hou Y. 3D vessel extraction using a scale-adaptive hybrid parametric tracker. Med Biol Eng Comput 2023; 61:2467-2480. [PMID: 37184591 DOI: 10.1007/s11517-023-02815-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2022] [Accepted: 02/28/2023] [Indexed: 05/16/2023]
Abstract
3D vessel extraction has great significance in the diagnosis of vascular diseases. However, accurate extraction of vessels from computed tomography angiography (CTA) data is challenging. For one thing, vessels in different body parts have a wide range of scales and large curvatures; for another, the intensity distributions of vessels in different CTA data vary considerably. Besides, surrounding interfering tissue, like bones or veins with similar intensity, also seriously affects vessel extraction. Considering all the above imaging and structural features of vessels, we propose a new scale-adaptive hybrid parametric tracker (SAHPT) to extract arbitrary vessels of different body parts. First, a geometry-intensity parametric model is constructed to calculate the geometry-intensity response. While geometry parameters are calculated to adapt to the variation in scale, intensity parameters can also be estimated to meet non-uniform intensity distributions. Then, a gradient parametric model is proposed to calculate the gradient response based on a multiscale symmetric normalized gradient filter which can effectively separate the target vessel from surrounding interfering tissue. Last, a hybrid parametric model that combines the geometry-intensity and gradient parametric models is constructed to evaluate how well it fits a local image patch. In the extraction process, a multipath spherical sampling strategy is used to solve the problem of anatomical complexity. We have conducted many quantitative experiments using the synthetic and clinical CTA data, asserting its superior performance compared to traditional or deep learning-based baselines.
Collapse
Affiliation(s)
- Qi Sun
- Key Laboratory of Intelligent Computing in Medical Image, Ministry of Education, Northeastern University, Shenyang, Liaoning, China
- School of Computer Science and Engineering, Northeastern University, Shenyang, Liaoning, China
| | - Jinzhu Yang
- Key Laboratory of Intelligent Computing in Medical Image, Ministry of Education, Northeastern University, Shenyang, Liaoning, China.
- School of Computer Science and Engineering, Northeastern University, Shenyang, Liaoning, China.
| | - Shuang Ma
- Key Laboratory of Intelligent Computing in Medical Image, Ministry of Education, Northeastern University, Shenyang, Liaoning, China
- School of Computer Science and Engineering, Northeastern University, Shenyang, Liaoning, China
| | - Yan Huang
- Key Laboratory of Intelligent Computing in Medical Image, Ministry of Education, Northeastern University, Shenyang, Liaoning, China
- School of Computer Science and Engineering, Northeastern University, Shenyang, Liaoning, China
| | - Yuliang Yuan
- Key Laboratory of Intelligent Computing in Medical Image, Ministry of Education, Northeastern University, Shenyang, Liaoning, China
- School of Computer Science and Engineering, Northeastern University, Shenyang, Liaoning, China
| | - Yang Hou
- Department of Radiology, ShengJing Hospital of China Medical University, Shenyang, Liaoning, China
| |
Collapse
|
3
|
Agbalessi M, Lalande A, Bouchot O, Hayase T, Christophe JJ, Fernández MA, Lombardi D. Tracking of Blood Vessels Motion from 4D-flow MRI Data. Cardiovasc Eng Technol 2023; 14:577-604. [PMID: 37578731 DOI: 10.1007/s13239-023-00677-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Accepted: 07/19/2023] [Indexed: 08/15/2023]
Abstract
This paper presents a novel approach to track objects from 4D-flow MRI data. A salient feature of the proposed method is that it fully exploits the geometrical and dynamical nature of the information provided by this imaging modality. The underlying idea consists in formulating the tracking problem as a data assimilation problem, in which both position and velocity observations are extracted from the 4D-flow MRI data series. Optimal state estimation is then performed in a sequential fashion via Kalman filtering. The capabilities of the method are extensively assessed in a numerical study involving synthetic and clinical data.
