Whitehead JF, Laeseke PF, Periyasamy S, Speidel MA, Wagner MG. In silico simulation of hepatic arteries: An open-source algorithm for efficient synthetic data generation. Med Phys 2023; 50:5505-5517. [PMID: 36950870 PMCID: PMC10517083 DOI: 10.1002/mp.16379] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 02/28/2023] [Accepted: 03/13/2023] [Indexed: 03/24/2023] Open
Abstract
BACKGROUND In silico testing of novel image reconstruction and quantitative algorithms designed for interventional imaging requires realistic high-resolution modeling of arterial trees with contrast dynamics. Furthermore, data synthesis for training of deep learning algorithms requires that an arterial tree generation algorithm be computationally efficient and sufficiently random. PURPOSE The purpose of this paper is to provide a method for anatomically and physiologically motivated, computationally efficient, random hepatic arterial tree generation. METHODS The vessel generation algorithm uses a constrained constructive optimization approach with a volume minimization-based cost function. The optimization is constrained by the Couinaud liver classification system to assure a main feeding artery to each Couinaud segment. An intersection check is included to guarantee non-intersecting vasculature and cubic polynomial fits are used to optimize bifurcation angles and to generate smoothly curved segments. Furthermore, an approach to simulate contrast dynamics and respiratory and cardiac motion is also presented. RESULTS The proposed algorithm can generate a synthetic hepatic arterial tree with 40 000 branches in 11 s. The high-resolution arterial trees have realistic morphological features such as branching angles (MAD with Murray's law= 1.2 ± 1 . 2 o $ = \;1.2 \pm {1.2^o}$ ), radii (median Murray deviation= 0.08 $ = \;0.08$ ), and smoothly curved, non-intersecting vessels. Furthermore, the algorithm assures a main feeding artery to each Couinaud segment and is random (variability = 0.98 ± 0.01). CONCLUSIONS This method facilitates the generation of large datasets of high-resolution, unique hepatic angiograms for the training of deep learning algorithms and initial testing of novel 3D reconstruction and quantitative algorithms designed for interventional imaging.
Collapse
Affiliation(s)
- Joseph F. Whitehead
- Department of Medical Physics, University of Wisconsin – Madison, Madison, WI 53705, USA
| | - Paul F. Laeseke
- Department of Radiology, University of Wisconsin – Madison, Madison, WI 53792, USA
| | - Sarvesh Periyasamy
- Department of Radiology, University of Wisconsin – Madison, Madison, WI 53792, USA
| | - Michael A. Speidel
- Department of Medical Physics, University of Wisconsin – Madison, Madison, WI 53705, USA
- Department of Medicine, University of Wisconsin – Madison, Madison WI 53705, USA
| | - Martin G. Wagner
- Department of Medical Physics, University of Wisconsin – Madison, Madison, WI 53705, USA
- Department of Radiology, University of Wisconsin – Madison, Madison, WI 53792, USA
| |
Collapse
|
2
|
Guo X, Wu J, Chen MK, Liu Q, Onofrey JA, Pucar D, Pang Y, Pigg D, Casey ME, Dvornek NC, Liu C. Inter-pass motion correction for whole-body dynamic PET and parametric imaging. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2023; 7:344-353. [PMID: 37842204 PMCID: PMC10569406 DOI: 10.1109/trpms.2022.3227576] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2023]
Abstract
Whole-body dynamic FDG-PET imaging through continuous-bed-motion (CBM) mode multi-pass acquisition protocol is a promising metabolism measurement. However, inter-pass misalignment originating from body movement could degrade parametric quantification. We aim to apply a non-rigid registration method for inter-pass motion correction in whole-body dynamic PET. 27 subjects underwent a 90-min whole-body FDG CBM PET scan on a Biograph mCT (Siemens Healthineers), acquiring 9 over-the-heart single-bed passes and subsequently 19 CBM passes (frames). The inter-pass motion correction was executed using non-rigid image registration with multi-resolution, B-spline free-form deformations. The parametric images were then generated by Patlak analysis. The overlaid Patlak slope Ki and y-intercept Vb images were visualized to qualitatively evaluate motion impact and correction effect. The normalized weighted mean squared Patlak fitting errors (NFE) were compared in the whole body, head, and hypermetabolic regions of interest (ROI). In Ki images, ROI statistics were collected and malignancy discrimination capacity was estimated by the area under the receiver operating characteristic curve (AUC). After the inter-pass motion correction was applied, the spatial misalignment appearance between Ki and Vb images was successfully reduced. Voxel-wise normalized fitting error maps showed global error reduction after motion correction. The NFE in the whole body (p = 0.0013), head (p = 0.0021), and ROIs (p = 0.0377) significantly decreased. The visual performance of each hypermetabolic ROI in Ki images was enhanced, while 3.59% and 3.67% average absolute percentage changes were observed in mean and maximum Ki values, respectively, across all evaluated ROIs. The estimated mean Ki values had substantial changes with motion correction (p = 0.0021). The AUC of both mean Ki and maximum Ki after motion correction increased, possibly suggesting the potential of enhancing oncological discrimination capacity through inter-pass motion correction.
