1
|
Li M, Fan Y, Sun S, Jia L, Liang T. Efficient entry point encoding and decoding algorithms on 2D Hilbert space filling curve. MATHEMATICAL BIOSCIENCES AND ENGINEERING : MBE 2023; 20:20668-20682. [PMID: 38124570 DOI: 10.3934/mbe.2023914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2023]
Abstract
The Hilbert curve is an important method for mapping high-dimensional spatial information into one-dimensional spatial information while preserving the locality in the high-dimensional space. Entry points of a Hilbert curve can be used for image compression, dimensionality reduction, corrupted image detection and many other applications. As far as we know, there is no specific algorithms developed for entry points. To address this issue, in this paper we present an efficient entry point encoding algorithm (EP-HE) and a corresponding decoding algorithm (EP-HD). These two algorithms are efficient by exploiting the m consecutive 0s in the rear part of an entry point. We further found that the outputs of these two algorithms are a certain multiple of a certain bit of s, where s is the starting state of these m levels. Therefore, the results of these m levels can be directly calculated without iteratively encoding and decoding. The experimental results show that these two algorithms outperform their counterparts in terms of processing entry points.
Collapse
Affiliation(s)
- Mengjuan Li
- Library, Yunnan Normal University, Kunming 650500, China
| | - Yao Fan
- Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650500, China
| | - Shaowen Sun
- Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650500, China
| | - Lianyin Jia
- Faculty of Information Engineering and Automation, Kunming University of Science and Technology, Kunming 650500, China
| | - Teng Liang
- School of Communications Information Engineering, Yunnan Communications Vocational and Technical College, Kunming 650500, China
| |
Collapse
|
2
|
Gao Y, Lin J, Zhou Y, Lin R. The application of traditional machine learning and deep learning techniques in mammography: a review. Front Oncol 2023; 13:1213045. [PMID: 37637035 PMCID: PMC10453798 DOI: 10.3389/fonc.2023.1213045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Accepted: 07/25/2023] [Indexed: 08/29/2023] Open
Abstract
Breast cancer, the most prevalent malignant tumor among women, poses a significant threat to patients' physical and mental well-being. Recent advances in early screening technology have facilitated the early detection of an increasing number of breast cancers, resulting in a substantial improvement in patients' overall survival rates. The primary techniques used for early breast cancer diagnosis include mammography, breast ultrasound, breast MRI, and pathological examination. However, the clinical interpretation and analysis of the images produced by these technologies often involve significant labor costs and rely heavily on the expertise of clinicians, leading to inherent deviations. Consequently, artificial intelligence(AI) has emerged as a valuable technology in breast cancer diagnosis. Artificial intelligence includes Machine Learning(ML) and Deep Learning(DL). By simulating human behavior to learn from and process data, ML and DL aid in lesion localization reduce misdiagnosis rates, and improve accuracy. This narrative review provides a comprehensive review of the current research status of mammography using traditional ML and DL algorithms. It particularly highlights the latest advancements in DL methods for mammogram image analysis and offers insights into future development directions.
