Shen C, Gharleghi R, Li DD, Beier S. Helical Flow in Healthy and Diseased Patient-specific Coronary Bifurcations. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2022; 2022:3977-3980. [PMID: 36086059 DOI: 10.1109/embc48229.2022.9871374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Helical flow (HF) exists in healthy and diseased coronary bifurcations and was found to have a protective atherosclerotic vascular effect in other vessels. However, the role of HF in patient-specific human coronary arteries still needs further study, and is therefore the objective of this study in both healthy and diseased bifurcations. Computational studies were conducted on 16 patient-specific coronary bifurcations, including eight healthy and eight identical cases with idealized narrowing to represent disease. In general, higher HF intensity may have a favorable effect as it corelated to the reduction of the percentage vessel area exposed to adverse time averaged wall shear stress (TAWSS%) in both healthy and diseased models. The HF intensity and distribution of each model varies due to the complex shape of patient-specific models. The presence of disease appears to have an important impact on the downstream HF patterns and the TAWSS distributions. Clinical Relevance- By understanding the relationship between HF and hemodynamics, HF may be used as a predictor for the formation and progression of atherosclerotic plaque in coronary arteries instead of near-wall WSS measures, which can be determined with higher accuracy in vivo.
Collapse
|
2
|
Carpenter HJ, Gholipour A, Ghayesh MH, Zander AC, Psaltis PJ. In Vivo Based Fluid-Structure Interaction Biomechanics of the Left Anterior Descending Coronary Artery. J Biomech Eng 2021; 143:1104434. [PMID: 33729476 DOI: 10.1115/1.4050540] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Indexed: 12/25/2022]
Abstract
A fluid-structure interaction-based biomechanical model of the entire left anterior descending coronary artery is developed from in vivo imaging via the finite element method in this paper. Included in this investigation is ventricle contraction, three-dimensional motion, all angiographically visible side branches, hyper/viscoelastic artery layers, non-Newtonian and pulsatile blood flow, and the out-of-phase nature of blood velocity and pressure. The fluid-structure interaction model is based on in vivo angiography of an elite athlete's entire left anterior descending coronary artery where the influence of including all alternating side branches and the dynamical contraction of the ventricle is investigated for the first time. Results show the omission of side branches result in a 350% increase in peak wall shear stress and a 54% decrease in von Mises stress. Peak von Mises stress is underestimated by up to 80% when excluding ventricle contraction and further alterations in oscillatory shear indices are seen, which provide an indication of flow reversal and has been linked to atherosclerosis localization. Animations of key results are also provided within a video abstract. We anticipate that this model and results can be used as a basis for our understanding of the interaction between coronary and myocardium biomechanics. It is hoped that further investigations could include the passive and active components of the myocardium to further replicate in vivo mechanics and lead to an understanding of the influence of cardiac abnormalities, such as arrythmia, on coronary biomechanical responses.
Collapse
Affiliation(s)
- Harry J Carpenter
- School of Mechanical Engineering, University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Alireza Gholipour
- School of Mechanical Engineering, University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Mergen H Ghayesh
- School of Mechanical Engineering, University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Anthony C Zander
- School of Mechanical Engineering, University of Adelaide, Adelaide, South Australia 5005, Australia
| | - Peter J Psaltis
- Vascular Research Centre, Lifelong Health Theme, South Australian Health and Medical Research Institute (SAHMRI), Adelaide, South Australia 5000, Australia; Adelaide Medical School, University of Adelaide, Adelaide, South Australia 5005, Australia; Department of Cardiology, Central Adelaide Local Health Network, Adelaide, South Australia 5000, Australia
| |
Collapse
|
3
|
Liu H, Ou S, Liu P, Xu Y, Gong Y, Xia L, Leng X, Leung TWH, Shi L, Zheng D. Effect of microcirculatory resistance on coronary blood flow and instantaneous wave-free ratio: A computational study. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2020; 196:105632. [PMID: 32615491 DOI: 10.1016/j.cmpb.2020.105632] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Accepted: 06/21/2020] [Indexed: 06/11/2023]
