1
|
Musa DB, Ereifej NS. The influence of core-build up materials on biaxial flexural strength of monolithic strength-gradient zirconia; an in-vitro study. BMC Oral Health 2023; 23:873. [PMID: 37978509 PMCID: PMC10657006 DOI: 10.1186/s12903-023-03635-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Accepted: 11/08/2023] [Indexed: 11/19/2023] Open
Abstract
BACKGROUND Since their introduction, there has been limited research regarding the mechanical properties of novel strength-gradient monolithic zirconia. In addition to that, studies evaluating the effect of different core-build materials on the strength of indirect restorations are scarce. Therefore, the aim of this study was to investigate the effect of using different core build-up materials on biaxial flexural strength of a new monolithic multilayered zirconia material. METHODS Forty zirconia discs were fabricated from IPS e.max ZirCAD Prime (Ivoclar Vivadent AG, Schaan, Liechtenstein) and divided into 2 groups (n = 20). Forty composite discs were prepared from Tetric N-Ceram (Ivoclar Vivadent AG, Schaan, Liechtenstein) and MultiCore Flow (Ivoclar Vivadent AG, Schaan, Liechtenstein). The zirconia discs were adhesively cemented to the 2 types of composite forming 2 groups (Zirconia-Tetric N-Ceram and Zirconia-MultiCore Flow). Biaxial flexural strength was determined using a piston-on-3-ball test. The data were statistically analyzed with an independent t-test for significant differences (p = 0.05). RESULTS Tetric N-Ceram had significantly higher strength than MultiCore Flow (p < 0.001) but no statistically significant differences were found in strength values between Zirconia-Tetric N-Ceram and Zirconia-MultiCore Flow bilayered samples (p = 0.27). CONCLUSIONS It was concluded that although the tested composite core materials significantly differ in their biaxial flexural strength values, they had no influence on the biaxial flexural strength of the overlying zirconia.
Collapse
Affiliation(s)
| | - Nadia S Ereifej
- Department of Prosthetic Dentistry, Faculty of Dentistry, The University of Jordan, Queen Rania Street, Amman, 11942, Jordan.
| |
Collapse
|
2
|
Fatigue degradation of bilayered ceramic structures under different biaxial loading schemes. J Mech Behav Biomed Mater 2020; 104:103651. [PMID: 32174409 DOI: 10.1016/j.jmbbm.2020.103651] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2019] [Revised: 01/21/2020] [Accepted: 01/21/2020] [Indexed: 11/22/2022]
|
3
|
Miranda JS, Barcellos ASDP, Campos TMB, Cesar PF, Amaral M, Kimpara ET. Effect of repeated firings and staining on the mechanical behavior and composition of lithium disilicate. Dent Mater 2020; 36:e149-e157. [PMID: 32061444 DOI: 10.1016/j.dental.2020.02.003] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2019] [Revised: 09/02/2019] [Accepted: 02/04/2020] [Indexed: 11/17/2022]
Abstract
OBJECTIVE To evaluate the composition, flexural strength and fatigue behaviour of lithium disilicate ceramic (LD) after repeated firings and different staining techniques. METHODS LD discs were fabricated and divided according to number of firing cycles and staining technique: CO - control, discs were crystallized (850°C/10min); SC - single-step characterization - crystallization and staining (applied with a thin brush) were performed in a single step with one firing cycle (850°C/10min); and DC - double-step characterization - crystallization firing cycle was performed first (850°C/10min), followed by staining firing cycle (770°C/90s). Specimens were fired two, four or six times (one crystallization firing cycle and one, three or five staining firing cycles), resulting into 9 groups (n=30): COII, COIV, COVI, SCII, SCIV, SCVI, DCII, DCIV and DCVI. The composition of the specimens was investigated (EDS, XRD, Raman spectroscopy), and the biaxial flexural strength (n=10) and staircase tests (n=20, 5×104 cycles, 5Hz) were performed. Data were subjected to one-way ANOVA and Tukey's test (α=0.05). RESULTS EDS and XRD revealed amorphous content for stained groups. Biaxial flexural strength was not affected by repeated firings in any group, but stained groups presented lower flexural strength than control groups (p=0.001). The fatigue limit results decreased in all groups compared to flexural strength. SC groups showed similar (SCII and SCIV) or even higher fatigue limits (SCVI) than the control groups, and DC showed the lowest fatigue limit values. SEM and Raman suggested that the interfaces between staining and the LD showed only an overlap for the DC groups, whereas for the SC it was suggested an interaction between the stain and the LD. SIGNIFICANCE Repeated firings did not result in decreased lithium disilicate flexural strength.Staining affected flexural strength and also resulted in increased amorphous content in the characterized specimens. Single-step staining resulted in the highest fatigue limit.
