1
|
Fan PL, Chu J, Wang Q, Wang C. The clinical value of dual-energy computed tomography and diffusion-weighted imaging in the context of liver cancer: A narrative review. JOURNAL OF CLINICAL ULTRASOUND : JCU 2022; 50:862-868. [PMID: 35338779 DOI: 10.1002/jcu.23197] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 02/22/2022] [Accepted: 03/12/2022] [Indexed: 06/14/2023]
Abstract
The dual-energy computed tomography (DECT) and diffusion-weighted magnetic resonance imaging (DWI-MRI) are used to diagnose liver cancer. The clinical value of these two examination methods needs to be further summarized. We collected and summarized relevant literature published from 2011 to 2021. The diagnostic performance of DECT was assessed between conventional computed tomography and DWI-MRI. DWI-MRI had a 69% sensitivity for detecting small hepatocellular carcinoma (HCC) lesions and a 60% diagnostic specificity for differentiating between types of HCC lesions. DECT had a sensitivity to small liver lesions (<1 cm) of 69%, and the diagnostic specificity for HCC and metastasis was about 60%. DWI was more sensitive (90.3% vs. 74.9%) and accurate (91.9% vs. 76.9%) in diagnosing HCC compared with conventional MRI sequencing. With the aid of contrast media, DWI-MRI had 90.0% specificity for detecting small HCCs (smaller than 1 cm). Furthermore, DWI-MRI not only provided physicians with valuable diagnostic information but also delivered histological grading information, with 78% accuracy for all benign lesions and 71% for solid lesions. DECT had relatively high sensitivity and required a lower contrast medium dose. With standardized quantitative parameters, it can be an extremely useful tool for HCC surveillance. DWI-MRI is the preferred imaging process as it produces high-contrast images for supporting an early diagnosis (high sensitivity and specificity) and provides histological information using non-ionizing radiation.
Collapse
Affiliation(s)
- Pei-Lin Fan
- Discipline of Diagnostic Radiography, University of Sydney, Sydney, Australia
| | - Jun Chu
- Discipline of Diagnostic Radiography, University of Sydney, Sydney, Australia
| | - Qing Wang
- Discipline of Diagnostic Radiography, University of Sydney, Sydney, Australia
| | - Chen Wang
- Discipline of Diagnostic Radiography, University of Sydney, Sydney, Australia
| |
Collapse
|
2
|
Adam SZ, Rabinowich A, Kessner R, Blachar A. Spectral CT of the abdomen: Where are we now? Insights Imaging 2021; 12:138. [PMID: 34580788 PMCID: PMC8476679 DOI: 10.1186/s13244-021-01082-7] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2021] [Accepted: 08/16/2021] [Indexed: 12/14/2022] Open
Abstract
Spectral CT adds a new dimension to radiological evaluation, beyond assessment of anatomical abnormalities. Spectral data allows for detection of specific materials, improves image quality while at the same time reducing radiation doses and contrast media doses, and decreases the need for follow up evaluation of indeterminate lesions. We review the different acquisition techniques of spectral images, mainly dual-source, rapid kV switching and dual-layer detector, and discuss the main spectral results available. We also discuss the use of spectral imaging in abdominal pathologies, emphasizing the strengths and pitfalls of the technique and its main applications in general and in specific organs.