Abstract
BACKGROUND AND OBJECTIVE The instantaneous wave-free ratio (iFR) has been proposed to estimate the hemodynamic severity of atherosclerotic stenosis in coronary arteries. The atherosclerotic stenosis in a proximal coronary artery could change its distal microcirculatory resistance (MR). However, there is a lack of investigation about the effect of MR variation on the blood flow and iFR of stenotic coronary arteries. We aim to investigate the changes of blood flow and iFR caused by distal MR variation. METHODS Four three-dimensional models of coronary arteries were reconstructed from the computed tomography images of two normal cases and two cases with 74.9% and 96.4% (in area) stenoses in a large branch of left anterior descending artery (LAD). Computational fluid dynamics simulation was performed on each model under 6 MR situations: hyperemia as the reference situation, resting when MR was multiplied by 8/3 in all outlet branches, h-one-1.5 and h-one-2 when MR was multiplied by 1.5 and 2.0 in one branch (the stenotic, or the corresponding branch in normal case) of LAD, h-branches-1.5 and h-branches-2 when MR was multiplied by 1.5 and 2.0 in the stenotic/corresponding and its cognate branches. Flow rate and iFR of each outlet branch were then calculated and compared between different MR situations to investigate the effect of MR variation on flow rate and iFR. RESULTS In the 74.9% stenosed and normal cases, referring to the hyperemia situation, the increase of MR in any branch significantly decreased its flow rate and increased its iFR, with limited effect on the flow rate (<3%) and iFR (<0.01) of other branches. However, in the 96.4% stenosed case, the doubled MR in the stenosed branch (h-one-2) significantly increased the flow rate (>10%) and iFR (>0.05) of its cognate branches. CONCLUSION The increase of MR in a normal or mildly stenosed branch of coronary artery decreases its blood flow and increases its iFR, with limited effect on other branches. Whereas, the increase of MR in a severely stenotic large branch could significantly increase the flow velocity and iFR of its cognate branches.
Collapse
Affiliation(s)
- Haipeng Liu
- Research Centre for Intelligent Healthcare, Faculty of Health and Life Sciences, Coventry University, Coventry CV1 5FB, UK
| | - Shanxing Ou
- Department of Radiology, General Hospital of Southern Theater Command, PLA, Guangzhou, China
| | - Panli Liu
- Department of Radiology, Guangzhou First People's Hospital, Nansha Hospital, Guangzhou, China
| | - Yuhang Xu
- Research Centre for Intelligent Healthcare, Faculty of Health and Life Sciences, Coventry University, Coventry CV1 5FB, UK
| | - Yinglan Gong
- Department of Biomedical Engineering, Zhejiang University, Hangzhou, China
| | - Ling Xia
- Department of Biomedical Engineering, Zhejiang University, Hangzhou, China
| | - Xinyi Leng
- Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, Hong Kong, China
| | - Thomas Wai Hong Leung
- Department of Medicine and Therapeutics, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, Hong Kong, China
| | - Lin Shi
- Department of Imaging and Interventional Radiology, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, Hong Kong, China.
| | - Dingchang Zheng
- Research Centre for Intelligent Healthcare, Faculty of Health and Life Sciences, Coventry University, Coventry CV1 5FB, UK.
| |
Collapse
|
4
|
Song J, Kouidri S, Bakir F. Numerical study of hemodynamic and diagnostic parameters affected by stenosis in bifurcated artery. Comput Methods Biomech Biomed Engin 2020; 23:894-905. [PMID: 32519914 DOI: 10.1080/10255842.2020.1771557] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Stenosis in the bifurcated coronary artery has attracted wide attention among the researchers. Many investigations have been carried out by means of Computational Fluid Dynamics (CFD) to better understand the physical mechanism inside the stenotic bifurcated artery. However, the main focus of the existing publications is limited to the variation of hemodynamic parameters affected by the stenosis and bifurcation structure. The present study aims to make further evaluations of stenosis development and diagnostic lesion assessments based on the critical values of hemodynamic and practical diagnostic parameters. The bifurcated coronary artery with initial stenosis source has been studied in 2 D unsteady model. Different locations of initial stenosis source have been found to greatly affect the orientation of the further stenosis development. In addition, different stenosis severities (diameter stenosis: 30%, 50% and 70%), different stenosis lengths (3 mm, 6 mm and 9 mm) and different pulse rates (75 bpm, 100 bpm and 120 bpm) as controlling parameters have been investigated.
