1
|
Attik N, Richert R, Garoushi S. Biomechanics, Bioactive and Biomimetic Philosophy in Restorative Dentistry ̶ Quo vadis? J Dent 2024:105036. [PMID: 38702037 DOI: 10.1016/j.jdent.2024.105036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2024] [Revised: 04/29/2024] [Accepted: 04/30/2024] [Indexed: 05/06/2024] Open
Abstract
INTRODUCTION In recent years, restorative dentistry has embraced various techniques, including direct, semi-direct, and indirect restorations, to address the replacement of lost tooth tissue. The focus has been on integrating the principles of Biomechanics, Bioactivity, and Biomimicry (3-Bio) as key drivers behind these innovations. METHODS Three enthusiastic researchers in dental materials have come together to collaborate on writing a concise opinion article addressing the three aspects of restorative dental materials: Biomechanics, Bioactivity, and Biomimetic principles. Their aim is to provide readers with relevant information on the 3-Bio concept, offering insights into the innovative approaches shaping modern restorative dentistry. RESULTS Developing restorative materials with interactive properties aligned with the 3-Bio concept poses a significant challenge. Currently, dentistry lacks a comprehensive system in this regard. Though, the development of dental materials based on the 3-Bio concept could potentially elicit positive mechanical and biological responses in targeted tooth tissues. CONCLUSION Assessing several parameters through a battery of in vitro and in silico assays could help in tailoring the different aspects of the 3-Bio concept, spanning from bioactivity to biomimetics via biomechanics. This approach could allow the prediction and translation of the clinical performance of the assessed restorative materials. CLINICAL SIGNIFICANCE The findings of this opinion article highlight that the development of restorative materials aligned with the 3-Bio concept could enhance the management of dental defects and extend the longevity of bonded restorations, thereby improving patient care through tissue preservation. The authors believe that more collective efforts between clinicians, researchers, and even industrial partners are required to fully understand the correlation between bioactive behaviour, biomechanical limitations, and biomimetics to provide suitable restorative materials for specific clinical applications.
Collapse
Affiliation(s)
- Nina Attik
- Univ Lyon, Université Claude Bernard Lyon 1, Faculté d'Odontologie, 69008, Lyon, France; Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, F-69622, Villeurbanne, France.
| | - Raphael Richert
- Univ Lyon, Université Claude Bernard Lyon 1, Faculté d'Odontologie, 69008, Lyon, France; Service d'Odontologie, Hospices Civils de Lyon, 69007, Lyon, France
| | - Sufyan Garoushi
- Department of Biomaterials Science and Turku Clinical Biomaterials Center - TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| |
Collapse
|
2
|
Guler MS, Guler C, Belduz Kara N, Odabasi D, Bekci ML. The stress distribution of a primary molar tooth restored with stainless steel crown using different luting cements. BMC Oral Health 2024; 24:269. [PMID: 38395853 PMCID: PMC10893635 DOI: 10.1186/s12903-024-04038-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Accepted: 02/16/2024] [Indexed: 02/25/2024] Open
Abstract
BACKGROUND The aim of this study is to evaluate the stress distributions of a primary molar tooth restored with a stainless steel crown (SSC) using resin and glass ionomer luting cements by Finite Element Analysis (FEA). METHODS Original DICOM data of a primary molar was used to create a 3D model. One model was prepared as a tooth model with SSC. A 30 μm cement layer was used in model. Two different luting cements were tested in the study: self-cure adhesive resin cement, and glass ionomer cement. Vertical and oblique loads of 330 N were applied to simulate maximum bite force and lateral forces in the occlusal contact areas of the models. Maximum von Mises stress values in the models were evaluated as MPa. RESULTS The maximum von Mises stress value was observed in the force application and general occlusal contact areas for all models. The maximum von Mises stress values were higher in the tooth model with SSC using self-cure adhesive resin cement (478.09 MPa and 214.62 MPa) than in the tooth model with SSC using glass ionomer cement (220.06 MPa and 198.72 MPa) in both vertical and oblique loading, respectively. CONCLUSIONS Depending on the magnitude of the bite force on the SSC, fracture of the luting cement materials could occur if the stress exceeds the endurance limit of the luting cement. Cementation with glass ionomer cement may help to reduce stress levels in SSC restorations of primary molars in children.
