1
|
Lee SW, Lee D, Kim J, An S, Park CH, Lee JM, Yon CJ, Heo YR. Comparison of Biocompatibility of 3D-Printed Ceramic and Titanium in Micropig Ankle Hemiarthroplasty. Biomedicines 2024; 12:2696. [PMID: 39767603 PMCID: PMC11727586 DOI: 10.3390/biomedicines12122696] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2024] [Revised: 11/22/2024] [Accepted: 11/25/2024] [Indexed: 01/16/2025] Open
Abstract
BACKGROUND Ankle arthritis is a common degenerative disease that progresses as cartilage damage in the lower tibia and upper talus progresses, resulting in loss of joint function. In addition to typical arthritis, there is also structural bone loss in the talus due to diseases such as talar avascular necrosis. Total talus replacement surgery is the procedure of choice in end-stage ankle arthritis and consists of a tibial, talar component and an insert. However, in cases of severe cartilage and bone damage to the talar bone with less damage to the tibial cartilage, a talar component hemiarthroplasty may be considered. Although the application of total talus replacement surgery using ceramics has been studied, reports on the application of metal 3D printing technology are limited. We aimed to investigate the feasibility of partial talar components using ceramic and titanium 3D printing technology in terms of biocompatibility and stability through animal experiments. METHODS Preoperative 3D CT was acquired and converted to STL files to fabricate a partial talus component for ankle hemiarthroplasty using ceramic and titanium. Six minipigs with an average age of 17 months were implanted with three ceramic (C-group) and three titanium talar components (T-group) in the hind limb ankle joint. The surgery was performed under anesthesia in a sterile operating room and was performed by two experienced foot and ankle specialist orthopedic surgeons. Blood analysis and CT were performed before surgery and every month for 3 months after surgery to assess the extent of inflammatory response and physical stability, sacrifices were performed 3 months after surgery, and H&E staining and micro-CT analysis were performed to compare histological biocompatibility. A grading score was calculated to semi-quantitative assess and compare the two groups. RESULTS In the postsurgical evaluation, blood analysis revealed that both groups had increased white blood cell counts on the postoperative day after surgery. The white blood cell count increased more in the titanium group (1.85-fold) than in the ceramic group (1.45-fold). After 3 months, all values normalized. During the study, CT analysis confirmed that all artificial samples were displaced from their initial positions. In micro-CT analysis, the adhesive tissue score of the ceramic artificial sample was better than that of the titanium sample (average threshold = 3027.18 ± 405.92). In histologic and grading scores for the inflammatory reactions, the average inflammation indices of the ceramic and titanium groups were 2.0 and 1.21, respectively. Also, the average grade score confirmed based on the results of fibrous tissue proliferation and new blood vessels was 18.4 in the ceramic application group and 12.3 in the titanium application group. CONCLUSIONS In conclusion, both titanium and ceramics have excellent biocompatibility for artificial joints, and ceramic materials can be used as novel artificial joints. Further research on the strength and availability of these ceramics is required.
Collapse
Affiliation(s)
- Si-Wook Lee
- Department of Orthopedic Surgery, Dongsan Medical Center, Keimyung University, Daegu 42601, Republic of Korea; (S.-W.L.)
| | - Donghyun Lee
- Preclinical Research Center, Daegu-Gyeongbuk Medical Innovation Foundation (K-MEDI hub), Daegu 41061, Republic of Korea
| | - Junsik Kim
- Preclinical Research Center, Daegu-Gyeongbuk Medical Innovation Foundation (K-MEDI hub), Daegu 41061, Republic of Korea
| | - Sanghyun An
- Preclinical Research Center, Daegu-Gyeongbuk Medical Innovation Foundation (K-MEDI hub), Daegu 41061, Republic of Korea
| | - Chul-Hyun Park
- Department of Orthopaedic Surgery, College of Medicine, Yeungnam University, Daegu 42415, Republic of Korea
| | - Jung-Min Lee
- Industry-Academic Cooperation Foundation, Keimyung University, Daegu 42601, Republic of Korea
| | - Chang-Jin Yon
- Department of Orthopedic Surgery, Dongsan Medical Center, Keimyung University, Daegu 42601, Republic of Korea; (S.-W.L.)
