1
|
Pal A, Gope A, Sengupta A. Drying of bio-colloidal sessile droplets: Advances, applications, and perspectives. Adv Colloid Interface Sci 2023; 314:102870. [PMID: 37002959 DOI: 10.1016/j.cis.2023.102870] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2022] [Revised: 03/03/2023] [Accepted: 03/03/2023] [Indexed: 04/03/2023]
Abstract
Drying of biologically-relevant sessile droplets, including passive systems such as DNA, proteins, plasma, and blood, as well as active microbial systems comprising bacterial and algal dispersions, has garnered considerable attention over the last decades. Distinct morphological patterns emerge when bio-colloids undergo evaporative drying, with significant potential in a wide range of biomedical applications, spanning bio-sensing, medical diagnostics, drug delivery, and antimicrobial resistance. Consequently, the prospects of novel and thrifty bio-medical toolkits based on drying bio-colloids have driven tremendous progress in the science of morphological patterns and advanced quantitative image-based analysis. This review presents a comprehensive overview of bio-colloidal droplets drying on solid substrates, focusing on the experimental progress during the last ten years. We provide a summary of the physical and material properties of relevant bio-colloids and link their native composition (constituent particles, solvent, and concentrations) to the patterns emerging due to drying. We specifically examined the drying patterns generated by passive bio-colloids (e.g., DNA, globular, fibrous, composite proteins, plasma, serum, blood, urine, tears, and saliva). This article highlights how the emerging morphological patterns are influenced by the nature of the biological entities and the solvent, micro- and global environmental conditions (temperature and relative humidity), and substrate attributes like wettability. Crucially, correlations between emergent patterns and the initial droplet compositions enable the detection of potential clinical abnormalities when compared with the patterns of drying droplets of healthy control samples, offering a blueprint for the diagnosis of the type and stage of a specific disease (or disorder). Recent experimental investigations of pattern formation in the bio-mimetic and salivary drying droplets in the context of COVID-19 are also presented. We further summarized the role of biologically active agents in the drying process, including bacteria, algae, spermatozoa, and nematodes, and discussed the coupling between self-propulsion and hydrodynamics during the drying process. We wrap up the review by highlighting the role of cross-scale in situ experimental techniques for quantifying sub-micron to micro-scale features and the critical role of cross-disciplinary approaches (e.g., experimental and image processing techniques with machine learning algorithms) to quantify and predict the drying-induced features. We conclude the review with a perspective on the next generation of research and applications based on drying droplets, ultimately enabling innovative solutions and quantitative tools to investigate this exciting interface of physics, biology, data sciences, and machine learning.
Collapse
Affiliation(s)
- Anusuya Pal
- University of Warwick, Department of Physics, Coventry CV47AL, West Midlands, UK; Worcester Polytechnic Institute, Department of Physics, Worcester 01609, MA, USA.
| | - Amalesh Gope
- Tezpur University, Department of Linguistics and Language Technology, Tezpur 784028, Assam, India
| | - Anupam Sengupta
- University of Luxembourg, Physics of Living Matter, Department of Physics and Materials Science, Luxembourg L-1511, Luxembourg
| |
Collapse
|
2
|
Hierarchical Exploration of Drying Patterns Formed in Drops Containing Lysozyme, PBS, and Liquid Crystals. Processes (Basel) 2022. [DOI: 10.3390/pr10050955] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
Biological systems, by nature, are highly complex. These systems exhibit diverse hierarchical spatial and temporal features when driven far from equilibrium. The generated features are susceptible to the initial conditions that largely depend on vast parameter space. Extracting information on their properties and behavior thus becomes far too complex. This work seeks to examine the drying kinetics of the drops containing a globular protein (xlysozyme (Lys)), phosphate buffer saline (PBS), and thermotropic liquid crystal (LCs). The drying evolution and the morphological crack patterns of these drops are examined using high-resolution microscopy, textural image analysis, and statistical methods. This study observes that the textural parameters can identify the (i) phase separation of the salts present in the PBS and (ii) the LCs’ birefringence during the drying evolution. This birefringence activities of the LCs slow down when the initial PBS concentration is increased from 0.25 to 1× despite using a fixed volume of LCs. To comprehend such a surprising effect, the combinations of (i) Lys+PBS and (ii) PBS+LCs are thoroughly examined. A phase diagram is established as a function of initial concentrations of Lys and PBS. The scanning electron microscopic images of Lys+PBS reveal that the tuning between lysozyme and salt concentrations in PBS plays a significant role in determining the morphological patterns. The Lys drops with and without LCs exhibit two distinct regions: the peripheral ring (“coffee-ring”) and the central ones. This phase-separated ring formation indicates that the film containing Lys and salts might have formed on top of these LCs in the central region, which reduces the optical response (birefringence) of LCs. A physical mechanism is proposed in this paper to anticipate the redistributions of LCs in a multi-component system such as Lys+PBS+LCs.
