Zhou C, Chase JG, Chen Y. Multi-level digital-twin models of pulmonary mechanics: correlation analysis of 3D CT lung volume and 2D Chest motion. Biomed Phys Eng Express 2024; 11:015008. [PMID: 39504133 DOI: 10.1088/2057-1976/ad8c47] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2024] [Accepted: 10/29/2024] [Indexed: 11/08/2024]
Abstract
Creating multi-level digital-twin models for mechanical ventilation requires a detailed estimation of regional lung volume. An accurate generic map between 2D chest surface motion and 3D regional lung volume could provide improved regionalisation and clinically acceptable estimates localising lung damage. This work investigates the relationship between CT lung volumes and the forced vital capacity (FVC) a surrogate of tidal volume proven linked to 2D chest motion. In particular, a convolutional neural network (CNN) with U-Net architecture is employed to build a lung segmentation model using a benchmark CT scan dataset. An automated thresholding method is proposed for image morphology analysis to improve model performance. Finally, the trained model is applied to an independent CT dataset with FVC measurements for correlation analysis of CT lung volume projection to lung recruitment capacity. Model training results show a clear improvement of lung segmentation performance with the proposed automated thresholding method compared to a typically suggested fixed value selection, achieving accuracy greater than 95% for both training and independent validation sets. The correlation analysis for 160 patients shows a good correlation ofRsquared value of 0.73 between the proposed 2D volume projection and the FVC value, which indicates a larger and denser projection of lung volume relative to a greater FVC value and lung recruitable capacity. The overall results thus validate the potential of using non-contact, non-invasive 2D measures to enable regionalising lung mechanics models to equivalent 3D models with a generic map based on the good correlation. The clinical impact of improved lung mechanics digital twins due to regionalising the lung mechanics and volume to specific lung regions could be very high in managing mechanical ventilation and diagnosing or locating lung injury or dysfunction based on regular monitoring instead of intermittent and invasive lung imaging modalities.
Collapse
Affiliation(s)
- Cong Zhou
- Department of Mechanical Engineering & Centre for Bioengineering, University of Canterbury, New Zealand
| | - J Geoffrey Chase
- Department of Mechanical Engineering & Centre for Bioengineering, University of Canterbury, New Zealand
| | - Yuhong Chen
- Intensive Care Unit, Hebei Medical University Fourth Affiliated Hospital and Hebei Provincial Tumor Hospital, Shijiazhuang, People's Republic of China
| |
Collapse
|
2
|
Chase JG, Desaive T, Zhou C, Sun Q, Lambermont B. Setting ventilation: what if tomorrow's technology solutions were possible today? Intensive Care Med 2024; 50:1961-1963. [PMID: 39158705 DOI: 10.1007/s00134-024-07599-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/01/2024] [Indexed: 08/20/2024]
Affiliation(s)
- James Geoffrey Chase
- Department of Mechanical Engineering, Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand.
| | - Thomas Desaive
- GIGA In-Silico Medicine, University of Liege, Liege, Belgium
| | - Cong Zhou
- Department of Mechanical Engineering, Centre for Bioengineering, University of Canterbury, Christchurch, New Zealand
| | - Qianhui Sun
- GIGA In-Silico Medicine, University of Liege, Liege, Belgium
| | - Bernard Lambermont
- Department of Intensive Care, Centre Hospitalier Universitaire de Liege, Liege, Belgium
| |
Collapse
|
3
|
Cushway J, Murphy L, Chase JG, Shaw G, Desaive T, Zhou C. Model based care in the ICU: A review of potential combined cardio-pulmonary models. PLoS One 2024; 19:e0306925. [PMID: 39446758 PMCID: PMC11500922 DOI: 10.1371/journal.pone.0306925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2023] [Accepted: 06/25/2024] [Indexed: 10/26/2024] Open
Abstract
Positive end-expiratory pressure results in a sustained positive intrathoracic pressure, which exerts pressure on intrathoracic vessels, resulting in cardiopulmonary interactions. This sustained positive intrathoracic pressure is known to decrease cardiac preload, and thus, decrease venous return, ultimately reducing both the stroke volume and stressed blood volume of the cardiovascular system. Currently, cardiovascular and pulmonary care are provided independently of one another. That positive end-expiratory pressure alters both stroke volume and stressed blood volume suggests both the pulmonary and cardiovascular state should be conjointly optimised. Optimising these systems in isolation may benefit one system, but have highly detrimental effects on the other. A combined cardiopulmonary model has the potential to provide a better understanding of patient specific pulmonary and cardiovascular state, as well as resulting cardiopulmonary interactions. This would enable simultaneous optimisation of all cardiovascular and pulmonary parameters. Cardiopulmonary interactions are highly patient specific and unpredictable, making accurate modelling of these interactions challenging. A previously validated cardiopulmonary model was found to have increasing errors