1
|
Wada K, Wada J, Uctasli MB, Uctasli S, Yavuz Y, Iwamoto T, Vallittu PK, Garoushi S, Lassila L. Impact of restorative material on fracture behaviors of class II restoration in endodontically treated deciduous molars. Dent Mater J 2024; 43:738-745. [PMID: 39198175 DOI: 10.4012/dmj.2024-067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2024]
Abstract
The purpose of this study was to investigate the fracture behavior of endodontically treated (ET) deciduous molar when directly restored with different restorative materials in Class II (MO) cavities in comparison with permanent teeth. MO cavities were prepared with 2.4-2.5 mm and 1.9-2.0 mm in buccolingual width, and mesiodistal width of each cavity walls, respectively, followed by direct restoration with different materials: resin-modified glass ionomer cement (RMGIC), composite resin (CR), and composite resin containing 25% short glass-fiber (SFRC). All specimens were subjected to mechanical loading tests at a speed of 1 mm/min and evaluated fracture resistance and fracture modes. A one-way ANOVA followed by a Tukey multiple comparisons analysis was used. Deciduous-SFRC (3,310.5±396.2 N) were significantly higher fracture resistance than permanent-RMGIC (1,633.8±346.8 N) (p<0.001), and permanent-CR (1,400.0±381.3 N) (p<0.001). For the direct restoration of MO cavity after endodontic treatment, SFRC demonstrated its promising performance in load-bearing capacity and failure mode, especially in ET deciduous molars.
Collapse
Affiliation(s)
- Kanae Wada
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre (TCBC), Institute of Dentistry, University of Turku
- Department of Pediatric Dentistry/Special Needs Dentistry, Tokyo Medical and Dental University (TMDU)
| | - Junichiro Wada
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre (TCBC), Institute of Dentistry, University of Turku
- Department of Advanced Prosthodontics, Tokyo Medical and Dental University (TMDU)
| | - Mine Betul Uctasli
- Department of Restorative Dentistry, Faculty of Dentistry, University of Gazi
| | - Sadullah Uctasli
- Department of Prosthodontics, Faculty of Dentistry, University of Ankara
| | - Yasemin Yavuz
- Restorative Dentistry, Faculty of Dentistry, Harran University
| | - Tsutomu Iwamoto
- Department of Pediatric Dentistry/Special Needs Dentistry, Tokyo Medical and Dental University (TMDU)
| | - Pekka K Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre (TCBC), Institute of Dentistry, University of Turku
- Welfare District of South-West Finland
| | - Sufyan Garoushi
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre (TCBC), Institute of Dentistry, University of Turku
| | - Lippo Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterials Centre (TCBC), Institute of Dentistry, University of Turku
| |
Collapse
|
2
|
Garoushi S, Peltola T, Siekkinen M, Hupa L, Vallittu PK, Lassila L, Säilynoja E. Retention of strength and ion release of some restorative materials. Odontology 2024:10.1007/s10266-024-01010-3. [PMID: 39322811 DOI: 10.1007/s10266-024-01010-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Accepted: 09/19/2024] [Indexed: 09/27/2024]
Abstract
This study aimed to investigate the retention of strength in accelerated aging condition and ion release from an experimental fiber-reinforced bioactive flowable composite resin (Bio-SFRC), comparing it with various commercially available ion-releasing materials. The flexural strength of Bio-SFRC and other materials (Biodentine, TheraCal LC, Fuji II LC and Surefil one) was evaluated (n = 8) before and after hydrothermal accelerated aging. Ion concentrations of silica and phosphorus were measured after 1, 2, 3, 4, 7, 10, 14, and 21 days of specimen immersion in simulated body fluids (SBF) using UV-Vis spectrometry. In addition, ion release and pH change were studied in a continuous dynamic system in SBF over a period of 72 h. SEM and EDS were used to evaluate the microstructure on the top surface of the materials after SBF immersion. Data were statistically analyzed using variance ANOVA analysis (p = 0.05). Bio-SFRC showed higher flexural strength before (134.9 MPa) and after (63.1 MPa) hydrothermal aging compared to other tested materials (p < 0.05). Flexural strength significantly decreased after aging (p < 0.05) except for Fuji II LC which showed no significant differences. Ion release data showed that experimental Bio-SFRC slowly released phosphate ions. Biodentine and TheraCal LC had the strongest ability to form calcium phosphate precipitation on the material surface. Phosphate ion release cannot be detected clearly from these materials. Surefil one and Fuji II LC were more stable materials without any observable ion release. The advantages of fiber containing structure and slow release of ions suggest that experimental Bio-SFRC is a promising bioactive material to provide ions for mineralization of surrounding tissues, and keeping the durability of the materials at higher level than that of other tested materials.