| | - Yu-Ran Heo
- Division in Anatomy and Developmental Biology, Department of Oral Biology, Human Identification Research Institute, BK21 FOUR Project, Yonsei University College of Dentistry, 50-1 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea
| |
Collapse
|
2
|
Piza MMT, Bergamo ETP, Campos TMB, Carvalho LF, Goulart CA, Gutierres E, Lopes ACO, Benalcazar Jalkh EB, Bonfante EA. Alumina-toughened zirconia nanocomposite: Aging effect on microstructural, optical, and mechanical properties. Dent Mater 2023; 39:1022-1031. [PMID: 37775460 DOI: 10.1016/j.dental.2023.09.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 09/05/2023] [Accepted: 09/15/2023] [Indexed: 10/01/2023]
Abstract
OBJECTIVES To process an alumina-toughened zirconia (ATZ) nanocomposite and to characterize its crystalline phases, microstructure, residual stress, mechanical and optical properties before and after two different artificial aging methodologies. METHODS Disc-shaped specimens were obtained through uniaxial pressing of a commercial ATZ powder comprised of 80%ZrO2 / 20%Al2O3, with a particle size of 50 nm and 150 nm, respectively. Sintering was performed at 1500ºC for 2 h. Groups were established according to the aging protocol as immediate (ATZ-I) and aged either in autoclave (ATZ-A) or hydrothermal reactor (ATZ-R) at 134 ºC for 20 h at 2.2 bar. Crystalline phases and microstructure were assessed by X-ray diffraction (XRD) and scanning electron microscopy (SEM), respectively. Residual stress was evaluated by Raman spectroscopy. Contrast Ratio (CR) and Translucency Parameter (TP) were calculated to characterize optical properties. Mechanical properties were analyzed through Vickers microhardness, fracture toughness, and biaxial flexural strength test. RESULTS XRD spectra of both aging protocols revealed the presence of monoclinic zirconia (20-31%), where higher phase transformation was observed after aging in hydrothermal reactor. Optical properties evaluation demonstrated high opacity (CR: 0.99) and masking ability (TP: 0.26), with no significant differences after aging. Raman spectroscopy evidenced the presence of residual compressive stresses in the aged groups, being significantly higher for ATZ-R (-215.2 MPa). As-sintered specimens revealed hardness of ∼12.3 GPa and fracture toughness of ∼1.9 MPa.m1/2. Characteristic strength was 740 MPa for ATZ-I, 804 MPa for ATZ-A, and 879 MPa for ATZ-R, with significant differences between groups. Weibull modulus ranged from 16.5 to 18.8. All groups demonstrated high reliability up to 500 MPa stress missions (99-100%), with no significant differences after aging. SIGNIFICANCE The experimental ATZ nanocomposite presented high opacity and a high Weibull modulus. While aging created internal compressive stress responsible for an increase in characteristic strength, the nanocomposite was susceptible to hydrothermal degradation. Further studies are required to evaluate its degradation kinetics at low temperatures.
Collapse
Affiliation(s)
- Mariana M T Piza
- Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil.