Collapse
Affiliation(s)
- Xueqi Guo
- Department of Biomedical Engineering, Yale University, New Haven, CT, 06511, USA
| | - Jing Wu
- Department of Biomedical Engineering, Yale University, New Haven, CT, 06511, USA, and the Center for Advanced Quantum Studies and Department of Physics, Beijing Normal University, Beijing, China
| | - Ming-Kai Chen
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06511, USA
| | - Qiong Liu
- Department of Biomedical Engineering, Yale University, New Haven, CT, 06511, USA
| | - John A Onofrey
- Department of Biomedical Engineering, the Department of Radiology and Biomedical Imaging, and the Department of Urology, Yale University, New Haven, CT, 06511, USA
| | - Darko Pucar
- Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06511, USA
| | - Yulei Pang
- Department of Biomedical Engineering, Yale University, New Haven, CT, 06511, USA, and Southern Connecticut State University, New Haven, CT, 06515, USA
| | - David Pigg
- Siemens Medical Solutions USA, Inc., Knoxville, TN, 37932, USA
| | - Michael E Casey
- Siemens Medical Solutions USA, Inc., Knoxville, TN, 37932, USA
| | - Nicha C Dvornek
- Department of Biomedical Engineering and the Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06511, USA
| | - Chi Liu
- Department of Biomedical Engineering and the Department of Radiology and Biomedical Imaging, Yale University, New Haven, CT, 06511, USA
| |
Collapse
|
3
|
Bamneshin K, Rabi Mahdavi S, Bitarafan-Rajabi A, Geramifar P, Hejazi P, Jadidi M. Breathing-induced Errors in Quantification and Description of Dominant Intra-Prostatic Lesions (Dils) in PET Images: A Simulation Study by Means of The 4D NCAT Phantom. J Biomed Phys Eng 2022; 12:497-504. [PMID: 36313408 PMCID: PMC9589085 DOI: 10.31661/jbpe.v0i0.1912-1015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2019] [Accepted: 05/25/2020] [Indexed: 06/16/2023]
Abstract
BACKGROUND Respiratory movement and the motion range of the diaphragm can affect the quality and quantity of prostate images. OBJECTIVE This study aimed to investigate the magnitude of respiratory-induced errors to determine Dominant Intra- prostatic Lesions (DILs) in positron emission tomography (PET) images. MATERIAL AND METHODS In this simulation study, we employed the 4D NURBS-based cardiac-torso (4D-NCAT) phantom with a realistic breathing model to simulate the respiratory cycles of a patient to assess the displacement, volume, maximum standardized uptake value (SUVmax), mean standardized uptake value (SUVmean), signal to noise ratio (SNR), and the contrast of DILs in frames within the respiratory cycle. RESULTS Respiration in a diaphragm motion resulted in the maximum superior-inferior displacement of 3.9 and 6.1 mm, and the diaphragm motion amplitudes of 20 and 35 mm. In a no-motion image, the volume measurement of DILs had the smallest percentage of errors. Compared with the no-motion method, the percentages of errors in the average method in 20 and 35 mm- diaphragm motion were 25% and 105%, respectively. The motion effect was significantly reduced in terms of the values of SUVmax and SUVmean in comparison with the values of SUVmax and SUVmean in no- motion images. The contrast values in respiratory cycle frames were at a range of 3.3-19.2 mm and 6.5-46 for diaphragm movements' amplitudes of 20 and 35 mm. CONCLUSION The respiratory movement errors in quantification and delineation of DILs were highly dependent on the range of motion, while the average method was not suitable to precisely delineate DILs in PET/CT in the dose-painting technique.
