Braga SSL, Price RB, Juckes SM, Sullivan B, Soares CJ. Effect of the violet light from polywave light-polymerizing units on two resin cements that use different photoinitiators. J Prosthet Dent 2024; 131:744-751. [PMID: 35369979 DOI: 10.1016/j.prosdent.2022.02.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Revised: 02/19/2022] [Accepted: 02/21/2022] [Indexed: 11/18/2022]
Abstract
STATEMENT OF PROBLEM Some light-emitting diode polymerization lights have been promoted as multiple peak or polywave lights that use multiple light-emitting diodes to produce both violet and blue light. However, whether the addition of violet light is required to light-activate resin cements that use bis(4-methoxybenzoyl)diethylgermane (Ivocerin) as the photoinitiator is unclear. PURPOSE This in vitro study evaluated the effect of violet, blue, or a combination of violet and blue light through ceramic on the degree of conversion of 2 resin cements that use either camphorquinone or Ivocerin as the photoinitiator. MATERIAL AND METHODS A Bluephase Style polywave light-emitting diode polymerizing unit delivering 6.4 J/cm2 of violet and blue light was used. This comprised 1.4 J/cm2 of violet (385 to 420 nm) and 5.0 J/cm2 of blue light (420 to 515 nm). The light-emitting diode emitters in a second modified Bluephase Style were connected directly to a power supply so that either just violet (1.4 J/cm2) or just blue (5.0 J/cm2) light was emitted. RelyX Veneer and Variolink Esthetic LC resin cements were either directly light-activated or through 0.5 or 1.5 mm of lithium disilicate ceramic (IPS e.max CAD). The degree of conversion was monitored by using Fourier-transform infrared spectroscopy. Data were subject to a 3-way analysis of variance followed by the Tukey honest significant difference multiple comparison tests (α=.05). RESULTS All factors had a significant effect (P<.001). Increasing the ceramic thickness decreased the degree of conversion only for RelyX Veneer cement (P<.001). The effect of the thickness of ceramic was most noticeable when just violet light was delivered to RelyX Veneer. A significant reduction (P<.001) was found in the degree of conversion of RelyX Veneer when just violet light was delivered. Variolink Esthetic LC had significantly higher degree of conversion values than RelyX Veneer, irrespective of the light type used (P<.001). CONCLUSIONS A multiple-peak light is not required to photopolymerize a resin cement that uses either camphorquinone or Ivocerin as its photoinitiator. Adding the violet light produced no significant increase in the degree of conversion of the Variolink Esthetic LC cement.
Collapse
Affiliation(s)
- Stella Sueli Lourenço Braga
- Doctoral student, Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil
| | - Richard Bengt Price
- Professor, Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Stefan Mikhail Juckes
- Research Assistant, Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Braden Sullivan
- Research Assistant, Department of Dental Clinical Sciences, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Carlos José Soares
- Professor and Chair, Department of Operative Dentistry and Dental Materials, Dental School, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.
| |
Collapse
|
2
|
Fidalgo-Pereira R, Catarino SO, Carvalho Ó, Veiga N, Torres O, Braem A, Souza JCM. Light transmittance through resin-matrix composite onlays adhered to resin-matrix cements or flowable composites. J Mech Behav Biomed Mater 2024; 151:106353. [PMID: 38194785 DOI: 10.1016/j.jmbbm.2023.106353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Revised: 12/21/2023] [Accepted: 12/24/2023] [Indexed: 01/11/2024]
Abstract
OBJECTIVE The aim of this study was to evaluate the influence of the thickness of resin-matrix composite blocks manufactured by CAD-CAM on the light transmittance towards different resin-matrix cements or flowable composites. METHODS Sixty specimens of resin-matrix composite CAD-CAM blocks reinforced with 89 wt% inorganic fillers were cross-sectioned with 2 or 3 mm thicknesses. The specimens were conditioned with adhesive system and divided in groups according to the luting material, namely: two dual-cured resin-matrix cements, two traditional flowable resin-matrix composites, and one thermal-induced flowable resin-matrix composite. Specimens were light-cured at 900 mW/cm2 for 40s. Light transmittance assays were preformed using a spectrophotometer with an integrated monochromator before and after light-curing. Microstructural analysis was performed by optical and scanning electron microscopy (SEM). Nanoindentation tests were performed to evaluate mechanical properties for indirect evaluation of degree of monomers conversion. RESULTS Optical and SEM images revealed low thickness values for the cementation interfaces for the traditional flowable resin-matrix composite. The cement thickness increased with the size and content of inorganic fillers. The highest light transmittance was recorded for the onlay blocks cemented with the traditional flowable resin-matrix composites while a group cemented with the dual-cured resin-matrix cement revealed the lowest light transmittance. The elastic modulus and hardness increased for specimens with high content of inorganic fillers as well as it increased in function of the light transmittance. CONCLUSIONS The light transmittance of flowable resin-matrix composites was higher than that for resin-matrix cement after cementation to resin-matrix composites blocks. The type, size, and content of inorganic fillers of the luting material affected the thickness of the cement layer and light transmittance through the materials. CLINICAL RELEVANCE On chair-side light curing, the transmission of visible light can be interfered by the chemical composition and viscosity of the luting materials. The increase in size and content of inorganic fillers of resin-matrix composites and luting materials can decrease the light transmittance leading to inefficient polymerization.