| | - Edmara T P Bergamo
- Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil
| | - Tiago M B Campos
- Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil; Department of Physics, Technological Institute of Aeronautics, São José dos Campos, SP, Brazil
| | - Laura F Carvalho
- Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil
| | - Celso A Goulart
- São Paulo State University, School of Sciences and Engineering, Tupã, SP, Brazil
| | - Eliezer Gutierres
- Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil
| | - Adolfo C O Lopes
- Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil
| | - Ernesto B Benalcazar Jalkh
- Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil
| | - Estevam A Bonfante
- Department of Prosthodontics and Periodontology, University of São Paulo, Bauru School of Dentistry, Bauru, SP, Brazil
| |
Collapse
|
3
|
Monje A, Roccuzzo A, Buser D, Wang HL. Influence of buccal bone wall thickness on the peri-implant hard and soft tissue dimensional changes: A systematic review. Clin Oral Implants Res 2023; 34 Suppl 26:8-27. [PMID: 37750522 DOI: 10.1111/clr.14177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 12/16/2022] [Accepted: 12/17/2022] [Indexed: 09/27/2023]
Abstract
BACKGROUND The significance on the association between the peri-implant bucco-lingual dimension (BLD) at the stage of implant placement and the occurrence of biological and esthetic complications is yet unknown. MATERIAL AND METHODS Systematic screening of electronic sources was carried out to identify clinical and preclinical studies reporting on the baseline BLD and/or buccal bone thickness (BBT) values. A secondary objective was to assess the effect of simultaneous grafting at sites with deficient or no buccal bone wall (BBW) at baseline. The primary outcome variables were BBT, BLD, and buccal vertical bone loss (VBL) at re-evaluation. Moreover, radiographic, clinical, and patient-reported outcome measures (PROMs) were evaluated. RESULTS Overall, 12 clinical and four preclinical studies met the inclusion criteria. Inconsistencies were found in defining the critical BBT across the clinical and preclinical data evaluated. The clinical evidence demonstrated that during healing, dimensional changes occur in the alveolar bone and in the BBW that may compromise the integrity of the peri-implant bone, leading to VBL and mucosal recession (MR), particularly in scenarios exhibiting a thin BBW. The preclinical evidence validated the fact that implants placed in the presence of a thin BBW, are more prone to exhibit major dimensional changes and VBL. Moreover, the clinical data supported that, in scenarios where dehiscence-type defects occur and are left for spontaneous healing, greater VBL and MR together with the occurrence of biologic complications are expected. Furthermore, the augmentation of dehiscence-type defects is associated with hard and soft tissue stability. PROMs were not reported. CONCLUSIONS Dimensional changes occur as result of implant placement in healed ridges that may lead to instability of the peri-implant hard and soft tissues. Sites presenting a thin BBW are more prone to exhibit major changes that may compromise the integrity of the buccal bone and may lead to biologic and esthetic complications.
Collapse
Affiliation(s)
- Alberto Monje
- Department of Periodontology and Oral Medicine, University of Michigan, Ann Arbor, Michigan, USA
- Department of Periodontology, Universitat Internacional de Catalunya, Barcelona, Spain
- Department of Periodontology, University of Bern, Bern, Switzerland
| | - Andrea Roccuzzo
- Department of Periodontology, University of Bern, Bern, Switzerland
- Department of Oral Maxillofacial Surgery, Copenaghen University Hospital (Rigshospitalet), Copenhagen, Denmark
| | - Daniel Buser
- School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Hom-Lay Wang
- Department of Periodontology and Oral Medicine, University of Michigan, Ann Arbor, Michigan, USA
| |
Collapse
|
4
|
Thu MK, Kang YS, Kwak JM, Jo YH, Han JS, Yeo ISL. Comparison between bone-implant interfaces of microtopographically modified zirconia and titanium implants. Sci Rep 2023; 13:11142. [PMID: 37429939 DOI: 10.1038/s41598-023-38432-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Accepted: 07/07/2023] [Indexed: 07/12/2023] Open
Abstract
The aim of this study was to investigate the surface characteristics and evaluate the bone-implant interfaces of injection molded zirconia implants with or without surface treatment and compare them with those of conventional titanium implants. Four different zirconia and titanium implant groups (n = 14 for each group) were prepared: injection-molded zirconia implants without surface treatment (IM ZrO2); injection-molded zirconia implants with surface treatment via sandblasting (IM ZrO2-S); turned titanium implants (Ti-turned); and titanium implants with surface treatments via sandblasting with large-grit particles and acid-etching (Ti-SLA). Scanning electron microscopy, confocal laser scanning microscopy, and energy dispersive spectroscopy were used to assess the surface characteristics of the implant specimens. Eight rabbits were used, and four implants from each group were placed into the tibiae of each rabbit. Bone-to-implant contact (BIC) and bone area (BA) were measured to evaluate the bone response after 10-day and 28-day healing periods. One-way analysis of variance with Tukey's pairwise comparison was used to find any significant differences. The significance level was set at α = 0.05. Surface physical analysis showed that Ti-SLA had the highest surface roughness, followed by IM ZrO2-S, IM ZrO2, and Ti-turned. There were no statistically significant differences (p > 0.05) in BIC and BA among the different groups according to the histomorphometric analysis. This study suggests that injection-molded zirconia implants are reliable and predictable alternatives to titanium implants for future clinical applications.