Collapse
Affiliation(s)
- Mocia Agbalessi
- Sorbonne Université, CNRS, Inria, Paris, France
- ImVia Laboratory, University of Burgundy, Dijon, France
| | - Alain Lalande
- ImVia Laboratory, University of Burgundy, Dijon, France
- Department of Magnetic Resonance Imaging, Dijon University Hospital, Dijon, France
| | - Olivier Bouchot
- Department of Cardiovascular and Thoracic Surgery, Dijon University Hospital, Dijon, France
| | | | | | | | | |
Collapse
|
4
|
Li L, Liu H, Li Q, Tian Z, Li Y, Geng W, Wang S. Near-Infrared Blood Vessel Image Segmentation Using Background Subtraction and Improved Mathematical Morphology. Bioengineering (Basel) 2023; 10:726. [PMID: 37370657 DOI: 10.3390/bioengineering10060726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 05/31/2023] [Accepted: 06/06/2023] [Indexed: 06/29/2023] Open
Abstract
The precise display of blood vessel information for doctors is crucial. This is not only true for facilitating intravenous injections, but also for the diagnosis and analysis of diseases. Currently, infrared cameras can be used to capture images of superficial blood vessels. However, their imaging quality always has the problems of noises, breaks, and uneven vascular information. In order to overcome these problems, this paper proposes an image segmentation algorithm based on the background subtraction and improved mathematical morphology. The algorithm regards the image as a superposition of blood vessels into the background, removes the noise by calculating the size of connected domains, achieves uniform blood vessel width, and smooths edges that reflect the actual blood vessel state. The algorithm is evaluated subjectively and objectively in this paper to provide a basis for vascular image quality assessment. Extensive experimental results demonstrate that the proposed method can effectively extract accurate and clear vascular information.
Collapse
Affiliation(s)
- Ling Li
- Beijing Engineerin Research Center of Industrial Spectrum Imaging, School of Automation and Electrical Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Haoting Liu
- Beijing Engineerin Research Center of Industrial Spectrum Imaging, School of Automation and Electrical Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Qing Li
- Beijing Engineerin Research Center of Industrial Spectrum Imaging, School of Automation and Electrical Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Zhen Tian
- Beijing Engineerin Research Center of Industrial Spectrum Imaging, School of Automation and Electrical Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Yajie Li
- Beijing Engineerin Research Center of Industrial Spectrum Imaging, School of Automation and Electrical Engineering, University of Science and Technology Beijing, Beijing 100083, China
| | - Wenjia Geng
- Department of Traditional Chinese Medicine, Peking University People's Hospital, Beijing 100044, China
| | - Song Wang
- Department of Nephrology, Peking University Third Hospital, Beijing 100191, China
| |
Collapse
|
5
|
A skeleton context-aware 3D fully convolutional network for abdominal artery segmentation. Int J Comput Assist Radiol Surg 2023; 18:461-472. [PMID: 36273078 DOI: 10.1007/s11548-022-02767-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Accepted: 09/26/2022] [Indexed: 11/05/2022]
Abstract
PURPOSE This paper aims to propose a deep learning-based method for abdominal artery segmentation. Blood vessel structure information is essential to diagnosis and treatment. Accurate blood vessel segmentation is critical to preoperative planning. Although deep learning-based methods perform well on large organs, segmenting small organs such as blood vessels is challenging due to complicated branching structures and positions. We propose a 3D deep learning network from a skeleton context-aware perspective to improve segmentation accuracy. In addition, we propose a novel 3D patch generation method which could strengthen the structural diversity of a training data set. METHOD The proposed method segments abdominal arteries from an abdominal computed tomography (CT) volume using a 3D fully convolutional network (FCN). We add two auxiliary tasks to the network to extract the skeleton context of abdominal arteries. In addition, our skeleton-based patch generation (SBPG) method further enables the FCN to segment small arteries. SBPG generates a 3D patch from a CT volume by leveraging artery skeleton information. These methods improve the segmentation accuracies of small arteries. RESULTS We used 20 cases of abdominal CT volumes to evaluate the proposed method. The experimental results showed that our method outperformed previous segmentation accuracies. The averaged precision rate, recall rate, and F-measure were 95.5%, 91.0%, and 93.2%, respectively. Compared to a baseline method, our method improved 1.5% the averaged recall rate and 0.7% the averaged F-measure. CONCLUSIONS We present a skeleton context-aware 3D FCN to segment abdominal arteries from an abdominal CT volume. In addition, we propose a 3D patch generation method. Our fully automated method segmented most of the abdominal artery regions. The method produced competitive segmentation performance compared to previous methods.