Collapse
Affiliation(s)
- Rita Fidalgo-Pereira
- Center for Interdisciplinary Research in Health (CIIS), Faculty of Dental Medicine (FMD), Universidade Católica Portuguesa (UCP), 3504-505, Viseu, Portugal
| | - Susana O Catarino
- Center for MicroElectroMechanical Systems (CMEMS-UMinho), University of Minho, 4800-058, Guimarães, Portugal; LABBELS - Associate Laboratory, University of Minho, Guimarães, 4710-057 Braga, Portugal
| | - Óscar Carvalho
- Center for MicroElectroMechanical Systems (CMEMS-UMinho), University of Minho, 4800-058, Guimarães, Portugal; LABBELS - Associate Laboratory, University of Minho, Guimarães, 4710-057 Braga, Portugal
| | - Nélio Veiga
- Center for Interdisciplinary Research in Health (CIIS), Faculty of Dental Medicine (FMD), Universidade Católica Portuguesa (UCP), 3504-505, Viseu, Portugal
| | - Orlanda Torres
- Oral Pathology and Rehabilitation Research Unit (UNIPRO), University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal
| | - Annabel Braem
- Department of Materials Engineering (MTM), Biomaterials and Tissue Engineering Research Group, KU Leuven, 3000 Leuven, Belgium
| | - Júlio C M Souza
- Center for Interdisciplinary Research in Health (CIIS), Faculty of Dental Medicine (FMD), Universidade Católica Portuguesa (UCP), 3504-505, Viseu, Portugal; Center for MicroElectroMechanical Systems (CMEMS-UMinho), University of Minho, 4800-058, Guimarães, Portugal; LABBELS - Associate Laboratory, University of Minho, Guimarães, 4710-057 Braga, Portugal.
| |
Collapse
|
3
|
Zancopé K, Borges G, Ribeiro M, Miranda RR, Peres TS, Soares CJ. Influence of Mono- and Multiwave Light-curing Units on the Microhardness and Degree of Conversion of Light-cured Resin Cements. Oper Dent 2023; 48:711-719. [PMID: 37881034 DOI: 10.2341/23-039-l] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/10/2023] [Indexed: 10/27/2023]
Abstract
OBJECTIVES This study evaluated the Knoop hardness (KH, N/mm2) and degree of conversion (DC, %) on the margins of light-cured resin cements with different photoinitiators using a single light-curing unit (LCU) with two heads (mono- and multiwave). METHODS AND MATERIALS Three types of resin cements were used with different photoinitiators: Megalink Esthetic (Odontomega, São Paulo, Brazil) with a camphorquinone photoinitiator; Allcem Veneer (FGM, Joinville, Brazil) with the Advanced Polymerization system (APS), and Variolink Esthetic LC (Ivoclar Vivadent, Schaan, Liechtenstein). Thirty samples were collected and divided into six groups (n=5 each). The resin cement samples were made into the shape of a maxillary right central incisor and photoactivated under a 0.5-mm-thick ceramic sheet. A single LCU (Radii Xpert, SDI) with two heads (mono- and multiwave) was used. The tip of the LCU was positioned at the center of the sample in a standardized manner. Raman spectroscopy was performed to evaluate the DC, and KH was evaluated through the Knoop microhardness test. Five regions were evaluated: cervical, mesial, buccal (center), distal, and incisal. RESULTS There was a significant difference in the DC only for the type of cement (p<0.001), indicating that the cement with the APS photoinitiator presented excellent results. There were significant differences in the type of cement (p<0.001), type of light (p<0.001), region (p<0.001), and the interaction between the type of cement and type of light (p<0.001). The resin cement with the APS photoinitiator cured with monowave light showed the highest KH values. The beam profiles of all groups, with and without the interposition of ceramic and resin cement, were examined by light transmission. CONCLUSIONS The cement with the APS photoinitiator presented the best results with respect to the DC and KH. In comparison with mono- and multiwaves, the LCU may not be a determining factor for the properties of light-cured resin cements. The buccal region showed the best results for DC and KH, indicating the need for a greater amount of light-curing at the cementation margins.