Collapse
|
3
|
Carreón YJP, Gómez-López ML, Díaz-Hernández O, Vazquez-Vergara P, Moctezuma RE, Saniger JM, González-Gutiérrez J. Patterns in Dried Droplets to Detect Unfolded BSA. SENSORS (BASEL, SWITZERLAND) 2022; 22:1156. [PMID: 35161907 PMCID: PMC8839909 DOI: 10.3390/s22031156] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 01/28/2022] [Accepted: 01/30/2022] [Indexed: 12/12/2022]
Abstract
The morphological analysis of patterns in dried droplets has allowed the generation of efficient techniques for the detection of molecules of medical interest. However, the effectiveness of this method to reveal the coexistence of macromolecules of the same species, but different conformational states, is still unknown. To address this problem, we present an experimental study on pattern formation in dried droplets of bovine serum albumin (BSA), in folded and unfolded conformational states, in saline solution (NaCl). Folded proteins produce a well-defined coffee ring and crystal patterns all over the dry droplet. Depending on the NaCl concentration, the crystals can be small, large, elongated, entangled, or dense. Optical microscopy reveals that the relative concentration of unfolded proteins determines the morphological characteristics of deposits. At a low relative concentration of unfolded proteins (above 2%), small amorphous aggregates emerge in the deposits, while at high concentrations (above 16%), the "eye-like pattern", a large aggregate surrounded by a uniform coating, is produced. The radial intensity profile, the mean pixel intensity, and the entropy make it possible to characterize the patterns in dried droplets. We prove that it is possible to achieve 100% accuracy in identifying 4% of unfolded BSA contained in a protein solution.
Collapse
Affiliation(s)
- Yojana J. P. Carreón
- Instituto de Ciencias Aplicadas y Tecnología, Universidad Nacional Autónoma de México, Av. Universidad 3000, Coyoacan, Mexico City 04510, Mexico;
| | - Mary Luz Gómez-López
- Facultad de Ciencias en Física y Matemáticas, Universidad Autónoma de Chiapas, Tuxtla Gutiérrez 29050, Mexico; (M.L.G.-L.); (O.D.-H.)
| | - Orlando Díaz-Hernández
- Facultad de Ciencias en Física y Matemáticas, Universidad Autónoma de Chiapas, Tuxtla Gutiérrez 29050, Mexico; (M.L.G.-L.); (O.D.-H.)
| | - Pamela Vazquez-Vergara
- Departament de Física de la Materia Condensada, Universitat de Barcelona, Av. Diagonal 645, E08028 Barcelona, Spain;
| | | | - José M. Saniger
- Instituto de Ciencias Aplicadas y Tecnología, Universidad Nacional Autónoma de México, Av. Universidad 3000, Coyoacan, Mexico City 04510, Mexico;
| | - Jorge González-Gutiérrez
- Facultad de Ciencias en Física y Matemáticas, Universidad Autónoma de Chiapas, Tuxtla Gutiérrez 29050, Mexico; (M.L.G.-L.); (O.D.-H.)
| |
Collapse
|
4
|
Evaporation heat transfer enhancement by a laser-textured heterogeneous surface. Colloids Surf A Physicochem Eng Asp 2021. [DOI: 10.1016/j.colsurfa.2021.127359] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
5
|
Kim S, Kim WY, Nam SH, Shin S, Choi SH, Kim DH, Lee H, Choi HJ, Lee E, Park JH, Jo I, Fang NX, Cho YT. Microstructured Surfaces for Reducing Chances of Fomite Transmission via Virus-Containing Respiratory Droplets. ACS NANO 2021; 15:14049-14060. [PMID: 34339604 DOI: 10.1021/acsnano.1c01636] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Evaporation-induced particle aggregation in drying droplets is of significant importance in the prevention of pathogen transfer due to the possibility of indirect fomite transmission of the infectious virus particles. In this study, particle aggregation was directionally controlled using contact line dynamics (pinned or slipping) and geometrical gradients on microstructured surfaces by the systematic investigation of the evaporation process on sessile droplets and sprayed microdroplets laden with virus-simulant nanoparticles. Using this mechanism, we designed robust particle capture surfaces by significantly inhibiting the contact transfer of particles from fomite surfaces. For the proof-of-concept, interconnected hexagonal and inverted pyramidal microwall were fabricated using ultraviolet-based nanoimprint lithography, which is considered to be a promising scalable manufacturing process. We demonstrated the potentials of an engineered microcavity surface to limit the contact transfer of particle aggregates deposited with the evaporation of microdroplets by 93% for hexagonal microwall and by 96% for inverted pyramidal microwall. The particle capture potential of the interconnected microstructures was also investigated using biological particles, including adenoviruses and lung-derived extracellular vesicles. The findings indicate that the proposed microstructured surfaces can reduce the indirect fomite transmission of highly infectious agents, including norovirus, rotavirus, or SARS-CoV-2, via respiratory droplets.