Collapse
Affiliation(s)
- Mehmet Sami Guler
- Department of Machinery and Metal Technologies, Vocational School of Technical Sciences, Ordu University, Ordu, Turkey
| | - Cigdem Guler
- Department of Pediatric Dentistry, Faculty of Dentistry, Ordu University, Ordu, Turkey
| | - Nihal Belduz Kara
- Department of Pediatric Dentistry, Faculty of Dentistry, Ordu University, Ordu, Turkey
| | - Didem Odabasi
- Department of Pediatric Dentistry, Faculty of Dentistry, Ordu University, Ordu, Turkey.
| | - Muhammed Latif Bekci
- Department of Machinery and Metal Technologies, Vocational School of Technical Sciences, Ordu University, Ordu, Turkey
| |
Collapse
|
3
|
Babaei B, Prusty BG. Enhancing the mechanical stability of restored teeth with interfacial cracks: Finite element analysis. J Mech Behav Biomed Mater 2023; 148:106191. [PMID: 37847958 DOI: 10.1016/j.jmbbm.2023.106191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 10/09/2023] [Accepted: 10/12/2023] [Indexed: 10/19/2023]
Abstract
OBJECTIVES This study aims to enhance the mechanical stability of restored molar teeth with class II occlusal-distal (OD) cavities. We seek to achieve this goal through a comprehensive investigation of three primary factors: (1) the choice of restoration material properties, (2) internal cavity geometries, and (3) the impact of double-layered restoration configurations. METHODS To achieve our objectives, we initiated by creating two-dimensional (2D) models of restored teeth featuring class II OD cavities, utilizing scanned and segmented images of maxillary molar teeth. We drew 2D profiles of dentine and enamel, which were then imported into finite element analysis (FEA) software. To explore various cavity geometries, we implemented a total of thirteen different designs, encompassing straight, oblique, grooved, curved, and double-layered configurations. We utilized a semi-circular stone to simulate the application of contact load on the restored tooth. We applied identical boundary conditions and contact loading across all models. To assign material properties, we developed a Python code, enabling the automatic assignment of seven elastic moduli ranging from 2 GPa to 26 GPa to the restoration materials. Meanwhile, constant material properties were assigned to the enamel and dentine. In total, we conducted 133 FEA simulations to comprehensively analyse the effects of the aforementioned factors on the strength and performance of restored molar teeth. RESULTS Our analysis revealed two key factors significantly influencing the mechanical resistance of treated teeth, particularly in the presence of a crack or debonding: (1) the marginal geometry of the OD cavity and (2) the elastic modulus of the restorative material. However, altering the internal cavity angle and implementing a double-layered restoration did not significantly influence the restored tooth's overall strength and performance in the face of crack or debonding situations. SIGNIFICANCE The findings of this study have substantial implications for designing and restoring class II OD cavities to enhance resistance to cracks or debonding. The use of curved marginal geometries in restoration design can significantly improve fracture resistance, with double-curved geometries reducing stress concentrations by approximately 43% compared to straight cavities. These results offer valuable guidance for strengthening the structural integrity of restored teeth, calling for further experimental investigations to explore practical applications and benefits.