Collapse
Affiliation(s)
- Jianfei Song
- LIFSE, Arts et Metiers Institute of Technology, CNAM, LIFSE, HESAM University, Paris, France.,Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, Tianjin, China
| | - Smaine Kouidri
- LIMSI, CNRS, Université Paris-Saclay, Orsay Cedex, France.,Sorbonne Universités, UPMC Univ Paris 06, UFR d'Ingénierie, Paris Cedex 05, France
| | - Farid Bakir
- LIFSE, Arts et Metiers Institute of Technology, CNAM, LIFSE, HESAM University, Paris, France
| |
Collapse
|
5
|
Transfer of Low-Density Lipoproteins in Coronary Artery Bifurcation Lesions with Stenosed Side Branch: Numerical Study. COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE 2019; 2019:5297284. [PMID: 31737085 PMCID: PMC6815532 DOI: 10.1155/2019/5297284] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Revised: 07/08/2019] [Accepted: 08/04/2019] [Indexed: 11/17/2022]
Abstract
Evidence from clinical data suggests that the stenotic side branch (SB) is one of the key predictors for SB occlusion-based adverse events. In this study, we hypothesized that coronary bifurcations with stenotic SB might lead to severe concentration polarization of atherogenic lipids, such as the low-density lipoproteins (LDL), motivating the adverse events in the clinic. To confirm this hypothesis, this work numerically investigated the transport of LDL in different bifurcation lesions based on the Medina classification with various location and stenosis severities. The results showed that the coronary bifurcations with stenotic SB might be suffering more serious concentration polarization of LDL on the luminal surface of the SB due to higher level of LDL concentrations. Moreover, compared to the other bifurcation lesion types, the type (1,0,1) had the highest luminal surface LDL concentration along the SB and the highest degree of risk to enhance the process of atherosclerosis. In addition, this study also showed that the luminal surface LDL concentration increased with elevated stenosis severity. The type (1,0,1) with the severe stenosis (75% diameter reduction) had the highest concentration at the SB. In conclusion, these results suggested that both location of lesions and stenosis severities had great influence on the distribution of LDL on the luminal surface of the SB. Therefore, the estimation of disease severity and the interventional therapy should be carried out not only according to the stenosis severities in clinic. Moreover, compared to the other bifurcation lesion types, the type (1,0,1), rather than the type (1,1,1) as usually considered, had the highest luminal surface LDL concentration along the SB and the highest degree of risk to enhance the process of atherosclerosis.
Collapse
|
6
|
Razavi SE, Farhangmehr V, Babaie Z. Numerical investigation of hemodynamic performance of a stent in the main branch of a coronary artery bifurcation. ACTA ACUST UNITED AC 2019; 9:97-103. [PMID: 31334041 PMCID: PMC6637217 DOI: 10.15171/bi.2019.13] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2018] [Revised: 12/11/2018] [Accepted: 12/26/2018] [Indexed: 01/09/2023]
Abstract
Introduction: The effect of a bare-metal stent on the hemodynamics in the main branch of a coronary artery bifurcation with a particular type of stenosis was numerically investigated by the computational fluid dynamics (CFD). Methods: Three-dimensional idealized geometry of bifurcation was constructed in Catia modelling commercial software package. The Newtonian blood flow was assumed to be incompressible and laminar. CFD was utilized to calculate the shear stress and blood pressure distributions on the wall of main branch. In order to do the numerical simulations, a commercial software package named as COMSOL Multiphysics 5.3 was employed. Two types of stent , namely, one-part stent and two-part stent were applied to prevent the build-up and progression of the atherosclerotic plaques in the main branch. Results: A particular type of stenosis in the main branch was considered in this research. It occurred before and after the side branch. Moreover, it was found that the main branch with an inserted one-part stent had the smallest region with the wall shear stress (WSS) below 0.5 Pa which was the minimum WSS in the main branch without the stenosis. Conclusion: The use of a one-part stent in the main branch of a coronary artery bifurcation for the aforementioned type of stenosis is recommended.