Collapse
Affiliation(s)
- Seok Kim
- Department of Mechanical Engineering, Changwon National University, Changwon 51140, South Korea
- Department of Smart Manufacturing Engineering, Changwon National University, Changwon 51140, South Korea
| | - Woo Young Kim
- Department of Smart Manufacturing Engineering, Changwon National University, Changwon 51140, South Korea
| | - Sang-Hoon Nam
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Seunghang Shin
- Department of Smart Manufacturing Engineering, Changwon National University, Changwon 51140, South Korea
| | - Su Hyun Choi
- Department of Mechanical Engineering, Changwon National University, Changwon 51140, South Korea
| | - Do Hyeog Kim
- Department of Mechanical Engineering, Changwon National University, Changwon 51140, South Korea
| | - Heedoo Lee
- Department of Biology and Chemistry, Changwon National University, Changwon 51140, South Korea
| | - Hyeok Jae Choi
- Department of Biology and Chemistry, Changwon National University, Changwon 51140, South Korea
| | - Eungman Lee
- Department of Radiation Oncology, College of Medicine, Ewha Womans University, Seoul 07804, South Korea
| | - Jung-Hyun Park
- Department of Molecular Medicine, College of Medicine, Ewha Womans University, Seoul 07804, South Korea
| | - Inho Jo
- Department of Molecular Medicine, College of Medicine, Ewha Womans University, Seoul 07804, South Korea
- Ewha Education & Research Center for Infection, Ewha Womans University Medical Center, Seoul 07804, South Korea
| | - Nicholas X Fang
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Young Tae Cho
- Department of Mechanical Engineering, Changwon National University, Changwon 51140, South Korea
- Department of Smart Manufacturing Engineering, Changwon National University, Changwon 51140, South Korea
| |
Collapse
|
6
|
Carreón YJP, Díaz-Hernández O, Escalera Santos GJ, Cipriano-Urbano I, Solorio-Ordaz FJ, González-Gutiérrez J, Zenit R. Texture Analysis of Dried Droplets for the Quality Control of Medicines. SENSORS (BASEL, SWITZERLAND) 2021; 21:4048. [PMID: 34208420 PMCID: PMC8231125 DOI: 10.3390/s21124048] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Revised: 06/02/2021] [Accepted: 06/08/2021] [Indexed: 01/31/2023]
Abstract
The quality control of medicines guarantees the effectiveness of treatments for diseases. We explore the use of texture analysis of patterns in dried droplets as a tool to readily detect both impurities and changes in drug concentration. Four types of medicines associated with different routes of administration were analyzed: Methotrexate, Ciprofloxacin, Clonazepam, and Budesonide. We use NaCl and a hot substrate at 63 ∘C to promote aggregate formation and to reduce droplet drying time. Depending on the medicine, optical microscopy reveals different complex aggregates such as circular to oval splatters, fern-like islands, crown shapes, crown needle-like and bump-like patterns as well as dendritic branched and star-like crystals. We use some physical features of the stains (as the stain diameter and superficial area) and gray level co-occurrence matrix (GLCM) to characterize patterns of dried droplets. Finally, we show that structural analysis of stains can achieve 95% accuracy in identifying medicines with 30% water dilution, while it achieves 99% accuracy in detecting drugs with 10% other substances.
Collapse
Affiliation(s)
- Yojana J. P. Carreón
- Facultad de Ciencias en Física y Matemáticas, Universidad Autónoma de Chiapas, Tuxtla Gutiérrez, Chiapas 29050, Mexico; (Y.J.P.C.); (O.D.-H.); (G.J.E.S.)
- Instituto de Ciencias Aplicadas y Tecnología, Universidad Nacional Autónoma de México, Avenida Universidad 3000, México D.F. 04510, Mexico
| | - Orlando Díaz-Hernández
- Facultad de Ciencias en Física y Matemáticas, Universidad Autónoma de Chiapas, Tuxtla Gutiérrez, Chiapas 29050, Mexico; (Y.J.P.C.); (O.D.-H.); (G.J.E.S.)
| | - Gerardo J. Escalera Santos
- Facultad de Ciencias en Física y Matemáticas, Universidad Autónoma de Chiapas, Tuxtla Gutiérrez, Chiapas 29050, Mexico; (Y.J.P.C.); (O.D.-H.); (G.J.E.S.)
| | - Ivan Cipriano-Urbano
- Escuela de Medicina, Universidad Autónoma de Coahuila, Piedras Negras, Coahuila 26090, Mexico;
| | - Francisco J. Solorio-Ordaz
- Departamento de Termofluidos, Facultad de Ingeniería, Universidad Nacional Autónoma de México, Avenida Universidad 3000, México D.F. 04510, Mexico;
| | - Jorge González-Gutiérrez
- Facultad de Ciencias en Física y Matemáticas, Universidad Autónoma de Chiapas, Tuxtla Gutiérrez, Chiapas 29050, Mexico; (Y.J.P.C.); (O.D.-H.); (G.J.E.S.)