Collapse
Affiliation(s)
- K Zancopé
- *Karla Zancopé, DDS, MSc, PhD, professor, Department of Occlusion, Fixed Prosthesis and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - Gcs Borges
- Giovanna C S Borges, DDS, MS, Department of Occlusion, Fixed Prosthesis and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - Mth Ribeiro
- Maria Tereza H Ribeiro, DDS, MS, PhD student, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - R R Miranda
- Rafael R Miranda, DDS, MS, PhD, professor, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - T S Peres
- Thiago S Peres, DDS, MS, PhD student, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, MG, Brazil
| | - C J Soares
- Carlos J Soares, DDS, MS, PhD, professor and chair, Department of Operative Dentistry and Dental Materials, School of Dentistry, Federal University of Uberlândia, Uberlândia, MG, Brazil
| |
Collapse
|
4
|
Lim DS, Chung JK, Yun JS, Park MS. Fabrication of 3D Printed Ceramic Part Using Photo-Polymerization Process. Polymers (Basel) 2023; 15:polym15071601. [PMID: 37050215 PMCID: PMC10096816 DOI: 10.3390/polym15071601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 03/19/2023] [Accepted: 03/21/2023] [Indexed: 04/14/2023] Open
Abstract
Ceramics are high-strength and high-temperature resistant materials that are used in various functional parts. However, due to the high strength and brittleness properties, there are many difficulties in the fabrication of complex shapes. Therefore, there are many studies related to the fabrication of ceramic parts using 3D printing technology optimized for complex shapes. Among them, studies using photo-polymerization (PP) 3D printing technology with excellent dimensional accuracy and surface quality have received the most widespread attention. To secure the physical properties of sintered ceramic, the content and distribution of materials are important. This study suggests a novel 3D printing process based on a high-viscosity composite resin that maximizes the content of zirconia ceramics. For reliable printing, the developed 3D printers that can adjust the process environment were used. To minimize warpage and delamination, the divided micro square pattern images were irradiated in two separate intervals of 1.6 s each while maintaining the internal chamber temperature at 40 °C. This contributed to improved stability and density of the sintered structures. Ultimately, the ceramic parts with a Vickers hardness of 12.2 GPa and a relative density of over 95% were able to be fabricated based on a high-viscosity resin with 25,000 cps.
Collapse
Affiliation(s)
- Da-Sol Lim
- Department of Mechanical System Design Engineering, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Republic of Korea
| | - Jin-Kyo Chung
- Department of Mechanical Information Engineering, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Republic of Korea
| | - Ji-Sun Yun
- Energy & Environmental Division, Korea Institute of Ceramic Engineering and Technology, 101, Soho-ro, Jinju 52851, Republic of Korea
| | - Min-Soo Park
- Department of Mechanical System Design Engineering, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul 01811, Republic of Korea
| |
Collapse
|
5
|
de Castro EF, Fronza BM, Soto-Montero J, Giannini M, Dos-Santos-Dias CT, Price RB. Effect of thickness of CAD/CAM materials on light transmission and resin cement polymerization using a blue light-emitting diode light-curing unit. J ESTHET RESTOR DENT 2023; 35:368-380. [PMID: 35894446 DOI: 10.1111/jerd.12946] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 07/05/2022] [Accepted: 07/11/2022] [Indexed: 11/29/2022]
Abstract
OBJECTIVE Evaluate the effect of thickness of high-translucency (HT) CAD/CAM materials on irradiance and beam profile from a blue light-emitting diode light-curing unit (LCU) and on the degree of conversion (DC) and maximum polymerization rate (Rpmax ) of a light-cured resin cement (LCC). MATERIAL AND METHODS The direct output from the LCU, the light transmission and irradiance ratio (IR) through one conventional composite and nine HT CAD/CAM materials (0.5, 1.0, 1.5, or 2.0-mm thick; n = 5) were measured with a integrating sphere coupled to a spectrometer. The light beam was assessed with a beam profiler camera. The DC at 600 s and the Rpmax of one LCC was determined using a Fourier transform infrared spectrometer (n = 5). Data were analyzed by ANOVA followed by Tukey's tests, and Dunnett's test was also used for irradiance data (α = 0.05). RESULTS A significant decrease in irradiance through all materials occurred as thickness increased. Thin CAD/CAM materials improved light homogeneity, which decreased with the increase in thickness. The DC of the LCC directly exposed to light was the same as when exposed to 45%, 25%, 15%, or 5% IRs. Rpmax decreased with the decrease in IR. CONCLUSIONS Although the HT CAD/CAM materials reduced the irradiance from the LCU, minor effects were observed in the LCC's DC. CLINICAL SIGNIFICANCE Despite the light attenuation of blue light through different CAD/CAM materials that were up to 2-mm thick, the degree of conversion of one brand of light-cured resin cement was clinically acceptable when the LCU was used for 30 s.