Collapse
Affiliation(s)
- Myint Kyaw Thu
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea
| | - Young Suk Kang
- 618th Medical Company (Dental Area Support)/Dental Health Activity-Korea, Camp Humphreys, APO, AP, 96297, USA
| | - Jeong Min Kwak
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea
| | - Ye-Hyeon Jo
- Dental Research Institute, Seoul National University, Seoul, 03080, Korea
| | - Jung-Suk Han
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea
| | - In-Sung Luke Yeo
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101, Daehak-ro, Jongro-gu, Seoul, 03080, Korea.
| |
Collapse
|
5
|
Monje A, Roccuzzo A, Buser D, Wang HL. Significance of buccal bone wall thickness on the fate of peri-implant hard and soft tissues: A systematic review. Clin Oral Implants Res 2023; 34:157-176. [PMID: 36626118 DOI: 10.1111/clr.14029] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2022] [Revised: 12/16/2022] [Accepted: 12/17/2022] [Indexed: 01/11/2023]
Abstract
BACKGROUND The significance of the association between the peri-implant buccolingual dimension (BLD) at the stage of implant placement and the occurrence of biological and esthetic complications is yet unknown. MATERIAL AND METHODS Systematic screening of electronic sources was carried out to identify clinical and preclinical studies reporting on the baseline BLD and/or buccal bone thickness (BBT) values. A secondary objective was to assess the effect of simultaneous grafting at sites with deficient or no buccal bone wall (BBW) at baseline. The primary outcome variables were BBT, BLD, and vertical bone loss (VBL) at re-evaluation. Moreover, radiographic, clinical- and patient-reported outcome measures (PROMs) were evaluated. RESULTS Overall, 12 clinical and four preclinical studies met the inclusion criteria. The clinical evidence demonstrated that during healing, dimensional changes occur in the alveolar bone and in the BBW that may compromise the integrity of bone around a dental implant. The preclinical evidence validated the fact that implants placed in the presence of thin BBW are more prone to exhibit major dimensional changes. Moreover, the clinical and preclinical data supported that in scenarios where dehiscence-type defects are left for spontaneous healing, greater VBL and mucosal recession (MR) together with the occurrence of biologic complications are expected. Furthermore, the augmentation of dehiscence-type defects is associated with hard and soft tissue stability. CONCLUSIONS Dimensional changes occur as a result of implant placement in healed ridges that may lead to VBL and MR. Thin BBW (≲2 mm) are prone to exhibit major postchanges that may compromise the integrity of the buccal bone, biologic and esthetic complications.