Collapse
|
6
|
Bai R, Liu X, Jiang S, Sun H. Deep Learning Based Real-Time Semantic Segmentation of Cerebral Vessels and Cranial Nerves in Microvascular Decompression Scenes. Cells 2022; 11:1830. [PMID: 35681525 PMCID: PMC9180010 DOI: 10.3390/cells11111830] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Revised: 05/19/2022] [Accepted: 05/25/2022] [Indexed: 12/03/2022] Open
Abstract
Automatic extraction of cerebral vessels and cranial nerves has important clinical value in the treatment of trigeminal neuralgia (TGN) and hemifacial spasm (HFS). However, because of the great similarity between different cerebral vessels and between different cranial nerves, it is challenging to segment cerebral vessels and cranial nerves in real time on the basis of true-color microvascular decompression (MVD) images. In this paper, we propose a lightweight, fast semantic segmentation Microvascular Decompression Network (MVDNet) for MVD scenarios which achieves a good trade-off between segmentation accuracy and speed. Specifically, we designed a Light Asymmetric Bottleneck (LAB) module in the encoder to encode context features. A Feature Fusion Module (FFM) was introduced into the decoder to effectively combine high-level semantic features and underlying spatial details. The proposed network has no pretrained model, fewer parameters, and a fast inference speed. Specifically, MVDNet achieved 76.59% mIoU on the MVD test set, has 0.72 M parameters, and has a 137 FPS speed using a single GTX 2080Ti card.
Collapse
Affiliation(s)
- Ruifeng Bai
- Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China; (R.B.); (S.J.)
- University of Chinese Academy of Sciences, Beijing 100049, China;
| | - Xinrui Liu
- University of Chinese Academy of Sciences, Beijing 100049, China;
- Department of Neurosurgery, The First Hospital of Jilin University, Changchun 130021, China
| | - Shan Jiang
- Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China; (R.B.); (S.J.)
| | - Haijiang Sun
- Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, China; (R.B.); (S.J.)
| |
Collapse
|
7
|
Sieren MM, Widmann C, Weiss N, Moltz JH, Link F, Wegner F, Stahlberg E, Horn M, Oecherting TH, Goltz JP, Barkhausen J, Frydrychowicz A. Automated segmentation and quantification of the healthy and diseased aorta in CT angiographies using a dedicated deep learning approach. Eur Radiol 2021; 32:690-701. [PMID: 34170365 DOI: 10.1007/s00330-021-08130-2] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Accepted: 03/26/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVES To develop and validate a deep learning-based algorithm for segmenting and quantifying the physiological and diseased aorta in computed tomography angiographies. METHODS CTA exams of the aorta of 191 patients (68.1 ± 14 years, 128 male), performed between 2015 and 2018, were retrospectively identified from our imaging archive and manually segmented by two investigators. A 3D U-Net model was trained on the data, which was divided into a training, a validation, and a test group at a ratio of 7:1:2. Cases in the test group (n = 41) were evaluated to compare manual and automatic segmentations. Dice similarity coefficient (DSC), mean surface distance (MSD), and Hausdorff surface distance (HSD) were extracted. Maximum diameter, effective diameter, and area were quantified and compared between both segmentations at eight anatomical landmarks, and at the maximum area of an aneurysms if present (n = 14). Statistics included error calculation, intraclass correlation coefficient, and Bland-Altman analysis. RESULTS A DSC of 0.95 [0.94; 0.95] and an MSD of 0.76 [0.06; 0.99] indicated close agreement between segmentations. HSD was 8.00 [4.47; 10.00]. The largest absolute errors were found in the ascending aorta with 0.8 ± 1.5 mm for maximum diameter and at the coeliac trunk with - 30.0 ± 81.6 mm2 for area. Results for absolute errors in aneurysms were - 0.5 ± 2.3 mm for maximum diameter, 0.3 ± 1.6 mm for effective diameter, and 64.9 ± 114.9 mm2 for area. ICC showed excellent agreement (> 0.9; p < 0.05) between quantitative measurements. CONCLUSIONS Automated segmentation of the aorta on CTA data using a deep learning algorithm is feasible and allows for accurate quantification of the aortic lumen even if the vascular architecture is altered by disease. KEY POINTS • A deep learning-based algorithm can automatically segment the aorta, mostly within acceptable margins of error, even if the vascular architecture is altered by disease. • Quantifications performed in the segmentations were mostly within clinically acceptable limits, even in pathologically altered segments of the aorta.
Collapse
Affiliation(s)
- Malte Maria Sieren
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany.