Collapse
Affiliation(s)
- Ying’e Gao
- School of Nursing Fujian Medical University, Fuzhou, China
| | - Jingjing Lin
- School of Nursing Fujian Medical University, Fuzhou, China
| | - Yuzhuo Zhou
- Department of Surgery, Hannover Medical School, Hannover, Germany
| | - Rongjin Lin
- School of Nursing Fujian Medical University, Fuzhou, China
- Department of Nursing, the First Affiliated Hospital of Fujian Medical University, Fuzhou, China
| |
Collapse
|
3
|
Loizidou K, Elia R, Pitris C. Computer-aided breast cancer detection and classification in mammography: A comprehensive review. Comput Biol Med 2023; 153:106554. [PMID: 36646021 DOI: 10.1016/j.compbiomed.2023.106554] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 12/13/2022] [Accepted: 01/11/2023] [Indexed: 01/15/2023]
Abstract
Cancer is the second cause of mortality worldwide and it has been identified as a perilous disease. Breast cancer accounts for ∼20% of all new cancer cases worldwide, making it a major cause of morbidity and mortality. Mammography is an effective screening tool for the early detection and management of breast cancer. However, the identification and interpretation of breast lesions is challenging even for expert radiologists. For that reason, several Computer-Aided Diagnosis (CAD) systems are being developed to assist radiologists to accurately detect and/or classify breast cancer. This review examines the recent literature on the automatic detection and/or classification of breast cancer in mammograms, using both conventional feature-based machine learning and deep learning algorithms. The review begins with a comparison of algorithms developed specifically for the detection and/or classification of two types of breast abnormalities, micro-calcifications and masses, followed by the use of sequential mammograms for improving the performance of the algorithms. The available Food and Drug Administration (FDA) approved CAD systems related to triage and diagnosis of breast cancer in mammograms are subsequently presented. Finally, a description of the open access mammography datasets is provided and the potential opportunities for future work in this field are highlighted. The comprehensive review provided here can serve both as a thorough introduction to the field but also provide indicative directions to guide future applications.
Collapse
Affiliation(s)
- Kosmia Loizidou
- KIOS Research and Innovation Center of Excellence, Department of Electrical and Computer Engineering, University of Cyprus, Nicosia, Cyprus.
| | - Rafaella Elia
- KIOS Research and Innovation Center of Excellence, Department of Electrical and Computer Engineering, University of Cyprus, Nicosia, Cyprus.
| | - Costas Pitris
- KIOS Research and Innovation Center of Excellence, Department of Electrical and Computer Engineering, University of Cyprus, Nicosia, Cyprus.
| |
Collapse
|
4
|
Jungblut L, Blüthgen C, Polacin M, Messerli M, Schmidt B, Euler A, Alkadhi H, Frauenfelder T, Martini K. First Performance Evaluation of an Artificial Intelligence-Based Computer-Aided Detection System for Pulmonary Nodule Evaluation in Dual-Source Photon-Counting Detector CT at Different Low-Dose Levels. Invest Radiol 2022; 57:108-114. [PMID: 34324462 DOI: 10.1097/rli.0000000000000814] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE The aim of this study was to evaluate the image quality (IQ) and performance of an artificial intelligence (AI)-based computer-aided detection (CAD) system in photon-counting detector computed tomography (PCD-CT) for pulmonary nodule evaluation at different low-dose levels. MATERIALS AND METHODS An anthropomorphic chest-phantom containing 14 pulmonary nodules of different sizes (range, 3-12 mm) was imaged on a PCD-CT and on a conventional energy-integrating detector CT (EID-CT). Scans were performed with each of the 3 vendor-specific scanning modes (QuantumPlus [Q+], Quantum [Q], and High Resolution [HR]) at decreasing matched radiation dose levels (volume computed tomography dose index ranging from 1.79 to 0.31 mGy) by adapting IQ levels from 30 to 5. Image noise was measured manually in the chest wall at 8 different locations. Subjective IQ was evaluated by 2 readers in consensus. Nodule detection and volumetry were performed using a commercially available AI-CAD system. RESULTS Subjective IQ was superior in PCD-CT compared with EID-CT (P < 0.001), and objective image noise was similar in the Q+ and Q-mode (P > 0.05) and superior in the HR-mode (PCD 55.8 ± 11.7 HU vs EID 74.8 ± 5.4 HU; P = 0.01). High resolution showed the lowest image noise values among PCD modes (P = 0.01). Overall, the AI-CAD system delivered comparable results for lung nodule detection and volumetry between PCD- and dose-matched EID-CT (P = 0.08-1.00), with a mean sensitivity of 95% for PCD-CT and of 86% for dose-matched EID-CT in the lowest evaluated dose level (IQ5). Q+ and Q-mode showed higher false-positive rates than EID-CT at lower-dose levels (IQ10 and IQ5). The HR-mode showed a sensitivity of 100% with a false-positive rate of 1 even at the lowest evaluated dose level (IQ5; CDTIvol, 0.41 mGy). CONCLUSIONS Photon-counting detector CT was superior to dose-matched EID-CT in subjective IQ while showing comparable to lower objective image noise. Fully automatized AI-aided nodule detection and volumetry are feasible in PCD-CT, but attention has to be paid to false-positive findings.