Collapse
Affiliation(s)
- Eduardo Fernandes de Castro
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, Brazil
| | - Bruna Marin Fronza
- Department of Biomaterials and Oral Biology, School of Dentistry, University of São Paulo, São Paulo, Brazil
| | - Jorge Soto-Montero
- Department of Restorative Dentistry, School of Dentistry, Universidad de Costa Rica, San Pedro, Costa Rica
| | - Marcelo Giannini
- Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, Piracicaba, Brazil
| | - Carlos Tadeu Dos-Santos-Dias
- Department of Exact Sciences, College of Agriculture, "Luiz de Queiroz"/University of São Paulo, Piracicaba, Brazil
| | - Richard Bengt Price
- Department of Dental Clinical Sciences, School of Dentistry, Dalhousie University, Halifax, Canada
| |
Collapse
|
6
|
Fidalgo-Pereira R, Torres O, Carvalho Ó, Silva FS, Catarino SO, Özcan M, Souza JCM. A Scoping Review on the Polymerization of Resin-Matrix Cements Used in Restorative Dentistry. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1560. [PMID: 36837188 PMCID: PMC9961405 DOI: 10.3390/ma16041560] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 02/08/2023] [Accepted: 02/09/2023] [Indexed: 06/18/2023]
Abstract
In dentistry, clinicians mainly use dual-cured or light-cured resin-matrix cements to achieve a proper polymerization of the organic matrix leading to enhanced physical properties of the cement. However, several parameters can affect the polymerization of resin-matrix cements. The main aim of the present study was to perform a scoping review on the degree of conversion (DC) of the organic matrix, the polymerization, and the light transmittance of different resin-matrix cements used in dentistry. A search was performed on PubMed using a combination of the following key terms: degree of conversion, resin cements, light transmittance, polymerization, light curing, and thickness. Articles in the English language published up to November 2022 were selected. The selected studies' results demonstrated that restorative structures with a thickness higher than 1.5 mm decrease the light irradiance towards the resin-matrix cement. A decrease in light transmission provides a low energy absorption through the resin cement leading to a low DC percentage. On the other hand, the highest DC percentages, ranging between 55 and 75%, have been reported for dual-cured resin-matrix cements, although the polymerization mode and exposure time also influence the DC of monomers. Thus, the polymerization of resin-matrix cements can be optimized taking into account different parameters of light-curing, such as adequate light distance, irradiance, exposure time, equipment, and wavelength. Then, optimum physical properties are achieved that provide a long-term clinical performance of the cemented restorative materials.
Collapse
Affiliation(s)
- Rita Fidalgo-Pereira
- University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal
- Center for Interdisciplinary Research in Health (CIIS), Faculty of Dental Medicine (FMD), Universidade Católica Portuguesa (UCP), 3504-505 Viseu, Portugal
| | - Orlanda Torres
- University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal
| | - Óscar Carvalho
- Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058 Guimarães, Portugal
- LABBELS Associate Laboratory, University of Minho, 4805-017 Guimarães, Portugal
| | - Filipe S. Silva
- Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058 Guimarães, Portugal
- LABBELS Associate Laboratory, University of Minho, 4805-017 Guimarães, Portugal
| | - Susana O. Catarino
- Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058 Guimarães, Portugal
- LABBELS Associate Laboratory, University of Minho, 4805-017 Guimarães, Portugal
| | - Mutlu Özcan
- Division of Dental Biomaterials, Center of Dental Medicine, Clinic of Reconstructive Dentistry, University of Zurich, 8032 Zurich, Switzerland
| | - Júlio C. M. Souza
- University Institute of Health Sciences (IUCS), CESPU, 4585-116 Gandra, Portugal
- Center for MicroElectroMechanical Systems (CMEMS-UMINHO), University of Minho, Campus Azurém, 4800-058 Guimarães, Portugal
- LABBELS Associate Laboratory, University of Minho, 4805-017 Guimarães, Portugal
| |
Collapse
|
7
|
Dental Luting Cements: An Updated Comprehensive Review. Molecules 2023; 28:molecules28041619. [PMID: 36838607 PMCID: PMC9961919 DOI: 10.3390/molecules28041619] [Citation(s) in RCA: 30] [Impact Index Per Article: 30.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2022] [Revised: 01/27/2023] [Accepted: 02/06/2023] [Indexed: 02/11/2023] Open
Abstract
The cementation of indirect restoration is one of the most important steps in prosthetic and restorative dentistry. Cementation aims to bond the prosthetic restoration to the prepared enamel or enamel and dentine. Successful cementation protocols prevent biofilm formation at the margin between tooth and restoration and minimize mechanical and biological complications. With the advancements in dental cements, they have been modified to be versatile in terms of handling, curing, and bond strengths. This review presents updates on dental cements, focusing on the composition, properties, advantages, limitations, and indications of the various cements available. Currently, dental restorations are made from various biomaterials, and depending on each clinical case, an appropriate luting material will be selected. There is no luting material that can be universally used. Therefore, it is important to distinguish the physical, mechanical, and biological properties of luting materials in order to identify the best options for each case. Nowadays, the most commonly used dental cements are glass-ionomer and resin cement. The type, shade, thickness of resin cement and the shade of the ceramic, all together, have a tangible influence on the final restoration color. Surface treatments of the restoration increase the microtensile bond strength. Hence, the proper surface treatment protocol of both the substrate and restoration surfaces is needed before cementation. Additionally, the manufacturer's instructions for the thin cement-layer thickness are important for the long-term success of the restoration.