Collapse
Affiliation(s)
- Alberto Monje
- Department of Periodontology and Oral Medicine, University of Michigan, Ann Arbor, Michigan, USA.,Department of Periodontology, Universitat Internacional de Catalunya, Barcelona, Spain.,Department of Periodontology, University of Bern, Bern, Switzerland
| | - Andrea Roccuzzo
- Department of Periodontology, University of Bern, Bern, Switzerland
| | - Daniel Buser
- School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Hom-Lay Wang
- Department of Periodontology and Oral Medicine, University of Michigan, Ann Arbor, Michigan, USA
| |
Collapse
|
6
|
Duan C, Ye L, Zhang M, Yang L, Li C, Pan J, Wu Y, Cao Y. Clinical performance of zirconium implants compared to titanium implants: a systematic review and meta-analysis of randomized controlled trials. PeerJ 2023; 11:e15010. [PMID: 36949758 PMCID: PMC10026713 DOI: 10.7717/peerj.15010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Accepted: 02/16/2023] [Indexed: 03/19/2023] Open
Abstract
Purpose To quantitatively assess and compare the clinical outcomes, including survival rate, success rate, and peri-implant indices of titanium and zirconium implants in randomized controlled trials. Methods The electronic databases searched included the Cochrane Central Register of Controlled Trials (CENTRAL), Medline via Ovid, EMBASE, and Web of Science. Randomized controlled trials (RCTs) that reported the effects of zirconium implants on primary outcomes, such as survival rate, success rate, marginal bone loss (MBL), and probing pocket depth (PPD), compared to titanium implants were included in this review. Two reviewers independently screened and selected the records, assessed their quality, and extracted the data from the included studies. Results A total of four studies from six publications reviewed were included. Two of the comparative studies were assessed at minimal risk of bias. Zirconium implants may have a lower survival rate (risk ratio (RR) = 0.91, CI [0.82-1.02], P = 0.100, I 2 = 0%) and a significantly lower success rate than titanium implants (RR = 0.87, CI [0.78-0.98], P = 0.030, I 2 = 0%). In addition, there was no difference between the titanium and zirconium implants in terms of MBL, PPD, bleeding on probing (BOP), plaque index (PI), and pink esthetic score (PES) (for MBL, MD = 0.25, CI [0.02-0.49], P = 0.033, I 2 = 0%; for PPD, MD = -0.07, CI [-0.19-0.05], P = 0.250, I 2 = 31%). Conclusion Zirconium implants may have higher failure rates due to their mechanical weakness. Zirconium implants should be strictly assessed before they enter the market. Further studies are required to confirm these findings.
Collapse
Affiliation(s)
- Chengchen Duan
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China College of Stomatology, Sichuan University, Chengdu, China
| | - Li Ye
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Oral and Maxillofacial Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Mengyun Zhang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China College of Stomatology, Sichuan University, Chengdu, China
| | - Lei Yang
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, West China College of Stomatology, Sichuan University, Chengdu, China
| | - Chunjie Li
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Head and Neck Oncology, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Jian Pan
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Oral and Maxillofacial Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yingying Wu
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Oral implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Yubin Cao
- State Key Laboratory of Oral Diseases, National Clinical Research Center for Oral Diseases, Department of Oral and Maxillofacial Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| |
Collapse
|
7
|
Abstract
Surface characteristics are an important factor for long-term clinical success of dental implants. Alterations of implant surface characteristics accelerate or improve osseointegration by interacting with the physiology of bone healing. Dental implant surfaces have been traditionally modified at the microlevel. Recently, researchers have actively investigated nano-modifications in dental implants. This review explores implant surface modifications that enhance biological response at the interface between a bone and the implant.
Collapse
Affiliation(s)
- In-Sung Luke Yeo
- Department of Prosthodontics, School of Dentistry and Dental Research Institute, Seoul National University, 101 Daehak-Ro, Jongro-Gu, Seoul 03080, Korea.
