Hussain LA, Dickens SH, Bowen RL. Properties of eight methacrylated beta-cyclodextrin composite formulations.
Dent Mater 2005;
21:210-6. [PMID:
15705427 DOI:
10.1016/j.dental.2004.03.007]
[Citation(s) in RCA: 20] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2003] [Accepted: 03/31/2004] [Indexed: 10/26/2022]
Abstract
OBJECTIVES
Methacrylated beta-cyclodextrins (MCDs) are novel candidate dental monomers if all or some of the hydroxyl groups of beta-cyclodextrin are substituted with methacrylate groups. The main objective of this study was to evaluate mechanical properties of a number of composite formulations having MCDs as novel dental comonomers. The properties determined were flexural strength (FS), volumetric shrinkage (VS), and degree of conversion (DC).
METHODS
A mass fraction of 50% of MCD monomers was mixed with a mass fraction of 50% each of a series of dimethacrylate or monomethacrylate diluent comonomers to produce consistent formulations of a workable viscosity. For comparison a resin mixture of a mass fraction of 50% Bis-GMA and a mass fraction of 50% triethyleneglycol dimethacrylate (a typical dental resin mixture) was also studied. The mixtures were activated with camphorquinone and ethyl 4-dimethylamino benzoate. One part by mass of each activated resin formulation was mixed with three parts by mass of glass filler. Samples for the FS tests were prepared in (2 x 2 x 25) mm3 molds by light-curing the composites for 2 min on each side. The cured samples were immersed in 37 degrees C water for 24 h, and FS was measured with an Instron machine at a crosshead speed of 0.5 mm/min. VS was measured by a computer-controlled mercury dilatometer. DC was measured by near-infrared spectroscopy.
RESULTS
The properties of the MCD-based composites depended on the kind of diluent used. With these MCD monomers, diluents of triethyleneglycol dimethacrylate, 1,10-decamethylenediol dimethacrylate, or benzyl methacrylate yielded the best composite properties.
SIGNIFICANCE
Although not yet fully optimized, MCD-based composite formulations containing triethyleneglycol dimethacrylate, 1,10-decamethylenediol dimethacrylate, or benzyl methacrylate yielded flexural strength and volumetric shrinkage values were comparable to those of the Bis-GMA/triethyleneglycol dimethacrylate controls. These findings lend support for further development and evaluations of polymerizable cyclodextrin derivatives for use in dental materials.
Collapse