Collapse
|
8
|
Babaier R, Haider J, Silikas N, Watts DC. Effect of CAD/CAM aesthetic material thickness and translucency on the polymerisation of light- and dual-cured resin cements. Dent Mater 2022; 38:2073-2083. [DOI: 10.1016/j.dental.2022.11.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2022] [Revised: 11/11/2022] [Accepted: 11/11/2022] [Indexed: 11/27/2022]
|
9
|
Carek A, Dukaric K, Miler H, Marovic D, Tarle Z, Par M. Post-Cure Development of the Degree of Conversion and Mechanical Properties of Dual-Curing Resin Cements. Polymers (Basel) 2022; 14:polym14173649. [PMID: 36080725 PMCID: PMC9460751 DOI: 10.3390/polym14173649] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 08/28/2022] [Accepted: 08/30/2022] [Indexed: 11/17/2022] Open
Abstract
This study investigated the effect of different curing conditions on the degree of conversion and mechanical properties of contemporary dual-curing resin cements. The material specimens were either light-cured directly, light-cured through a 1-mm lithium disilicate glass-ceramic layer, or self-cured. The degree of conversion was measured in 0.1-mm films using Fourier-transform infrared spectroscopy 1 day, 7 days, and 28 days post-cure. Specimens used to study the flexural strength and modulus were prepared according to the ISO 4049 protocol, stored for 28 days post-cure, and subjected to accelerated aging by absolute ethanol immersion. The degree of conversion values ranged between 44.3–77.8%. Flexural strength varied between 11.4–111.1 MPa, while flexural modulus amounted to 0.7–5.5 GPa. The degree of conversion was significantly affected by material type, curing conditions, and post-cure time; however, variations in curing conditions were the least influential factor. A statistically significant effect of curing conditions on the degree of conversion was identified for only one of the five materials tested, whereas the flexural strength and modulus of all tested materials were significantly reduced in the experimental groups that were light-cured through a ceramic layer or self-cured. The effect size analysis showed that mechanical properties were most affected by the material type, while the differences in curing conditions were less influential. A comparison of the degree of conversion and mechanical properties indicated that different curing conditions may lead to significantly different flexural strength and modulus, which are not necessarily accompanied by identifiable variations in the degree of conversion.
Collapse
Affiliation(s)
- Andreja Carek
- Department of Fixed Prosthodontics, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Ksenija Dukaric
- School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Helena Miler
- School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Danijela Marovic
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Zrinka Tarle
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
| | - Matej Par
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, Gunduliceva 5, 10000 Zagreb, Croatia
- Correspondence:
| |
Collapse
|
10
|
Aquino Valverde AJ, Aguilar Vargas GDP, Díaz Fernández JM, Leiva Ramírez PA, Quintanilla Labajos DA, Atoche Socola KJ, Vidalón Pinto M. [Light-curing effectiveness using led lamps: a review]. REVISTA CIENTÍFICA ODONTOLÓGICA 2022; 10:e120. [PMID: 38389554 PMCID: PMC10880699 DOI: 10.21142/2523-2754-1003-2022-120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Accepted: 09/02/2022] [Indexed: 02/24/2024] Open
Abstract
Introduction LED lamps have a new light-curing technology which can be monowave or polywave, which allows it to reach more initiators such as camphorquinone, Lucirin TPO and Propanodione, which have a wide variety of advantages and disadvantages. These lamps have evolved over time, as have different ergonomics, longevity, systems and quality standards. Objective The objective of this literature review is to improve the clinician on the proper use of different LED lamps and how they influence the efficiency of resin photopolymerization. Material and methods Extensive research has been carried out in the existing literature on this topic. From the beginning of this information until April 18, 2022, the bibliographic search carried out includes 86 articles published in the Medline database through PubMed, LILACS, Science Direct and SciELO, and there is no language restriction. Results The photopolymerization effects of Polywave and Monowave LED lamps present significant differences between the compressive strength of the light-cured resin, with single-wave and polyvalent LED lamps where the types of light and lamp directly influence the compressive strength of the resin. composite resins. Conclusion The type of light and lamp directly affects the efficiency of the photopolymerization of the composite resin, so it is concluded that LED lamps with single wave technology (Monowave) produce a greater depth of photopolymerization than those with multiple wave technology (Polywave).