Collapse
Affiliation(s)
- Jean Soares Miranda
- Institute of Science and Technology, UNESP - Paulista State University, São José dos Campos, São Paulo, Brazil
| | | | | | | | - Marina Amaral
- Department of Dentistry, University of Taubaté, Taubaté, São Paulo, Brazil
| | - Estevão Tomomitsu Kimpara
- Institute of Science and Technology, UNESP - Paulista State University, São José dos Campos, São Paulo, Brazil.
| |
Collapse
|
4
|
Tangsatchatham S, Juntavee N. Flexural strength of various types of computerized machinable ceramic veneered to yttria stabilized tetragonal zirconia polycrystalline ceramic upon different hybridized techniques. Clin Cosmet Investig Dent 2019; 11:61-71. [PMID: 31118822 PMCID: PMC6498980 DOI: 10.2147/ccide.s196297] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2018] [Accepted: 02/13/2019] [Indexed: 11/29/2022] Open
Abstract
Objective: This study determined biaxial flexural strength (BFS) of computer-aided design/computer-aided manufacturing (CAD/CAM) ceramic veneered yttria-stabilized tetragonal zirconia poly-crystalline (Y-TZP) related with hybridization techniques and veneering materials. Material and methods: One hundred and twenty zirconia Y-TZP (0.8 mm thick and 12 mm in diameter) were prepared and randomly divided into eight groups, to be conjugated with different veneering ceramics: Vitabloc (Vm), e.max-CAD (Em), Vita-Suprinity (Vs) and Celtra-Duo (Cd), using different hybridized techniques, CAD-bonded (Cb) versus CAD-fused (Cf). BFS was determined using piston on three balls and analyzed for Weilbull reliability. An analysis of variance (ANOVA) and Bonferroni’s multiple comparisons were determined for significant differences. Microscopic structures were examined with scanning electron microscope (SEM), along with X-ray diffraction (XRD). Results: BFS (mean±sd; MPa), Weibull modulus (m), and characteristic strength (σo) of each group were 630.46±65.08, 10.72, and 659.47 for VmCb, 709.03±102.88, 7.67, and 753.03 for VmCf, 651.83±69.48, 9.47, and 685.82 for EmCb, 721.17±121.28, 5.99, and 777.04 for EmCf, 692.83±89.10, 8.56, and 731.87 for VsCb, 888.61±164.26, 5.80, and 959.08 for VsCf, 687.17±59.39, 12.85, and 713.95 for CdCb, and 953.12±134.30, 7.97, and 1010.65 for CdCf. The BFS of ceramic veneered zirconia were significantly affected by different veneering ceramics, hybridized techniques, and their interactions (p<0.05). Cd showed highest BFS, followed by Vs, Em and Vm respectively. Both Cd and Vs showed significant higher BFS than Em and VM (p<0.05). No significant difference of BFS between Cd and Vs and between Em and Vm were indicated (p>0.05). Cf technique showed significantly higher impact on BFS than Cb (p<0.05). Veneering zirconia with either Cd or Vs using Cf technique revealed significantly higher flexural strength than others combinations (p<0.05). Conclusions: Type of veneering ceramics and hybridization techniques affected BFS of ceramic veneered Y-TZP. Veneering zirconia with either Cd or Vs using Cf-process produced superior BFS.