- Departamento de Termofluidos, Facultad de Ingeniería, Universidad Nacional Autónoma de México, Avenida Universidad 3000, México D.F. 04510, Mexico;
| | - Roberto Zenit
- Center for Fluid Mechanics, School of Engineering, Brown University, Providence, RI 02912, USA
| |
Collapse
|
7
|
Carreón YJP, Ríos-Ramírez M, Vázquez-Vergara P, Salinas-Almaguer S, Cipriano-Urbano I, Briones-Aranda A, Díaz-Hernández O, Escalera Santos GJ, González-Gutiérrez J. Effects of substrate temperature on patterns produced by dried droplets of proteins. Colloids Surf B Biointerfaces 2021; 203:111763. [PMID: 33865091 DOI: 10.1016/j.colsurfb.2021.111763] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2020] [Revised: 03/16/2021] [Accepted: 04/08/2021] [Indexed: 02/07/2023]
Abstract
Rapid diagnosis provides better clinical management of patients, helps control possible outbreaks, and increases survival. The study of deposits produced by the evaporation of droplets is a useful tool in the diagnosis of some health problems. With the aim to improve diagnostic time in clinical practice where we use the evaporation of droplets, we explored the effects of substrate temperature on pattern formation of dried droplets in globular protein solutions. Three deposit groups were observed: "functional" patterns (from 25 to 37 ∘C), "transition" patterns (from 44 to 50 ∘C), and "eye" patterns (from 58 to 63 ∘C). The dried droplets of the first two groups show a ring structure ("coffee-ring") that confines a great diversity of aggregates such as needle-like structures, tiny blade-shape crystals, highly symmetrical crystallization patterns, and amorphous salt aggregates. In contrast, the "eye" patterns are deposits with a large inner aggregate surrounded by a coffee ring, and they can appear from the evaporation of droplets in protein binary mixtures and blood serum. Interestingly, the unfolding proteins correlates with the formation of "eye" patterns. We measured stain diameter, "coffee-ring" thickness, radial density profile, and entropy computed by GLCM-statistics to quantify the structural differences among deposit groups. We found that "functional" patterns are structurally indistinguishable among them, but they are clearly different from elements of the other deposit groups. An exponential decay function describes pattern formation time as a function of substrate temperature, which is independent from protein concentration. Patterns formation at 32 ∘C takes place up to 63% less time and preserves the structural characteristics of dried droplets in proteins formed at room temperature. Therefore, we argue that droplet evaporation at this substrate temperature could be an excellent candidate to make a more efficient diagnosis based on droplet evaporation of biofluids.
Collapse
Affiliation(s)
- Yojana J P Carreón
- Instituto de Ciencias Aplicadas y Tecnología, Universidad Nacional Autónoma de México, Av. Universidad 3000, Coyoacán, 04510 CDMX, Mexico
| | | | - Pamela Vázquez-Vergara
- Departament de Física de la Materia Condensada, Universitat de Barcelona, Av. Diagonal 645, E08028 Barcelona, Spain
| | | | - I Cipriano-Urbano
- Escuela de Medicina, Universidad Autónoma de Coahuila, 26090 Piedras Negras, Coahuila, Mexico
| | - Alfredo Briones-Aranda
- Facultad de Medicina Humana, Universidad Autónoma de Chiapas, Tuxtla Gutiérrez, Chiapas, Mexico
| | - O Díaz-Hernández
- Facultad de Ciencias en Física y Matemáticas, Universidad Autónoma de Chiapas, Tuxtla Gutiérrez, Chiapas, Mexico
| | - Gerardo J Escalera Santos
- Facultad de Ciencias en Física y Matemáticas, Universidad Autónoma de Chiapas, Tuxtla Gutiérrez, Chiapas, Mexico.
| | - Jorge González-Gutiérrez
- Facultad de Ciencias en Física y Matemáticas, Universidad Autónoma de Chiapas, Tuxtla Gutiérrez, Chiapas, Mexico.
| |
Collapse
|
8
|
Jesus CSH, Soares HT, Piedade AP, Cortes L, Serpa C. Using amyloid autofluorescence as a biomarker for lysozyme aggregation inhibition. Analyst 2021; 146:2383-2391. [PMID: 33646214 DOI: 10.1039/d0an02260h] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
The assembly of proteins into amyloidogenic aggregates underlies the onset and symptoms of several pathologies, including Alzheimer's disease, Parkinson's disease and type II diabetes. Among the efforts for fighting these diseases, there is a great demand for developing novel, fast and reliable methods for in vitro screening of new drugs that may suppress or reverse amyloidogenesis. Recent studies unravelled a progressive increase in a blue autofluorescence upon amyloid formation originated from many different proteins, including the peptide amyloid-β, lysozyme or insulin. Herein, we propose a drug screening method using this property, avoiding the use of external probe dyes. We demonstrate that the inhibition of lysozyme amyloid formation by means of two known inhibitors, tartrazine and amaranth, can be monitored based on the autofluorescence of lysozyme amyloid aggregates. Our results show that amyloid luminescence is an intrinsic property that can be potentially applied in a screening assay, allowing the ranking of drug efficiency. The assays demonstrated here are fast to perform and suitable for scaling using microplate assays, configuring a new sensitive and economically feasible method.
Collapse
Affiliation(s)
- Catarina S H Jesus
- University of Coimbra, CQC, Department of Chemistry, 3004-535 Coimbra, Portugal.
| | | | | | | | | |
Collapse
|
9
|
Pal A, Gope A, Iannacchione G. Temperature and Concentration Dependence of Human Whole Blood and Protein Drying Droplets. Biomolecules 2021; 11:231. [PMID: 33562850 PMCID: PMC7915023 DOI: 10.3390/biom11020231] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2020] [Revised: 01/24/2021] [Accepted: 02/01/2021] [Indexed: 12/31/2022] Open
Abstract
The drying of bio-colloidal droplets can be used in many medical and forensic applications. The whole human blood is the most complex bio-colloid system, whereas bovine serum albumin (BSA) is the simplest. This paper focuses on the drying characteristics and the final morphology of these two bio-colloids. The experiments were conducted by varying their initial concentrations, and the solutions were dried under various controlled substrate temperatures using optical and scanning electron microscopy. The droplet parameters (the contact angle, the fluid front, and the first-order image statistics) reveal the drying process's unique features. Interestingly, both BSA and blood drying droplets' contact angle measurements show evidence of a concentration-driven transition as the behavior changes from non-monotonic to monotonic decrease. This result indicates that this transition behavior is not limited to multi-component bio-colloid (blood) only, but may be a phenomenon of a bio-colloidal solution containing a large number of interacting components. The high dilution of blood behaves like the BSA solution. The ring-like deposition, the crack morphology, and the microstructures suggest that the components have enough time to segregate and deposit onto the substrate under ambient conditions. However, there is insufficient time for evaporative-driven segregation to occur at elevated temperatures, as expected.