Collapse
Affiliation(s)
- Behzad Babaei
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia.
| | - B Gangadhara Prusty
- School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, 2052, Australia; ARC Centre for Automated Manufacture of Advanced Restorations, School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, NSW, Australia
| |
Collapse
|
4
|
Lin F, Feng X, Ordinola-Zapata R, VanHeel B, Fok ASL. Load capacity and fracture modes of instrumented tooth roots under axial compression. Dent Mater 2023; 39:938-945. [PMID: 37648562 DOI: 10.1016/j.dental.2023.08.177] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Accepted: 08/23/2023] [Indexed: 09/01/2023]
Abstract
OBJECTIVE To investigate the influences of root canal instrumentation on the load capacity and fracture modes of tooth roots under axial compression by performing mechanical tests and finite element analysis (FEA). METHODS Thirty bovine incisor roots were trimmed into cylinders of 5.0 mm diameter. They were randomly divided into two groups, one with root canals instrumented to ∼2.0 mm in diameter, and one without instrumentation. The specimens were fractured under uniaxial compression at a crosshead speed of 0.2 mm/min, and then micro-CT was used to reveal the fracture patterns in three dimensions. FEA was further performed, using the extended finite element method (XFEM), to compare the compression-induced stress distributions and the initiation and propagation of root fractures in both groups. RESULTS The mean fracture load of the non-instrumented group (2334 ± 436 N) was statistically significantly higher than that of the instrumented group (1857 ± 377 N) (p < 0.01). Three types of root fractures were identified according to the path and length of the cracks: end-face crack, partial-length crack, and full-length crack. As to the fracture modes, the incidence of partial-length root fracture was the highest in both groups (60% for the non-instrumented group and 53.3% for the instrumented group), followed by that of full-length fracture (26.7% and 40%, respectively) and then end-face fracture (13.3% and 6.7%, respectively). The percentage of full-length fracture was slightly higher in the instrumented group. FEA showed that the compression induced higher Tresca stresses but lower maximum principal stresses in the canal walls of the instrumented group. The XFEM simulations predicted that the fracture of both groups initiated from the outer root surface near an end face and propagated axially to the middle third of the root and radially towards the root canal. These numerical results agreed well with our experimental findings. SIGNIFICANCE Within the limitation of this study, it was found that root canal instrumentation could significantly decrease the load capacity of tooth roots and potentially increase their susceptibility to full-length root fracture under uniaxial compression.
Collapse
Affiliation(s)
- Fei Lin
- Department of Cariology and Endodontology, Peking University School and Hospital of Stomatology & National Center for Stomatology & National Clinical Research Center for Oral Diseases & National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing 100081, China
| | - Xiqiao Feng
- Institute of Biomechanics and Medical Engineering, Department of Engineering Mechanics, Tsinghua University, Beijing 100084, China
| | - Ronald Ordinola-Zapata
- Division of Endodontics, Department of Restorative Sciences, School of Dentistry, University of Minnesota, Minneapolis, MN 55455, USA
| | - Bonita VanHeel
- Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, MN 55455, USA
| | - Alex S L Fok
- Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, MN 55455, USA.
| |
Collapse
|
5
|
Ni J, Xu L, Lin Y, Lai D, Huang X. Effects on different full-coverage designs and materials of crack propagation in first mandibular molar: an extended finite element method study. Front Bioeng Biotechnol 2023; 11:1222060. [PMID: 37650043 PMCID: PMC10464904 DOI: 10.3389/fbioe.2023.1222060] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2023] [Accepted: 08/07/2023] [Indexed: 09/01/2023] Open
Abstract