Collapse
Affiliation(s)
- Siripim Tangsatchatham
- Division of Biomaterial and Prosthodontic Research, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| | - Niwut Juntavee
- Department of Prosthodontics, Faculty of Dentistry, Khon Kaen University, Khon Kaen, Thailand
| |
Collapse
|
5
|
Toyama DY, Alves LMM, Ramos GF, Campos TMB, de Vasconcelos G, Borges ALS, de Melo RM. Bioinspired silica-infiltrated zirconia bilayers: Strength and interfacial bonding. J Mech Behav Biomed Mater 2019; 89:143-149. [DOI: 10.1016/j.jmbbm.2018.09.013] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2018] [Revised: 08/24/2018] [Accepted: 09/11/2018] [Indexed: 01/12/2023]
|
6
|
Sawada T, Wagner V, Schille C, Spintzyk S, Schweizer E, Geis-Gerstorfer J. Effect of slow-cooling protocol on biaxial flexural strengths of bilayered porcelain-ceria-stabilized zirconia/alumina nanocomposite (Ce-TZP/A) disks. Dent Mater 2018; 35:270-282. [PMID: 30522698 DOI: 10.1016/j.dental.2018.11.024] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2018] [Revised: 11/13/2018] [Accepted: 11/15/2018] [Indexed: 10/27/2022]
Abstract
OBJECTIVE The present study investigated the biaxial flexural strengths of bilayered ceria-stabilized zirconia/alumina nanocomposite (Ce-TZP/A) disks with various layering porcelains veneered using a slow-cooling protocol. METHODS Five porcelain materials (VITA VM9, Cercon Ceram Kiss, and Vintage ZR with experimental coefficient of thermal expansions; CTEs of 8.45, 9.04, and 9.61ppm/°C) were veneered on Ce-TZP/A disks and slow-cooled after firing to fabricate bilayered specimens (core-to-porcelain thickness: 0.8mm/1.5mm). Biaxial flexural strengths of the specimens with the porcelain layer in tension were tested based on the piston-on-three-ball method (ISO 6872:2008). The data were statistically analyzed using Weibull distribution and Fisher's exact test. RESULTS Tensile stresses were observed in the entire porcelain layer while compressive stress at the surface of the Ce-TZP/A layer shifted to tensile stress at the interface between the materials. The cases of small CTE mismatches between the materials showed high Weibull characteristic strengths at the internal and external surfaces of the specimens, except the VM9 group (CTE: 9.0-9.2ppm/°C). The maximum tensile stress was observed on the surface of the porcelain layer, where cracks originated and continuously propagated into the Ce-TZP layer. The Ce-TZP/A fractured into two pieces for large CTE mismatches between the materials, resulting in significantly lower flexural strengths than those fracturing into three pieces for small CTE mismatches. SIGNIFICANCE Flexural strengths and fracture behaviors of bilayered porcelain-Ce-TZP/A disks were influenced by the CTE mismatches, and a small CTE mismatch between the materials was preferred when using a slow-cooling protocol.
Collapse
Affiliation(s)
- Tomofumi Sawada
- Section Medical Materials Science & Technology, University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany; Department of Biomedical Engineering, Iwate Medical University, 2-1-1 Nishitokuta, Yahaba-cho, Shiwa-gun, Iwate 028-3694, Japan.
| | - Verena Wagner
- Section Medical Materials Science & Technology, University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany.
| | - Christine Schille
- Section Medical Materials Science & Technology, University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany.
| | - Sebastian Spintzyk
- Section Medical Materials Science & Technology, University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany.
| | - Ernst Schweizer
- Section Medical Materials Science & Technology, University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany.
| | - Jürgen Geis-Gerstorfer
- Section Medical Materials Science & Technology, University Hospital Tübingen, Osianderstr. 2-8, 72076 Tübingen, Germany.