Collapse
Affiliation(s)
- Khadijeh Bamneshin
- PhD, Department of Radiology Technology, Faculty of Allied Medical Sciences, Semnan University of Medical Sciences, Semnan, Iran
- PhD, Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Seied Rabi Mahdavi
- PhD, Radiation Biology Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Ahmad Bitarafan-Rajabi
- PhD, Echocardiography Research Center, Rajaie Cardiovascular Medical and Research Center, Iran University of Medical Sciences, Tehran, Iran
| | - Parham Geramifar
- PhD, Department of Nuclear Medicine, Shariati Hospital Tehran University of Medical Sciences, Tehran, Iran
| | - Payman Hejazi
- PhD, Department of Medical Physics, School of Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Majid Jadidi
- PhD, Department of Radiology Technology, Faculty of Allied Medical Sciences, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
4
|
Lamare F, Bousse A, Thielemans K, Liu C, Merlin T, Fayad H, Visvikis D. PET respiratory motion correction: quo vadis? Phys Med Biol 2021; 67. [PMID: 34915465 DOI: 10.1088/1361-6560/ac43fc] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Accepted: 12/16/2021] [Indexed: 11/12/2022]
Abstract
Positron emission tomography (PET) respiratory motion correction has been a subject of great interest for the last twenty years, prompted mainly by the development of multimodality imaging devices such as PET/computed tomography (CT) and PET/magnetic resonance imaging (MRI). PET respiratory motion correction involves a number of steps including acquisition synchronization, motion estimation and finally motion correction. The synchronization steps include the use of different external device systems or data driven approaches which have been gaining ground over the last few years. Patient specific or generic motion models using the respiratory synchronized datasets can be subsequently derived and used for correction either in the image space or within the image reconstruction process. Similar overall approaches can be considered and have been proposed for both PET/CT and PET/MRI devices. Certain variations in the case of PET/MRI include the use of MRI specific sequences for the registration of respiratory motion information. The proposed review includes a comprehensive coverage of all these areas of development in field of PET respiratory motion for different multimodality imaging devices and approaches in terms of synchronization, estimation and subsequent motion correction. Finally, a section on perspectives including the potential clinical usage of these approaches is included.
Collapse
Affiliation(s)
- Frederic Lamare
- Nuclear Medicine Department, University Hospital Centre Bordeaux Hospital Group South, ., Bordeaux, Nouvelle-Aquitaine, 33604, FRANCE
| | - Alexandre Bousse
- LaTIM, INSERM UMR1101, Université de Bretagne Occidentale, ., Brest, Bretagne, 29285, FRANCE
| | - Kris Thielemans
- University College London Institute of Nuclear Medicine, UCL Hospital, Tower 5, 235 Euston Road, London, NW1 2BU, UNITED KINGDOM OF GREAT BRITAIN AND NORTHERN IRELAND
| | - Chi Liu
- Department of Diagnostic Radiology, Yale University School of Medicine Department of Radiology and Biomedical Imaging, PO Box 208048, 801 Howard Avenue, New Haven, Connecticut, 06520-8042, UNITED STATES
| | - Thibaut Merlin
- LaTIM, INSERM UMR1101, Universite de Bretagne Occidentale, ., Brest, Bretagne, 29285, FRANCE
| | - Hadi Fayad
- Weill Cornell Medicine - Qatar, ., Doha, ., QATAR
| | - Dimitris Visvikis
- LaTIM, UMR1101, Universite de Bretagne Occidentale, INSERM, Brest, Bretagne, 29285, FRANCE
| |
Collapse
|
5
|
Johnson PM, Taylor R, Whelan T, Thiessen JD, Anazodo U, Drangova M. Rigid-body motion correction in hybrid PET/MRI using spherical navigator echoes. Phys Med Biol 2019; 64:08NT03. [PMID: 30884475 DOI: 10.1088/1361-6560/ab10b2] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Integrated positron emission tomography and magnetic resonance imaging (PET/MRI) is an imaging technology that provides complementary anatomical and functional information for medical diagnostics. Both PET and MRI are highly susceptible to motion artifacts due, in part, to long acquisition times. The simultaneous acquisition of the two modalities presents the opportunity to use MRI navigator techniques for motion correction of both PET and MRI data. For this task, we propose spherical navigator echoes (SNAVs)-3D k-space navigators that can accurately and rapidly measure rigid body motion in all six degrees of freedom. SNAVs were incorporated into turbo FLASH (tfl)-a product fast gradient echo sequence-to create the tfl-SNAV pulse sequence. Acquiring in vivo brain images from a healthy volunteer with both sequences first compared the tfl-SNAV and product tfl sequences. It was observed that incorporation of the SNAVs into the image sequence did not have any detrimental impact on the image quality. The SNAV motion correction technique was evaluated using an anthropomorphic brain phantom. Following a stationary reference image where the tfl-SNAV sequence was acquired along with simultaneous list-mode PET, three identical PET/MRI scans were performed where the phantom was moved several times throughout each acquisition. This motion-up to 11° and 14 mm-resulted in motion artifacts in both PET and MR images. Following SNAV motion correction of the MRI and PET list-mode data, artifact reduction was achieved for both the PET and MR images in all three motion trials. The corrected images have improved image quality and are quantitatively more similar to the ground truth reference images.