Collapse
Affiliation(s)
- Lisa Jungblut
- From the Institute of Diagnostic and Interventional Radiology
| | | | | | - Michael Messerli
- Department of Nuclear Medicine, University Hospital Zurich, University of Zurich, Zurich, Switzerland
| | | | - Andre Euler
- From the Institute of Diagnostic and Interventional Radiology
| | - Hatem Alkadhi
- From the Institute of Diagnostic and Interventional Radiology
| | | | | |
Collapse
|
5
|
Wang L, Xu N, Song J. Decoding intra-tumoral spatial heterogeneity on radiological images using the Hilbert curve. Insights Imaging 2021; 12:154. [PMID: 34716809 PMCID: PMC8557226 DOI: 10.1186/s13244-021-01100-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Accepted: 09/26/2021] [Indexed: 12/17/2022] Open
Abstract
Background Current intra-tumoral heterogeneous feature extraction in radiology is limited to the use of a single slice or the region of interest within a few context-associated slices, and the decoding of intra-tumoral spatial heterogeneity using whole tumor samples is rare. We aim to propose a mathematical model of space-filling curve-based spatial correspondence mapping to interpret intra-tumoral spatial locality and heterogeneity. Methods A Hilbert curve-based approach was employed to decode and visualize intra-tumoral spatial heterogeneity by expanding the tumor volume to a two-dimensional (2D) matrix in voxels while preserving the spatial locality of the neighboring voxels. The proposed method was validated using three-dimensional (3D) volumes constructed from lung nodules from the LIDC-IDRI dataset, regular axial plane images, and 3D blocks. Results Dimensionality reduction of the Hilbert volume with a single regular axial plane image showed a sparse and scattered pixel distribution on the corresponding 2D matrix. However, for 3D blocks and lung tumor inside the volume, the dimensionality reduction to the 2D matrix indicated regular and concentrated squares and rectangles. For classification into benign and malignant masses using lung nodules from the LIDC-IDRI dataset, the Inception-V4 indicated that the Hilbert matrix images improved accuracy (85.54% vs. 73.22%, p < 0.001) compared to the original CT images of the test dataset. Conclusions Our study indicates that Hilbert curve-based spatial correspondence mapping is promising for decoding intra-tumoral spatial heterogeneity of partial or whole tumor samples on radiological images. This spatial-locality-preserving approach for voxel expansion enables existing radiomics and convolution neural networks to filter structured and spatially correlated high-dimensional intra-tumoral heterogeneity. Supplementary Information The online version contains supplementary material available at 10.1186/s13244-021-01100-8.
Collapse
Affiliation(s)
- Lu Wang
- School of Health Management, China Medical University, No. 77 Puhe Rd, Shenbei District, Shenyang, 110122, Liaoning, China
| | - Nan Xu
- School of Health Management, China Medical University, No. 77 Puhe Rd, Shenbei District, Shenyang, 110122, Liaoning, China
| | - Jiangdian Song
- School of Health Management, China Medical University, No. 77 Puhe Rd, Shenbei District, Shenyang, 110122, Liaoning, China.