at high positive end-expiratory pressures. A new iteration, the alpha model, was introduced to resolve this issue. This paper aims to review the alpha model against its predecessors, the previous cardiopulmonary model, and the original three chamber cardiovascular system model. All models are used to identify cardiovascular system parameters from measurements of 4 pigs during a preload reduction manoeuvre. Outputs and parameter estimations from models are compared to assess the relative performance of the alpha model against its predecessors. The novel alpha model was able to reduce model errors under high positive end-expiratory pressure, resulting in more accurate model outputs. At high positive end-expiratory pressures (20cmH2O), the alpha model had an average error of 11.24%, while the original cardiopulmonary model had a much higher error of 52.21%. Furthermore, identified outputs of the alpha model more closely matched those of the 3 chamber model than the previous cardiopulmonary model. On average, at high positive end-expiratory levels, identified model parameters from the alpha model showed a 6.21% difference to those of the 3 chamber model, while the cardiopulmonary model displayed a 39.43% difference. The alpha model proved to be more stable than the original cardiopulmonary model, making it a good candidate for model based care. However, it produced similar parameter outputs to the simpler three chamber cardiovascular model, bringing into question whether the additional complexity is justified, especially considering the low availability of clinical data in the ICU. There is a critical need for model based care to guide important procedures in ICU, such as fluid therapy. Candidate models should be continuously reviewed in order to guarantee the best possible care.
Collapse
Affiliation(s)
- James Cushway
- GIGA-In Silico Medicine, University of Liège (ULg), Liège, Belgium
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Liam Murphy
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - J. Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - Geoffrey Shaw
- Dept of Intensive Care, Christchurch Hospital, Christchurch, New Zealand
| | - Thomas Desaive
- GIGA-In Silico Medicine, University of Liège (ULg), Liège, Belgium
| | - Cong Zhou
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| |
Collapse
|
4
|
Ang CYS, Chiew YS, Wang X, Ooi EH, Cove ME, Chen Y, Zhou C, Chase JG. Patient-ventilator asynchrony classification in mechanically ventilated patients: Model-based or machine learning method? COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 255:108323. [PMID: 39029417 DOI: 10.1016/j.cmpb.2024.108323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Revised: 06/27/2024] [Accepted: 07/10/2024] [Indexed: 07/21/2024]
Abstract
BACKGROUND AND OBJECTIVE Patient-ventilator asynchrony (PVA) is associated with poor clinical outcomes and remains under-monitored. Automated PVA detection would enable complete monitoring standard observational methods do not allow. While model-based and machine learning PVA approaches exist, they have variable performance and can miss specific PVA events. This study compares a model and rule-based algorithm with a machine learning PVA method by retrospectively validating both methods using an independent patient cohort. METHODS Hysteresis loop analysis (HLA) which is a rule-based method (RBM) and a tri-input convolutional neural network (TCNN) machine learning model are used to classify 7 different types of PVA, including: 1) flow asynchrony; 2) reverse triggering; 3) premature cycling; 4) double triggering; 5) delayed cycling; 6) ineffective efforts; and 7) auto triggering. Class activation mapping (CAM) heatmaps visualise sections of respiratory waveforms the TCNN model uses for decision making, improving result interpretability. Both PVA classification methods were used to classify incidence in an independent retrospective clinical cohort of 11 mechanically ventilated patients for validation and performance comparison. RESULTS Self-validation with the training dataset shows overall better HLA performance (accuracy, sensitivity, specificity: 97.5 %, 96.6 %, 98.1 %) compared to the TCNN model (accuracy, sensitivity, specificity: 89.5 %, 98.3 %, 83.9 %). In this study, the TCNN model demonstrates higher sensitivity in detecting PVA, but HLA was better at identifying non-PVA breathing cycles due to its rule-based nature. While the overall AI identified by both classification methods are very similar, the intra-patient distribution of each PVA type varies between HLA and TCNN. CONCLUSION The collective findings underscore the efficacy of both HLA and TCNN in PVA detection, indicating the potential for real-time continuous monitoring of PVA. While ML methods such as TCNN demonstrate good PVA identification performance, it is essential to ensure optimal model architecture and diversity in training data before widespread uptake as standard care. Moving forward, further validation and adoption of RBM methods, such as HLA, offers an effective approach to PVA detection while providing clear distinction into the underlying patterns of PVA, better aligning with clinical needs for transparency, explicability, adaptability and reliability of these emerging tools for clinical care.