Collapse
Affiliation(s)
- Anusuya Pal
- Order-Disorder Phenomena Laboratory, Department of Physics, Worcester Polytechnic Institute, Worcester, MA 01609, USA;
| | - Amalesh Gope
- Department of English, Tezpur University, Tezpur 784028, Assam, India;
| | - Germano Iannacchione
- Order-Disorder Phenomena Laboratory, Department of Physics, Worcester Polytechnic Institute, Worcester, MA 01609, USA;
| |
Collapse
|
10
|
Dauer K, Pfeiffer-Marek S, Kamm W, Wagner KG. Microwell Plate-Based Dynamic Light Scattering as a High-Throughput Characterization Tool in Biopharmaceutical Development. Pharmaceutics 2021; 13:pharmaceutics13020172. [PMID: 33514069 PMCID: PMC7911513 DOI: 10.3390/pharmaceutics13020172] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Revised: 01/12/2021] [Accepted: 01/22/2021] [Indexed: 01/03/2023] Open
Abstract
High-throughput light scattering instruments are widely used in screening of biopharmaceutical formulations and can be easily incorporated into processes by utilizing multi-well plate formats. High-throughput plate readers are helpful tools to assess the aggregation tendency and colloidal stability of biological drug candidates based on the diffusion self-interaction parameter (kD). However, plate readers evoke issues about the precision and variability of determined data. In this article, we report about the statistical evaluation of intra- and inter-plate variability (384-well plates) for the kD analysis of protein and peptide solutions. ANOVA revealed no significant differences between the runs. In conclusion, the reliability and precision of kD was dependent on the plate position of the sample replicates and kD value. Positive kD values (57.0 mL/g, coefficients of variation (CV) 8.9%) showed a lower variability compared to negative kD values (−14.8 mL/g, CV 13.4%). The variability of kD was not reduced using more data points (120 vs. 30). A kD analysis exclusively based on center wells showed a lower CV (<2%) compared to edge wells (5–12%) or a combination of edge and center wells (2–5%). We present plate designs for kD analysis within the early formulation development, screening up to 20 formulations consuming less than 50 mg of active pharmaceutical ingredient (API).
Collapse
Affiliation(s)
- Katharina Dauer
- Department of Pharmaceutical Technology and Biopharmaceutics, University of Bonn, 53121 Bonn, Germany;
- Tides Drug Product Pre-Development Sciences, Sanofi-Aventis Deutschland GmbH, Industrial Park Hoechst, 65926 Frankfurt am Main, Germany; (S.P.-M.); (W.K.)
| | - Stefania Pfeiffer-Marek
- Tides Drug Product Pre-Development Sciences, Sanofi-Aventis Deutschland GmbH, Industrial Park Hoechst, 65926 Frankfurt am Main, Germany; (S.P.-M.); (W.K.)
| | - Walter Kamm
- Tides Drug Product Pre-Development Sciences, Sanofi-Aventis Deutschland GmbH, Industrial Park Hoechst, 65926 Frankfurt am Main, Germany; (S.P.-M.); (W.K.)
| | - Karl G. Wagner
- Department of Pharmaceutical Technology and Biopharmaceutics, University of Bonn, 53121 Bonn, Germany;
- Correspondence:
| |
Collapse
|
11
|
Townsend DJ, Middleton DA, Ashton L. Raman Spectroscopy with 2D Perturbation Correlation Moving Windows for the Characterization of Heparin-Amyloid Interactions. Anal Chem 2020; 92:13822-13828. [PMID: 32935978 DOI: 10.1021/acs.analchem.0c02390] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
It has been shown extensively that glycosaminoglycan (GAG)-protein interactions can induce, accelerate, and impede the clearance of amyloid fibrils associated with systemic and localized amyloidosis. Obtaining molecular details of these interactions is fundamental to our understanding of amyloid disease. Consequently, there is a need for analytical approaches that can identify protein conformational transitions and simultaneously characterize heparin interactions. By combining Raman spectroscopy with two-dimensional (2D) perturbation correlation moving window (2DPCMW) analysis, we have successfully identified changes in protein secondary structure during pH- and heparin-induced fibril formation of apolipoprotein A-I (apoA-I) associated with atherosclerosis. Furthermore, from the 2DPCMW, we have identified peak shifts and intensity variations in Raman peaks arising from different heparan sulfate moieties, indicating that protein-heparin interactions vary at different heparin concentrations. Raman spectroscopy thus reveals new mechanistic insights into the role of GAGs during amyloid fibril formation.