| |
Collapse
|
8
|
Zirconia versus Titanium Implants: 8-Year Follow-Up in a Patient Cohort Contrasted with Histological Evidence from a Preclinical Animal Model. MATERIALS 2022; 15:ma15155322. [PMID: 35955254 PMCID: PMC9369473 DOI: 10.3390/ma15155322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 07/18/2022] [Accepted: 07/29/2022] [Indexed: 02/04/2023]
Abstract
Zirconia ceramic (ZC) implants are becoming more common, but comparisons between preclinical histology and long-term clinical trials are rare. This investigation comprised (1) 8-year clinical follow-up of one-piece ZC or titanium (Ti) implants supporting full overdentures and (2) histomorphometric analysis of the same implants in an animal model, comparing implants with various surface treatments. Methods: (1) Clinical trial: 24 completely edentulous participants (2 groups of N = 12) received 7 implants (one-piece ball-abutment ZC or Ti; maxilla N = 4, mandible N = 3) restored with implant overdentures. Outcomes after 8-years included survival, peri-implant bone levels, soft-tissue responses, and prosthodontic issues. (2) Preclinical trial: 10 New Zealand sheep received 4 implants bilaterally in the femoral condyle: Southern Implants ZC or Ti one-piece implants, identical to the clinical trial, and controls: Southern ITC® two-piece implants with the same surface or Nobel (NBC) anodised (TiUnite™) surface. %Bone-implant contact (%BIC) was measured after 12 weeks of unloaded healing. Results: 8 of 24 participants (33%) of an average age of 75 ± 8 years were recalled; 21% of original participants had died, and 46% could not be contacted. 80.4% of implants survived; excluding palatal sites, 87.5% of Ti and 79% of ZC implants survived. All failed implants were in the maxilla. Three ZC implants had fractured. Bone loss was similar for Ti vs. ZC; pocket depths (p = 0.04) and attachment levels (p = 0.02) were greater for Ti than ZC implants. (1.7 ± 1.6 mm vs. 1.6 ± 1.3 mm). All implants in sheep femurs survived. %BIC was not statistically different for one-piece blasted surface Ti (80 ± 19%) versus ZC (76 ± 20%) or ITC® (75 ± 16 mm); NBC had significantly higher %BIC than ITC (84 ± 17%, p = 0.4). Conclusion: Short-term preclinical results for ZC and Ti one-piece implants showed excellent bone-implant contact in unloaded femoral sites. This differed from the long-term clinical results in older-aged, edentulous participants. While ZC and Ti implants showed equivalent performance, the risks of peri-implantitis and implant loss in older, completely edentulous patients remain a significant factor.
Collapse
|
9
|
Rodrigues Pais Alves MF, Figueira Vaz Fernandes MH, Macário Barboza Daguano JK, Dorión Rodas AC, Vasconcelos Amarante JE, Santos CD. Effect of the surface finish on the mechanical properties and cellular adhesion in (Ce,Y)-TZP/Al 2O 3 ceramic composites for denture implants. J Mech Behav Biomed Mater 2022; 134:105363. [PMID: 35850038 DOI: 10.1016/j.jmbbm.2022.105363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Revised: 07/07/2022] [Accepted: 07/09/2022] [Indexed: 11/28/2022]
Abstract
Ceramic composites based on (Ce, Y)-TZP/Al2O3 system have great potential for applications as dental implants due to their unusually great balance between good mechanical properties and resistance to hydrothermal degradation. Surface roughness plays an important role in controlling these properties, but few studies have investigated the relationship between cytocompatibility and surface roughness, at levels considered moderate and low, comparable to titanium implants. In this work, bending strength, hydrothermal degradation and biological evaluation of a ceramic composite based on (Ce,Y)-TZP/Al2O3 system were investigated as a function of surface roughness. Compacted samples were sintered at 1500 °C - 2h and then submitted to different surface treatments: Group 1 composed of samples with smooth surfaces, Group 2 and Group 3 composed of rough surfaces (grinded with 15 μm or 45 μm diamond sandpaper, respectively. Samples were characterized by X-ray diffraction, scanning electron microscopy, contact angle and optical profilometry and then subjected to hydrothermal degradation tests in autoclave (134 °C - 2 bar) using artificial saliva. The Piston-on-three-balls (P-3B) testing was used to determine flexural strength. To assess indirect cytotoxicity, samples were immersed in the culture medium for NIH-3T3 cells for 72 h. Furthermore, cell adhesion and proliferation were investigated using MG63 cells (human osteosarcoma) after 3, 7, 14, and 21 days of culture. Cytotoxicity, adhesion, and cell proliferation were examined by the Methyl Tetrazolium salt (MTS) and Alizarin Red, using a confocal laser microscope. The results indicated that the materials have high resistance to degradation. Furthermore, the (Ce,Y)-TZP/Al2O3 composites are not cytotoxic. The flexural strength of the composites was 913 ± 103 MPa in samples presenting original (smooth) surface, however, a reduction in the order of 17% was observed in samples containing rough surfaces. The rougher samples show the best cellular adhesion and proliferation, leading to the formation of a mineralized matrix after 21 days. These results clearly suggest that the new (Ce,Y)-TZP/Al2O3 brand is strong and highly biocompatible and warrants further study.