| |
Collapse
|
7
|
Sawada T, Schille C, Wagner V, Spintzyk S, Schweizer E, Geis-Gerstorfer J. Biaxial flexural strength of the bilayered disk composed of ceria-stabilized zirconia/alumina nanocomposite (Ce-TZP/A) and veneering porcelain. Dent Mater 2018; 34:1199-1210. [DOI: 10.1016/j.dental.2018.05.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Revised: 01/17/2018] [Accepted: 05/02/2018] [Indexed: 10/16/2022]
|
8
|
Pradíes G, Godoy-Ruiz L, Özcan M, Moreno-Hay I, Martínez-Rus F. Analysis of Surface Roughness, Fracture Toughness, and Weibull Characteristics of Different Framework-Veneer Dental Ceramic Assemblies after Grinding, Polishing, and Glazing. J Prosthodont 2017; 28:e216-e221. [DOI: 10.1111/jopr.12653] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/30/2017] [Indexed: 11/30/2022] Open
Affiliation(s)
- Guillermo Pradíes
- Department of Buccofacial Prostheses; University Complutense of Madrid; Spain
| | - Laura Godoy-Ruiz
- Department of Buccofacial Prostheses; University Complutense of Madrid; Spain
| | - Mutlu Özcan
- Dental Materials Unit, Center for Dental and Oral Medicine, Clinic for Fixed and Removable Prosthodontics and Dental Materials Science; University of Zürich; Switzerland
| | - Isabel Moreno-Hay
- Orofacial Pain Clinic; University of Kentucky College of Dentistry; Lexington KY
| | | |
Collapse
|
9
|
ADM guidance-Ceramics: all-ceramic multilayer interfaces in dentistry. Dent Mater 2017; 33:585-598. [DOI: 10.1016/j.dental.2017.03.005] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Accepted: 03/09/2017] [Indexed: 11/30/2022]
|
10
|
Jian YT, Tang TY, Swain MV, Wang XD, Zhao K. Effect of core ceramic grinding on fracture behaviour of bilayered zirconia veneering ceramic systems under two loading schemes. Dent Mater 2016; 32:1453-1463. [PMID: 27692707 DOI: 10.1016/j.dental.2016.06.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2015] [Revised: 03/25/2016] [Accepted: 06/16/2016] [Indexed: 11/16/2022]
Abstract
OBJECTIVE The aim of this in vitro study was to evaluate the effect of core ceramic grinding on the fracture behaviour of bilayered zirconia under two loading schemes. METHODS Interfacial surfaces of sandblasted zirconia disks (A) were ground with 80 (B), 120 (C) and 220 (D) grit diamond discs, respectively. Surface roughness and topographic analysis were performed using a confocal scanning laser microscope (CSLM) and a scanning electron microscopy (SEM). Relative monoclinic content was evaluated using X-ray diffraction analysis (XRD) then reevaluated after simulated veneer firing. Biaxial fracture strength (σ) and Weibull modulus (m) were calculated either with core in compression (subgroup Ac-Dc) or in tension (subgroup At-Dt). Facture surfaces were examined by SEM and energy dispersive X-ray spectroscopy (EDS). Maximum tensile stress at fracture was estimated by finite element analysis. Statistical data analysis was performed using Kruskal-Wallis and one-way ANOVA at a significance level of 0.05. RESULTS As grit size of the diamond disc increased, zirconia surface roughness decreased (p<0.001). Thermal veneering treatment reversed the transformation of monoclinic phase observed after initial grinding. No difference in initial (p=0.519 for subgroups Ac-Dc) and final fracture strength (p=0.699 for subgroups Ac-Dc; p=0.328 for subgroups At-Dt) was found among the four groups for both loading schemes. While coarse grinding slightly increased final fracture strength reliability (m) for subgroups Ac-Dc. Two different modes of fracture were observed according to which material was on the bottom surface. Components of the liner porcelain remained on the zirconia surface after fracture for all groups. SIGNIFICANCE Technician grinding changed surface topography of zirconia ceramic material, but was not detrimental to the bilayered system strength after veneer application. Coarse grinding slightly improved the fracture strength reliability of the bilayered system tested with core in compression. It is recommended that veneering porcelain be applied directly after routine lab grinding of zirconia ceramic, and its application on rough zirconia cores may be preferred to enhance bond strength.