Collapse
Affiliation(s)
- P M Johnson
- Robarts Research Institute, Western University, London, ON, Canada. Department of Medical Biophysics, Western University, London, ON, Canada
| | | | | | | | | | | |
Collapse
|
6
|
Marchesseau S, Totman JJ, Fadil H, Leek FAA, Chaal J, Richards M, Chan M, Reilhac A. Cardiac motion and spillover correction for quantitative PET imaging using dynamic MRI. Med Phys 2019; 46:726-737. [PMID: 30575047 DOI: 10.1002/mp.13345] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2018] [Revised: 12/07/2018] [Accepted: 12/07/2018] [Indexed: 01/01/2023] Open
Abstract
PURPOSE Cardiac positron emission tomography/magnetic resonance imaging (PET/MRI) acquisition presents novel clinical applications thanks to the combination of viability and metabolic imaging (PET) and functional and structural imaging (MRI). However, the resolution of PET, as well as cardiac and respiratory motion in nongated cardiac imaging acquisition protocols, leads to a reduction in image quality and severe quantitative bias. Respiratory or cardiac motion is customarily addressed with gated reconstruction which results in higher noise. METHODS Inspired by a method that has been used in brain PET, a practical correction approach, designed to overcome these existing limitations for quantitative PET imaging, was developed and applied in the context of cardiac PET/MRI. The correction approach for PET data consists of computing the mean density map of each underlying moving region, as obtained with MRI, and translating them to the PET space taking into account the PET spatial and temporal resolution. Using these tissue density maps, the method then constructs a system of linear equations that models the activity recovery and cross-contamination coefficients, which can be solved for the true activity values. Physical and numerical cardiac phantoms were employed in order to quantify the proposed correction. The full correction pipeline was then used to assess differences in metabolic function between scar and healthy myocardium in eight patients with recent acute myocardial infarction using [11 C]-acetate. Data from ten additional patients, injected with [18 F]-FDG, were used to compare the method to the standard electrocardiography (ECG)-gated approach. RESULTS The proposed method resulted in better recovery (from 32% to 95% on the simulated phantom model) and less residual activity than the standard approach. Higher signal-to-noise and contrast-to-noise ratios than ECG-gating were also witnessed (Signal-to-noise ratio (SNR) increased from 2.92 to 5.24, contrast-to-noise ratio (CNR) increased from 62.9 to 145.9 when compared to a four-gate reconstruction). Finally, the relevance of this correction using [11 C]-acetate PET patient data, for which erroneous physiological conclusions could have been made based on the uncorrected data, was established as the correction led to the expected clinical results. CONCLUSIONS An efficient and simple method to correct for the quantitative biases in PET measurements caused by cardiac motion has been developed. Validation experiments using phantom and patient data showed improved accuracy and reliability with this approach when compared to simpler strategies such as gated acquisition or optimal regions of interest (ROI).
Collapse
Affiliation(s)
| | - John J Totman
- Clinical Imaging Research Centre, A*STAR-NUS, 117599, Singapore
| | - Hakim Fadil
- Clinical Imaging Research Centre, A*STAR-NUS, 117599, Singapore
| | | | - Jasper Chaal
- Clinical Imaging Research Centre, A*STAR-NUS, 117599, Singapore
| | - Mark Richards
- Cardiovascular Research Institute, National University of Singapore, 119228, Singapore.,Christchurch Heart Institute, University of Otago, Christchurch, 8140, New Zealand
| | - Mark Chan
- Department of Medicine, Yong Loo Lin SoM, National University of Singapore, 117597, Singapore
| | | |
Collapse
|
7
|
Robson PM, Trivieri M, Karakatsanis NA, Padilla M, Abgral R, Dweck MR, Kovacic JC, Fayad ZA. Correction of respiratory and cardiac motion in cardiac PET/MR using MR-based motion modeling. Phys Med Biol 2018; 63:225011. [PMID: 30426968 DOI: 10.1088/1361-6560/aaea97] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Cardiac positron emission tomography (PET) imaging suffers from image blurring due to the constant motion of the heart that can impact interpretation. Hybrid PET/magnetic resonance (MR) has the potential to use radiation-free MR imaging to correct for the effects of cardio-respiratory motion in the PET data, improving qualitative and quantitative PET imaging in the heart. The purpose of this study was (i) to implement a MR image-based motion-corrected PET/MR method and (ii) to perform a proof-of-concept study of quantitative myocardial PET data in patients. The proposed method takes reconstructions of respiratory and cardiac gated PET data and applies spatial transformations to a single