| | - Cornelia Widmann
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany
| | - Nick Weiss
- Fraunhofer Institute for Digital Medicine MEVIS, Lübeck/Bremen, Germany
| | - Jan Hendrik Moltz
- Fraunhofer Institute for Digital Medicine MEVIS, Lübeck/Bremen, Germany
| | - Florian Link
- Fraunhofer Institute for Digital Medicine MEVIS, Lübeck/Bremen, Germany
| | - Franz Wegner
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany
| | - Erik Stahlberg
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany
| | - Marco Horn
- Department for Vascular Surgery, University Hospital Schleswig-Holstein, Campus Lübeck, Lübeck, Germany
| | - Thekla Helene Oecherting
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany
| | - Jan Peter Goltz
- Institute for Diagnostic and Interventional Radiology/Neuroradiology, Sana Clinic, Lübeck, Germany
| | - Joerg Barkhausen
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany
| | - Alex Frydrychowicz
- Department of Radiology and Nuclear Medicine, University Hospital Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23562, Lübeck, Germany
| |
Collapse
|
8
|
A method to improve the computational efficiency of the Chan-Vese model for the segmentation of ultrasound images. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.102560] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
9
|
Song S, Du C, Chen Y, Ai D, Song H, Huang Y, Wang Y, Yang J. Inter/intra-frame constrained vascular segmentation in X-ray angiographic image sequence. BMC Med Inform Decis Mak 2019; 19:270. [PMID: 31856807 PMCID: PMC6921392 DOI: 10.1186/s12911-019-0966-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
Background Automatic vascular segmentation in X-ray angiographic image sequence is of crucial interest, for instance, for better quantifying coronary arteries in diagnostic and interventional procedures. Methods A novel inter/intra-frame constrained vascular segmentation method is proposed to automatically segment vessels in coronary X-ray angiographic image sequence. First, a morphological filter operator is applied to remove structures undergoing the respiratory motion from the original image sequence. Second, an inter-frame constrained robust principal component analysis (RPCA) is utilized to remove the quasi-static structures from the image sequence. Third, an intra-frame constrained RPCA is employed to smooth the final extracted vascular sequence. Fourth, a multi-feature fusion is designed to improve the vascular contrast and the final vascular segmentation is realized by thresholding-based method. Results Experiments are conducted on 22 clinical X-ray angiographic image sequences. The global and local contrast-to-noise ratio of the proposed method are 6.6344 and 4.2882, respectively. And the precision, sensitivity and F1 value are 0.7378, 0.7960 and 0.7658, respectively. It demonstrates that our method is effective and robust for vascular segmentation from image sequence. Conclusions The proposed method is effective to remove non-vascular structures, reduce motion artefacts and other non-uniform illumination caused noises. Also, the proposed method is online which can just process one image per time without re-optimizing the model.
Collapse
Affiliation(s)
- Shuang Song
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China
| | - Chenbing Du
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China
| | - Ying Chen
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China
| | - Danni Ai
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China
| | - Hong Song
- AICFVE of Beijing Film Academy, 4 Xitucheng Rd, Haidian, Beijing, 100088, China
| | - Yong Huang
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China
| | - Yongtian Wang
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China.,School of Computer Science & Technology, Beijing Institute of Technology, Beijing, 100081, China
| | - Jian Yang
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, China.
| |
Collapse
|
10
|
Kang J, Heo S, Hyung WJ, Lim JS, Lee S. 3D Active Vessel Tracking Using an Elliptical Prior. IEEE TRANSACTIONS ON IMAGE PROCESSING : A PUBLICATION OF THE IEEE SIGNAL PROCESSING SOCIETY 2018; 27:5933-5946. [PMID: 30072325 DOI: 10.1109/tip.2018.2862346] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
In this paper, we propose a novel vessel tracking method, called active vessel tracking (AVT). The proposed method retains the major advantages that most 2D segmentation methods have demonstrated for 3D tracking while overcoming the drawbacks of previous 3D vessel tracking methods. Under the assumption that the vessel is cylindrical, thereby making its cross-section elliptical, the AVT finds a plane perpendicular to the vessel axis while tracking the vessel along its length. Also, We propose a method for vessel branch detection to automatically track complete vascular networks from a single starting point, whereas the previously proposed solutions have usually been limited in handling vessel bifurcations precisely on 3D or have required considerable user interaction. Our results show that the method is robust and accurate in both synthetic and clinical cases. In an experiment on synthetic data sets, the proposed method achieved a tracking accuracy of 96.1±0.5, detecting 99.1% of the branches. In an experiment on abdominal CTA data sets, it achieved a tracking accuracy of 98.4±0.5 for six target vessels, detecting 98.3% of the branches. These results show that the proposed method can outperform previous methods for vessel tracking.