Collapse
Affiliation(s)
- Sufyan Garoushi
- Department of Biomaterials Science and Turku Clinical Biomaterial Center-TCBC, Institute of Dentistry, University of Turku, Turku, Finland.
| | - Timo Peltola
- Research Development and Production Department, Stick Tech Ltd-Member of GC Group, Turku, Finland
| | - Minna Siekkinen
- Johan Gadolin Process Chemistry Centre, Åbo Akademi University, Turku, Finland
| | - Leena Hupa
- Johan Gadolin Process Chemistry Centre, Åbo Akademi University, Turku, Finland
| | - Pekka K Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterial Center-TCBC, Institute of Dentistry, University of Turku, Turku, Finland
- City of Turku Welfare Division, Oral Health Care, Turku, Finland
| | - Lippo Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterial Center-TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - Eija Säilynoja
- Department of Biomaterials Science and Turku Clinical Biomaterial Center-TCBC, Institute of Dentistry, University of Turku, Turku, Finland
- Research Development and Production Department, Stick Tech Ltd-Member of GC Group, Turku, Finland
| |
Collapse
|
3
|
Lassila L, Loimaranta V, Vallittu PK, Garoushi S. Bacterial adhesion and surface roughness of particulate-filled and short fiber-reinforced composites. Odontology 2024:10.1007/s10266-024-00997-z. [PMID: 39316233 DOI: 10.1007/s10266-024-00997-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2024] [Accepted: 08/18/2024] [Indexed: 09/25/2024]
Abstract
The objective of the study was to assess the initial adhesion of Streptococcus mutans (S. mutans) and surface roughness of different particulate-filled (PFC) and short fiber-reinforced (SFRC) composites. Five PFC composites (CeramX Universal, Filtek Universal, Omnichroma, Tetric Prime and Venus Diamond) and four SFRC composites (everX Posterior, everX Flow Bulk, everX Flow Dentin and experimental packable SFRC) were tested in this study. A non-contact 3D profilometer was employed to assess the surface roughness (Ra) of the polished specimens (using 4000-grit abrasive paper). For the bacterial adhesion test, the specimens (n = 5/group) were immersed in a solution of S. mutans to facilitate initial adhesion. To determine the number of cells on the surfaces of the discs as colony-forming units (CFU), the vials holding the microbial samples were highly agitated using a vortex machine. Subsequently, the samples were diluted multiple times and anaerobically incubated for 48 h at 37 °C on Mitis Salivarius Agar plates (Difco) supplemented with bacitracin. Bacterial adherence assessment was performed using SEM. The data were analyzed using ANOVA. All tested PFC and SFRC composites showed similar adhesion of S. mutan. The lowest Ra values (0.26 µm) (p < 0.05) were found in the flowable SFRCs (everX Flow Bulk & Dentin), while the highest values (p < 0.05) were observed in CeramX and everX Posterior (0.42 µm). Experimental SFRC had comparable Ra value (0.38 µm) than other commercial composites. The presence of short microfibers in the composite appeared to have no adverse effects on the initial adhesion of bacteria or the surface roughness.
Collapse
Affiliation(s)
- L Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterial Center, TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - V Loimaranta
- Department of Biomaterials Science and Turku Clinical Biomaterial Center, TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - P K Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterial Center, TCBC, Institute of Dentistry, University of Turku, Turku, Finland
- Wellbeing Services County of South-West Finland, Turku, Finland
| | - S Garoushi
- Department of Biomaterials Science and Turku Clinical Biomaterial Center, TCBC, Institute of Dentistry, University of Turku, Turku, Finland.
| |
Collapse
|
4
|
Rini ADK, Juwita FT, Bagjana RW, Octivany S, Purnama RB, Rijal MS, Anwar AM, Purwasasmita BS, Asri LATW. Improving the Mechanical Properties of Glass Ionomer Cement With Nanocrystalline Cellulose From Rice Husk. J Biomed Mater Res B Appl Biomater 2024; 112:e35472. [PMID: 39215536 DOI: 10.1002/jbm.b.35472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2023] [Revised: 04/09/2024] [Accepted: 08/09/2024] [Indexed: 09/04/2024]
Abstract
This study aimed to evaluate the effect of incorporating nanocrystalline cellulose (NCC) sourced from rice husk on the mechanical properties of a commercial glass ionomer cement (GIC). NCC was isolated through acid hydrolysis, and its crystallinity, chemical structure, and morphology were characterized through x-ray diffractometry, Fourier-transform infrared spectroscopy, and transmission electron microscopy, respectively. Various concentrations of NCC (0%, 0.5%, 1%, and 1.5%) were added to reinforce the GIC matrix. Mechanical tests including compressive strength, flexural strength, hardness, and shear bond strength were conducted on the modified GIC samples. The addition of NCC resulted in increased hardness and shear bond strength values, with 1% NCC showing the highest values compared to other concentrations. However, there was no significant improvement observed in the compressive and flexural strength of the modified GIC. Failure mode test revealed a reduction in adhesive failure with the addition of NCC. Incorporating small amounts of NCC (0.5%-1%) suggests a promising and affordable modification of GIC restorative material using biomass residue, resulting in improved mechanical properties.