| |
Collapse
|
6
|
Fischer G, De Silvestro A, Müller M, Frauenfelder T, Martini K. Computer-Aided Detection of Seven Chest Pathologies on Standard Posteroanterior Chest X-Rays Compared to Radiologists Reading Dual-Energy Subtracted Radiographs. Acad Radiol 2021; 29:e139-e148. [PMID: 34706849 DOI: 10.1016/j.acra.2021.09.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2021] [Revised: 09/06/2021] [Accepted: 09/21/2021] [Indexed: 11/01/2022]
Abstract
RATIONALE AND OBJECTIVES Retrospective performance evaluation of a computer-aided detection (CAD) system on standard posteroanterior (PA) chest radiographs (PA-CXR) in detection of pulmonary nodules, infectious consolidation, pneumothorax, pleural effusion, aortic calcification, cardiomegaly and rib fractures compared to radiologists analyzing PA-CXR including dual-energy subtraction radiography (further termed as DESR). MATERIALS AND METHODS PA-CXR/DESR images of 197 patients were included. All patients underwent chest CT (gold standard) within a short interval (mean 28 hours). All images were evaluated by three blinded readers for the presence of pulmonary nodules, infectious consolidation, pneumothorax, pleural effusion, aortic calcification, cardiomegaly, and rib fractures. Meanwhile PA-CXR were analyzed by a CAD software. CAD results were compared to the majority result of the three readers. Sensitivity and specificity were calculated. McNemar's test was applied to test for significant differences. Interobserver agreement was defined using Cohen's kappa (κ). RESULTS Sensitivity of the CAD software was significantly higher (p < 0.05) for detection of infectious consolidation and pulmonary nodules (67.9% vs 26.8% and 54% vs 35.6%, respectively; p < 0.001) compared to radiologists analyzing DESR images. For the residual evaluated pathologies no statistical significant differences could be found. Overall, mean inter observer agreement between the three radiologists was moderate (k = 0.534). The best interobserver agreement could be reached for pneumothorax (k = 0.708) and pleural effusion (k = 0.699), while the worst was obtained for rib fractures (k = 0.412). CONCLUSION The CAD system has the potential to improve the detection of infectious consolidation and pulmonary nodules on CXR images.
Collapse
|
7
|
Impact of Vessel Suppressed-CT on Diagnostic Accuracy in Detection of Pulmonary Metastasis and Reading Time. Acad Radiol 2021; 28:988-994. [PMID: 32037256 DOI: 10.1016/j.acra.2020.01.014] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 01/09/2020] [Accepted: 01/09/2020] [Indexed: 11/20/2022]
Abstract
RATIONALE AND OBJECTIVES To assess if vessel suppression (VS) improves nodule detection rate, interreader agreement, and reduces reading time in oncologic chest computed tomography (CT). MATERIAL AND METHODS One-hundred consecutive oncologic patients (65 male; median age 60y) who underwent contrast-enhanced chest CT were retrospectively included. For all exams, additional VS series (ClearRead CT, Riverrain Technologies, Miamisburg) were reconstructed. Two groups of three radiologists each with matched experience were defined. Each group evaluated the SD-CT as well as VS-CT. Each reader marked the presence, size, and position of pulmonary nodules and documented reading time. In addition, for the VS-CT the presence of false positive nodules had to be stated. Cohen's Kappa (k) was used to calculate the interreader-agreement between groups. Reading time was compared using paired t test. RESULTS Nodule detection rate was significantly higher in VS-CT compared to the SD-CT (+21%; p <0.001). Interreader-agreement was higher in the VS-CT (k = 0.431, moderate agreement) compared to SD-CT (k = 0.209, fair agreement). Almost all VS-CT series had false positive findings (97-99 out of 100). Average reading time was significantly shorter in the VS-CT compared to the SD-CT (154 ± 134vs. 194 ± 126; 21%, p<0.001). CONCLUSIONS Vessel suppression increases nodule detection rate, improves interreader agreement, and reduces reading time in chest CT of oncologic patients. Due to false positive results a consensus reading with the SD-CT is essential.