Collapse
|
11
|
Zhao S, Gao Z, Zhang H, Xie Y, Luo J, Ghista D, Wei Z, Bi X, Xiong H, Xu C, Li S. Robust Segmentation of Intima–Media Borders With Different Morphologies and Dynamics During the Cardiac Cycle. IEEE J Biomed Health Inform 2018; 22:1571-1582. [DOI: 10.1109/jbhi.2017.2776246] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
12
|
Moccia S, De Momi E, El Hadji S, Mattos LS. Blood vessel segmentation algorithms - Review of methods, datasets and evaluation metrics. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2018; 158:71-91. [PMID: 29544791 DOI: 10.1016/j.cmpb.2018.02.001] [Citation(s) in RCA: 226] [Impact Index Per Article: 37.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2017] [Revised: 12/23/2017] [Accepted: 02/02/2018] [Indexed: 05/09/2023]
Abstract
BACKGROUND Blood vessel segmentation is a topic of high interest in medical image analysis since the analysis of vessels is crucial for diagnosis, treatment planning and execution, and evaluation of clinical outcomes in different fields, including laryngology, neurosurgery and ophthalmology. Automatic or semi-automatic vessel segmentation can support clinicians in performing these tasks. Different medical imaging techniques are currently used in clinical practice and an appropriate choice of the segmentation algorithm is mandatory to deal with the adopted imaging technique characteristics (e.g. resolution, noise and vessel contrast). OBJECTIVE This paper aims at reviewing the most recent and innovative blood vessel segmentation algorithms. Among the algorithms and approaches considered, we deeply investigated the most novel blood vessel segmentation including machine learning, deformable model, and tracking-based approaches. METHODS This paper analyzes more than 100 articles focused on blood vessel segmentation methods. For each analyzed approach, summary tables are presented reporting imaging technique used, anatomical region and performance measures employed. Benefits and disadvantages of each method are highlighted. DISCUSSION Despite the constant progress and efforts addressed in the field, several issues still need to be overcome. A relevant limitation consists in the segmentation of pathological vessels. Unfortunately, not consistent research effort has been addressed to this issue yet. Research is needed since some of the main assumptions made for healthy vessels (such as linearity and circular cross-section) do not hold in pathological tissues, which on the other hand require new vessel model formulations. Moreover, image intensity drops, noise and low contrast still represent an important obstacle for the achievement of a high-quality enhancement. This is particularly true for optical imaging, where the image quality is usually lower in terms of noise and contrast with respect to magnetic resonance and computer tomography angiography. CONCLUSION No single segmentation approach is suitable for all the different anatomical region or imaging modalities, thus the primary goal of this review was to provide an up to date source of information about the state of the art of the vessel segmentation algorithms so that the most suitable methods can be chosen according to the specific task.
Collapse
Affiliation(s)
- Sara Moccia
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy; Department of Advanced Robotics, Istituto Italiano di Tecnologia, Genoa, Italy.
| | - Elena De Momi
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Sara El Hadji
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.
| | - Leonardo S Mattos
- Department of Advanced Robotics, Istituto Italiano di Tecnologia, Genoa, Italy
| |
Collapse
|
13
|
Lee SH, Kang J, Lee S. Enhanced particle-filtering framework for vessel segmentation and tracking. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2017; 148:99-112. [PMID: 28774443 DOI: 10.1016/j.cmpb.2017.06.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2016] [Revised: 05/25/2017] [Accepted: 06/23/2017] [Indexed: 06/07/2023]
Abstract
BACKGROUND AND OBJECTIVES A robust vessel segmentation and tracking method based on a particle-filtering framework is proposed to cope with increasing demand for a method that can detect and track vessel anomalies. METHODS We apply the level set method to segment the vessel boundary and a particle filter to track the position and shape variations in the vessel boundary between two adjacent slices. To enhance the segmentation and tracking performances, the importance density of the particle filter is localized by estimating the translation of an object's boundary. In addition, to minimize problems related to degeneracy and sample impoverishment in the particle filter, a newly proposed weighting policy is investigated. RESULTS Compared to conventional methods, the proposed algorithm demonstrates better segmentation and tracking performances. Moreover, the stringent weighting policy we proposed demonstrates a tendency of suppressing degeneracy and sample impoverishment, and higher tracking accuracy can be obtained. CONCLUSIONS The proposed method is expected to be applied to highly valuable applications for more accurate three-dimensional vessel tracking and rendering.
Collapse
Affiliation(s)
- Sang-Hoon Lee
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, 120-749, Republic of Korea
| | - Jiwoo Kang
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, 120-749, Republic of Korea
| | - Sanghoon Lee
- Department of Electrical and Electronic Engineering, Yonsei University, Seoul, 120-749, Republic of Korea.
| |
Collapse
|
14
|
Topology Adaptive Water Boundary Extraction Based on a Modified Balloon Snake: Using GF-1 Satellite Images as an Example. REMOTE SENSING 2017. [DOI: 10.3390/rs9020140] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|