Collapse
Affiliation(s)
| | - Yeong Shiong Chiew
- School of Engineering, Monash University Malaysia, Selangor, Malaysia; Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand.
| | - Xin Wang
- School of Engineering, Monash University Malaysia, Selangor, Malaysia
| | - Ean Hin Ooi
- School of Engineering, Monash University Malaysia, Selangor, Malaysia
| | - Matthew E Cove
- Division of Respiratory & Critical Care Medicine, Department of Medicine, National University Health System, Singapore
| | - Yuhong Chen
- Intensive Care Unit, the Fourth Hospital of Hebei Medical University, Shijiazhuang, Hebei Province, China
| | - Cong Zhou
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| | - J Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, Christchurch, New Zealand
| |
Collapse
|
5
|
Yang Tay W, Yew Shuen Ang C, Shiong Chiew Y, Geoffrey Chase J. CARETestLung: A mechanical test lung with Configurable airway Resistance, lung Elastance, and breathing efforts. HARDWAREX 2024; 19:e00579. [PMID: 39318641 PMCID: PMC11419886 DOI: 10.1016/j.ohx.2024.e00579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/22/2024] [Revised: 08/25/2024] [Accepted: 08/26/2024] [Indexed: 09/26/2024]
Abstract
A mechanical test lung is a crucial tool in accurately simulating patient-specific physiological responses of patients undergoing mechanical ventilation (MV), which, in turn, offer clinicians insight into lung mechanics during MV. In particular, it can be used to facilitate better methods to identify optimal ventilator settings, modes for individual patients by providing a platform to experiment with different MV settings. This addresses the challenge of optimising MV settings caused by variability in pathological conditions and the progression of respiratory disease over time within patients. However, the accessibility and cost of versatile test lungs limit widespread adoption in clinical settings, underscoring the need for affordable alternatives. This paper presents detailed instructions for the design and construction of a replicable, cost-effective mechanical test lung. The design features 3 subsystems: 1) the lung compartment; 2) the airway; and 3) a spontaneous breathing system. A detailed tests series shows its ability to replicate clinically realistic lung elastance values ranging from 25 to 85 cmH2O/L and airway resistance values from 10 to 45 cmH2O·s/L. It can also simulate a range of clinically realistic spontaneous breathing patterns. These capabilities yield pressure and flow ventilation data comparable to certified clinical test lungs across diverse scenarios, as well as matching clinically observed behaviours and dynamics. This accessible and versatile test lung offers valuable opportunities for optimising MV settings and advancing patient care, as well as its use in developing a range of physiological models for model-based decision support.
