1
|
Paccini M, Paschina G, De Beni S, Stefanov A, Kolev V, Patanè G. US & MR/CT Image Fusion with Markerless Skin Registration: A Proof of Concept. JOURNAL OF IMAGING INFORMATICS IN MEDICINE 2024:10.1007/s10278-024-01176-w. [PMID: 39020154 DOI: 10.1007/s10278-024-01176-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 05/18/2024] [Accepted: 05/31/2024] [Indexed: 07/19/2024]
Abstract
This paper presents an innovative automatic fusion imaging system that combines 3D CT/MR images with real-time ultrasound acquisition. The system eliminates the need for external physical markers and complex training, making image fusion feasible for physicians with different experience levels. The integrated system involves a portable 3D camera for patient-specific surface acquisition, an electromagnetic tracking system, and US components. The fusion algorithm comprises two main parts: skin segmentation and rigid co-registration, both integrated into the US machine. The co-registration aligns the surface extracted from CT/MR images with the 3D surface acquired by the camera, facilitating rapid and effective fusion. Experimental tests in different settings, validate the system's accuracy, computational efficiency, noise robustness, and operator independence.
Collapse
Affiliation(s)
| | | | | | | | - Velizar Kolev
- MedCom GmbH, Dolivostr., 11, Darmstadt, 64293, Germany
| | | |
Collapse
|
2
|
Wang Y, Fu T, Wu C, Xiao J, Fan J, Song H, Liang P, Yang J. Multimodal registration of ultrasound and MR images using weighted self-similarity structure vector. Comput Biol Med 2023; 155:106661. [PMID: 36827789 DOI: 10.1016/j.compbiomed.2023.106661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 01/22/2023] [Accepted: 02/09/2023] [Indexed: 02/12/2023]
Abstract
PROPOSE Multimodal registration of 2D Ultrasound (US) and 3D Magnetic Resonance (MR) for fusion navigation can improve the intraoperative detection accuracy of lesion. However, multimodal registration remains a challenge because of the poor US image quality. In the study, a weighted self-similarity structure vector (WSSV) is proposed to registrate multimodal images. METHOD The self-similarity structure vector utilizes the normalized distance of symmetrically located patches in the neighborhood to describe the local structure information. The texture weights are extracted using the local standard deviation to reduce the speckle interference in the US images. The multimodal similarity metric is constructed by combining a self-similarity structure vector with a texture weight map. RESULTS Experiments were performed on US and MR images of the liver from 88 groups of data including 8 patients and 80 simulated samples. The average target registration error was reduced from 14.91 ± 3.86 mm to 4.95 ± 2.23 mm using the WSSV-based method. CONCLUSIONS The experimental results show that the WSSV-based registration method could robustly align the US and MR images of the liver. With further acceleration, the registration framework can be potentially applied in time-sensitive clinical settings, such as US-MR image registration in image-guided surgery.
Collapse
Affiliation(s)
- Yifan Wang
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Tianyu Fu
- School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, PR China.
| | - Chan Wu
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Jian Xiao
- School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Jingfan Fan
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Hong Song
- School of Software, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Ping Liang
- Department of Interventional Ultrasound, Chinese PLA General Hospital, Beijing, 100853, PR China.
| | - Jian Yang
- Beijing Engineering Research Center of Mixed Reality and Advanced Display, School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, PR China.
| |
Collapse
|
3
|
Ramalhinho J, Tregidgo HFJ, Gurusamy K, Hawkes DJ, Davidson B, Clarkson MJ. Registration of Untracked 2D Laparoscopic Ultrasound to CT Images of the Liver Using Multi-Labelled Content-Based Image Retrieval. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:1042-1054. [PMID: 33326379 DOI: 10.1109/tmi.2020.3045348] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Laparoscopic Ultrasound (LUS) is recommended as a standard-of-care when performing laparoscopic liver resections as it images sub-surface structures such as tumours and major vessels. Given that LUS probes are difficult to handle and some tumours are iso-echoic, registration of LUS images to a pre-operative CT has been proposed as an image-guidance method. This registration problem is particularly challenging due to the small field of view of LUS, and usually depends on both a manual initialisation and tracking to compose a volume, hindering clinical translation. In this paper, we extend a proposed registration approach using Content-Based Image Retrieval (CBIR), removing the requirement for tracking or manual initialisation. Pre-operatively, a set of possible LUS planes is simulated from CT and a descriptor generated for each image. Then, a Bayesian framework is employed to estimate the most likely sequence of CT simulations that matches a series of LUS images. We extend our CBIR formulation to use multiple labelled objects and constrain the registration by separating liver vessels into portal vein and hepatic vein branches. The value of this new labeled approach is demonstrated in retrospective data from 5 patients. Results show that, by including a series of 5 untracked images in time, a single LUS image can be registered with accuracies ranging from 5.7 to 16.4 mm with a success rate of 78%. Initialisation of the LUS to CT registration with the proposed framework could potentially enable the clinical translation of these image fusion techniques.