Collapse
Affiliation(s)
- Sharon Z Adam
- Department of Diagnostic Radiology, Tel Aviv Sourasky Medical Center, 6 Weizmann St., 6423906, Tel Aviv, Israel. .,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
| | - Aviad Rabinowich
- Department of Diagnostic Radiology, Tel Aviv Sourasky Medical Center, 6 Weizmann St., 6423906, Tel Aviv, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Rivka Kessner
- Department of Diagnostic Radiology, Tel Aviv Sourasky Medical Center, 6 Weizmann St., 6423906, Tel Aviv, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Arye Blachar
- Department of Diagnostic Radiology, Tel Aviv Sourasky Medical Center, 6 Weizmann St., 6423906, Tel Aviv, Israel.,Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
3
|
Laroia ST, Yadav K, Kumar S, Rastogi A, Kumar G, Sarin SK. Material decomposition using iodine quantification on spectral CT for characterising nodules in the cirrhotic liver: a retrospective study. Eur Radiol Exp 2021; 5:22. [PMID: 34046753 PMCID: PMC8160046 DOI: 10.1186/s41747-021-00220-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2020] [Accepted: 04/07/2021] [Indexed: 12/15/2022] Open
Abstract
Background There is limited scientific evidence on the potential of spectral computed tomography (SCT) for differentiation of nodules in the cirrhotic liver. We aimed to assess SCT-generated material density (MD) parameters for nodule characterisation in cirrhosis. Methods Dynamic dual-energy SCT scans of cirrhotic patients performed over 3 years were retrospectively reviewed. They were classified as hepatocellular carcinoma (HCC), regenerative or indeterminate, according to the European Association for the Study of the Liver criteria. MD maps were generated to calculate the area under the curve (AUC) and cutoff values to discriminate these nodules in the hepatic arterial phase (HAP) and portal venous phase (PVP). MD maps included iodine concentration density (ICD) of the liver and nodule, lesion-to-normal liver ICD ratio (LNR) and difference in nodule ICD between HAP and PVP. Results Three hundred thirty nodules belonging to 300 patients (age 53.0 ± 12.7 years, mean ± standard deviation) were analysed at SCT (size 2.3 ± 0.8 cm, mean ± SD). One hundred thirty-three (40.3%) nodules were classified as HCC, 147 (44.5%) as regenerative and 50 (15.2%) as indeterminate. On histopathology, 136 (41.2%) nodules were classified as HCC, 183 (55.5%) as regenerative and 11 (3.3%) as dysplastic. All MD parameters on HAP and the nodule difference in ICD could discriminate pathologically proven HCC or potentially malignant nodules from regenerative nodules (p < 0.001). The AUC was 82.4% with a cutoff > 15.5 mg/mL for nodule ICD, 81.3% > 1.8 for LNR-HAP and 81.3% for difference in ICD > 3.5 mg/mL. Conclusion SCT-generated MD parameters are viable diagnostic tools for differentiating malignant or potentially malignant from benign nodules in the cirrhotic liver. Supplementary Information The online version contains supplementary material available at 10.1186/s41747-021-00220-6.
Collapse
Affiliation(s)
- Shalini Thapar Laroia
- Department of Radiology, Institute of Liver and Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi, 110070, India.
| | - Komal Yadav
- Department of Radiology, Institute of Liver and Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi, 110070, India
| | - Senthil Kumar
- Department of HPB Surgery and Liver Transplantation, Institute of Liver & Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi, 110070, India
| | - Archana Rastogi
- Department of Clinical and Hepato-pathology, Institute of Liver and Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi, 110070, India
| | - Guresh Kumar
- Department of Biostatistics and Research, Institute of Liver & Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi, 110070, India
| | - Shiv Kumar Sarin
- Department of Hepatology, Institute of Liver & Biliary Sciences, Sector D-1, Vasant Kunj, New Delhi, 110 070, India
| |
Collapse
|
4
|
Spectral CT in clinical routine imaging of neuroendocrine neoplasms. Clin Radiol 2021; 76:348-357. [PMID: 33610290 DOI: 10.1016/j.crad.2020.12.027] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Accepted: 12/24/2020] [Indexed: 12/14/2022]
Abstract
AIM To evaluate the potential of new spectral computed tomography (SCT)-based tools in patients with neuroendocrine neoplasms (NEN). MATERIAL AND METHODS Eighty-eight consecutive patients with NENs were included prospectively. The patients underwent multiphase CT with spectral and standard mode. The signal-to-noise ratio (SNR)/contrast-to-noise-ratio (CNR)tumour-to-liver, iodine concentrations (ICs, total tumour/hotspot) and attenuation slopes in virtual monochromatic images (VMIs) were used to assess NEN-specific SCT values in primary tumours and metastatic lesions and investigate a possible lesion contrast improvement as well as possible correlations of SCT parameters to primary tumour location and tumour grade. Furthermore, the usability of SCT parameters to differentiate between the primary tumour and metastatic lesions, and to predict tumour response after 6-months follow-up was analyzed. The applied dose of spectral and standard mode was compared intra-individually. RESULTS SNR/CNRtumour-to-liver significantly increased in low-energy VMIs. NENs showed significant differences in ICs between primary and metastatic lesions for both absolute and normalised values (p<0.001) regardless of whether the total tumour or the hotspot was measured. There was also a significant difference in the attenuation slope (p<0.001). No significant correlations were found between SCT and tumour grade. A tumour response prediction by SCT parameters was not possible. The applied dose was comparable between the scan modes. CONCLUSION SCT was comparable regarding applied dose, improved tumour contrast, and contributed to differentiation between primary NEN and metastasis.