Collapse
Affiliation(s)
- David J Townsend
- Department of Chemistry, Lancaster University, Lancaster LA1 4YB, United Kingdom
| | - David A Middleton
- Department of Chemistry, Lancaster University, Lancaster LA1 4YB, United Kingdom
| | - Lorna Ashton
- Department of Chemistry, Lancaster University, Lancaster LA1 4YB, United Kingdom
| |
Collapse
|
12
|
Pal A, Gope A, Athair AS, Iannacchione GS. A comparative study of the drying evolution and dried morphology of two globular proteins in de-ionized water solutions. RSC Adv 2020; 10:16906-16916. [PMID: 35496925 PMCID: PMC9053175 DOI: 10.1039/d0ra01748e] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2020] [Accepted: 04/15/2020] [Indexed: 01/10/2023] Open
Abstract
Pattern formation in drying protein droplets continues to attract considerable research attention because it can be linked to specific protein-protein interactions. An extensive study of the drying evolution and the final crack patterns is presented, highlighting the concentration dependence (from 1 to 13 wt%) of two globular proteins, lysozyme (Lys) and bovine serum albumin (BSA), in de-ionized water. The drying evolution starts with a constant contact radius mode and shifts to a mixed mode where both fluid front and contact angle changes. The contact angle monotonically decreases, whereas, the fluid front exhibits two regimes: an initial linear regime and a later non-linear regime. Unlike the linear regime, the non-linear regime is faster for Lys droplets. This results in the formation of a "mound"-like structure in the central region. A new feature, a "dimple" is observed in this mound which is found to be dependent on the initial concentration. The different crack morphology of BSA and Lys depends strongly on the initial state of the solution and can be interpreted using a simple mechanical model. In fact, when dried under uniform conditions (surface, humidity, temperature, droplet diameter, etc.), the evolution and the final pattern displays as a fingerprint of the initial state.
Collapse
Affiliation(s)
- Anusuya Pal
- Department of Physics, Order-Disorder Phenomena Laboratory, Worcester Polytechnic Institute Worcester MA 01609 USA
| | - Amalesh Gope
- Department of English, Tezpur University Tezpur Assam 784028 India
| | - Ari S Athair
- Department of Physics, Order-Disorder Phenomena Laboratory, Worcester Polytechnic Institute Worcester MA 01609 USA
| | - Germano S Iannacchione
- Department of Physics, Order-Disorder Phenomena Laboratory, Worcester Polytechnic Institute Worcester MA 01609 USA
| |
Collapse
|
13
|
Keya JJ, Kudoh H, Kabir AMR, Inoue D, Miyamoto N, Tani T, Kakugo A, Shikinaka K. Radial alignment of microtubules through tubulin polymerization in an evaporating droplet. PLoS One 2020; 15:e0231352. [PMID: 32275729 PMCID: PMC7147791 DOI: 10.1371/journal.pone.0231352] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Accepted: 03/21/2020] [Indexed: 01/08/2023] Open
Abstract
We report the formation of spherulites from droplets of highly concentrated tubulin solution via nucleation and subsequent polymerization to microtubules (MTs) under water evaporation by heating. Radial alignment of MTs in the spherulites was confirmed by the optical properties of the spherulites observed using polarized optical microscopy and fluorescence microscopy. Temperature and concentration of tubulins were found as important parameters to control the spherulite pattern formation of MTs where evaporation plays a significant role. The alignment of MTs was regulated reversibly by temperature induced polymerization and depolymerization of tubulins. The formation of the MTs patterns was also confirmed at the molecular level from the small angle X-ray measurements. This work provides a simple method for obtaining radially aligned arrays of MTs.
Collapse
Affiliation(s)
| | - Hiroki Kudoh
- Graduate School of Engineering, Tokyo University of Agriculture and Technology, Koganei, Tokyo, Japan
| | | | - Daisuke Inoue
- Department of Human Science Faculty of Design, Kyushu University, Fukuoka, Japan
| | - Nobuyoshi Miyamoto
- Department of Life, Environment and Materials Science, Fukuoka Institute of Technology, Fukuoka, Japan
| | - Tomomi Tani
- Eugene Bell Center for Regenerative Biology and Tissue Engineering, Marine Biological Laboratory, Woods Hole, MA, United States of America
| | - Akira Kakugo
- Faculty of Science, Hokkaido University, Sapporo, Hokkaido, Japan
- Graduate School of Chemical Sciences and Engineering, Hokkaido University, Sapporo, Hokkaido, Japan
- * E-mail: (AK); (KS)
| | - Kazuhiro Shikinaka
- Research Institute for Chemical Process Technology, National Institute of Advanced Industrial Science and Technology, Sendai, Miyagi, Japan
- * E-mail: (AK); (KS)
| |
Collapse
|
14
|
Zhang JJ, Huang H, Lu XY. Molecular Dynamics Study of Binary Nanodroplet Evaporation on a Heated Homogeneous Substrate. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2020; 36:3439-3451. [PMID: 32183513 DOI: 10.1021/acs.langmuir.0c00019] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The evaporation mechanism of miscible binary nanodroplets from heated homogeneous surfaces was studied by molecular dynamics simulations, which has never been studied before. The binary droplets contain a hydrophilic component (type-2 particles) and a hydrophobic component (type-3 particles). It is shown that liquid-liquid interaction strength (ε23) and hydrophilic particle number fraction (φ) have great influence on the surface tension, wetting characteristics, evaporation patterns, evaporation rate, and local mass flux. It is observed that when ε23 ≥ 1, or φ ≈ 0.5, the evaporation mode is the constant-contact-angle mode. Otherwise, it is the mixed mode. We found that the evaporation rate becomes faster when φ and ε23 increase. The droplets become more hydrophilic when φ increases, which promotes heat transfer efficiency between the liquid-solid interface. Besides, a larger ε23 promotes the heat transfer inside the droplet. The mass transfer to the vapor phase occurs preferentially in the vicinity of TPCL (three phase contact line) in the hydrophilic systems (θ < θc), where θc is the critical contact angle, while in most hydrophobic systems (θ > θc), the mass flux close to the TPCL is suppressed. We found that θc ∈ (102°-106°), which is different from the theoretical one, θc = 90°. The discrepancy is attributed to the existence of the adsorption layer near the TPCL.
