1
|
Dou P, Li X, Jin H, Ma B, Jin M, Xu Y. Research trends of biomechanics in scoliosis from 1999 to 2023: a bibliometric analysis. Spine Deform 2024:10.1007/s43390-024-01000-z. [PMID: 39499450 DOI: 10.1007/s43390-024-01000-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2024] [Accepted: 10/19/2024] [Indexed: 11/07/2024]
Abstract
OBJECTIVE Despite the abundance of research on the biomechanics of scoliosis, there is a lack of a comprehensive bibliometric analysis. This study utilizes bibliometric methods to elucidate the research trends and hotspots within this domain. METHODS The data for this study were obtained from the Web of Science Core Collection and then analyzed using the open-source Bibliometrix R package and Citespace. RESULTS The analysis encompassed 410 publications published from 1999 to 2023. There is a sustained increase in the number of publications within the field. Utilizing citation analysis and keyword analysis, the study identified key research focuses. Burst keyword analysis identified 19 keywords. CONCLUSIONS The period from 1999 to 2023 has witnessed significant research attention on the biomechanics of scoliosis. The demographic shift towards an aging population has recently increased interest in ASD. Proximal biomechanical changes and transitional zones in PJK and PJF are hotspots in research, offering emerging scholars in this discipline valuable opportunities for exploration.
Collapse
Affiliation(s)
- Peng Dou
- The Department of Rehabilitation Medicine, The Seventh Affiliated Hospital, Sun Yat-Sen University, Shenzhen, China
| | - Xuan Li
- The Department of Rehabilitation Medicine, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, China
| | - Haobo Jin
- Sun Yat-Sen University, Shenzhen, China
| | - Boning Ma
- Sun Yat-Sen University, Shenzhen, China
| | - Ming Jin
- Sun Yat-Sen University, Shenzhen, China
| | - Yi Xu
- The Department of Rehabilitation Medicine, The Seventh Affiliated Hospital, Sun Yat-Sen University, Shenzhen, China.
| |
Collapse
|
2
|
Comte N, Pujades S, Courvoisier A, Daniel O, Franco JS, Faure F, Boyer E. Multi-Modal Data Correspondence for the 4D Analysis of the Spine with Adolescent Idiopathic Scoliosis. Bioengineering (Basel) 2023; 10:874. [PMID: 37508901 PMCID: PMC10376049 DOI: 10.3390/bioengineering10070874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Revised: 07/11/2023] [Accepted: 07/19/2023] [Indexed: 07/30/2023] Open
Abstract
Adolescent idiopathic scoliosis is a three-dimensional spinal deformity that evolves during adolescence. Combined with static 3D X-ray acquisitions, novel approaches using motion capture allow for the analysis of the patient dynamics. However, as of today, they cannot provide an internal analysis of the spine in motion. In this study, we investigated the use of personalized kinematic avatars, created with observations of the outer (skin) and internal shape (3D spine) to infer the actual anatomic dynamics of the spine when driven by motion capture markers. Towards that end, we propose an approach to create a subject-specific digital twin from multi-modal data, namely, a surface scan of the back of the patient and a reconstruction of the 3D spine (EOS). We use radio-opaque markers to register the inner and outer observations. With respect to the previous work, our method does not rely on a precise palpation for the placement of the markers. We present the preliminary results on two cases, for which we acquired a second biplanar X-ray in a bending position. Our model can infer the spine motion from mocap markers with an accuracy below 1 cm on each anatomical axis and near 5 degrees in orientations.
