Voltammetric quantitation of nitazoxanide by glassy carbon electrode.
J Pharm Anal 2013;
3:452-455. [PMID:
29403854 PMCID:
PMC5761018 DOI:
10.1016/j.jpha.2013.07.005]
[Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2012] [Accepted: 07/30/2013] [Indexed: 11/20/2022] Open
Abstract
The present study reports voltammetric reduction of nitazoxanide in Britton–Robinson (B–R) buffer by cyclic and square-wave voltammetry at glassy carbon electrode. A versatile fully validated voltammetric method for quantitative determination of nitazoxanide in pharmaceutical formulation has been proposed. A squrewave peak current was linear over the nitazoxanide concentration in the range of 20–140 µg/mL. The limit of detection (LOD) and limit of quantification (LOQ) was calculated to be 5.23 μg/mL and 17.45 μg/mL, respectively.