reference frame before averaging to form a single motion-corrected PET (MC-PET) image. Motion vector fields (MVFs) describing the transformations were derived from affine or non-rigid registration of respiratory and cardiac gated MR data. Eight patients with suspected cardiac sarcoidosis underwent cardiac PET/MR imaging after injection of 5 MBq kg-1 of 18F-fluorodeoxyglucose (18F-FDG). Myocardial regions affected by motion were identified by expert readers within which target-to-background ratios (TBR) and contrast-to-noise ratios (CNR) were measured on non-MC-non-gated, MC-PET, and double respiratory and cardiac gated PET images. Paired t-tests were used to determine statistical differences in quantitative uptake-measures between the different types of PET images. MC-PET images showed less blurring compared to non-MC-non-gated PET and tracer activity qualitatively aligned better with the underlying myocardial anatomy when fused with MR. TBR and CNR were significantly greater for MC-PET (2.8 ± 0.9; 21 ± 22) compared to non-MC-non-gated PET (2.4 ± 0.9, p = 0.0001; 15 ± 13, p = 0.02), while TBR was lower and CNR greater compared to double-gated PET (3.2 ± 0.9, p = 0.04; 6 ± 3, p = 0.004). This study demonstrated in a patient cohort that motion-corrected (MC) cardiac PET/MR is feasible using a retrospective MR image-based method and that improvement in TBR and CNR are achievable. MC PET/MR holds promise for improving interpretation and quantification in cardiac PET imaging.
Collapse
Affiliation(s)
- Philip M Robson
- Translational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, One Gustave Levy Pl, New York, NY 10029, United States of America. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Angelis GI, Gillam JE, Kyme AZ, Fulton RR, Meikle SR. Image-based modelling of residual blurring in motion corrected small animal PET imaging using motion dependent point spread functions. Biomed Phys Eng Express 2018. [DOI: 10.1088/2057-1976/aab922] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
9
|
Zaidi H, Karakatsanis N. Towards enhanced PET quantification in clinical oncology. Br J Radiol 2017; 91:20170508. [PMID: 29164924 DOI: 10.1259/bjr.20170508] [Citation(s) in RCA: 73] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Positron emission tomography (PET) has, since its inception, established itself as the imaging modality of choice for the in vivo quantitative assessment of molecular targets in a wide range of biochemical processes underlying tumour physiology. PET image quantification enables to ascertain a direct link between the time-varying activity concentration in organs/tissues and the fundamental parameters portraying the biological processes at the cellular level being assessed. However, the quantitative potential of PET may be affected by a number of factors related to physical effects, hardware and software system specifications, tracer kinetics, motion, scan protocol design and limitations in current image-derived PET metrics. Given the relatively large number of PET metrics reported in the literature, the selection of the best metric for fulfilling a specific task in a particular application is still a matter of debate. Quantitative PET has advanced elegantly during the last two decades and is now reaching the maturity required for clinical exploitation, particularly in oncology where it has the capability to open many avenues for clinical diagnosis, assessment of response to treatment and therapy planning. Therefore, the preservation and further enhancement of the quantitative features of PET imaging is crucial to ensure that the full clinical value of PET imaging modality is utilized in clinical oncology. Recent advancements in PET technology and methodology have paved the way for faster PET acquisitions of enhanced sensitivity to support the clinical translation of highly quantitative four-dimensional (4D) parametric imaging methods in clinical oncology. In this report, we provide an overview of recent advances and future trends in quantitative PET imaging in the context of clinical oncology. The pros/cons of the various image-derived PET metrics will be discussed and the promise of novel methodologies will be highlighted.
Collapse
Affiliation(s)
- Habib Zaidi
- 1 Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital , Geneva , Switzerland.,2 Department of Nuclear Medicine and Molecular Imaging, University of Groningen , Groningen , Netherlands.,3 Geneva Neuroscience Centre, University of Geneva , Geneva , Switzerland.,4 Department of Nuclear Medicine, Universityof Southern Denmark , Odense , Denmark
| | - Nicolas Karakatsanis
- 5 Division of Radiopharmaceutical Sciences, Department of Radiology, Weill Cornell Medical College of Cornell Univercity , New york, NY , USA.,6 Department of Radiology, Translational and Molecular Imaging Institute, ICAHN School of Medicine at Mount Sinai , New york, NY , USA
| |
Collapse
|