Collapse
Affiliation(s)
- Alexandra Jacqueline Aquino Valverde
- Facultad de Odontologia, Universidad Cientifica del Sur. Lima-Peru. , , , , , Universidad Científica del Sur Facultad de Odontologia Universidad Cientifica del Sur Lima Peru
| | - Gina Del Pilar Aguilar Vargas
- Facultad de Odontologia, Universidad Cientifica del Sur. Lima-Peru. , , , , , Universidad Científica del Sur Facultad de Odontologia Universidad Cientifica del Sur Lima Peru
| | - José Miguel Díaz Fernández
- Facultad de Odontologia, Universidad Cientifica del Sur. Lima-Peru. , , , , , Universidad Científica del Sur Facultad de Odontologia Universidad Cientifica del Sur Lima Peru
| | - Piero Aryed Leiva Ramírez
- Facultad de Odontologia, Universidad Cientifica del Sur. Lima-Peru. , , , , , Universidad Científica del Sur Facultad de Odontologia Universidad Cientifica del Sur Lima Peru
| | - Daleska Adriana Quintanilla Labajos
- Facultad de Odontologia, Universidad Cientifica del Sur. Lima-Peru. , , , , , Universidad Científica del Sur Facultad de Odontologia Universidad Cientifica del Sur Lima Peru
| | - Katherine Joselyn Atoche Socola
- Division de Rehabilitacion Oral, Facultad de Odontologia, Universidad Cientifica del Sur. Lima-Peru. Universidad Científica del Perú Division de Rehabilitacion Oral Facultad de Odontologia Universidad Cientifica del Sur Lima Peru
| | - Marcia Vidalón Pinto
- Facultad de Odontologia, Universidad Cientifica del Sur. Lima-Peru. , , , , , Universidad Científica del Sur Facultad de Odontologia Universidad Cientifica del Sur Lima Peru
| |
Collapse
|
11
|
Depth of cure of 10 resin-based composites light-activated using a laser diode, multi-peak, and single-peak light-emitting diode curing lights. J Dent 2022; 122:104141. [PMID: 35483497 DOI: 10.1016/j.jdent.2022.104141] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2022] [Revised: 04/19/2022] [Accepted: 04/21/2022] [Indexed: 11/20/2022] Open
Abstract
OBJECTIVES To evaluate the depth of cure (DOC) of ten contemporary resin-based composites (RBCs), light-cured using different LCUs and exposure times. METHODS The power, radiant emittance, irradiance, radiant exposure (RE), and beam profiles from a laser (M, Monet), a multi-peak (V, Valo Grand), and single-peak (S, SmartLite Pro) LCU were measured. The DOC was measured using a 6-mm diameter metal mold and a solvent dissolution method to remove the uncured RBC. The length of the remaining RBC was divided by 2. The exposure times were: 1s and 3s for M, 10s and 20s for V, and 10s and 20s for S. Data were analyzed using: Bland-Altman distribution, Pearson's Correlation, and an artificial neural network (ANN) to establish the relative importance of the factors on the DOC (α=0.05; β=0.2). RESULTS Significant differences were found in the DOC of the different LCUs and composites. The laser LCU emitted the highest power, radiant emittance, and irradiance. However, this LCU used for 1 s delivered the lowest RE and produced the shortest DOC in all ten RBCs. The ANN demonstrated that the RE is the most critical factor for the DOC. Bland-Altman comparisons showed that the DOCs achieved with the laser LCU used for 1s were between 17 - 34 % shorter than the other conditions. CONCLUSIONS Although the laser LCU cured all 10 RBCs when used for 1s, it produced the shallowest DOC, and some RBCs did not achieve the minimum DOC threshold. The RE and not the irradiance was the most important factor in determining the DOC of RBCs. CLINICAL SIGNIFICANCE Despite delivering high power and irradiance, the laser used for l s delivered a lower radiant exposure than the conventional LCUs used for 10 s. This resulted in a shorter DOC.
Collapse
|
12
|
Pereira CNDB, Magalhães CS, Lages FS, Ferreira RDC, da Silva EH, da Silveira RR, Corrêa ECS, Fantini CL, Moreira AN. Degree of conversion and microhardness of resin cements photoactivated through glass ceramic. J Clin Exp Dent 2021; 13:e1068-e1075. [PMID: 34824691 PMCID: PMC8601702 DOI: 10.4317/jced.58630] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Accepted: 08/24/2021] [Indexed: 11/05/2022] Open
Abstract
Background To assess whether glass-ceramic shade, thickness and translucency affect degree of conversion (DC) and Knoop microhardness (KHN) of resin cements photoactivated using light-emitting diode (LED) or quartz-tungsten-halogen (QTH) units. Material and Methods Glass-ceramic blocks were cut (2, 3 and 4mm) and sintered. For DC FT Raman spectroscopy (n=3), film specimens of cements (RelyX ARC, U200, Veneer, C&B) were obtained. For KHN test (n=3), cements were inserted in cylindrical matrix and covered by polyester strip. Specimens were photoactivated (30s) using LED or QTH according to each group: direct photoactivation (DP), interposing ceramic specimens or no photoactivation (NP). Data were analysed by ANOVA and Tukey's test, Kruskal-Wallis and Dunn's tests (p<0.05). Results Ceramic features had significant effect on DC of RelyX ARC, U200 and Veneer (p<0.0017). Light source had no effect (p=0.9512). C&B and Veneer had higher DC, followed by dual cements. NP dual cements showed the lowest DC. For KHN, ceramic shade (p=0.1717) and light source (p=0.1421) were not significant, but ceramic translucency, thickness and resin cement were significant (p=0.0001). KHN was higher for U200 followed by ARC, and lowest for Veneer. Conclusions DC was affected by ceramic shade, translucency and thickness. KHN was dependent on ceramic translucency and thickness. Higher DC and KHN were achieved for dual-cured cements photoactivated through 2mm-thick low translucent or 3mm-thick high translucent glass-ceramic. Key words:Cementation, composite resin cements, dental curing lights, glass ceramics.