Collapse
Affiliation(s)
- Manuel Fellipe Rodrigues Pais Alves
- UERJ-FAT - Faculty of Technology, Rio de Janeiro State University, Rod. Presidente Dutra, Km 298, Resende, RJ, 27537-000, Brazil; CICECO - Aveiro Institute of Materials, Department of Materials and Ceramic Engineering, University of Aveiro, Aveiro, 3810-193, Portugal
| | | | - Juliana Kelmy Macário Barboza Daguano
- CECS - Center for Engineering, Modeling and Applied Social Sciences, Federal University of ABC, Alameda da Universidade, s/n - Anchieta, São Bernardo do Campo, SP, 09606-045, Brazil; CTI - Center for Information Technology Renato Archer, Dom Pedro I Highway (SP-65), Km 143,6 - Chácaras Campos dos Amarais, Campinas, SP, 13069-901, Brazil
| | - Andrea Cecilia Dorión Rodas
- CECS - Center for Engineering, Modeling and Applied Social Sciences, Federal University of ABC, Alameda da Universidade, s/n - Anchieta, São Bernardo do Campo, SP, 09606-045, Brazil
| | - José Eduardo Vasconcelos Amarante
- UFF- Faculty of Dentistry of the Health Institute of Nova Friburgo, Fluminense Federal University, Rua Dr. Silvio Henrique Braune, 22 Centro, Nova Friburgo, RJ, 28625-650, Brazil
| | - Claudinei Dos Santos
- UERJ-FAT - Faculty of Technology, Rio de Janeiro State University, Rod. Presidente Dutra, Km 298, Resende, RJ, 27537-000, Brazil; CICECO - Aveiro Institute of Materials, Department of Materials and Ceramic Engineering, University of Aveiro, Aveiro, 3810-193, Portugal.
| |
Collapse
|
10
|
Cao X, Wang C, Yuan D, Chen S, Wang X. The effect of implants loaded with stem cells from human exfoliated deciduous teeth on early osseointegration in a canine model. BMC Oral Health 2022; 22:238. [PMID: 35715777 PMCID: PMC9206344 DOI: 10.1186/s12903-022-02264-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 06/02/2022] [Indexed: 11/17/2022] Open
Abstract
Background This in vivo experimental study investigated the effect of stem cells from human exfoliated deciduous teeth (SHEDs) on early osteogenesis around implants. Methods In four healthy adult male Beagle dogs, the left mandibular received implants and SHED as the experimental group, and the right mandibular received implants and phosphate-buffered saline as the control group. The Beagle dogs were randomly divided into groups A and B, which were sacrificed at 2 and 4 weeks after implantation. Micro-computed tomography and histological analysis were used to investigate the effect of SHED-loading on the early osseointegration around the implants. Results The total bone-to-implant contact (BIC%) and interthread bone improved significantly. The analysis of the bone volume fraction and trabecular thickness showed that the bone trabecula around the implants in the SHEDs group was thicker and denser than that in the control group, suggesting a better osseointegration. Conclusions The application of implants pre-adhered with SHEDs improved and accelerated early osseointegration around the implant, resulting in thicker and denser trabecular bone.