Objectives: This study aims to investigate the biomechanical properties of fracture resistance in cracked teeth using five different full-coverage restorations made of three different materials. Materials and Methods: A 3D model of a mandibular first molar was created to design five different full-coverage repair models: crown, crown with composite resin filling inside, occlusal veneer, occlusal veneer with composite resin filling inside and onlay. These repair models were fabricated using three different materials, namely, zirconia, lithium disilicate (LDS), and a hybrid polymer-infiltrated ceramic network material (PIC). In total, 15 repair models were tested using the extended finite element method (XFEM), with an occlusal load of 5000 N applied slowly to the occlusal surface of the restoration. The analysis of stress distribution in the restoration and dentin crack line was conducted to measure and record the crack initial load on the restoration and dentin. Results: The results showed that restorations on the occlusal surface significantly improved crack resistance, with zirconia exhibiting superior fracture resistance among the materials tested. Restorations of crown with composite resin filling inside demonstrated the highest resistance to fracture, while occlusal veneers showed the lowest. MPS concentration was observed at the interface between the restoration and dentin and at the root bifurcation, with the highest values at the top of crack development. Dentin covered by oxidized restorations had the highest displacement, while PIC restorations exhibited the lowest. Pulp analysis revealed selective MPS concentration and strain patterns in models with zirconia restorations and onlay, with pronounced pulp displacement in zirconia restorations and onlay. Enamel analysis indicated larger MPS values and displacements in zirconia restoration models and onlay, with higher strain in onlay. Restoration played a crucial role in protecting the tooth, with crack propagation initial loads in dentin surpassing restorations in experimental groups. Conclusion: This study confirms that full-coverage restorations significantly increased the fracture resistance of cracked teeth, with zirconia restorations significantly protecting the underlying cracked tooth. Elimination of fracture lines in the restoration design can improve fracture resistance in cracked teeth. The findings have implications for dental prosthetic design and clinical practice.
Collapse
Affiliation(s)
| | | | | | | | - Xiaohong Huang
- Department of Stomatology, The First Affiliated Hospital, Fujian Medical University, Fuzhou, China
| |
Collapse
|
6
|
Dorado S, Arias A, Jimenez-Octavio JR. Biomechanical Modelling for Tooth Survival Studies: Mechanical Properties, Loads and Boundary Conditions-A Narrative Review. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7852. [PMID: 36363451 PMCID: PMC9657341 DOI: 10.3390/ma15217852] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 11/02/2022] [Accepted: 11/04/2022] [Indexed: 06/16/2023]
Abstract
Recent biomechanical studies have focused on studying the response of teeth before and after different treatments under functional and parafunctional loads. These studies often involve experimental and/or finite element analysis (FEA). Current loading and boundary conditions may not entirely represent the real condition of the tooth in clinical situations. The importance of homogenizing both sample characterization and boundary conditions definition for future dental biomechanical studies is highlighted. The mechanical properties of dental structural tissues are presented, along with the effect of functional and parafunctional loads and other environmental and biological parameters that may influence tooth survival. A range of values for Young's modulus, Poisson ratio, compressive strength, threshold stress intensity factor and fracture toughness are provided for enamel and dentin; as well as Young's modulus and Poisson ratio for the PDL, trabecular and cortical bone. Angles, loading magnitude and frequency are provided for functional and parafunctional loads. The environmental and physiological conditions (age, gender, tooth, humidity, etc.), that may influence tooth survival are also discussed. Oversimplifications of biomechanical models could end up in results that divert from the natural behavior of teeth. Experimental validation models with close-to-reality boundary conditions should be developed to compare the validity of simplified models.