Collapse
Affiliation(s)
| | - Cláudia-Silami Magalhães
- PhD, Professor, Department of Restorative Dentistry, Faculty of Dentistry, Federal University of Minas Gerais, Belo Horizonte, Brazil
| | - Frederico-Santos Lages
- PhD, Professor, Department of Restorative Dentistry, Faculty of Dentistry, Federal University of Minas Gerais, Belo Horizonte, Brazil
| | - Raquel-da Conceição Ferreira
- PhD, Professor, Department of Social and Preventive Dentistry, Faculty of Dentistry, Federal University of Minas Gerais, Belo Horizonte, Brazil
| | | | - Rodrigo-Richard da Silveira
- PhD, Professor, Department of Restorative Dentistry, Faculty of Dentistry, Federal University of Minas Gerais, Belo Horizonte, Brazil
| | - Elaine-Carballo-Siqueira Corrêa
- PhD, Professor, Department of Metalography, Centro Federal de Educação Tecnológica de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil
| | - Cristiano-Leite Fantini
- PhD, Professor, Department of Optical Physics, Instituto de Ciências Exatas, Federal University of Minas Gerais, Belo Horizonte, Brazil
| | - Allyson-Nogueira Moreira
- PhD, Professor, Department of Restorative Dentistry, Faculty of Dentistry, Federal University of Minas Gerais, Belo Horizonte, Brazil
| |
Collapse
|
13
|
Time-dependent degree of conversion, Martens parameters, and flexural strength of different dual-polymerizing resin composite luting materials. Clin Oral Investig 2021; 26:1067-1076. [PMID: 34342762 PMCID: PMC8791875 DOI: 10.1007/s00784-021-04091-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Accepted: 07/19/2021] [Indexed: 12/02/2022]
Abstract
Objective To investigate the degree of conversion (DC), Martens hardness (HM), elastic indentation modulus (EIT), and biaxial flexural strength (BFS) of six dual-polymerizing resin composite luting materials initially and after 2 and 7 days of aging. Materials and methods Specimens fabricated from Bifix QM (BIF; VOCO), Calibra Ceram (CAL; Dentsply Sirona), DuoCem (DUO; Coltène/Whaledent), G-CEM LinkForce (GCE; GC Europe), PANAVIA V5 (PAN; Kuraray Europe), and Variolink Esthetic DC (VAR; Ivoclar Vivadent) (n = 12 per material) were light-polymerized through 1 mm thick discs (Celtra Duo, Dentsply Sirona). DC, HM, and EIT were recorded directly after fabrication, and after 2 and 7 days of aging. As a final test, BFS was measured. Univariate ANOVAs, Kruskal–Wallis, Mann–Whitney U, Friedman, and Wilcoxon tests, and Weibull modulus were computed (p < 0.05). Results While CAL presented low DC, HM, EIT, and BFS values, DUO and BIF showed high results. Highest Weibull moduli were observed for VAR and DUO. DC and Martens parameters increased between the initial measurement and 2 days of aging, while aging for 7 days provided no further improvement. Conclusions The choice of dual-polymerizing resin composite luting material plays an important role regarding chemical and mechanical properties, especially with patients sensitive to toxicological issues. DUO may be recommended for bonding fixed dental prostheses, as it demonstrated significantly highest and reliable results regarding DC, HM, and BFS. As DC and HM showed an increase in the first 48 h, it may be assumed that the polymerization reaction is not completed directly after initial polymerization, which is of practical importance to dentists and patients. Clinical relevance The chemical and mechanical properties of dual-polymerizing resin composite luting materials influence the overall stability and long-term performance of the restoration.
Collapse
|
14
|
Borges LPS, Borges GA, Correr AB, Platt JA, Kina S, Correr-Sobrinho L, Costa AR. Effect of lithium disilicate ceramic thickness, shade and translucency on transmitted irradiance and knoop microhardness of a light cured luting resin cement. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2021; 32:90. [PMID: 34338911 PMCID: PMC8328902 DOI: 10.1007/s10856-021-06562-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2020] [Accepted: 07/13/2021] [Indexed: 06/02/2023]
Abstract
This in vitro study evaluates the influence of pressed lithium disilicate thickness, shade and translucency on the transmitted irradiance and the Knoop microhardness (KHN) of a light-cured resin cement at two depths. One hundred and thirty-five ceramic discs of IPS e.max Press (Ivoclar Vivadent) were fabricated and divided into twenty-seven groups (n = 5) according to the association between translucency: HT (hight translucency), LT (low translucency), and MO (medium opacity); shade: BL2, A1 and A3.5; and thickness: 0.5 mm, 1.5 mm, and 2.0 mm. One side of each ceramic disc was finished, polished and glazed. The irradiance (mW/cm²) of a multiwave LED light curing unit (Valo, Ultradent) was evaluated with a potentiometer (Ophir 10ª-V2-SH, Ophir Optronics) without (control group) or with interposition of ceramic samples. The microhardness of Variolink Esthetic LC resin cement (Ivoclar Vivadent) was evaluated after 24 h at two depths (100 μm and 700 μm). Data were submitted to ANOVA followed by Tukey's test (α = 0.05). Irradiance and KHN were significantly influenced by ceramic thickness (p < 0.0001), shade (p < 0.001), translucency (p < 0.0001) and depth (p < 0.0001). Conclusions: the interposition of increasing ceramic thicknesses significantly reduced the irradiance and microhardness of resin cement. Increased depth in the resin cement showed significantly reduced microhardness for all studied groups. Increased ceramic opacity reduced the KHN of the resin cement at both depths for all ceramic thicknesses and shades.
