Perelló-Capó J, Estadella-Tarriel J, Gich-Saladich I, Bailón-Queiruga M, Llurba-Olivé E, Calaf-Alsina J. Bleeding profile and safety of a levonorgestrel 13.5 mg intrauterine device versus Nova T copper 380 mm
2 intrauterine device: Results of a 3-year, single-center, randomized phase 4 study.
Contraception 2023;
127:110127. [PMID:
37487868 DOI:
10.1016/j.contraception.2023.110127]
[Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 07/19/2023] [Accepted: 07/19/2023] [Indexed: 07/26/2023]
Abstract
OBJECTIVE
To assess the bleeding profiles of the levonorgestrel 13.5 mg intrauterine device (LNG13.5-IUD) and Nova T copper 380 mm2 IUD (Cu380-IUD).
STUDY DESIGN
Single-center, evaluator-masked, randomized study conducted in women aged 18-45 years starting these methods. Primary outcomes were number of bleeding days, self-reported bleeding intensity, Pictorial Blood Assessment Chart (PBAC) score, and blood biochemical values at baseline, months 3, 6, 12, 24, and 36 per 90-day reference periods except for PBAC (months). Secondary objectives were presence/duration/intensity of dysmenorrhea and tolerability.
RESULTS
We included 106 women aged 32.5 ± 6.7 years: 55 with LNG13.5-IUD and 51 with Cu380-IUD. Data for LNG13.5-IUD versus Cu380-IUD at baseline and month 36 (both respectively) were as follows: (1) median (25th; 75th percentile) number of bleeding days: 12 (9.0; 15.0) versus 12 (9.0; 15.0), p = 0.82, and 4 (0; 13.7) versus 15 (14.2; 20.0), p < 0.001; (2) mean bleeding intensity: 1.7 for both, p = 0.66, and 0.7 and 2.2, p < 0.001. Forty percent versus 0% presented with amenorrhea at month 36; (3) mean PBAC score (95% Confidence interval (CI): 50.7 (16.6; 84.7) versus 130.4 (95.7; 165.0) at month 1, and 7.9 (-26.7; 42.6) versus 126 (90.7; 161.2), p < 0.001; (4) median (25th; 75th percentile) ferritin levels (Ug/L) 33 (19; 53) versus 30 (19; 45), p = 0.70, and 59 (42; 84) versus 21 (8; 39). We did not observe changes or differences between groups in hemoglobin and hematocrit. The duration and intensity of dysmenorrhea were significantly lower with LNG13.5-IUD versus Cu380-IUD. Adverse events were those expected.
CONCLUSIONS
LNG13.5-IUD is associated with a significant reduction in blood loss and dysmenorrhea compared with Cu380-IUD.
IMPLICATIONS
Women eligible for a levonorgestrel 13.5 mg intrauterine device (IUD) or a copper 380 mm2 IUD should be informed of the differences in bleeding profiles-one of the main causes for IUD discontinuation-so they can compare this information against their bleeding expectations.
Collapse