Collapse
Affiliation(s)
| | - Vahid Farhangmehr
- Department of Mechanical Engineering, University of Bonab, Bonab 5551761167, Iran
| | - Zahra Babaie
- Department of Mechanical Engineering, University of Tabriz, Tabriz, Iran
| |
Collapse
|
7
|
Discrete-Phase Modelling of an Asymmetric Stenosis Artery Under Different Womersley Numbers. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING 2019. [DOI: 10.1007/s13369-018-3391-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
|
8
|
Morbiducci U, Kok AM, Kwak BR, Stone PH, Steinman DA, Wentzel JJ. Atherosclerosis at arterial bifurcations: evidence for the role of haemodynamics and geometry. Thromb Haemost 2018; 115:484-92. [DOI: 10.1160/th15-07-0597] [Citation(s) in RCA: 131] [Impact Index Per Article: 21.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2015] [Accepted: 11/13/2015] [Indexed: 11/05/2022]
Abstract
SummaryAtherosclerotic plaques are found at distinct locations in the arterial system, despite the exposure to systemic risk factors of the entire vascular tree. From the study of arterial bifurcation regions, emerges ample evidence that haemodynamics are involved in the local onset and progression of the atherosclerotic disease. This observed co-localisation of disturbed flow regions and lesion prevalence at geometrically predisposed districts such as arterial bifurcations has led to the formulation of a ‘haemodynamic hypothesis’, that in this review is grounded to the most current research concerning localising factors of vascular disease. In particular, this review focuses on carotid and coronary bifurcations because of their primary relevance to stroke and heart attack. We highlight reported relationships between atherosclerotic plaque location, progression and composition, and fluid forces at vessel’s wall, in particular shear stress and its ‘easier-tomeasure’ surrogates, i.e. vascular geometric attributes (because geometry shapes the flow) and intravascular flow features (because they mediate disturbed shear stress), in order to give more insight in plaque initiation and destabilisation. Analogous to Virchow’s triad for thrombosis, atherosclerosis must be thought of as subject to a triad of, and especially interactions among, haemodynamic forces, systemic risk factors, and the biological response of the wall.
Collapse
|
9
|
Pagiatakis C, Tardif JC, L'Allier PL, Mongrain R. Effect of stenosis eccentricity on the functionality of coronary bifurcation lesions-a numerical study. Med Biol Eng Comput 2017; 55:2079-2095. [PMID: 28500478 DOI: 10.1007/s11517-017-1653-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2016] [Accepted: 04/25/2017] [Indexed: 01/10/2023]
Abstract
Interventional cardiologists still rely heavily on angiography for the evaluation of coronary lesion severity, despite its poor correlation with the presence of ischemia. In order to improve the accuracy of the current diagnostic procedures, an understanding of the relative influence of geometric characteristics on the induction of ischemia is required. This idea is especially important for coronary bifurcation lesions (CBLs), whose treatment is complex and is associated with high rates of peri- and post-procedural clinical events. Overall, it is unclear which geometric and morphological parameters of CBLs influence the onset of ischemia. More specifically, the effect of stenosis eccentricity is unknown. Computational fluid dynamic simulations, under a geometric multiscale framework, were executed for seven CBL configurations within the left main coronary artery bifurcation. Both concentric and eccentric stenosis profiles of mild to severe constriction were considered. By using a geometric multiscale framework, the fractional flow reserve, which is the gold-standard clinical diagnostic index, could be calculated and was compared between the eccentric and concentric profiles for each case. The results suggested that for configurations where the supplying vessel is stenosed, eccentricity could have a notable effect on and therefore be an important factor that influences configuration functionality.