Collapse
Affiliation(s)
- Xu Cao
- Laboratory of Biomaterials and Biomechanics, Beijing Key Laboratory of Tooth Regeneration and Function Reconstruction, Beijing Stomatological Hospital, Capital Medical University, Beijing, China
| | - Caiyun Wang
- Laboratory of Biomaterials and Biomechanics, Beijing Key Laboratory of Tooth Regeneration and Function Reconstruction, Beijing Stomatological Hospital, Capital Medical University, Beijing, China
| | - Dingxiang Yuan
- Laboratory of Biomaterials and Biomechanics, Beijing Key Laboratory of Tooth Regeneration and Function Reconstruction, Beijing Stomatological Hospital, Capital Medical University, Beijing, China
| | - Su Chen
- Laboratory of Biomaterials and Biomechanics, Beijing Key Laboratory of Tooth Regeneration and Function Reconstruction, Beijing Stomatological Hospital, Capital Medical University, Beijing, China
| | - Xin Wang
- Laboratory of Biomaterials and Biomechanics, Beijing Key Laboratory of Tooth Regeneration and Function Reconstruction, Beijing Stomatological Hospital, Capital Medical University, Beijing, China.
| |
Collapse
|
11
|
Heng L, Kim JS, Song JH, Mun SD. A Review on Surface Finishing Techniques for Difficult-to-Machine Ceramics by Non-Conventional Finishing Processes. MATERIALS 2022; 15:ma15031227. [PMID: 35161171 PMCID: PMC8838235 DOI: 10.3390/ma15031227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 01/18/2022] [Accepted: 01/25/2022] [Indexed: 02/05/2023]
Abstract
Ceramics are advanced engineering materials in which have been broadly used in numerous industries due to their superior mechanical and physical properties. For application, the industries require that the ceramic products have high-quality surface finishes, high dimensional accuracy, and clean surfaces to prevent and minimize thermal contact, adhesion, friction, and wear. Ceramics have been classified as difficult-to-machine materials owing to their high hardness, and brittleness. Thus, it is extremely difficult to process them with conventional finishing processes. In this review, trends in the development of non-conventional finishing processes for the surface finishing of difficult-to-machine ceramics are discussed and compared to better comprehend the key finishing capabilities and limitations of each process on improvements in terms of surface roughness. In addition, the future direction of non-conventional finishing processes is introduced. This review will be helpful to many researchers and academicians for carrying out additional research related to the surface finishing techniques of ceramics for applications in various fields.
Collapse
Affiliation(s)
- Lida Heng
- Department of Mechanical Design Engineering, Jeonbuk National University, Jeonju 54896, Korea;
| | - Jeong Su Kim
- Department of Energy Storage/Conversion Engineering of Graduate School, Jeonbuk National University, Jeonju 54896, Korea;
| | - Jun Hee Song
- Department of Energy Storage/Conversion Engineering of Graduate School, Jeonbuk National University, Jeonju 54896, Korea;
- Division of Convergence Technology Engineering, Jeonbuk National University, Jeonju 54896, Korea
- Correspondence: (J.H.S.); (S.D.M.); Tel.: +82-63-472-2881 (J.H.S.); +82-63-270-4762 (S.D.M.)
| | - Sang Don Mun
- Department of Mechanical Design Engineering, Jeonbuk National University, Jeonju 54896, Korea;
- Department of Energy Storage/Conversion Engineering of Graduate School, Jeonbuk National University, Jeonju 54896, Korea;
- Correspondence: (J.H.S.); (S.D.M.); Tel.: +82-63-472-2881 (J.H.S.); +82-63-270-4762 (S.D.M.)
| |
Collapse
|