Collapse
|
5
|
|
6
|
Morgan DE. The Role of Dual-Energy Computed Tomography in Assessment of Abdominal Oncology and Beyond. Radiol Clin North Am 2018; 56:565-585. [PMID: 29936948 DOI: 10.1016/j.rcl.2018.03.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
The added value and strength of dual energy computed tomography for the evaluation of oncologic patients revolve around the use of lower energy reconstructed images and iodine material density images. Lower keV simulated monoenergetic images optimize soft tissue tumor to nontumoral attenuation differences and increase contrast to noise ratios to improve lesion detection. Iodine material density images or maps are helpful from a qualitative standpoint for image interpretation because they result in improved detection and characterization of tumors and lymph node involvement, and from a quantitative assessment by enabling interrogation of specific properties of tissues to predict and assess therapeutic response.
Collapse
Affiliation(s)
- Desiree E Morgan
- Department of Radiology University of Alabama at Birmingham, 619 19th Street South, JTN 456, Birmingham, AL 35249-6830, USA.
| |
Collapse
|
7
|
Mahmood U, Horvat N, Horvat JV, Ryan D, Gao Y, Carollo G, DeOcampo R, Do RK, Katz S, Gerst S, Schmidtlein CR, Dauer L, Erdi Y, Mannelli L. Rapid switching kVp dual energy CT: Value of reconstructed dual energy CT images and organ dose assessment in multiphasic liver CT exams. Eur J Radiol 2018; 102:102-108. [PMID: 29685522 DOI: 10.1016/j.ejrad.2018.02.022] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2017] [Revised: 01/13/2018] [Accepted: 02/14/2018] [Indexed: 01/14/2023]
Abstract
PURPOSE Clinical applications of dual energy computed tomography (DECT) have been widely reported; however, the importance of the different image reconstructions and radiation organ dose remains a relevant area of investigation, particularly considering the different commercially available DECT equipment. Therefore, the purpose of this study was to assess the image reliability and compare the information content between several image reconstructions in a rapid-switching DECT (rsDECT), and assess radiation organ dose between rsDECT and conventional single-energy computed tomography (SECT) exams. MATERIALS AND METHODS This Institutional Review Board-approved retrospective study included 98 consecutive patients who had a history of liver cancer and underwent multiphasic liver CT exams with rsDECT applied during the late arterial phase between June 2015 and December 2015. Virtual monochromatic 70 keV, material density images (MDI) iodine (-water) and virtual unenhanced (VUE) images were generated. Radiation dose analysis was performed in a subset of 44 patients who had also undergone a multiphasic SECT examination within 6 months of the rsDECT. Four board-certified abdominal radiologists reviewed 24-25 patients each, and a fifth radiologist re-evaluated all the scans to reach a consensus. The following imaging aspects were assessed by the radiologists: (a) attenuation measurements were made in the liver and spleen in VUE and true unenhanced (TUE) images; (b) subjective evaluation for lesion detection and conspicuity on MDI iodine (-water)/VUE images compared with the virtual monochromatic images/TUE images; and (c) overall image quality using a five-point Likert scale. The radiation dose analyses were evaluated in the subset of 44 patients regarding the following parameters: CTDIvol, dose length product, patient's effective diameter and organ dose using a Monte Carlo-based software, VirtualDose™ (Virtual Phantoms, Inc.) to 21 organs. RESULTS On average, image noise on the TUE images was 49% higher within the liver (p < 0.0001) and 48% higher within the spleen (p < 0.0001). CT numbers for the spleen were significantly higher on VUE images (p < 0.0001). Twenty-eight lesions in 24/98 (24.5%) patients were not observed on the VUE images. The conspicuity of vascular anatomy was considered better on MDI iodine (-water) Images 26.5% of patients. Using the Likert scale, the rsDECT image quality was considered to be satisfactory. Considering the subset of 44 patients with recent SECT, the organ dose was, on average, 37.4% less with rsDECT. As the patient's effective diameter decreased, the differences in dose between the rsDECT and SECT increased, with the total average organ dose being less by 65.1% when rsDECT was used. CONCLUSION VUE images in the population had lower image noise than TUE images; however, a few small and hyperdense findings were not characterized on VUE images. Delineation of vascular anatomy was considered better in around a quarter of patients on MDI iodine (-water) images. Finally, radiation dose, particularly organ dose, was found to be lower with rsDECT, especially in smaller patients.