Collapse
Affiliation(s)
- Catherine Pagiatakis
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke Street West, Montreal, Quebec, H3A 0C3, Canada. .,Montreal Heart Institute, 5000 Belanger Street, Montreal, Quebec, H1T 1C8, Canada.
| | - Jean-Claude Tardif
- Montreal Heart Institute, 5000 Belanger Street, Montreal, Quebec, H1T 1C8, Canada.,Faculty of Medicine, Université de Montréal - Pavillon Roger-Gaudry, 2900 Edouard-Montpetit Boulevard, Montreal, Quebec, H3T 1J4, Canada
| | - Philippe L L'Allier
- Montreal Heart Institute, 5000 Belanger Street, Montreal, Quebec, H1T 1C8, Canada.,Faculty of Medicine, Université de Montréal - Pavillon Roger-Gaudry, 2900 Edouard-Montpetit Boulevard, Montreal, Quebec, H3T 1J4, Canada
| | - Rosaire Mongrain
- Department of Mechanical Engineering, McGill University, 817 Sherbrooke Street West, Montreal, Quebec, H3A 0C3, Canada.,Montreal Heart Institute, 5000 Belanger Street, Montreal, Quebec, H1T 1C8, Canada
| |
Collapse
|
10
|
Chiastra C, Gallo D, Tasso P, Iannaccone F, Migliavacca F, Wentzel JJ, Morbiducci U. Healthy and diseased coronary bifurcation geometries influence near-wall and intravascular flow: A computational exploration of the hemodynamic risk. J Biomech 2017; 58:79-88. [PMID: 28457603 DOI: 10.1016/j.jbiomech.2017.04.016] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2017] [Revised: 04/08/2017] [Accepted: 04/11/2017] [Indexed: 01/09/2023]
Abstract
Local hemodynamics has been identified as one main determinant in the onset and progression of atherosclerotic lesions at coronary bifurcations. Starting from the observation that atherosensitive hemodynamic conditions in arterial bifurcation are majorly determined by the underlying anatomy, the aim of the present study is to investigate how peculiar coronary bifurcation anatomical features influence near-wall and intravascular flow patterns. Different bifurcation angles and cardiac curvatures were varied in population-based, idealized models of both stenosed and unstenosed bifurcations, representing the left anterior descending (LAD) coronary artery with its diagonal branch. Local hemodynamics was analyzed in terms of helical flow and exposure to low/oscillatory shear stress by performing computational fluid dynamics simulations. Results show that bifurcation angle impacts lowly hemodynamics in both stenosed and unstenosed cases. Instead, curvature radius influences the generation and transport of helical flow structures, with smaller cardiac curvature radius associated to higher helicity intensity. Stenosed bifurcation models exhibit helicity intensity values one order of magnitude higher than the corresponding unstenosed cases. Cardiac curvature radius moderately affects near-wall hemodynamics of the stenosed cases, with smaller curvature radius leading to higher exposure to low shear stress and lower exposure to oscillatory shear stress. In conclusion, the proposed controlled benchmark allows investigating the effect of various geometrical features on local hemodynamics at the LAD/diagonal bifurcation, highlighting that cardiac curvature influences near wall and intravascular hemodynamics, while bifurcation angle has a minor effect.
Collapse
Affiliation(s)
- Claudio Chiastra
- Department of Cardiology, Biomedical Engineering, Erasmus MC, Rotterdam, The Netherlands; Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Diego Gallo
- Polito(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | - Paola Tasso
- Polito(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | | | - Francesco Migliavacca
- Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Jolanda J Wentzel
- Department of Cardiology, Biomedical Engineering, Erasmus MC, Rotterdam, The Netherlands
| | - Umberto Morbiducci
- Polito(BIO)Med Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy.