Collapse
Affiliation(s)
- Wei Yang Tay
- Monash University Malaysia, Jalan Lagoon Selatan, Bandar Sunway, 47500 Subang Jaya, Selangor, Malaysia
| | - Christopher Yew Shuen Ang
- Monash University Malaysia, Jalan Lagoon Selatan, Bandar Sunway, 47500 Subang Jaya, Selangor, Malaysia
| | - Yeong Shiong Chiew
- Monash University Malaysia, Jalan Lagoon Selatan, Bandar Sunway, 47500 Subang Jaya, Selangor, Malaysia
- Department of Mechanical Engineering, University of Canterbury, Christchurch 8041, New Zealand
| | - J Geoffrey Chase
- Department of Mechanical Engineering, University of Canterbury, Christchurch 8041, New Zealand
| |
Collapse
|
6
|
Caljé-van der Klei T, Sun Q, Chase JG, Zhou C, Tawhai MH, Knopp JL, Möller K, Heines SJ, Bergmans DC, Shaw GM. Pulmonary response prediction through personalized basis functions in a virtual patient model. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2024; 244:107988. [PMID: 38171168 DOI: 10.1016/j.cmpb.2023.107988] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2023] [Revised: 11/16/2023] [Accepted: 12/17/2023] [Indexed: 01/05/2024]
Abstract
BACKGROUND AND OBJECTIVE Recruitment maneuvers with subsequent positive-end-expiratory-pressure (PEEP) have proven effective in recruiting lung volume and preventing alveoli collapse. However, determining a safe, effective, and patient-specific PEEP is not standardized, and this more optimal PEEP level evolves with patient condition, requiring personalised monitoring and care approaches to maintain optimal ventilation settings. METHODS This research examines 3 physiologically relevant basis function sets (exponential, parabolic, cumulative) to enable better prediction of elastance evolution for a virtual patient or digital twin model of MV lung mechanics, including novel elements to model and predict distension elastance. Prediction accuracy and robustness are validated against recruitment maneuver data from 18 volume-controlled ventilation (VCV) patients at 7 different baseline PEEP levels (0 to 12 cmH2O) and 14 pressure-controlled ventilation (PCV) patients at 4 different baseline PEEP levels (6 to 12 cmH2O), yielding 623 and 294 prediction cases, respectively. Predictions were made up to 12 cmH2O of added PEEP ahead, covering 6 × 2 cmH2O PEEP steps. RESULTS The 3 basis function sets yield median absolute peak inspiratory pressure (PIP) prediction error of 1.63 cmH2O for VCV patients, and median peak inspiratory volume (PIV) prediction error of 0.028 L for PCV patients. The exponential basis function set yields a better trade-off of overall performance across VCV and PCV prediction than parabolic and cumulative basis function sets from other studies. Comparing predicted and clinically measured distension prediction in VCV demonstrated consistent, robust high accuracy with R2 = 0.90-0.95. CONCLUSIONS The results demonstrate recruitment mechanics are best captured by an exponential basis function across different mechanical ventilation modes, matching physiological expectations, and accurately capture, for the first time, distension mechanics to within 5-10 % accuracy. Enabling the risk of lung injury to be predicted before changing ventilator settings. The overall outcomes significantly extend and more fully validate this digital twin or virtual mechanical ventilation patient model.
Collapse
Affiliation(s)
- Trudy Caljé-van der Klei
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Christchurch, New Zealand.
| | - Qianhui Sun
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Christchurch, New Zealand; University of Liége, Liége, Belgium
| | - J Geoffrey Chase
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Christchurch, New Zealand
| | - Cong Zhou
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Christchurch, New Zealand
| | - Merryn H Tawhai
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Jennifer L Knopp
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Christchurch, New Zealand
| | - Knut Möller
- Institute for Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Serge J Heines
- Department of Intensive Care, School of Medicine, Maastricht University, Maastricht, Netherlands
| | - Dennis C Bergmans
- Department of Intensive Care, School of Medicine, Maastricht University, Maastricht, Netherlands
| | - Geoffrey M Shaw
- Department of Intensive Care, Christchurch Hospital, Christchurch, New Zealand
| |
Collapse
|
7
|
Chen Y, Zhang K, Zhou C, Chase JG, Hu Z. Automated evaluation of typical patient-ventilator asynchronies based on lung hysteretic responses. Biomed Eng Online 2023; 22:102. [PMID: 37875890 PMCID: PMC10598979 DOI: 10.1186/s12938-023-01165-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2023] [Accepted: 10/16/2023] [Indexed: 10/26/2023] Open
Abstract
BACKGROUND Patient-ventilator asynchrony is common during mechanical ventilation (MV) in intensive care unit (ICU), leading to worse MV care outcome. Identification of asynchrony is critical for optimizing MV settings to reduce or eliminate asynchrony, whilst current clinical visual inspection of all typical types of asynchronous breaths is difficult and inefficient. Patient asynchronies create a unique pattern of distortions in hysteresis respiratory behaviours presented in pressure-volume (PV) loop. METHODS Identification method based on hysteretic lung mechanics and hysteresis loop analysis is proposed to delineate the resulted changes of lung mechanics in PV loop during asynchronous breathing, offering detection of both its incidence and 7 major types. Performance is tested against clinical patient data with comparison to visual inspection conducted by clinical doctors. RESULTS The identification sensitivity and specificity of 11 patients with 500 breaths for each patient are above 89.5% and 96.8% for all 7 types, respectively. The average sensitivity and specificity across all cases are 94.6% and 99.3%, indicating a very good accuracy. The comparison of statistical analysis between identification and human inspection yields the essential same clinical judgement on patient asynchrony status for each patient, potentially leading to the same clinical decision for setting adjustment. CONCLUSIONS The overall results validate the accuracy and robustness of the identification method for a bedside monitoring, as well as its ability to provide a quantified metric for clinical decision of ventilator setting. Hence, the method shows its potential to assist a more consistent and objective assessment of asynchrony without undermining the efficacy of the current clinical practice.