Collapse
Affiliation(s)
- Yu-Tao Jian
- Institute of Stomatological Research, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Tian-Yu Tang
- Department of Prosthodontics, Affiliated Stomatology Hospital of Kunming Medical University, Kunming, China
| | - Michael V Swain
- Biomaterials Unit, Faculty of Dentistry, University of Sydney, Sydney, NSW, Australia
| | - Xiao-Dong Wang
- Department of Prosthodontics, Guanghua School of Stomatology, Sun Yat-sen University; Guangdong Engineering Research Center of Technology and Materials for Oral Reconstruction, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Ke Zhao
- Department of Prosthodontics, Guanghua School of Stomatology, Sun Yat-sen University; Guangdong Engineering Research Center of Technology and Materials for Oral Reconstruction, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China.
| |
Collapse
|
11
|
Tanaka CB, Harisha H, Baldassarri M, Wolff MS, Tong H, Meira JB, Zhang Y. Experimental and finite element study of residual thermal stresses in veneered Y-TZP structures. CERAMICS INTERNATIONAL 2016; 42:9214-9221. [PMID: 27087734 PMCID: PMC4831075 DOI: 10.1016/j.ceramint.2016.03.018] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The main complications of zirconia-based laminated systems are chipping and delamination of veneering porcelain, which has been found to be directly associated with the development of residual thermal stresses in the porcelain layer. This study investigates the effects of cooling rate and specimen geometry on the residual stress states in porcelain-veneered zirconia structures. Bilayers of three different shapes (bars, semi-cylindrical shells, and arch-cubic structures) with 1.5 mm and 0.7 mm thickness of dentin porcelain and zirconia framework, respectively, were subjected to two cooling protocols: slow cooling (SC) at 32 °C/min and extremely-slow cooling (XSC) at 2 °C/min. The residual thermal stresses were determined using the Vickers indentation method and validated by finite element analysis. The residual stress profiles were similar among geometries in the same cooling protocol. XSC groups presented significantly higher tensile stresses (p = 0.000), especially for curved interfaces. XSC is a time-consuming process that showed no beneficial effect regarding residual stresses compared to the manufacturer recommended slow cooling rate.
Collapse
Affiliation(s)
- Carina B. Tanaka
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 First Avenue, New York, NY 10010, USA
- Department of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Hossam Harisha
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 First Avenue, New York, NY 10010, USA
| | - Marta Baldassarri
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 First Avenue, New York, NY 10010, USA
| | - Mark S. Wolff
- Department of Cariology and Comprehensive Care, Associate Dean for Pre-doctoral Clinical Education, New York University College of Dentistry, 345 East 24th Street, New York, NY 10010, USA
| | - Hui Tong
- School of Metallurgy and Environment, Central South University, Changsha, Hunan 410083, PR China
| | - Josete B.C. Meira
- Department of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Yu Zhang
- Department of Biomaterials and Biomimetics, New York University College of Dentistry, 433 First Avenue, New York, NY 10010, USA
| |
Collapse
|
12
|
Bankoğlu Güngör M, Yılmaz H, Karakoca Nemli S, Turhan Bal B, Aydın C. Effect of surface treatments on the biaxial flexural strength, phase transformation, and surface roughness of bilayered porcelain/zirconia dental ceramics. J Prosthet Dent 2015; 113:585-95. [DOI: 10.1016/j.prosdent.2014.12.002] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2014] [Revised: 11/27/2014] [Accepted: 12/01/2014] [Indexed: 10/23/2022]
|
13
|
Effect of fatigue on biaxial flexural strength of bilayered porcelain/zirconia (Y-TZP) dental ceramics. Dent Mater 2011; 27:786-95. [DOI: 10.1016/j.dental.2011.03.019] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2010] [Revised: 10/24/2010] [Accepted: 03/30/2011] [Indexed: 11/24/2022]
|
14
|
Huang C, Hsueh C. Piston-on-three-ball versus piston-on-ring in evaluating the biaxial strength of dental ceramics. Dent Mater 2011; 27:e117-23. [DOI: 10.1016/j.dental.2011.02.011] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2010] [Revised: 11/30/2010] [Accepted: 02/24/2011] [Indexed: 11/15/2022]
|