| |
Collapse
|
11
|
Chiastra C, Iannaccone F, Grundeken MJ, Gijsen FJH, Segers P, De Beule M, Serruys PW, Wykrzykowska JJ, van der Steen AFW, Wentzel JJ. Coronary fractional flow reserve measurements of a stenosed side branch: a computational study investigating the influence of the bifurcation angle. Biomed Eng Online 2016; 15:91. [PMID: 27495804 PMCID: PMC4974683 DOI: 10.1186/s12938-016-0211-0] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2016] [Accepted: 07/20/2016] [Indexed: 12/31/2022] Open
Abstract
Background Coronary hemodynamics and physiology specific for bifurcation lesions was not well understood. To investigate the influence of the bifurcation angle on the intracoronary hemodynamics of side branch (SB) lesions computational fluid dynamics simulations were performed. Methods A parametric model representing a left anterior descending—first diagonal coronary bifurcation lesion was created according to the literature. Diameters obeyed fractal branching laws. Proximal and distal main branch (DMB) stenoses were both set at 60 %. We varied the distal bifurcation angles (40°, 55°, and 70°), the flow splits to the DMB and SB (55 %:45 %, 65 %:35 %, and 75 %:25 %), and the SB stenoses (40, 60, and 80 %), resulting in 27 simulations. Fractional flow reserve, defined as the ratio between the mean distal stenosis and mean aortic pressure during maximal hyperemia, was calculated for the DMB and SB (FFRSB) for all simulations. Results The largest differences in FFRSB comparing the largest and smallest bifurcation angles were 0.02 (in cases with 40 % SB stenosis, irrespective of the assumed flow split) and 0.05 (in cases with 60 % SB stenosis, flow split 55 %:45 %). When the SB stenosis was 80 %, the difference in FFRSB between the largest and smallest bifurcation angle was 0.33 (flow split 55 %:45 %). By describing the ΔPSB−QSB relationship using a quadratic curve for cases with 80 % SB stenosis, we found that the curve was steeper (i.e. higher flow resistance) when bifurcation angle increases (ΔP = 0.451*Q + 0.010*Q2 and ΔP = 0.687*Q + 0.017*Q2 for 40° and 70° bifurcation angle, respectively). Our analyses revealed complex hemodynamics in all cases with evident counter-rotating helical flow structures. Larger bifurcation angles resulted in more pronounced helical flow structures (i.e. higher helicity intensity), when 60 or 80 % SB stenoses were present. A good correlation (R2 = 0.80) between the SB pressure drop and helicity intensity was also found. Conclusions Our analyses showed that, in bifurcation lesions with 60 % MB stenosis and 80 % SB stenosis, SB pressure drop is higher for larger bifurcation angles suggesting higher flow resistance (i.e. curves describing the ΔPSB−QSB relationship being steeper). When the SB stenosis is mild (40 %) or moderate (60 %), SB resistance is minimally influenced by the bifurcation angle, with differences not being clinically meaningful. Our findings also highlighted the complex interplay between anatomy, pressure drops, and blood flow helicity in bifurcations.
Collapse
Affiliation(s)
- Claudio Chiastra
- Department of Cardiology, Biomedical Engineering, Erasmus MC, Rotterdam, The Netherlands.,Laboratory of Biological Structure Mechanics (LaBS), Department of Chemistry, Materials and Chemical Engineering "Giulio Natta", Politecnico di Milano, Milan, Italy
| | - Francesco Iannaccone
- Department of Cardiology, Biomedical Engineering, Erasmus MC, Rotterdam, The Netherlands.,IbiTech-bioMMeda, Department of Electronics and Information Systems iMinds Medical IT, Ghent University, Ghent, Belgium
| | - Maik J Grundeken
- The Heart Center, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | - Frank J H Gijsen
- Department of Cardiology, Biomedical Engineering, Erasmus MC, Rotterdam, The Netherlands
| | - Patrick Segers
- IbiTech-bioMMeda, Department of Electronics and Information Systems iMinds Medical IT, Ghent University, Ghent, Belgium
| | - Matthieu De Beule
- IbiTech-bioMMeda, Department of Electronics and Information Systems iMinds Medical IT, Ghent University, Ghent, Belgium.,FEops bvba, Ghent, Belgium
| | - Patrick W Serruys
- International Centre for Circulatory Health, NHLI, Imperial College London, London, UK
| | - Joanna J Wykrzykowska
- The Heart Center, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | | | - Jolanda J Wentzel
- Department of Cardiology, Biomedical Engineering, Erasmus MC, Rotterdam, The Netherlands.