Collapse
Affiliation(s)
- Jia-Jian Zhang
- Department of Modern Mechanics, University of Science and Technology of China, Hefei, Anhui 230026, China
| | - Haibo Huang
- Department of Modern Mechanics, University of Science and Technology of China, Hefei, Anhui 230026, China
| | - Xi-Yun Lu
- Department of Modern Mechanics, University of Science and Technology of China, Hefei, Anhui 230026, China
| |
Collapse
|
15
|
Hamadeh L, Imran S, Bencsik M, Sharpe GR, Johnson MA, Fairhurst DJ. Machine Learning Analysis for Quantitative Discrimination of Dried Blood Droplets. Sci Rep 2020; 10:3313. [PMID: 32094359 PMCID: PMC7040018 DOI: 10.1038/s41598-020-59847-x] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2019] [Accepted: 01/24/2020] [Indexed: 01/30/2023] Open
Abstract
One of the most interesting and everyday natural phenomenon is the formation of different patterns after the evaporation of liquid droplets on a solid surface. The analysis of dried patterns from blood droplets has recently gained a lot of attention, experimentally and theoretically, due to its potential application in diagnostic medicine and forensic science. This paper presents evidence that images of dried blood droplets have a signature revealing the exhaustion level of the person, and discloses an entirely novel approach to studying human dried blood droplet patterns. We took blood samples from 30 healthy young male volunteers before and after exhaustive exercise, which is well known to cause large changes to blood chemistry. We objectively and quantitatively analysed 1800 images of dried blood droplets, developing sophisticated image processing analysis routines and optimising a multivariate statistical machine learning algorithm. We looked for statistically relevant correlations between the patterns in the dried blood droplets and exercise-induced changes in blood chemistry. An analysis of the various measured physiological parameters was also investigated. We found that when our machine learning algorithm, which optimises a statistical model combining Principal Component Analysis (PCA) as an unsupervised learning method and Linear Discriminant Analysis (LDA) as a supervised learning method, is applied on the logarithmic power spectrum of the images, it can provide up to 95% prediction accuracy, in discriminating the physiological conditions, i.e., before or after physical exercise. This correlation is strongest when all ten images taken per volunteer per condition are averaged, rather than treated individually. Having demonstrated proof-of-principle, this method can be applied to identify diseases.
Collapse
Affiliation(s)
- Lama Hamadeh
- Department of Physics and Mathematics, School of Science and Technology, Nottingham Trent University, Nottingham, Clifton Campus, NG11 8NS, United Kingdom.
| | - Samia Imran
- Department of Physics and Mathematics, School of Science and Technology, Nottingham Trent University, Nottingham, Clifton Campus, NG11 8NS, United Kingdom
| | - Martin Bencsik
- Department of Physics and Mathematics, School of Science and Technology, Nottingham Trent University, Nottingham, Clifton Campus, NG11 8NS, United Kingdom
| | - Graham R Sharpe
- Exercise and Health Research Group, Sport, Health and Performance Enhancement (SHAPE) Research Centre, School of Science and Technology, Nottingham Trent University, Clifton Campus, NG11 8NS, United Kingdom
| | - Michael A Johnson
- Exercise and Health Research Group, Sport, Health and Performance Enhancement (SHAPE) Research Centre, School of Science and Technology, Nottingham Trent University, Clifton Campus, NG11 8NS, United Kingdom
| | - David J Fairhurst
- Department of Physics and Mathematics, School of Science and Technology, Nottingham Trent University, Nottingham, Clifton Campus, NG11 8NS, United Kingdom
| |
Collapse
|
16
|
Pal A, Gope A, Iannacchione GS. A Comparative Study of the Phase Separation of a Nematic Liquid Crystal in the Self-assembling Drying Protein Drops. ACTA ACUST UNITED AC 2019. [DOI: 10.1557/adv.2019.209] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
17
|
Glinská G, Krajčíková K, Zakutanská K, Shylenko O, Kondrakhova D, Tomašovičová N, Komanický V, Mašlanková J, Tomečková V. Noninvasive diagnostic methods for diabetes mellitus from tear fluid. RSC Adv 2019; 9:18050-18059. [PMID: 35520589 PMCID: PMC9064664 DOI: 10.1039/c9ra02078k] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Accepted: 05/08/2019] [Indexed: 12/03/2022] Open
Abstract