Collapse
|
8
|
Automated diagnosis of breast cancer using parameter optimized kernel extreme learning machine. Biomed Signal Process Control 2020. [DOI: 10.1016/j.bspc.2020.102108] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
9
|
Abstract
AbstractDeep learning has transformed the field of data analysis by dramatically improving the state of the art in various classification and prediction tasks, especially in the area of computer vision. In biomedical engineering, a lot of new work is directed toward surface electromyography (sEMG)-based gesture recognition, often addressed as an image classification problem using convolutional neural networks (CNNs). In this paper, we utilize the Hilbert space-filling curve for the generation of image representations of sEMG signals, which allows the application of typical image processing pipelines such as CNNs on sequence data. The proposed method is evaluated on different state-of-the-art network architectures and yields a significant classification improvement over the approach without the Hilbert curve. Additionally, we develop a new network architecture (MSHilbNet) that takes advantage of multiple scales of an initial Hilbert curve representation and achieves equal performance with fewer convolutional layers.
Collapse
|
10
|
Wang H, Hu Y, Li H, Xie Y, Wang X, Wan W. Preliminary study on identification of estrogen receptor-positive breast cancer subtypes based on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) texture analysis. Gland Surg 2020; 9:622-628. [PMID: 32775251 DOI: 10.21037/gs.2020.04.01] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Background Currently, breast cancer is divided into Luminal A, Luminal B, HER-2 overexpression (HER-2) and basal cell at genetic level. However, the differential diagnosis of estrogen receptor (ER)-positive breast cancer subtypes is rare. Therefore, we aimed to investigate the feasibility of identifying the ER-positive breast cancer subtypes based on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) texture analysis. Methods A retrospective analysis was performed for clinical data of 51 patients with ER-positive breast invasive ductal carcinoma confirmed by surgery and pathology from January 20 to October 2018. FireVoxel texture analysis software was used to delineate the tumor boundary layer by layer. The differences in the above characteristics between Luminal A and Luminal B breast cancer were compared, and the diagnostic efficacy of statistically significant texture parameters for ER-positive breast cancer subtypes was analyzed. Results There were no significant differences in mean, standard deviation (SD), skewness and tumor size between Luminal A and Luminal B groups (P>0.05). The kurtosis, inhomogeneity and entropy could effectively distinguish between the two groups with statistically significant difference (P=0.001, P=0.000, and P=0.000). The area under the receiver operating characteristic (ROC) curve (AUC) of kurtosis, inhomogeneity and entropy diagnosed with malignant mass were 0.832, 0.859 and 0.891, respectively (P<0.01). In addition, the entropy was the best among the three indicators. When the entropy was ≤4.22, the sensitivity of the diagnosis Luminal B was 90.62% and the specificity was 78.95%. Conclusions The texture analysis features based on DCE-MRI can help to identify ER-positive breast cancer subtypes. Entropy can be the best single texture indicator.
Collapse
Affiliation(s)
- Hui Wang
- Department of Radiology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Yunting Hu
- Department of Radiology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Hui Li
- Department of Radiology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Yuanliang Xie
- Department of Radiology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Xiang Wang
- Department of Radiology, The Central Hospital of Wuhan, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| | - Weijia Wan
- Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China
| |
Collapse
|
11
|
Pérez-Benito FJ, Signol F, Pérez-Cortés JC, Pollán M, Pérez-Gómez B, Salas-Trejo D, Casals M, Martínez I, LLobet R. Global parenchymal texture features based on histograms of oriented gradients improve cancer development risk estimation from healthy breasts. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2019; 177:123-132. [PMID: 31319940 DOI: 10.1016/j.cmpb.2019.05.022] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/22/2019] [Revised: 04/30/2019] [Accepted: 05/21/2019] [Indexed: 06/10/2023]