Collapse
Affiliation(s)
- Saúl Dorado
- Department of Mechanical Engineering, Escuela Técnica Superior de Ingeniería ICAI, Universidad Pontificia Comillas, 28015 Madrid, Spain
| | - Ana Arias
- Department of Conservative and Prosthetic Dentistry, School of Dentistry, Complutense University, 28040 Madrid, Spain
| | - Jesus R. Jimenez-Octavio
- Instituto de Investigación Tecnológica, Escuela Técnica Superior de Ingeniería ICAI, Universidad Pontificia Comillas, 28015 Madrid, Spain
| |
Collapse
|
7
|
Vertical root fracture resistance and crack formation of root canal-treated teeth restored with different post-luting systems. Odontology 2022; 110:719-725. [PMID: 35523910 PMCID: PMC9463252 DOI: 10.1007/s10266-022-00709-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 04/11/2022] [Indexed: 11/26/2022]
Abstract
The aim was to investigate the vertical root fracture (VRF) resistance and crack formation of root canal-treated teeth restored with different post-luting systems. Human maxillary lateral incisors of similar size were decoronated, assigned to five groups (n = 18, power = 0.9) and embedded in acrylic blocks with artificial periodontal ligament. After root canal filling, post spaces were prepared to place coated fiber-reinforced composite (FRC) or sandblasted titanium (Ti) posts of the same shape and size. Half of the posts were zinc phosphate cemented (C), while the other half was adhesively luted (A). Untreated teeth served as control. After thermal cycling and staircase loading in a chewing simulator, the crack formation on the root dentin surface was microscopically examined and classified as no defect, craze line, vertical crack, and horizontal crack. Subsequently, the samples were loaded until root fracture. Data were analyzed by one-way ANOVA, Tukey’s test, and Fisher’s exact test. All samples survived the chewing simulation without VRF, but crack formation was significantly different between the groups (P = 0.009). The control showed significantly fewer defects than FRC/C, Ti/C, and Ti/A (P = 0.001, P = 0.008, P = 0.008, respectively). FRC/C showed the highest incidence of vertical cracks. FRC/A had the lowest incidence of defects. There was no significant difference in VRF resistance between the groups (P = 0.265). Adhesively luted FRC posts did not increase VRF resistance but reduced the risk of defects. Most defects were craze lines and vertical root cracks.
Collapse
|
8
|
Ordinola-Zapata R, Lin F, Nagarkar S, Perdigão J. A critical analysis of research methods and experimental models to study the load capacity and clinical behavior of the root filled teeth. Int Endod J 2022; 55 Suppl 2:471-494. [PMID: 35263455 PMCID: PMC9314814 DOI: 10.1111/iej.13722] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 03/04/2022] [Indexed: 12/04/2022]
Abstract
The prognosis of root‐filled teeth depends not only on a successful root canal treatment but also on the restorative prognosis. This critical review discusses the advantages and limitations of various methodologies used to assess the load capacity or clinical survivability of root‐filled teeth and restorations. These methods include static loading, cyclic loading, finite element analysis and randomized clinical trials. In vitro research is valuable for preclinical screening of new dental materials or restorative modalities. It also can assist investigators or industry to decide whether further clinical trials are justified. It is important that these models present high precision and accuracy, be reproducible, and present adequate outcomes. Although in vitro models can reduce confounding by controlling important variables, the lack of clinical validation (accuracy) is a downside that has not been properly addressed. Most importantly, many in vitro studies did not explore the mechanisms of failure and their results are limited to rank different materials or treatment modalities according to the maximum load capacity. An extensive number of randomized clinical trials have also been published in the last years. These trials have provided valuable insight on the survivability of the root‐filled tooth answering numerous clinical questions. However, trials can also be affected by the selected outcome and by intrinsic and extrinsic biases. For example, selection bias, loss to follow‐up and confounding. In the clinical scenario, hypothesis‐based studies are preferred over observational and retrospective studies. It is recommended that hypothesis‐based studies minimize error and bias during the design phase.
Collapse
Affiliation(s)
- Ronald Ordinola-Zapata
- Division of Endodontics, Department of Restorative Sciences, School of Dentistry, University of Minnesota, Minneapolis, MN, 55455, USA
| | - Fei Lin
- Department of Cariology and Endodontology, Peking University School and Hospital of Stomatology, Beijing, 100081, China.,Minnesota Dental Research Center for Biomaterials and Biomechanics, School of Dentistry, University of Minnesota, Minneapolis, MN, 55455, USA
| | - Sanket Nagarkar
- Park Dental Group, Minneapolis, Minnesota, and Clinical Research Assistant Professor (affiliated), Department of Restorative Sciences, University of Minnesota, Minneapolis, Minnesota, USA
| | - Jorge Perdigão
- Division of Operative Dentistry, Department of Restorative Sciences, University of Minnesota, Minneapolis, Minnesota, USA
| |
Collapse
|