Collapse
Affiliation(s)
- Lincoln Pires Silva Borges
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| | - Gilberto Antônio Borges
- Department of Dental Materials and Restorative Dentistry, University of Uberaba, Uberaba, MG, Brazil
| | - Américo Bortolazzo Correr
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| | - Jeffrey A Platt
- Associate Professor of Dental Materials, Indiana University School of Dentistry, Indianapolis, IN, USA
| | - Sidney Kina
- Associate Professor, Kina Essential Balance Institute, Maringá, PR, Brazil
| | - Lourenço Correr-Sobrinho
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil
| | - Ana Rosa Costa
- Department of Restorative Dentistry, Dental Materials Division, Piracicaba Dental School, State University of Campinas - UNICAMP, Piracicaba, SP, Brazil.
| |
Collapse
|
15
|
Li Q, Lin HL, Zheng M, Ozcan M, Yu H. Minimum Radiant Exposure and Irradiance for Triggering Adequate Polymerization of a Photo-Polymerized Resin Cement. MATERIALS 2021; 14:ma14092341. [PMID: 33946389 PMCID: PMC8124640 DOI: 10.3390/ma14092341] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 04/23/2021] [Accepted: 04/26/2021] [Indexed: 12/02/2022]
Abstract
This study aimed to establish the minimum radiant exposure and irradiance to trigger an adequate polymerization of a photo-polymerized resin cement. In total, 220 disc-shaped specimens (diameter of 10 mm and thickness of 0.1 mm) were fabricated using a photo-polymerized resin cement (Variolink N-transparent, Ivoclar Vivadent). To investigate the minimum radiant exposure, the specimens were polymerized with radiant exposures of 1, 2, 3, 4, 5, 6, and 18 J/cm2 (n = 20). During polymerization, the irradiance was maintained at 200 mW/cm2. To investigate the minimum irradiance, the specimens were polymerized with irradiances of 50, 100, 150, and 200 mW/cm2 (n = 20). During polymerization, the radiant exposure was maintained at the previously determined minimum radiant exposure. The Vickers microhardness (HV) and degree of conversion (DC) of the carbon double bond of the specimens were measured to determine the degree of polymerization of the specimens. The results were analyzed using one-way analysis of variance (ANOVA) and Tukey’s test (p < 0.05). In the investigation of the minimum radiant exposure, the HV and DC of the specimens polymerized with a radiant exposure from 1 to 5 J/cm2 were significantly lower than those with 18 J/cm2 (all p < 0.05). However, no significant difference in HV and DC was found between the specimens polymerized with 6 J/cm2 and 18 J/cm2 (p > 0.05). In the investigation of the minimum irradiance, the specimens polymerized with an irradiance of 50 mW/cm2 had significantly lower HV and DC than the specimens polymerized with an irradiance of 200 mW/cm2 (p < 0.05). However, no significant difference in the HV and DC was found among the specimens cured with irradiances of 100, 150, and 200 mW/cm2 (p > 0.05). In conclusion, the minimum radiant exposure and irradiance to trigger an adequate polymerization of the light-cured resin cement were 6 J/cm2 and 100 mW/cm2, respectively.
Collapse
Affiliation(s)
- Qi Li
- Fujian Key Laboratory of Oral Diseases, Fujian Provincial Engineering Research Center of Oral Biomaterial, Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou 350000, China; (Q.L.); (H.-L.L.)
- Fujian Provincial Governmental Hospital, Fuzhou 350000, China
| | - Hong-Lei Lin
- Fujian Key Laboratory of Oral Diseases, Fujian Provincial Engineering Research Center of Oral Biomaterial, Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou 350000, China; (Q.L.); (H.-L.L.)
| | - Ming Zheng
- Fujian Key Laboratory of Oral Diseases, Fujian Provincial Engineering Research Center of Oral Biomaterial, Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou 350000, China; (Q.L.); (H.-L.L.)
- Correspondence: (M.Z.); or (H.Y.)
| | - Mutlu Ozcan
- Division of Dental Biomaterials, Clinic for Reconstructive Dentistry, Center for Dental Medicine, University of Zurich, 8006 Zurich, Switzerland;
| | - Hao Yu
- Fujian Key Laboratory of Oral Diseases, Fujian Provincial Engineering Research Center of Oral Biomaterial, Stomatological Key Laboratory of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University, Fuzhou 350000, China; (Q.L.); (H.-L.L.)
- Correspondence: (M.Z.); or (H.Y.)
| |
Collapse
|