Collapse
Affiliation(s)
- Yuhong Chen
- Intensive Care Unit, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Kun Zhang
- Intensive Care Unit, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| | - Cong Zhou
- Department of Mechanical Engineering & Centre for Bio-Engineering, University of Canterbury, Christchurch, New Zealand.
- Taicang Yangtze River Delta Research Institute, Suzhou, China.
| | - J Geoffrey Chase
- Department of Mechanical Engineering & Centre for Bio-Engineering, University of Canterbury, Christchurch, New Zealand
| | - Zhenjie Hu
- Intensive Care Unit, The Fourth Hospital of Hebei Medical University, Shijiazhuang, China
| |
Collapse
|
8
|
Cushway J, Murphy L, Chase JG, Shaw GM, Desaive T. Modelling patient specific cardiopulmonary interactions. Comput Biol Med 2022; 151:106235. [PMID: 36334361 DOI: 10.1016/j.compbiomed.2022.106235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2022] [Revised: 09/19/2022] [Accepted: 10/22/2022] [Indexed: 12/27/2022]
Abstract
Mechanical ventilation is well known for having detrimental effects on the cardiovascular system, particularly when using high positive end-expiratory pressure. High positive end-expiratory pressure levels cause a decrease in stroke volume, which, under normal conditions, usually bring about a decrease in stressed blood volume. Stressed blood volume, defined as the total pressure generating volume of the cardiovascular system, has been shown to be a potential index of fluid responsiveness, making it a potentially important diagnostic tool. Generally, respiratory and haemodynamic care are provided independently of one another. However, that positive end-expiratory pressure alters both stroke volume and stressed blood volume suggests both the pulmonary and cardiovascular state should be conjointly optimised and used to guide positive end-expiratory pressure. However, the complex and patient-specific nature of cardiopulmonary interactions which occur during mechanical ventilation presents a challenge for accurate modelling of respiratory and cardiovascular interactions required to better optimise care. Previous models attempting to incorporate cardiopulmonary interactions have suffered from poor reliability at higher PEEP levels, largely due to an exaggerated effect of intrathoracic pressure on the cardiovascular system. A new parameter, alpha, is added to a previously validated cardiopulmonary model, to modulate the percentage of intrathoracic pressure applied to the vena cava and left ventricle. The new parameter aims to increase reliability under high PEEP conditions as well as provide a patient specific solution to modelling cardiopulmonary interactions. The results from the identified optimal alpha are compared to the original model to investigate how this new parameter may be used to create a more patient-specific cardiopulmonary model, which would be better suited for guidance of care in the ICU.
Collapse
Affiliation(s)
- James Cushway
- University of Canterbury, Department of Mechanical Engineering, Christchurch, New Zealand; University of Liège (ULg), GIGA-Cardiovascular Sciences, Liège, Belgium.