Collapse
Affiliation(s)
- Aninda Dwi Kartika Rini
- Dental Medicine Study Program, Faculty of Medicine, Universitas Jendral Soedirman, Purwokerto, Indonesia
| | - Fifin Tresna Juwita
- Materials Science and Engineering Research Group, Faculty of Mechanical and Aerospace Engineering, Institut Teknologi Bandung, Bandung, Indonesia
| | - Riza Widyanti Bagjana
- Dental Medicine Study Program, Faculty of Medicine, Universitas Jendral Soedirman, Purwokerto, Indonesia
| | - Sherly Octivany
- Dental Medicine Study Program, Faculty of Medicine, Universitas Jendral Soedirman, Purwokerto, Indonesia
| | - Ryana Budi Purnama
- Dental Medicine Study Program, Faculty of Medicine, Universitas Jendral Soedirman, Purwokerto, Indonesia
| | - Moch Saifur Rijal
- Research Center for Nanoscience and Nanotechnology, Institut Teknologi Bandung, Bandung, Indonesia
| | - Ahmad Miftahul Anwar
- Materials Science and Engineering Research Group, Faculty of Mechanical and Aerospace Engineering, Institut Teknologi Bandung, Bandung, Indonesia
| | - Bambang Sunendar Purwasasmita
- Research Center for Nanoscience and Nanotechnology, Institut Teknologi Bandung, Bandung, Indonesia
- Engineering Physics Research Group, Faculty of Industrial Technology, Institut Teknologi Bandung, Bandung, Indonesia
| | - Lia A T W Asri
- Materials Science and Engineering Research Group, Faculty of Mechanical and Aerospace Engineering, Institut Teknologi Bandung, Bandung, Indonesia
| |
Collapse
|
5
|
Abdel-Maksoud HB, Eid BM, Hamdy M, Abdelaal HM. Optimizing fracture resistance of endodontically treated maxillary premolars restored with preheated thermos-viscous composite post-thermocycling, a comparative study. Part I. BMC Oral Health 2024; 24:295. [PMID: 38431585 PMCID: PMC10909284 DOI: 10.1186/s12903-024-03959-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2023] [Accepted: 01/30/2024] [Indexed: 03/05/2024] Open
Abstract
PURPOSE This research aimed to investigate fracture resistance of endodontically treated maxillary premolars restored using preheated thermo-viscous and fiber-reinforced bulk fill resin composite, in vitro. METHODOLOGY Sixty sound human maxillary premolars were selected and divided randomly into 6 groups of ten teeth each (n = 10). Group 1; is the positive control with sound unprepared teeth (P), Group 2; is the negative control in which Mesio-occluso-distal (MOD) cavities were left unrestored (N), Group 3; includes the teeth restored by incremental packing with conventional nanohybrid composite (ChP), Group 4; includes teeth restored with short fiber reinforced bulk fill composite (EF), Group 5; includes teeth restored with preheated thermo-viscous bulk fill composite (VB), and Group 6; includes teeth restored using packable bulk fill composite (XF) Tested restorative materials were bonded with a universal adhesive in self-etch mode. Teeth were kept in distilled water for 24 h at 37 °C proceeded by thermocycling (5- 55 °C, 1200×). Teeth were then exposed to compressive load till fracture at a crosshead speed of 1 mm/min. One-way ANOVA followed by Tukey post-hoc test was implemented to compare between more than two groups in non-related samples. The significance level was established at α = 0.05 for both tests. RESULTS Intact teeth significantly recorded the highest fracture resistance values among all groups. A significant difference was recorded among all the tested groups, with the EF recording the highest values, followed by the VB group then the XF group and ChP that recorded the lowest data. Negative control premolars significantly recorded the lowest fracture. CONCLUSIONS After thermocycling, endodontically treated maxillary premolars restored with pre-heated thermos-viscous composite did not exhibit an increase in fracture resistance. Notably, our findings indicate that short fiber-reinforced composite demonstrated significantly higher fracture resistance compared to other types of composites assessed in this study. This suggests the potential superiority of short fiber-reinforced composite in enhancing the overall structural integrity of endodontically treated teeth subjected to occlusal forces.
Collapse
Affiliation(s)
- Heba B Abdel-Maksoud
- Restorative Dentistry Department, Faculty of Dentistry, Suez Canal University, Ismailia, 41611, Egypt.
- Restorative Dentistry Department, King Abdulaziz University, P.O. Box 80209, Jeddah, 21589, Saudi Arabia.
| | - Bassem M Eid
- Restorative Dental Sciences Department, College of Dentistry, Gulf Medical University, Ajman, UAE
| | - Mai Hamdy
- Endodontic Department, Faculty of Dentistry, King Salman International University, El Tur, Egypt
- Endodontic Department, Faculty of Dentistry, Suez Canal University, Ismailia, 41611, Egypt
| | - Heba M Abdelaal
- Restorative Dental Sciences Department, College of Dentistry, Gulf Medical University, Ajman, UAE.