Diabetes mellitus and prolonged hyperglycemia can cause diabetic retinopathy. Diabetic retinopathy arises from damage to retinal vessels and, in its final stages, causes blindness. The early stages are often asymptomatic and although regular screening of diabetic patients is recommended, the beginning of diabetic retinopathy is insufficiently detected. The diagnostic potential of fluorescence spectroscopy, infrared spectroscopy and atomic force microscopy as the untraditional methods for diabetes mellitus was investigated using tear fluid. In our pilot study the structural changes of tear fluid of patients with diabetes mellitus after insulin and oral antidiabetic drug treatment was compared with healthy subjects. The results of analysis, infrared spectroscopy and atomic force microscopy confirmed structural changes in tear fluid of patients in comparison with the tear fluid of healthy subjects. Using new experimental laboratory methods in future could contribute to an improvement in diagnosis of diabetes mellitus and other selected ocular diseases using tear fluid. In our pilot study we assessed the diagnostic potential of FS, IRS and AFM for diabetes mellitus using tear fluid.![]()
Collapse
Affiliation(s)
- Gabriela Glinská
- Department of Medical and Clinical Biochemistry
- Faculty of Medicine
- Pavol Jozef Šafárik University in Košice
- 040 11 Košice
- Slovakia
| | - Kristína Krajčíková
- Department of Medical and Clinical Biochemistry
- Faculty of Medicine
- Pavol Jozef Šafárik University in Košice
- 040 11 Košice
- Slovakia
| | | | - Oleg Shylenko
- Department of Condensed Matter Physics
- Institute of Physics
- Faculty of Science
- Pavol Jozef Šafárik University in Košice
- 041 54 Košice
| | - Daria Kondrakhova
- Department of Condensed Matter Physics
- Institute of Physics
- Faculty of Science
- Pavol Jozef Šafárik University in Košice
- 041 54 Košice
| | | | - Vladimír Komanický
- Department of Condensed Matter Physics
- Institute of Physics
- Faculty of Science
- Pavol Jozef Šafárik University in Košice
- 041 54 Košice
| | - Jana Mašlanková
- Department of Medical and Clinical Biochemistry
- Faculty of Medicine
- Pavol Jozef Šafárik University in Košice
- 040 11 Košice
- Slovakia
| | - Vladimíra Tomečková
- Department of Medical and Clinical Biochemistry
- Faculty of Medicine
- Pavol Jozef Šafárik University in Košice
- 040 11 Košice
- Slovakia
| |
Collapse
|
18
|
Sett A, Ayushman M, Dasgupta S, DasGupta S. Analysis of the Distinct Pattern Formation of Globular Proteins in the Presence of Micro- and Nanoparticles. J Phys Chem B 2018; 122:8972-8984. [DOI: 10.1021/acs.jpcb.8b05325] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Ayantika Sett
- Department of Chemical Engineering, Indian Institute of Technology, 721302 Kharagpur, India
| | - Manish Ayushman
- Department of Chemical Engineering, Indian Institute of Technology, 721302 Kharagpur, India
| | - Swagata Dasgupta
- Department of Chemistry, Indian Institute of Technology, 721302 Kharagpur, India
| | - Sunando DasGupta
- Department of Chemical Engineering, Indian Institute of Technology, 721302 Kharagpur, India
| |
Collapse
|
19
|
Ozturk T, Erbil HY. Evaporation of water-ethanol binary sessile drop on fluoropolymer surfaces: Influence of relative humidity. Colloids Surf A Physicochem Eng Asp 2018. [DOI: 10.1016/j.colsurfa.2018.05.076] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
20
|
Texture analysis of protein deposits produced by droplet evaporation. Sci Rep 2018; 8:9580. [PMID: 29942029 PMCID: PMC6018122 DOI: 10.1038/s41598-018-27959-0] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Accepted: 06/12/2018] [Indexed: 11/25/2022] Open
Abstract
The deposit patterns derived from droplet evaporation allow current development of medical tests and new strategies for diagnostic in patients. For such purpose, the development and implementation of algorithms capable of characterizing and differentiating deposits are crucial elements. We report the study of deposit patterns formed by the droplet evaporation of binary mixtures of proteins containing NaCl. Optical microscopy reveals aggregates such as tip arrow-shaped, dendritic and semi-rosette patterns, needle-like and scalloped lines structures, as well as star-like and prism-shaped salt crystals. We use the first-order statistics (FOS) and gray level co-occurrence matrix (GLCM) to characterize the complex texture of deposit patterns. Three significant findings arise from this analysis: first, the FOS and GLCM parameters structurally characterize protein deposits. Secondly, they conform to simple exponential laws that change as a function of the NaCl concentration. Finally, the parameters are capable of revealing the different structural changes that occur during the droplet evaporation.
Collapse
|
21
|
Sett A, Dasgupta S, DasGupta S. Rapid estimation of the β-sheet content of Human Serum Albumin from the drying patterns of HSA-nanoparticle droplets. Colloids Surf A Physicochem Eng Asp 2018. [DOI: 10.1016/j.colsurfa.2017.12.064] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|