Henriksson M, García-Alberola A, Goya R, Vadillo A, Melgarejo-Meseguer FM, Sandberg F, Sörnmo L. Changes in f-wave characteristics during cryoballoon catheter ablation.
Physiol Meas 2018;
39:105001. [PMID:
30183676 DOI:
10.1088/1361-6579/aadf1d]
[Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE
Changes in ECG-derived parameters are studied in atrial fibrillation (AF) patients undergoing cryoballoon catheter ablation.
APPROACH
Parameters characterizing f-wave frequency, morphology by phase dispersion, and amplitude are estimated using a model-based statistical approach. These parameters are studied before, during, and after ablation, as well as for AF type (paroxysmal/persistent). Seventy-seven (49/28 paroxysmal/persistent) AF patients undergoing de novo catheter ablation are included in the study, out of which 31 (16/15 paroxysmal/persistent) were in AF during the whole procedure. A signal quality index (SQI) is used to identify analyzable segments.
MAIN RESULTS
f-wave frequency decreased significantly during ablation (p = 0.001), in particular after ablation of the inferior right pulmonary vein (p < 0.05). Frequency and phase dispersion differed significantly between paroxysmal and persistent AF (p = 0.001 and p < 0.05, respectively).
SIGNIFICANCE
This study demonstrates that a decrease in f-wave frequency can be distinguished during catheter ablation. The use of an SQI ensures reliable analysis and produces results significantly different from those obtained without an SQI.
Collapse