- Restorative Dentistry Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt.
| |
Collapse
|
6
|
Ivica A, Šalinović I, Jukić Krmek S, Garoushi S, Lassila L, Säilynoja E, Miletić I. Mechanical Properties and Ion Release from Fibre-Reinforced Glass Ionomer Cement. Polymers (Basel) 2024; 16:607. [PMID: 38475291 DOI: 10.3390/polym16050607] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 02/20/2024] [Accepted: 02/21/2024] [Indexed: 03/14/2024] Open
Abstract
The aim of this study was to compare the mechanical properties and ion release from a commercially available resin-modified glass ionomer cement to a formulation reinforced by the addition of short glass fibres at various percentages. Methods: Three experimental groups were prepared by adding a mass ratio of 10%, 15% and 20% of short glass fibres to the powder portion of the cement from a capsule (GC Fuji II LC), while the control group contained no fibres. Microhardness (n = 12), fracture toughness, and flexural, compressive and diametral tensile strength (n = 8) were evaluated. To study ion release, readings were obtained utilising fluoro-selective and calcium-selective electrodes after 24 h, 7 days and 30 days (n = 12). The spatial distribution of fibres within the material was evaluated through scanning electron microscopy. The data were analysed using one-way ANOVA with a Bonferroni adjustment. Results: The findings suggest that elevating fibre weight ratios to 20 wt% results in improved mechanical properties (p < 0.05) in microhardness, flexural strength, diametral tensile strength and fracture toughness. In terms of ion release, a statistically significant difference (p < 0.001) was observed between the groups at the conclusion of 24 h and 7 days, when the fluoride release was much higher in the control group. However, after 30 days, no significant distinction among the groups was identified (p > 0.05). Regarding calcium release, no statistically significant differences were observed among the groups at any of the evaluated time points (p > 0.05). SEM showed the fibres were homogeneously incorporated into the cement in all experimental groups. Conclusions: Resin-modified glass ionomer enhanced with short glass fibres at a weight loading of 20% showcased the most favourable mechanical properties while concurrently maintaining the ability to release fluoride and calcium after a 30-day period.
Collapse
Affiliation(s)
- Anja Ivica
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Ivan Šalinović
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Silvana Jukić Krmek
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| | - Sufyan Garoushi
- Department of Biomaterials Science and Turku Clinical Biomaterial Center-TCBC Institute of Dentistry, University of Turku, 20520 Turku, Finland
| | - Lippo Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterial Center-TCBC Institute of Dentistry, University of Turku, 20520 Turku, Finland
| | - Eija Säilynoja
- Department of Biomaterials Science and Turku Clinical Biomaterial Center-TCBC Institute of Dentistry, University of Turku, 20520 Turku, Finland
- Research Development and Production Department, Stick Tech Ltd., 20520 Turku, Finland
| | - Ivana Miletić
- Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia
| |
Collapse
|
7
|
Matic T, Zebic ML, Miletic V, Trajkovic I, Milosevic M, Racic A, Veljovic D. Hydroxyapatite-based dental inserts: Microstructure, mechanical properties, bonding efficiency and fracture resistance of molars with occlusal restorations. J Biomed Mater Res B Appl Biomater 2024; 112:e35331. [PMID: 37792306 DOI: 10.1002/jbm.b.35331] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2023] [Revised: 07/23/2023] [Accepted: 09/07/2023] [Indexed: 10/05/2023]
Abstract
This study aimed to (1) comparatively analyze properties of Sr- and Mg-substituted hydroxyapatite (HAP)-based dental inserts; (2) evaluate insert bonding to restorative materials, and (3) evaluate the effect of doped HAP inserts on fracture resistance (FR) of human molars with large occlusal restorations. By ion-doping with Sr or Mg, 3 insert types were obtained and characterized using XRD, SEM, Vickers hardness and fracture toughness. Shear bond strength (SBS) was determined between acid etched or unetched inserts and following materials: Maxcem cement (Kerr); Filtek Z250 (3M) bonded with Single Bond Universal (SBU; 3M) or Clearfil Universal (Cf; Kuraray). Modified Class I cavities were prepared in 16 intact molars and restored using insert + composite or composite only (control) (n = 8/group). FR of restored molars was determined by static load until fracture upon thermal cycling. Fracture toughness was similar between Sr/Mg-doped inserts (0.94-1.04 MPam-1/2 p = .429). Mg-doped inserts showed greater hardness (range 4.78-5.15 GPa) than Sr6 inserts (3.74 ± 0.31 GPa; p < .05). SBS for SBU and Cf adhesives (range 7.19-15.93 MPa) was higher than for Maxcem (range 3.07-5.95 MPa) (p < .05). There was no significant difference in FR between molars restored with insert-containing and control restorations (3.00 ± 0.30 kN and 3.22 ± 0.42 kN, respectively; p > .05). HAP-based inserts doped with Mg/Sr had different composition and mechanical properties. Adhesive bonding to inserts resulted in greater bond strength than cementation, which may be improved by insert acid-etching. Ion-doped HAP inserts did not affect FR of restored molars. In conclusion, HAP-based dental inserts may potentially replace dentin in large cavities, without affecting fracture resistance of restored teeth.