| |
Collapse
|
12
|
Peng C, Wang X, Xian Z, Liu X, Huang W, Xu P, Wang J. The Impact of the Geometric Characteristics on the Hemodynamics in the Stenotic Coronary Artery. PLoS One 2016; 11:e0157490. [PMID: 27310014 PMCID: PMC4911169 DOI: 10.1371/journal.pone.0157490] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2016] [Accepted: 05/30/2016] [Indexed: 01/15/2023] Open
Abstract
The alterations of the hemodynamics in the coronary arteries, which result from patient-specific geometric significances are complex. The effect of the stenosis on the blood flow alteration had been wildly reported, but the combinational contribution from geometric factors required a comprehensive investigation to provide patient-specific information for diagnosis and assisting in the decision on the further treatment strategies. In the present study, we investigated the correlation between hemodynamic parameters and individual geometric factors in the patient-specific coronary arteries. Computational fluid dynamic simulations were performed on 22 patient-specific 3-dimensional coronary artery models that were reconstructed based on computed tomography angiography images. Our results showed that the increasing severity of the stenosis is associated with the increased maximum wall shear stress at the stenosis region (r = 0.752, P < 0.001). In contrast, the length of the recirculation zone has a moderate association with the curvature of the lesion segment (r = 0.505, P = 0.019) and the length of the lesions (r = 0.527, P = 0.064). Moreover, bifurcation in the coronary arteries is significantly correlated with the occurrence of recirculation, whereas the severity of distal stenosis demonstrated an effect on the alteration of the flow in the upstream bifurcation. These findings could serve as an indication for treatment planning and assist in prognosis evaluation.
Collapse
Affiliation(s)
- Changnong Peng
- Department of Cardiology, Shenzhen Sun Yat-Sen cardiovascular hospital, Shenzhen 518112, China
| | - Xiaoqing Wang
- Department of Cardiology, Shenzhen Sun Yat-Sen cardiovascular hospital, Shenzhen 518112, China
| | - Zhanchao Xian
- Department of Cardiology, Shenzhen Sun Yat-Sen cardiovascular hospital, Shenzhen 518112, China
| | - Xin Liu
- Research center for biomedical information technology, Shenzhen institute of advance technology, Chinese academic of science, Shenzhen 518055, China
- * E-mail: (XL); (WH)
| | - Wenhua Huang
- Institutes of Clinical Anatomy, Southern Medical University, Guangzhou 510515, China
- * E-mail: (XL); (WH)
| | - Pengcheng Xu
- Institutes of Clinical Anatomy, Southern Medical University, Guangzhou 510515, China
| | - Jinyang Wang
- Institutes of Clinical Anatomy, Southern Medical University, Guangzhou 510515, China
| |
Collapse
|
13
|
Pinto SIS, Campos JBLM. Numerical study of wall shear stress-based descriptors in the human left coronary artery. Comput Methods Biomech Biomed Engin 2016; 19:1443-55. [PMID: 26883291 DOI: 10.1080/10255842.2016.1149575] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
The present work is about the application of wall shear stress descriptors - time averaged wall shear stress (TAWSS), oscillating shear index (OSI) and relative residence time (RRT) - to the study of blood flow in the left coronary artery (LCA). These descriptors aid the prediction of disturbed flow conditions in the vessels and play a significant role in the detection of potential zones of atherosclerosis development. Hemodynamic descriptors data were obtained, numerically, through ANSYS® software, for the LCA of a patient-specific geometry and for a 3D idealized model. Comparing both cases, the results are coherent, in terms of location and magnitude. Low TAWSS, high OSI and high RRT values are observed in the bifurcation - potential zone of atherosclerosis appearance. The dissimilarities observed in the TAWSS values, considering blood as a Newtonian or non-Newtonian fluid, releases the importance of the correct blood rheologic caracterization. Moreover, for a higher Reynolds number, the TAWSS values decrease in the bifurcation and along the LAD branch, increasing the probability of plaques deposition. Furthermore, for a stenotic LCA model, very low TAWSS and high RRT values in front and behind the stenosis are observed, indicating the probable extension, in the flow direction, of the lesion.
Collapse
Affiliation(s)
- S I S Pinto
- a Centro de Estudos de Fenómenos de Transporte, Departamento de Engenharia Química, Faculdade de Engenharia da Universidade do Porto , Porto , Portugal
| | - J B L M Campos
- a Centro de Estudos de Fenómenos de Transporte, Departamento de Engenharia Química, Faculdade de Engenharia da Universidade do Porto , Porto , Portugal
| |