Abstract
BACKGROUND The breast dense tissue percentage on digital mammograms is one of the most commonly used markers for breast cancer risk estimation. Geometric features of dense tissue over the breast and the presence of texture structures contained in sliding windows that scan the mammograms may improve the predictive ability when combined with the breast dense tissue percentage. METHODS A case/control study nested within a screening program covering 1563 women with craniocaudal and mediolateral-oblique mammograms (755 controls and the contralateral breast mammograms at the closest screening visit before cancer diagnostic for 808 cases) aging 45 to 70 from Comunitat Valenciana (Spain) was used to extract geometric and texture features. The dense tissue segmentation was performed using DMScan and validated by two experienced radiologists. A model based on Random Forests was trained several times varying the set of variables. A training dataset of 1172 patients was evaluated with a 10-stratified-fold cross-validation scheme. The area under the Receiver Operating Characteristic curve (AUC) was the metric for the predictive ability. The results were assessed by only considering the output after applying the model to the test set, which was composed of the remaining 391 patients. RESULTS The AUC score obtained by the dense tissue percentage (0.55) was compared to a machine learning-based classifier results. The classifier, apart from the percentage of dense tissue of both views, firstly included global geometric features such as the distance of dense tissue to the pectoral muscle, dense tissue eccentricity or the dense tissue perimeter, obtaining an accuracy of 0.56. By the inclusion of a global feature based on local histograms of oriented gradients, the accuracy of the classifier was significantly improved (0.61). The number of well-classified patients was improved up to 236 when it was 208. CONCLUSION Relative geometric features of dense tissue over the breast and histograms of standardized local texture features based on sliding windows scanning the whole breast improve risk prediction beyond the dense tissue percentage adjusted by geometrical variables. Other classifiers could improve the results obtained by the conventional Random Forests used in this study.
Collapse
Affiliation(s)
| | - Francois Signol
- Institute of Computer Technology, Universitat Politècnica de València, Camino de Vera, s/n, València, 46022 Spain.
| | - Juan-Carlos Pérez-Cortés
- Institute of Computer Technology, Universitat Politècnica de València, Camino de Vera, s/n, València, 46022 Spain.
| | - Marina Pollán
- National Center for Epidemiology, Carlos III Institute of Health, Monforte de lemos, 5, Madrid, 28029 Spain; Consortium for Biomedical Research in Epidemiology and Public Health (CIBER en Epidemiología y Salud Pública - CIBERESP), Carlos III Institute of Health, Monforte de Lemos, 5, Madrid, 28029 Spain.
| | - Beatriz Pérez-Gómez
- National Center for Epidemiology, Carlos III Institute of Health, Monforte de lemos, 5, Madrid, 28029 Spain; Consortium for Biomedical Research in Epidemiology and Public Health (CIBER en Epidemiología y Salud Pública - CIBERESP), Carlos III Institute of Health, Monforte de Lemos, 5, Madrid, 28029 Spain.
| | - Dolores Salas-Trejo
- Valencian Breast Cancer Screening Program, General Directorate of Public Health, València, Spain; Centro Superior de Investigación en Salud Pública CSISP, FISABIO, València, Spain.
| | - María Casals
- Valencian Breast Cancer Screening Program, General Directorate of Public Health, València, Spain; Centro Superior de Investigación en Salud Pública CSISP, FISABIO, València, Spain.
| | - Inmaculada Martínez
- Valencian Breast Cancer Screening Program, General Directorate of Public Health, València, Spain; Centro Superior de Investigación en Salud Pública CSISP, FISABIO, València, Spain.
| | - Rafael LLobet
- Institute of Computer Technology, Universitat Politècnica de València, Camino de Vera, s/n, València, 46022 Spain.
| |
Collapse
|
12
|
Mohanty F, Rup S, Dash B, Majhi B, Swamy MNS. Digital mammogram classification using 2D-BDWT and GLCM features with FOA-based feature selection approach. Neural Comput Appl 2019. [DOI: 10.1007/s00521-019-04186-w] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
13
|
A computer-aided diagnosis system using Tchebichef features and improved grey wolf optimized extreme learning machine. APPL INTELL 2018. [DOI: 10.1007/s10489-018-1294-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|