Collapse
Affiliation(s)
- Tamara Matic
- Innovation Center of the Faculty of Technology and Metallurgy, Ltd, Belgrade, Serbia
| | | | - Vesna Miletic
- Faculty of Medicine and Health, Sydney Dental School, The University of Sydney, Surry Hills, New South Wales, Australia
| | - Isaak Trajkovic
- Innovation Center of the Faculty of Mechanical Engineering, Ltd, Belgrade, Serbia
| | - Milos Milosevic
- Innovation Center of the Faculty of Mechanical Engineering, Ltd, Belgrade, Serbia
| | - Aleksandar Racic
- School of Dental Medicine, University of Belgrade, Belgrade, Serbia
| | - Djordje Veljovic
- Faculty of Technology and Metallurgy, University of Belgrade, Belgrade, Serbia
| |
Collapse
|
8
|
Saratti CM, Scotti N, Comba A, Bijelic-Donova J, Suchy T, Abdelaziz M, Leprince JG, Rocca GT. Exploring the influence of placing bi-directional E-glass fibers as protective layer under a CAD-CAM resin composite on the fracture pattern. Dent Mater 2023; 39:986-993. [PMID: 37734973 DOI: 10.1016/j.dental.2023.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 08/17/2023] [Accepted: 09/15/2023] [Indexed: 09/23/2023]
Abstract
OBJECTIVES To investigate the influence of the presence and position of bidirectional E-glass fibers under a CAD-CAM resin composite on the fracture pattern evaluated both after quasi-static mechanical loading and after fatigue. METHODS Rectangular specimens (10 mm-long, 5 mm-large and 4.2 mm-thick) were prepared and divided into four groups (n = 30/group). The control group (C-Group) consisted of a 4.2 mm-thick layer of monolithic CAD/CAM resin composite resin (Cerasmart, GC). In the 3 other groups including the placement of a fiber layer (F-Groups), the CAD/CAM resin composite layer was reduced to 3-, 2- and 1-mm thickness (F3-, F2- and F1-Groups, respectively). Two bonded layers of bidirectional E-glass FRC (Dentapreg, ADM A.S.) were bonded underneath and a light-curable resin composite base (Gaenial Posterior, GC) was then added to reach a total thickness of 4.2 mm for all samples. In each group, half of the specimens (n = 15) were submitted to quasi-static mechanical loading to failure in a universal testing machine. The other half (n = 15) was subjected to cyclic isometric stepwise loading until failure or completion of 105000 cycles (5000 cycles at 500 N, followed by five stages of 20000 cycles at 750 N, 1000 N, 1250 N, 1500 N, and 1750 N). The data were analyzed by Weibull statistics for quasi-static loading, and by the Kaplan-Meier product limit estimation procedure after fatigue. All fractured specimens were studied using light and electron microscopy techniques, and the types of fracture were determined. RESULTS For quasi-static mechanical loading, significant differences were observed for Weibull modulus and characteristic strength between groups, with values ranging from 10.8 to 22.4 for the former and from 2336.6 to 2974.7 for the latter. Also, survival after stepwise fatigue revealed statistically significant differences between groups (p < 0.05), the lowest values of cycles before failure being observed for F1-Group - Median = 61223 (50415; 65446) - as compared to the other groups - C-Group: Median = 89005 (86189; 98195); F3-Group: Median = 85198 (77279; 87860); F2-Group: Median = 89306 (87454; 97024). Both in quasi-static loading and after fatigue, the observation of fracture modes revealed major differences. While all fractures were vertical (split) in C-Group, the majority of the specimens in F-Groups presented some degree of horizontal deflection of the crack. In all deviated fractures, fractographic analysis confirmed a toughening effect of the fiber layer. SIGNIFICANCE The present in vitro work tends to show that the fracture pattern of CAD-CAM resin composites is favorably affected by the presence and position of an underlying bidirectional E-glass fiber layer. The placement of E-glass fibers under a CAD-CAM resin composite may therefore represent an interesting strategy to reduce the risk of catastrophic restoration failure, which could be integrated in the development of the new generation of indirect materials, possibly in 3D-printing approaches.