| | - Liam Murphy
- University of Canterbury, Department of Mechanical Engineering, Christchurch, New Zealand
| | - J Geoffrey Chase
- University of Canterbury, Department of Mechanical Engineering, Christchurch, New Zealand
| | - Geoffrey M Shaw
- Department of Intensive Care, Christchurch Hospital, Christchurch, New Zealand
| | - Thomas Desaive
- University of Liège (ULg), GIGA-Cardiovascular Sciences, Liège, Belgium
| |
Collapse
|
9
|
Zhou C, Chase JG. Low-cost structured light imaging of regional volume changes for use in assessing mechanical ventilation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 226:107176. [PMID: 36228494 DOI: 10.1016/j.cmpb.2022.107176] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 09/21/2022] [Accepted: 10/04/2022] [Indexed: 06/16/2023]
Abstract
BACKGROUND Optimal setting of mechanical ventilators is critical for improving outcomes. Accurate, predictive lung mechanics models are effective in optimizing MV settings, but only at a global level as they cannot estimate regional lung volume ventilation to assess the potential of local distension or under-ventilation. This study presents a low-cost structured light system for non-contact high resolution chest motion measurement to estimate regional lung volume changes. METHODS The system consists of a structured light projector and two cameras. A new pattern is designed to extract motion from sub-regions of the chest surface, and an efficient feature is proposed to provide a fast and accurate correspondence matching between two views. Reconstruction of 3D surface points is based on the matched points and stereo method. Asymmetric distribution of tidal volume into left and right lungs is estimated based on reconstructed regional chest expansion. A proof-of-concept experiment using a dummy model and two test lungs connected to a ventilator to provide differential chest expansion is conducted under tidal volumes of 400 ml, 500 ml and 600 ml, with results compared to the widely-used SURF and ORB methods. RESULTS Compared to the SURF and ORB methods, the proposed method is more computationally efficient with ∼40% less computational time cost, and higher accuracy for dense point correspondence. Finally, the proposed method estimated the region lung volumes with the maximum error of 8 ml under 600 ml tidal volume, indicating a good accuracy. CONCLUSIONS Surface reconstruction results in a proof-of-concept experiment with differential chest expansion show good performance for the proposed pattern and method in extracting the key information for regional chest expansion. The proposed method is generalizable, with potential for use in other applications.
Collapse
Affiliation(s)
- Cong Zhou
- School of Civil Aviation, Northwestern Polytechnical University, China; Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Christchurch, New Zealand
| | - J Geoffrey Chase
- Department of Mechanical Engineering, Centre for Bio-Engineering, University of Canterbury, Christchurch, New Zealand.
| |
Collapse
|
10
|
Arn Ng Q, Yew Shuen Ang C, Shiong Chiew Y, Wang X, Pin Tan C, Basri Mat Nor M, Salwa Damanhuri N, Geoffrey Chase J. CAREDAQ: Data acquisition device for mechanical ventilation waveform monitoring. HARDWAREX 2022; 12:e00358. [PMID: 36117541 PMCID: PMC9474567 DOI: 10.1016/j.ohx.2022.e00358] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/25/2022] [Revised: 09/01/2022] [Accepted: 09/05/2022] [Indexed: 06/15/2023]
Abstract
Mechanical ventilation (MV) provides respiratory support for critically ill patients in the intensive care unit (ICU). Waveform data output by the ventilator provides valuable physiological and diagnostic information. However, existing systems do not provide full access to this information nor allow for real-time, non-invasive data collection. Therefore, large amounts of data are lost and analysis is limited to short samples of breathing cycles. This study presents a data acquisition device for acquiring and monitoring patient ventilation waveform data. Acquired data can be exported to other systems, allowing users to further analyse data and develop further clinically useful parameters. These parameters, together with other ventilatory information, can help personalise and guide MV treatment. The device is designed to be easily replicable, low-cost, and scalable according to the number of patient beds. Validation was carried out by assessing system performance and stability over prolonged periods of 7 days of continuous use. The device provides a platform for future integration of machine-learning or model-based modules, potentially allowing real-time, proactive, patient-specific MV guidance and decision support to improve the quality and productivity of care and outcomes.
Collapse
Affiliation(s)
- Qing Arn Ng
- School of Engineering, Monash University Malaysia, Subang Jaya, Selangor 47500, Malaysia
| | | | - Yeong Shiong Chiew
- School of Engineering, Monash University Malaysia, Subang Jaya, Selangor 47500, Malaysia
| | - Xin Wang
- School of Engineering, Monash University Malaysia, Subang Jaya, Selangor 47500, Malaysia
| | - Chee Pin Tan
- School of Engineering, Monash University Malaysia, Subang Jaya, Selangor 47500, Malaysia
| | - Mohd Basri Mat Nor
- Kulliyah of Medicine, International Islamic University Malaysia, Kuantan, Pahang 25200, Malaysia