Collapse
Affiliation(s)
- Nicolas Comte
- Anatoscope, 38330 Montbonnot-Saint-Martin, France
- Inria, Université Grenoble Alpes, CNRS, Grenoble INP, LJK, 38000 Grenoble, France
| | - Sergi Pujades
- Inria, Université Grenoble Alpes, CNRS, Grenoble INP, LJK, 38000 Grenoble, France
| | - Aurélien Courvoisier
- TIMC-IMAG, University Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup, Grenoble INP, CHU Grenoble Alpes, 38000 Grenoble, France
- Grenoble Alps Scoliosis and Spine Center, Grenoble Alps University Hospital, Bvd de la Chantourne, CEDEX 09, 38043 Grenoble, France
| | - Olivier Daniel
- TIMC-IMAG, University Grenoble Alpes, CNRS, UMR 5525, VetAgro Sup, Grenoble INP, CHU Grenoble Alpes, 38000 Grenoble, France
- Grenoble Alps Scoliosis and Spine Center, Grenoble Alps University Hospital, Bvd de la Chantourne, CEDEX 09, 38043 Grenoble, France
| | | | | | - Edmond Boyer
- Inria, Université Grenoble Alpes, CNRS, Grenoble INP, LJK, 38000 Grenoble, France
| |
Collapse
|
3
|
Ballit A, Hivert M, Rubod C, Dao TT. Fast soft-tissue deformations coupled with mixed reality toward the next-generation childbirth training simulator. Med Biol Eng Comput 2023:10.1007/s11517-023-02864-5. [PMID: 37382859 DOI: 10.1007/s11517-023-02864-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Accepted: 06/07/2023] [Indexed: 06/30/2023]
Abstract
High-quality gynecologist and midwife training is particularly relevant to limit medical complications and reduce maternal and fetal morbimortalities. Physical and virtual training simulators have been developed. However, physical simulators offer a simplified model and limited visualization of the childbirth process, while virtual simulators still lack a realistic interactive system and are generally limited to imposed predefined gestures. Objective performance assessment based on the simulation numerical outcomes is still not at hand. In the present work, we developed a virtual childbirth simulator based on the Mixed-Reality (MR) technology coupled with HyperMSM (Hyperelastic Mass-Spring Model) formulation for real-time soft-tissue deformations, providing intuitive user interaction with the virtual physical model and a quantitative assessment to enhance the trainee's gestures. Microsoft HoloLens 2 was used and the MR simulator was developed including a complete holographic obstetric model. A maternal pelvis system model of a pregnant woman (including the pelvis bone, the pelvic floor muscles, the birth canal, the uterus, and the fetus) was generated, and HyperMSM formulation was applied to simulate the soft tissue deformations. To induce realistic reactions to free gestures, the virtual replicas of the user's detected hands were introduced into the physical simulation and were associated with a contact model between the hands and the HyperMSM models. The gesture of pulling any part of the virtual models with two hands was also implemented. Two labor scenarios were implemented within the MR childbirth simulator: physiological labor and forceps-assisted labor. A scoring system for the performance assessment was included based on real-time biofeedback. As results, our developed MR simulation application was developed in real-time with a refresh rate of 30-50 FPS on the HoloLens device. HyperMSM model was validated using FE outcomes: high correlation coefficients of [0.97-0.99] and weighted root mean square relative errors of 9.8% and 8.3% were obtained for the soft tissue displacement and energy density respectively. Experimental tests showed that the implemented free-user interaction system allows to apply the correct maneuvers (in particular the "Viennese" maneuvers) during the labor process, and is capable to induce a truthful reaction of the model. Obtained results confirm also the possibility of using our simulation's outcomes to objectively evaluate the trainee's performance with a reduction of 39% for the perineal strain energy density and 5.6 mm for the vertical vaginal diameter when the "Viennese" technique is applied. This present study provides, for the first time, an interactive childbirth simulator with an MR immersive experience with direct free-hand interaction, real-time soft-tissue deformation feedback, and an objective performance assessment based on numerical outcomes. This offers a new perspective for enhancing next-generation training-based obstetric teaching. The used models of the maternal pelvic system and the fetus will be enhanced, and more delivery scenarios (e.g. instrumental delivery, breech delivery, shoulder dystocia) will be designed and integrated. The third stage of labor will be also investigated to include the delivery of the placenta, and the clamping and cutting of the umbilical cord.