Collapse
Affiliation(s)
- C M Saratti
- Division of Cariology and Endodontology, School of Dentistry, University of Geneva, Geneva, Switzerland.
| | - N Scotti
- Department of Surgical Sciences, Dental School, University of Turin, Turin, Italy
| | - A Comba
- Department of Surgical Sciences, Dental School, University of Turin, Turin, Italy
| | - J Bijelic-Donova
- Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, Lemminkäisenkatu 2, Turku, Finland
| | - T Suchy
- Department of Composites and Carbon Materials, Institute of Rock Structure and Mechanics, Academy of Sciences of the Czech Republic, Prague, Czech Republic
| | - M Abdelaziz
- Division of Cariology and Endodontology, School of Dentistry, University of Geneva, Geneva, Switzerland
| | - J G Leprince
- Division of Cariology and Endodontology, School of Dentistry, University of Geneva, Geneva, Switzerland
| | - G T Rocca
- Division of Cariology and Endodontology, School of Dentistry, University of Geneva, Geneva, Switzerland
| |
Collapse
|
9
|
Tsertsidou V, Mourouzis P, Dionysopoulos D, Pandoleon P, Tolidis K. Fracture Resistance of Class II MOD Cavities Restored by Direct and Indirect Techniques and Different Materials Combination. Polymers (Basel) 2023; 15:3413. [PMID: 37631470 PMCID: PMC10458958 DOI: 10.3390/polym15163413] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Revised: 08/04/2023] [Accepted: 08/14/2023] [Indexed: 08/27/2023] Open
Abstract
This study aimed to evaluate the fracture resistance of class II MOD cavities restored using different techniques and materials. Sixty extracted maxillary molars were selected and standardized class II MOD cavities were prepared using a custom-made paralleling device. The specimens were divided into four groups based on the restoration technique used: Group 1 (direct resin composite), Group 2 (short-fiber-reinforced composite resin), Group 3 (composite polyethylene fiber reinforcement), and Group 4 (CAD/CAM resin inlays). Fracture resistance was assessed for each group after thermocycling aging for 10,000 cycles. The mode of fracture was assigned to five types using Burke's classification. To compare the fracture force among the tested materials, a paired sample t-test was performed. The significance level for each test was set at p < 0.05. Significant differences in fracture resistance were observed among the different restoration techniques. CAD/CAM inlays (2166 ± 615 N), short-fiber-reinforced composite resin (2471 ± 761 N), and composite polyethylene fiber reinforcement (1923 ± 492 N) showed superior fracture resistance compared to the group restored with direct resin composite (1242 ± 436 N). The conventional resin composite group exhibited the lowest mean fracture resistance. The choice of restoration material plays a critical role in the clinical survival of large MOD cavities. CAD/CAM inlays and fiber-reinforced composites offer improved fracture resistance, which is essential for long-term success in extensive restorations.
Collapse
Affiliation(s)
- Vasiliki Tsertsidou
- Department of Dental Tissues Pathology and Therapeutics, Division of Operative Dentistry, Faculty of Dentistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; (V.T.); (D.D.); (K.T.)
| | - Petros Mourouzis
- Department of Dental Tissues Pathology and Therapeutics, Division of Operative Dentistry, Faculty of Dentistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; (V.T.); (D.D.); (K.T.)
| | - Dimitrios Dionysopoulos
- Department of Dental Tissues Pathology and Therapeutics, Division of Operative Dentistry, Faculty of Dentistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; (V.T.); (D.D.); (K.T.)
| | - Panagiotis Pandoleon
- Department of Prosthodontics, Faculty of Dentistry, School of Health Sciences, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece;
| | - Kosmas Tolidis
- Department of Dental Tissues Pathology and Therapeutics, Division of Operative Dentistry, Faculty of Dentistry, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece; (V.T.); (D.D.); (K.T.)
| |
Collapse
|
10
|
Fatigue Resistance of Dissected Lower First Molars Restored with Direct Fiber-Reinforced Bridges—An In Vitro Pilot Study. Polymers (Basel) 2023; 15:polym15061343. [PMID: 36987124 PMCID: PMC10053716 DOI: 10.3390/polym15061343] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2023] [Revised: 03/02/2023] [Accepted: 03/03/2023] [Indexed: 03/10/2023] Open
Abstract
The aim of this research was to evaluate the mechanical impact of utilizing different fiber-reinforced composite (FRC) systems to reinforce inlay-retained bridges in dissected lower molars with different levels of periodontal support. A total of 24 lower first molars and 24 lower second premolars were included in this study. The distal canal of all molars received endodontic treatment. After root canal treatment, the teeth were dissected, and only the distal halves were kept. Standardized class II occluso-distal (OD) (premolars) and mesio-occlusal (MO) (dissected molars) cavities were prepared in all teeth, and premolar–molar units were created. The units were randomly distributed among four groups (n = six/group). With the aid of a transparent silicone index, direct inlay-retained composite bridges were fabricated. In Groups 1 and 2, both discontinuous (everX Flow) and continuous (everStick C&B) fibers were used for reinforcement, while in Groups 3 and 4, only discontinuous fibers (everX Flow) were used. The restored units were embedded in methacrylate resin, simulating either physiological periodontal conditions or furcation involvement. Subsequently, all units underwent fatigue survival testing in a cyclic loading machine until fracture, or a total of 40,000 cycles. Kaplan–Meyer survival analyses were conducted, followed by pairwise log-rank post hoc comparisons. Fracture patterns were evaluated visually and with scanning electron microscopy. In terms of survival, Group 2 performed significantly better than Groups 3 and 4 (p < 0.05), while there was no significant difference between the other groups. In the case of impaired periodontal support, a combination of both continuous and discontinuous short FRC systems increased the fatigue resistance of direct inlay-retained composite bridges compared to bridges that only contained short fibers. Such a difference was not found in the case of sound periodontal support between the two different bridges.