Collapse
Affiliation(s)
- Usman Mahmood
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - Natally Horvat
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - Joao Vicente Horvat
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - Davinia Ryan
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - Yiming Gao
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - Gabriella Carollo
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - Rommel DeOcampo
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - Richard K Do
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - Seth Katz
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - Scott Gerst
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - C Ross Schmidtlein
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - Lawrence Dauer
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA; Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - Yusuf Erdi
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| | - Lorenzo Mannelli
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA.
| |
Collapse
|
8
|
Toia GV, Kim S, Dighe MK, Mileto A. Dual-Energy Computed Tomography in Body Imaging. Semin Roentgenol 2018; 53:132-146. [PMID: 29861005 DOI: 10.1053/j.ro.2018.02.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Affiliation(s)
- Giuseppe V Toia
- Body Imaging Section, Department of Radiology, University of Washington School of Medicine, Seattle, WA 98195
| | - Sooah Kim
- Body Imaging Section, Department of Radiology, University of Washington School of Medicine, Seattle, WA 98195
| | - Manjiri K Dighe
- Body Imaging Section, Department of Radiology, University of Washington School of Medicine, Seattle, WA 98195
| | - Achille Mileto
- Body Imaging Section, Department of Radiology, University of Washington School of Medicine, Seattle, WA 98195.
| |
Collapse
|
9
|
ACR Appropriateness Criteria ® Chronic Liver Disease. J Am Coll Radiol 2017; 14:S391-S405. [DOI: 10.1016/j.jacr.2017.08.045] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2017] [Accepted: 08/23/2017] [Indexed: 02/07/2023]
|
10
|
Ahmad M, Fahrig R, Pung L, Spahn M, Köster NS, Reitz S, Moore T, Choi JH, Hinshaw W, Xia Y, Müller K. Assessment of a photon-counting detector for a dual-energy C-arm angiographic system. Med Phys 2017; 44:5938-5948. [DOI: 10.1002/mp.12517] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2016] [Revised: 06/18/2017] [Accepted: 08/05/2017] [Indexed: 11/08/2022] Open
Affiliation(s)
- Moiz Ahmad
- The University of Texas McGovern Medical School; Houston TX USA
| | - Rebecca Fahrig
- Radiological Sciences Lab; Stanford University; Stanford CA USA
- Siemens Healthcare GmbH; Forchheim Germany
| | - Leland Pung
- Siemens Medical Solutions Inc.; Malvern PA USA
| | | | | | | | - Teri Moore
- Siemens Medical Solutions Inc.; Malvern PA USA
| | - Jang-Hwan Choi
- Radiological Sciences Lab; Stanford University; Stanford CA USA
- Division of Mechanical and Biomedical Engineering; Ewha Womans University; Seoul South Korea
| | - Waldo Hinshaw
- Radiological Sciences Lab; Stanford University; Stanford CA USA
| | - Yan Xia
- Radiological Sciences Lab; Stanford University; Stanford CA USA
| | - Kerstin Müller
- Radiological Sciences Lab; Stanford University; Stanford CA USA
- Siemens Healthcare GmbH; Forchheim Germany
| |
Collapse
|
11
|
Imaging of HCC-Current State of the Art. Diagnostics (Basel) 2015; 5:513-45. [PMID: 26854169 PMCID: PMC4728473 DOI: 10.3390/diagnostics5040513] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Revised: 11/16/2015] [Accepted: 11/19/2015] [Indexed: 12/17/2022] Open
Abstract
Early diagnosis of hepatocellular carcinoma (HCC) is crucial for optimizing treatment outcome. Ongoing advances are being made in imaging of HCC regarding detection, grading, staging, and also treatment monitoring. This review gives an overview of the current international guidelines for diagnosing HCC and their discrepancies as well as critically summarizes the role of magnetic resonance imaging (MRI) and computed tomography (CT) techniques for imaging in HCC. The diagnostic performance of MRI with nonspecific and hepatobililiary contrast agents and the role of functional imaging with diffusion-weighted imaging will be discussed. On the other hand, CT as a fast, cheap and easily accessible imaging modality plays a major role in the clinical routine work-up of HCC. Technical advances in CT, such as dual energy CT and volume perfusion CT, are currently being explored for improving detection, characterization and staging of HCC with promising results. Cone beam CT can provide a three-dimensional analysis of the liver with tumor and vessel characterization comparable to cross-sectional imaging so that this technique is gaining an increasing role in the peri-procedural imaging of HCC treated with interventional techniques.
Collapse
|