Collapse
Affiliation(s)
- Abbass Ballit
- Univ. Lille, CNRS, Centrale Lille, UMR 9013-LaMcube-Laboratoire de Mécanique, Multiphysique, Multiéchelle, Lille, F-59000, France
| | - Mathieu Hivert
- Université Lille Nord de France, Faculté de Médecine, F-59000, Lille, France
- CHU Lille, Service de Chirurgie Gynécologique, F-59000, Lille, France
| | - Chrystèle Rubod
- Univ. Lille, CNRS, Centrale Lille, UMR 9013-LaMcube-Laboratoire de Mécanique, Multiphysique, Multiéchelle, Lille, F-59000, France
- Université Lille Nord de France, Faculté de Médecine, F-59000, Lille, France
- CHU Lille, Service de Chirurgie Gynécologique, F-59000, Lille, France
| | - Tien-Tuan Dao
- Univ. Lille, CNRS, Centrale Lille, UMR 9013-LaMcube-Laboratoire de Mécanique, Multiphysique, Multiéchelle, Lille, F-59000, France.
| |
Collapse
|
4
|
Kardash K, Koutras C, Otaduy MA. Design of personalized scoliosis braces based on differentiable biomechanics—Synthetic study. Front Bioeng Biotechnol 2022; 10:1014365. [DOI: 10.3389/fbioe.2022.1014365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Accepted: 10/24/2022] [Indexed: 11/12/2022] Open
Abstract
This work describes a computational methodology for the design of braces for adolescent idiopathic scoliosis. The proposed methodology relies on a personalized simulation model of the patient’s trunk, and automatically searches for the brace geometry that optimizes the trade-off between clinical improvement and patient comfort. To do this, we introduce a formulation of differentiable biomechanics of the patient’s trunk, the brace, and their interaction. We design a simulation model that is differentiable with respect to both the deformation state and the brace design parameters, and we show how this differentiable model is used for the efficient update of brace design parameters within a numerical optimization algorithm. To evaluate the proposed methodology, we have obtained trunk models with personalized geometry for five patients of adolescent idiopathic scoliosis, and we have designed Boston-type braces. In a simulation setting, the designed braces improve clinical metrics by 45% on average, under acceptable comfort conditions. In the future, the methodology can be extended beyond synthetic validation, and tested with physical braces on the actual patients.
Collapse
|
5
|
Koutras C, Shayestehpour H, Pérez J, Wong C, Rasmussen J, Tournier M, Nesme M, Otaduy MA. Biomechanical Morphing for Personalized Fitting of Scoliotic Torso Skeleton Models. Front Bioeng Biotechnol 2022; 10:945461. [PMID: 35928945 PMCID: PMC9343806 DOI: 10.3389/fbioe.2022.945461] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 06/23/2022] [Indexed: 11/22/2022] Open
Abstract
The use of patient-specific biomechanical models offers many opportunities in the treatment of adolescent idiopathic scoliosis, such as the design of personalized braces. The first step in the development of these patient-specific models is to fit the geometry of the torso skeleton to the patient’s anatomy. However, existing methods rely on high-quality imaging data. The exposure to radiation of these methods limits their applicability for regular monitoring of patients. We present a method to fit personalized models of the torso skeleton that takes as input biplanar low-dose radiographs. The method morphs a template to fit annotated points on visible portions of the spine, and it relies on a default biomechanical model of the torso for regularization and robust fitting of hardly visible parts of the torso skeleton, such as the rib cage. The proposed method provides an accurate and robust solution to obtain personalized models of the torso skeleton, which can be adopted as part of regular management of scoliosis patients. We have evaluated the method on ten young patients who participated in our study. We have analyzed and compared clinical metrics on the spine and the full torso skeleton, and we have found that the accuracy of the method is at least comparable to other methods that require more demanding imaging methods, while it offers superior robustness to artifacts such as interpenetration of ribs. Normal-dose X-rays were available for one of the patients, and for the other nine we acquired low-dose X-rays, allowing us to validate that the accuracy of the method persisted under less invasive imaging modalities.