Collapse
|
11
|
Crack propensity of different direct restorative procedures in deep MOD cavities. Clin Oral Investig 2023; 27:2003-2011. [PMID: 36814029 DOI: 10.1007/s00784-023-04927-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2022] [Accepted: 02/16/2023] [Indexed: 02/24/2023]
Abstract
OBJECTIVE The purpose was to evaluate the crack formation associated with different direct restorative procedures of the utilized resin composites (RC) right after and 1 week later of the restoration. MATERIALS AND METHODS Eighty intact, crack-free third molars with standard MOD cavities were included in this in vitro study and randomly divided into four groups of 20 each. After adhesive treatment, the cavities were restored either with bulk (group 1) or layered (group 2) short-fiber-reinforced resin composites (SFRC); bulk-fill RC (group 3); and layered conventional RC (control). Right after the polymerization and a week later, crack evaluation on the outer surface of the remaining cavity walls was performed with a transillumination method utilizing the D-Light Pro (GC Europe) with the "detection mode." Between- and within-groups comparisons Kruskal-Wallis and Wilcoxon tests were used, respectively. RESULTS Post-polymerization crack evaluation showed significantly lower crack formation in SFRC groups compared to the control (p<0.001). There was no significant difference within SFRC groups and non-SFRC groups (p=1.00 and p=0.11, respectively). Within group comparison revealed significantly higher number of cracks in all groups after 1 week (p≤0.001), however, only the control group differed significantly from all the other groups (p≤0.003). CONCLUSIONS Post-polymerization shrinkage induced further crack formation in the tooth 1 week after the restoration. SFRC was less prone to shrinkage-related crack formation during the restorative procedure; however, after 1 week, besides SFRC, bulk-fill RC also showed less prone to polymerization shrinkage-related crack formation than layered composite fillings. CLINICAL RELEVANCE SRFC can decrease the shrinkage stress-induced crack formation in MOD cavities.
Collapse
|
12
|
Garoushi S, Vallittu P, Lassila L. Development and characterization of ion-releasing fiber-reinforced flowable composite. Dent Mater 2022; 38:1598-1609. [PMID: 36041943 DOI: 10.1016/j.dental.2022.08.006] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Revised: 08/12/2022] [Accepted: 08/18/2022] [Indexed: 11/03/2022]
Abstract
OBJECTIVE This study aimed to develop and characterize an ion-releasing experimental fiber-reinforced flowable composite (Bio-SFRC) and dentin treatment solution made of poly(acrylic acid) (PAA) with a high molecular weight. In addition we also evaluated the interface structure and mineralization potential between the Bio-SFRC and dentin. METHODS Some mechanical properties (flexural properties and fracture toughness) of Bio-SFRC in comparison with commercial inert (G-aenial Flo X) and ion-releasing materials (ACTIVA-BioActive Base/Liner and Fuji II LC) were assessed (n = 8/group). Calcium-release at different time-points was measured during the first six weeks by using a calcium-ion selective electrode. Surface analysis of composites after being stored in simulated body fluid (SBF) was investigated by using SEM/EDS. Dentin disks (n = 50) were prepared from extracted sound teeth and demineralization was simulated by acid etching. SEM/EDS was used to evaluate the microstructure of dentin on the top surface and at interface with composites after being stored in SBF. RESULTS Bio-SFRC showed higher fracture toughness (1.6 MPa m1/2) (p < 0.05) compared to Flo X (1.2 MPa m1/2), ACTIVA (1 MPa m1/2) and Fuji II LC (0.8 MPa m1/2). Accumulative calcium release after six weeks from Bio-SFRC (15 mg/l) was higher than other tested ion-releasing materials (≈ 6 mg/l). Mineralization was clearly seen at the interface between treated dentin and Bio-SFRC. None of the commercial tested materials showed signs of mineralization at the interface and dentinal tubules remained open. SIGNIFICANCE Developing such reinforced ion-releasing flowable composite and PAA solution might offer the potential for mineralization at the interface and inside the organic matrix of demineralized dentin.