| | - Nor Salwa Damanhuri
- Faculty of Electrical Engineering, Universiti Teknologi MARA, Cawangan Pulau Pinang, 13500, Permatang Pauh, Pulau Pinang, Malaysia
| | - J. Geoffrey Chase
- Center of Bioengineering, University of Canterbury, Christchurch 8041, New Zealand
| |
Collapse
|
11
|
Non-invasive over-distension measurements: data driven vs model-based. J Clin Monit Comput 2022; 37:389-398. [PMID: 35920951 DOI: 10.1007/s10877-022-00900-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Accepted: 07/22/2022] [Indexed: 10/16/2022]
Abstract
Clinical measurements offer bedside monitoring aiming to minimise unintended over-distension, but have limitations and cannot be predicted for changes in mechanical ventilation (MV) settings and are only available in certain MV modes. This study introduces a non-invasive, real-time over-distension measurement, which is robust, predictable, and more intuitive than current methods. The proposed over-distension measurement, denoted as OD, is compared with the clinically proven stress index (SI). Correlation is analysed via R2 and Spearman rs. The OD safe range corresponding to the unit-less SI safe range (0.95-1.05) is calibrated by sensitivity and specificity test. Validation is fulfilled with 19 acute respiratory distress syndrome (ARDS) patients data (196 cases), including assessment across ARDS severity. Overall correlation between OD and SI yielded R2 = 0.76 and Spearman rs = 0.89. Correlation is higher considering only moderate and severe ARDS patients. Calibration of OD to SI yields a safe range defined: 0 ≤ OD ≤ 0.8 cmH2O. The proposed OD offers an efficient, general, real-time measurement of patient-specific lung mechanics, which is more intuitive and robust than SI. OD eliminates the limitations of SI in MV mode and its less intuitive lung status value. Finally, OD can be accurately predicted for new ventilator settings via its foundation in a validated predictive personalized lung mechanics model. Therefore, OD offers potential clinical value over current clinical methods.
Collapse
|
12
|
Lee JWW, Chiew YS, Wang X, Mat Nor MB, Chase JG, Desaive T. Stochastic integrated model-based protocol for volume-controlled ventilation setting. Biomed Eng Online 2022; 21:13. [PMID: 35148759 PMCID: PMC8832735 DOI: 10.1186/s12938-022-00981-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Accepted: 01/21/2022] [Indexed: 11/14/2022] Open
Abstract
BACKGROUND AND OBJECTIVE Mechanical ventilation (MV) is the primary form of care for respiratory failure patients. MV settings are based on general clinical guidelines, intuition, and experience. This approach is not patient-specific and patients may thus experience suboptimal, potentially harmful MV care. This study presents the Stochastic integrated VENT (SiVENT) protocol which combines model-based approaches of the VENT protocol from previous works, with stochastic modelling to take the variation of patient respiratory elastance over time into consideration. METHODS A stochastic model of Ers is integrated into the VENT protocol from previous works to develop the SiVENT protocol, to account for both intra- and inter-patient variability. A cohort of 20 virtual MV patients based on retrospective patient data are used to validate the performance of this method for volume-controlled (VC) ventilation. A performance evaluation was conducted where the SiVENT and VENT protocols were implemented in 1080 instances each to compare the two protocols and evaluate the difference in reduction of possible MV settings achieved by each. RESULTS From an initial number of 189,000 possible MV setting combinations, the VENT protocol reduced this number to a median of 10,612, achieving a reduction of 94.4% across the cohort. With the integration of the stochastic model component, the SiVENT protocol reduced this number from 189,000 to a median of 9329, achieving a reduction of 95.1% across the cohort. The SiVENT protocol reduces the number of possible combinations provided to the user by more than 1000 combinations as compared to the VENT protocol. CONCLUSIONS Adding a stochastic model component into a model-based approach to selecting MV settings improves the ability of a decision support system to recommend patient-specific MV settings. It specifically considers inter- and intra-patient variability in respiratory elastance and eliminates potentially harmful settings based on clinically recommended pressure thresholds. Clinical input and local protocols can further reduce the number of safe setting combinations. The results for the SiVENT protocol justify further investigation of its prediction accuracy and clinical validation trials.
Collapse
Affiliation(s)
- Jay Wing Wai Lee
- School of Engineering, Monash University Malaysia, Subang Jaya, Selangor Malaysia
| | - Yeong Shiong Chiew
- School of Engineering, Monash University Malaysia, Subang Jaya, Selangor Malaysia
| | - Xin Wang
- School of Engineering, Monash University Malaysia, Subang Jaya, Selangor Malaysia
| | - Mohd Basri Mat Nor
- Kulliyah of Medicine, International Islamic University Malaysia, Kuantan, Malaysia
| | - J. Geoffrey Chase
- Center of Bioengineering, University of Canterbury, Christchurch, New Zealand
| | - Thomas Desaive
- GIGA In-Silico Medicine, University of Liege, Liege, Belgium
| |
Collapse
|