Collapse
|
4
|
Heiselman JS, Jarnagin WR, Miga MI. Intraoperative Correction of Liver Deformation Using Sparse Surface and Vascular Features via Linearized Iterative Boundary Reconstruction. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:2223-2234. [PMID: 31976882 PMCID: PMC7314378 DOI: 10.1109/tmi.2020.2967322] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
During image guided liver surgery, soft tissue deformation can cause considerable error when attempting to achieve accurate localization of the surgical anatomy through image-to-physical registration. In this paper, a linearized iterative boundary reconstruction technique is proposed to account for these deformations. The approach leverages a superposed formulation of boundary conditions to rapidly and accurately estimate the deformation applied to a preoperative model of the organ given sparse intraoperative data of surface and subsurface features. With this method, tracked intraoperative ultrasound (iUS) is investigated as a potential data source for augmenting registration accuracy beyond the capacity of conventional organ surface registration. In an expansive simulated dataset, features including vessel contours, vessel centerlines, and the posterior liver surface are extracted from iUS planes. Registration accuracy is compared across increasing data density to establish how iUS can be best employed to improve target registration error (TRE). From a baseline average TRE of 11.4 ± 2.2 mm using sparse surface data only, incorporating additional sparse features from three iUS planes improved average TRE to 6.4 ± 1.0 mm. Furthermore, increasing the sparse coverage to 16 tracked iUS planes improved average TRE to 3.9 ± 0.7 mm, exceeding the accuracy of registration based on complete surface data available with more cumbersome intraoperative CT without contrast. Additionally, the approach was applied to three clinical cases where on average error improved 67% over rigid registration and 56% over deformable surface registration when incorporating additional features from one independent tracked iUS plane.
Collapse
Affiliation(s)
| | - William R. Jarnagin
- Department of Surgery at Memorial Sloan Kettering Cancer Center, New York, NY 10065 USA
| | - Michael I. Miga
- Department of Biomedical Engineering at Vanderbilt University, Nashville, TN 37235 USA
| |
Collapse
|
5
|
Application of Image Fusion in Diagnosis and Treatment of Liver Cancer. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10031171] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
With the accelerated development of medical imaging equipment and techniques, image fusion technology has been effectively applied for diagnosis, biopsy and radiofrequency ablation, especially for liver tumor. Tumor treatment relying on a single medical imaging modality might face challenges, due to the deep positioning of the lesions, operation history and the specific background conditions of the liver disease. Image fusion technology has been employed to address these challenges. Using the image fusion technology, one could obtain real-time anatomical imaging superimposed by functional images showing the same plane to facilitate the diagnosis and treatments of liver tumors. This paper presents a review of the key principles of image fusion technology, its application in tumor treatments, particularly in liver tumors, and concludes with a discussion of the limitations and prospects of the image fusion technology.
Collapse
|
6
|
Gonet M, Epel B, Elas M. Data processing of 3D and 4D in-vivo electron paramagnetic resonance imaging co-registered with ultrasound. 3D printing as a registration tool. COMPUTERS & ELECTRICAL ENGINEERING : AN INTERNATIONAL JOURNAL 2019; 74:130-137. [PMID: 30820068 PMCID: PMC6388699 DOI: 10.1016/j.compeleceng.2019.01.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
We present the concept of image registration using ultrasound (US) and electron paramagnetic resonance (EPR) imaging and discuss the benefits of this solution, as well as its limitations. Both phantoms and murine tumors were used to test US and EPR image co-registration. Comparison of dental molding cast immobilization and predesigned cradle revealed that the latter approach is more effective in stabilizing the fiducial position. In vivo imaging of mouse tumors, image registration and comparison of fiducials system for 3D spatial as well as 4D spatial-spectral EPR imaging supported by 3D US were demonstrated. Ultrasound may provide a convenient alternative to other anatomical imaging methods for image registration in preclinical research. Of particular interest is a fusion of US tissue structure, doppler vascular function and EPR oxygen or redox imaging.
Collapse
Affiliation(s)
- M Gonet
- 1. Department of Biophysics, Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University, Krakow, Poland
- 3. Novilet, Poznan, Poland
| | - B Epel
- 2. Department of Radiation and Cellular Oncology, and Center for EPR Imaging In Vivo Physiology, University of Chicago, Chicago, IL 60637, United States
| | - M Elas
- 1. Department of Biophysics, Faculty of Biochemistry, Biophysics and Biotechnology, Jagiellonian University, Krakow, Poland
| |
Collapse
|
7
|
Yang M, Ding H, Zhu L, Wang G. Ultrasound fusion image error correction using subject-specific liver motion model and automatic image registration. Comput Biol Med 2016; 79:99-109. [DOI: 10.1016/j.compbiomed.2016.10.008] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2016] [Revised: 09/17/2016] [Accepted: 10/11/2016] [Indexed: 10/20/2022]
|