Collapse
Affiliation(s)
- Sufyan Garoushi
- Department of Biomaterials Science and Turku Clinical Biomaterial Center -TCBC, Institute of Dentistry, University of Turku, Turku, Finland.
| | - Pekka Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterial Center -TCBC, Institute of Dentistry, University of Turku, Turku, Finland; City of Turku Welfare Division, Oral Health Care, Turku, Finland
| | - Lippo Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterial Center -TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| |
Collapse
|
13
|
Fracture Resistance and Microleakage around Direct Restorations in High C-Factor Cavities. Polymers (Basel) 2022; 14:polym14173463. [PMID: 36080538 PMCID: PMC9460406 DOI: 10.3390/polym14173463] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Revised: 08/20/2022] [Accepted: 08/21/2022] [Indexed: 11/29/2022] Open
Abstract
The aim of this research was to evaluate the mechanical impact of different direct restorations in terms of fracture resistance, and subsequent fracture pattern, in occlusal high C-factor cavities. Furthermore, the adaptation of different direct restorations in the form of gap formation was also evaluated. Seventy-two intact mandibular molars were collected and randomly distributed into three groups (n = 24). Class I occlusal cavities with standardized dimensions were prepared in all specimens. After adhesive treatment, the cavities were restored with direct restorations utilizing three different materials. Group 1: layered conventional packable resin composite (Filtek Ultimate), Group 2: bulk-fill resin composite (SDR), Group 3: bulk-fill short fibre-reinforced composite (SFRC; everX Posterior) covered with packable composite occlusally. Half of the restored specimens underwent static load-to fracture testing (n = 12/group), while the rest underwent sectioning and staining for microleakage evaluation and gap formation analysis. Fracture patterns were evaluated visually among the mechanically tested specimens. The layered composite restoration (Group 1) showed significantly lower fracture resistance compared to the bulk fill groups (Group 2, p = 0.005, Group 3, p = 0.008), while there was no difference in fracture resistance between the other groups. In terms of gap formation values, the layered composite restoration (Group 1) produced significantly higher gap formation compared to the bulk-fill groups (Group 2, p = 0.000, Group 3, p = 0.000). Regarding the fracture pattern, SFRC (Group 3) produced the highest number, while SDR (Group 2) produced the lowest number of repairable fractures. The use of bulk-fill resin composite (fibre or non-fibre-reinforced) for occlusal direct restorations in high C-factor cavities showed promising achievements regarding both fracture resistance and microleakage. Furthermore, the use of short fibre-reinforced bulk-fill composite can also improve the fracture pattern of the restoration-tooth unit. Bulk-fill materials provide a simple and effective solution for restoring and reinforcing high C-factor occlusal cavities.
Collapse
|
14
|
Lassila L, Tuokko J, Suni A, Garoushi S, Vallittu PK. Effect of interfacial surface treatment on bond strength of particulate-filled composite to short fiber-reinforced composite. Biomater Investig Dent 2022; 9:33-40. [PMID: 35559270 PMCID: PMC9090340 DOI: 10.1080/26415275.2022.2070489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Objective The aim was to investigate the effect of different interfacial surface treatments on the shear bond strength (SBS) between a short fiber-reinforced flowable composite (SFRC) and a particulate-filled flowable composite (PFC). In addition, SBS between two successive layers of similar materials was evaluated. Materials and methods One-hundred and forty-four specimens were prepared having either SFRC (everX Flow) as a substructure composite and PFC (G-aenial Flo X) as a surface composite or having one of the two materials as both substructure and surface layer. Eight groups of specimens were created (n = 18/per group) according to the interfacial surface protocol used. Group 1: no treatment; Group 2: ethanol one wipe; Group 3: ethanol three wipes; Group 4: phosphoric acid etching + bonding agent; Group 5: hydrofluoric acid etching + bonding agent; and Group 6: grinding + phosphoric acid etching. Group 7: only PFC layers and Group 8 (control) only SFRC layers without any surface treatment. After one-day storage (37 °C), SBS between surface and substructure composite layers was measured in a universal testing machine, and failure modes were visually analyzed. SEM was used to examine the bonding surface of the SFRC composite after surface treatment. SBS values were statistically analyzed with a one-way analysis of variance (ANOVA) followed by the Tukey HSD test (α = .05). Results The SBS between successive SFRC layers (Group 8) was statistically (p < .05) the highest (43.7 MPa) among tested groups. Surface roughening by grinding followed by phosphoric acid etching (Group 6) resulted in a higher SBS (28.8 MPa) than the remaining surface treatments. Conclusion Flowable composite with glass fibers (everX Flow) showed higher interlayer SBS compared to PFC flowable composite. Interfacial surface roughness increases the bonding of PFC to the substructure of SFRC.
Collapse
Affiliation(s)
- L. Lassila
- Department of Biomaterials Science and Turku Clinical Biomaterials Center – TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - J. Tuokko
- Department of Biomaterials Science and Turku Clinical Biomaterials Center – TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - A. Suni
- Department of Biomaterials Science and Turku Clinical Biomaterials Center – TCBC, Institute of Dentistry, University of Turku, Turku, Finland
| | - S. Garoushi
- Department of Biomaterials Science and Turku Clinical Biomaterials Center – TCBC, Institute of Dentistry, University of Turku, Turku, Finland,CONTACT S. Garoushi Department of Biomaterials Science, Institute of Dentistry and TCBC, University of Turku, Turku, Finland
| | - P. K. Vallittu
- Department of Biomaterials Science and Turku Clinical Biomaterials Center – TCBC, Institute of Dentistry, University of Turku, Turku, Finland,City of Turku Welfare Division, Oral Health Care, Turku, Finland
| |
Collapse
|