Collapse
Affiliation(s)
- Christos Koutras
- Department of Computer Science, Universidad Rey Juan Carlos, Madrid, Spain
- *Correspondence: Christos Koutras,
| | - Hamed Shayestehpour
- Department of Materials and Production, Aalborg University, Aalborg, Denmark
| | - Jesús Pérez
- Department of Computer Science, Universidad Rey Juan Carlos, Madrid, Spain
| | - Christian Wong
- Orthopedics Department, University Hospital of Hvidovre, Hvidovre, Denmark
| | - John Rasmussen
- Department of Materials and Production, Aalborg University, Aalborg, Denmark
| | | | | | - Miguel A. Otaduy
- Department of Computer Science, Universidad Rey Juan Carlos, Madrid, Spain
| |
Collapse
|
6
|
Ballit A, Dao TT. HyperMSM: A new MSM variant for efficient simulation of dynamic soft-tissue deformations. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 216:106659. [PMID: 35108626 DOI: 10.1016/j.cmpb.2022.106659] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Revised: 01/11/2022] [Accepted: 01/22/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Fast, accurate, and stable simulation of soft tissue deformation is a challenging task. Mass-Spring Model (MSM) is one of the popular methods used for this purpose for its simple implementation and potential to provide fast dynamic simulations. However, accurately simulating a non-linear material within the mass-spring framework is still challenging. The objective of the present study is to develop and evaluate a new efficient hyperelastic Mass-Spring Model formulation to simulate the Neo-Hookean deformable material, called HyperMSM. METHODS Our novel HyperMSM formulation is applicable for both tetrahedral and hexahedral mesh configurations and is compatible with the original projective dynamics solver. In particular, the proposed MSM variant includes springs with variable rest-lengths and a volume conservation constraint. Two applications (transtibial residual limb and the skeletal muscle) were conducted. RESULTS Compared to finite element simulations, obtained results show RMSE ranges of [2.8%-5.2%] and [0.46%-5.4%] for stress-strain and volumetric responses respectively for strains ranging from -50% to +100%. The displacement error range in our transtibial residual limb simulation is around [0.01mm-0.7 mm]. The RMSE range of relative nodal displacements for the skeletal psoas muscle model is [0.4%-1.7%]. CONCLUSIONS Our novel HyperMSM formulation allows hyperelastic behavior of soft tissues to be described accurately and efficiently within the mass-spring framework. As perspectives, our formulation will be enhanced with electric behavior toward a multi-physical soft tissue mass-spring modeling framework. Then, the coupling with an augmented reality environment will be performed.
Collapse
Affiliation(s)
- Abbass Ballit
- Univ. Lille, CNRS, Centrale Lille, UMR 9013 - LaMcube - Laboratoire de Mécanique, Multiphysique, Multiéchelle, 59655 Villeneuve d'Ascq Cedex, F-59000, Lille, France.
| | - Tien-Tuan Dao
- Univ. Lille, CNRS, Centrale Lille, UMR 9013 - LaMcube - Laboratoire de Mécanique, Multiphysique, Multiéchelle, 59655 Villeneuve d'Ascq Cedex, F-59000, Lille, France.
| |
Collapse
|
7
|
Al-Baghdadi M, Jweeg MJ, Al-Waily M. Analytical and Numerical Investigations of Mechanical Vibration in the Vertical Direction of a Human Body in a Driving Vehicle using Biomechanical Vibration Model. PERTANIKA JOURNAL OF SCIENCE AND TECHNOLOGY 2021. [DOI: 10.47836/pjst.29.4.30] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
The main reason that affects the discomfort in a driving vehicle is the vibration response. The human body vibration leads to many malfunctions in both comfort and performance in human health. As a result, the human body’s simulation in sitting posture in the driving vehicle has a strategic relationship for all Tires and vehicles manufacturers. The digital process simulation of the human body seat vehicle vibration shows two significant advantages. The first advantage is the prevention of the high-cost modifications in the construction stage of the vehicle, while the second one describes the stability test during the undesirable vibrations. This study modelled the human body’s dynamic characterisations, natural frequency, and mechanical response when seated in the driving vehicle with vibration transmissibility in the vertical direction have been using the biomechanical vibration model. The vertical vibrations and the transmissibility of the human body dynamic response are presented in detail. Exciting results have been obtained, and they are significant for human health, which relates to sitting posture in the driving vehicle. It can assist in understanding the influences of low-frequency vibration on human health, comfort, and performance, and therefore it could be applied for ride comfort evaluation. An analytical solution to derive the general equations of motion for the human system was developed. Then, using the vibration analysis technique and the corresponding equations, the accurate dynamic response of the selected mode is identified. Furthermore, the mathematical modelling for free vibration using the finite element analysis has been performed to determine the appropriate values and set its description. Then, the comparison results of the two techniques have been carried out.
Collapse
|